ML061800352

From kanterella
Jump to navigation Jump to search
Final Outlines (Folder 3)
ML061800352
Person / Time
Site: FitzPatrick 
(DPR-059)
Issue date: 06/05/2006
From: Conte R
Operations Branch I
To: Ted Sullivan
Entergy Nuclear Northeast
Sykes, Marvin D.
References
50-333/06-301 50-333/06-301
Download: ML061800352 (13)


Text

~

ES-401 1

Form ES-401-1 Facility:

J.A. FitzPatrick Date of Exam:

June 16,2006 RO WA Category Points SRO-Only Points Notes:

1.
2.
3.
4.
5.
6.

7.*

8.
9.

Ensure that at least two topics from every WA category are sampled within each tier of the do and SRO-only outlines (Le., except for one category in Tier 3 of the SRO-only outline, the "Tier Totals" in each WA category shall not be less than two).

The point total for each group and tier in the proposed outline must match that specified in the table. The final point total for each group and tier may deviate by k1 from that specified in the table based on NRC revisions. The final RO exam must total 75 points and the SRO-only exam must total 25 points.

Systems/evolutions within each group are identified on the associated outline; systems or evolutions that do not apply at the facility should be deleted or justified; operationally important, site-specific systems that are not included on the outline should be added. Refer to ES-401,, for guidance regarding the elimination of inappropriate WA statements.

Select topics from as many systems and evolutions as possible; sample every system or evolution in the group before selecting a second topic for any system or evolution.

Absent a plant-specific priority, only those WAS having an importance rating (IR) of 2.5 or higher shall be selected. Use the RO and SRO ratings for the RO and SRO-only portions, respectively.

Select SRO topics for Tiers 1 and 2 from the shaded systems and WA categories.

The generic (G) WAS in Tiers 1 and 2 shall be selected from Section 2 of the WA Catalog, but the topics must be relevant to the applicable evolution or system.

On the following pages, enter the WA numbers, a brief description of each topic, the topics' importance ratings (IR) for the applicable license level, and the point totals (#) for each system and category. Enter the group and tier totals for each category in the table above. Use duplicate pages for RO and SRO-only exams.

For Tier 3, select topics from Section 2 of the WA catalog, and enter the WA numbers, descriptions, IRs, and point totals (#) on Form ES-401-3. Limit SRO selections to WAS that are linked to 10 CFR 55.43.

Rev 1

ES-401 K

1 ElAPE # I Name I Safety Function 295003 Partial or Complete Loss of AC I 6 ES-401 2

Form ES-401-1 295004 Partial or Total Loss of DC Pwr / 6 295005 Main Turbine Generator Trip / 3 I

295023 Refueling Acc / 8 295024 High Drywell Pressure 15 1

Form ES-401-1 BWR Examination Outline Emergency and Abnormal Plant Evolutions - Tier 1lGroup 1 (RO / SRO)

AA2.04 (10CFR 55.43.5)

Ability to determine and/or interpret the following as they apply to PARllAL OR COMPLETE LOSS OF A.C. POWER:

AA2.02 (10CFR 55.43.5)

Ability to determine and/or interpret the following as they apply to PARTIAL OR COMPLETE LOSS OF D.C. POWER:

DRY W ELL PRESSURE:

+ Suppression pool temperature 6/5/2006 - 2:32:34 PM Rev 1 Page 2

ES-401 EIAPE # I Name I Safety Function 295025 High Reactor Pressure I 3 295031 Reactor Low Water Level / 2 WA Category Totals: (RO)

~~~

WA Category Totals: (SRO) I BWR Examination Outline Form ES-401-1 Emergency and Abnormal Plant Evolutions - Tier IlGroup 1 (RO / SRO)

WA Topic@)

I IR EA2.04 (10CFR 55.43.2/5)

Ability to determine and/or interpret the following as they apply to HIGH REACTOR PRESSURE:

+

Suppression pool level 3.9 G2.3.9 (10CFR 55.43.4)

Knowledge of the process for performing a containment purge.

1 3.4 6

7 NIA 7

6/5/2006 - 2:32:34 PM Rev 1 Page 3

ES-401 3

Form ES-401-1 ES-401 ElAPE # I Name I Safety Function 295007 High Reactor Pressure / 3 295008 High Reactor Water Level / 2 295014 Inadvertent Reactivity Addition / 1 BWR Examination Outline Emergency and Abnormal Plant Evolutions - Tier l/Group 2 (RO / SRO)

Form ES-401-1 KIA Topic@)

62.1.30 (10CFR 55.43.5)

Ability to locate and operate components / including local controls.

AA2.04 (10 CFR 55.43.5)

Ability to determine and/or interpret the following as they apply to HIGH REACTOR WATER LEVEL:

+

Heatup rate: Plant-Specific 3.3 9

AA2.02 (10 CFR 55.43.6)

Ability to determine and/or interpret the following as they apply to INADVERTENT REACTNlTY ADDITION:

+

Reactor period 3.9 10 6/5/2006 - 2:32:34 PM Rev 1 Page 4

ES-401 3

Form ES-401-1 6/5/2006 - 2:32:34 PM Rev 1 Page 5

I1 ES-401 System # I Name ll 206000 HPCl

/I I

211000SLC 21 7000 RCIC Form ES-401-1 ES-401 4

6/5/2006 - 2:32:34 PM Rev 1 BWR Examination Outline Plant Systems -Tier 2IGroup 1 (RO I SRO)

I 62.4.19 (10CFR 55.43.5)

......... 62-2-24 (10CFR 55.43.2)

................. Ability to analyze the effect of maintenance activities on LCO status.

A2.11 (10CFR 55.43.5)

Ability to (a) predict the impacts of the following on the REACTOR CORE ISOLATION COOLING SY9EM (RCIC); and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

+ Inadequate system flow Form ES-401-1 3.7 1 11 3.2 13 Page 6

ES-401 4

Form ES-401-1 II ES-401 System # / Name 259002 Reactor Water Level I

1 Control I

I WA Category Point Totals:

WA Category Point Totals: I BWR Examination Outline Form ES-401-1 Plant Systems -Tier 2IGroup 1 (RO I SRO)

A i"* I::::

j:i::.:.:.:.:.:.:

.................::::I I

IR KIA Topic@)

A2.01 (10CFR 55.43.5)

Ability to (a) predict the impacts of the following on the RELIEF /

SAFETY VALVES; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

+ Stuck open vacuum breakers 3.3

.:.:.:..... :.:.:. 62.2.11 (10CFR 55.43.3)

I:::::::/

Knowledge of the process for controlling temporary changes.

Group Point Total: (RO)

Group Point Total: (SRO) 14 6/5/2006 - 2:32:34 PM Rev 1 Page 7

ES-401 5

Form ES-401-1 ES-401 BWR Examination Outline Plant Systems -Tier ZGroup 2 (RO / SRO)

Form ES-401-1 System # I Name IklmT KIA Topic@)

A2.01 (10CFR 55.43.5)

Ability to (a) predict the impacts of the following on the CONTROL ROD AND DRIVE MECHANISM; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

+ Stuck rod 3.6 16 A2.03 (10CFR 55.43.5)

Ability to (a) predict the impacts of the following on the NUCLEAR BOILER INSTRUMENTATION; and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those abnormal conditions or operations:

+ Instrument line leakaqe 3.1 17 6/5/2006 - 2:32:34 PM Rev 1 Page 8

ES-401 5

Form ES-401-1 II ES-401 11 System # I Name 21 9000 RHRILPCI: TorusIPool Cooling Mode t BWR Examination Outline Form ES-401-1 Plant Systems -Tier ZGroup 2 (RO I SRO) consequences of those abnormal conditions or operations:

+ Valve loaic failure: Plant-SDecific 18 6/5/2006 - 2:32:34 PM Rev 1 Page 9

ES-401 5

Form ES-401-1 6/5/2006 - 2:32:34 PM Rev 1 Page 10

Generic Knowledae and Abilities Outline (Tier 3)

Form ES-401-3 Facility:

JJ FitzPat KIA #

2.1.

2.1.

Subtotal

2.2. Subtot

k Date of Exam:

June 16,2006 RO SRO-Only Topic IR IR 62.1.11 (10CFR 55.43.2)

Knowledge of less than one hour technical 3.8 19 specification action statements for systems.

6/5/2006 - 2:43:10 PM Rev 1 Page 11

ES-401 Generic Knowledge and Abilities Outline (Tier 3)

Form ES-401-3 Date of Exam:

June 16,2006 Facility:

J.A. FitzPatrick I

RO SRO-Only Topic I

IR IR Knowledge of how event-based emergency/abnormal operating procedures are used in conjunction with the symptom based EOPs.

2.4.

62.4.49 (10CFR 55.43.2)

    • Industry OE - JAF CA**

Ability to perform without reference to orocedure those actions that require immediate 3.7 24 6/5/2006 - 2:43:10 PM Rev 1 Page 12

V ES-401 Record of Rejected WAS Form ES-401-4 Tier i Group lil 1 1 2

?/I 3

3 3

2 i 2 111 3

~

Randomly Selected WA 295026 295010 G 295026 G2.3.5 G2.3.7 G2.1.2 268000 A2.03 295038 G2.2.12 G2.3.2 Reason for Rejection Random Number Generator hit on a 7 for a second time on this draw. This would have resulted in two questions in Suppression Pool High Water Temperature.

All three Tier 1 Group 2 randomly selected as Generic.

Randomly chose one to become an A2 versus G. Random Number Generator kicked out a I which corresponded to the first selection on the page.

Rejected on overlap with 295024 and 295025 - all suppression pool related. Randomly sampled which one of three to revise.

Randomly re-sampled category A2 iG, which again yielded A2.

Due to limited A2 selections, rejected 295026 and randomly determined a new WAPE, which yielded 295004.

No identified linkage to IOCFR 55.43, per BWR Exam Outline (Form ES-401-1) Note 9.

No identified linkage to IOCFR 55.43, per BWR Exam Outline (Form ES-401-1) Note 9.

No identified linkage to IOCFR 55.43, per BWR Exam Outline (Form ES-401-1) Note 9.

Rejected on WA < 2.5 (2.3). No plant-specific priority.

No identified linkage to IOCFR 55.43. Rejected in accordance with ES-401, Attachment 2, WA Elimination Guidance, Note 1.

KBA not amendable to SRO only question.

6/5/2006 - 3:01:41 PM Rev 1 Page 1