Request for Relief from ASME Boiler and Pressure Vessel Code,Section XI Requirements for Use of Penetrameters in Radiographic Examinations
ML061720388
Person / Time
Site: Calvert Cliffs, Indian Point, South Texas  
Issue date: 06/14/2006
From: Berg M
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
G25, NOC-AE-06002031, RR-ENG-2-45, STI: 32018352
Download: ML061720388 (5)


Text

Nuclear Operating Company South Texas Prolcd Ekfltfc GeneMrn&StatIon P/10 Box 28.9 Wad&uorth, Te7as 77483

/

June 14, 2006 NOC-AE-06002031 File No.: G25 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attention: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 South Texas Project Units 1 and 2 Docket No. STN 50-498, STN 50-499 Request for Relief from ASME Boiler and Pressure Vessel Code,Section XI Requirements for Use of Penetrameters in Radiographic Examinations (Relief Request RR-ENG-2-45)

Pursuant to 10 CFR 50.55a(a)(3)(i), STP Nuclear Operating Company (STPNOC) proposes an alternative to the nondestructive examination requirements applicable to ASME Classes 1, 2, and 3 welds and weld repairs.

Approval will allow "wire-type" penetrameters to be used in performing radiographic examinations in accordance with Tables NB-5i 11-1 and NC-5i 11-1 of ASME Section II1, 1992 Edition with 1993 Addenda as an alternative to the "hole-type" penetrameters addressed in the 1992 Edition, no addenda, of Section II1. The proposed alternative will provide an acceptable level of quality and safety.

The NRC staff has approved similar requests for:

" Calvert Cliffs, Units 1 and 2; and

" Indian Point, Unit 2 STPNOC requests that the staff approve the use of RR-ENG-2-45 by August 2, 2006, to support scheduling for the Unit 1 refueling outage in October 2006.

This letter contains no commitments.

If there are any questions, please contact either Mr. P. L. Walker at (361) 972-8392 or me at (361) 972-7030.

rM.,Berg Manager Testing/Programs PLW

Attachment:

Relief Request for Application of Penetrameters in Radiographic Examinations (Relief Request RR-ENG-2-45)

STI: 32018352

NOC-AE-06002031 Page 2 of 2 cc:

(paper copy)

(electronic copy)

Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Richard A. Ratliff Bureau of Radiation Control Texas Department of State Health Services 1100 West 49th Street Austin, TX 78756-3189 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Mohan C. Thadani U. S. Nuclear Regulatory Commission Steve Winn Christine Jacobs Eddy Daniels NRG South Texas LP J. J. Nesrsta R. K. Temple E. Alarcon City Public Service C. Kirksey City of Austin Jon C. Wood Cox Smith Matthews STI: 32018352

Attachment NOC-AE-06002031 Page 1 of 3 SOUTH TEXAS PROJECT UNITS 1 AND 2 RELIEF REQUEST FOR APPLICATION OF PENETRAMETERS IN RADIOGRAPHIC EXAMINATIONS (RELIEF REQUEST RR-ENG-2-45)

1.0 ASME Code Components Affected

==

Description:==

Components with welded repairs and replacement components with fabrication welds or installed by welding Class:

ASME Code Classes 1, 2, and 3 Function:

Multiple, depends on the specific application 2.0

Applicable Code Edition and Addenda

ASME Boiler and Pressure Vessel Code, Section Xl, 1989 Edition, No Addenda ASME Boiler and Pressure Vessel Code,Section III, 1992 Edition, No Addenda 3.0 Applicable Code Requirements As noted in IWA-4120, ASME Section XI, 1989 Edition:

Repairs shall be performed in accordance with the Owner's Design Specification and the original Construction Code of the component or system.

Later Editions and Addenda of the Construction Code or of Section III, either in their entirety or portions thereof, and Code Cases may be used.

In accordance with the provisions of 1 OCFR50.55a(a)(3)(i), STPNOC has been approved to use a system leakage test to detect leakage from welded repairs, fabrication welds for replacement parts and piping subassemblies, and welds for installation of replacement items in accordance with Code Case N-416-2 as an alternative to system hydrostatic testing required by IWA-4700. For a system leakage test to be used, Code Case N-416-2 requires performance of non-destructive examination in accordance with the methods and acceptance criteria of the applicable Subsection of the 1992 Edition of Section III, no Addenda.

ASME Section III, 1992 Edition includes the following:

" Paragraph NB-5111 (ASME Class 1)

Radiographic examination shall be in accordance with Section V, Article 2, except that fluorescent screens are not permitted, the geometric unsharpness shall not exceed the limits of T-285, and the penetrameters of Table NB-5111-1 shall be used in lieu of those shown in Table T-276. [ASME Section V]

Table NB-51 11-1 only refers to use of hole-type penetrameters; use of wire-type penetrameters is not addressed.

Paragraph NC-51 11 (ASME Class 2) of ASME Section III, 1992 Edition Radiographic examination shall be in accordance with Section V, Article 2, except that fluorescent screens are not permitted, the geometric unsharpness shall not exceed the limits of T-285, and the penetrameters of Table NC-51 11-1 shall be used in lieu of those shown in Table T-276. [ASME Section V]

Attachment NOC-AE-06002031 Page 2 of 3 Table NC-51 11-1 only refers to use of hole-type penetrameters; use of wire-type penetrameters is not addressed.

4.0

Reason for Request

Hole-type penetrameters can be difficult to use due to their physical placement during radiography and their radiograph characteristics.

The recorded radiographic characteristics are often obscured or distorted due to specimen anomalies, part geometry, or film artifacts outside the area of interest. These difficulties may result in re-shoots, and re-shoots have potential for additional radiation exposure to the radiography crew. Additionally, use of hole-type penetrameters, with their associated stringent placement and shim requirements, has a direct ALARA impact when performing radiography in a nuclear power environment. This impact is created by the extended time spent in the radiation field for set-up of shim blocks and pipe standards.

When a hole-type penetrameter does not have a good fit adjacent to or across the area of interest, movement of the inspection media can occur. Movement renders the exposure useless, making it necessary to set-up again and re-shoot the weld view.

5.0 Proposed Alternative Pursuant to the provisions of 10 CFR 50.55a(a)(3)(i), STP proposes an alternative to the hole-type penetrameter selection of Tables NB-51 11-1 (ASME Class 1) and NC-5111-1 (ASME Class 2) in the ASME Section III, 1992 Edition, no addenda. Wire-type penetrameters as referenced in Tables NB-51 11-1 and NC-51 11-1 of ASME Section III, 1992 Edition, 1993 Addenda, are proposed used for performing radiographic examinations. Although not specified in the 1993 Addenda, wire-type penetrameters are also to be an alternative to hole-type penetrameters in ASME Class 3 applications.

6.0 Basis for Use Wire-type penetrameters provide the same function as hole-type penetrameters by indicating changes in thickness and spatial resolution of the image. The one-inch minimum length of the wire eliminates the problem of indicator loss due to distortion, anomalies, and part geometry that is commonly found with the target hole in plaque type penetrameters. For more complex configurations, wire-type penetrameters are superior in that placement is directly across the area of interest, encompassing the object's range of density and geometry without using shim blocks and pipe standards.

Wire-type penetrameters have shown sensitivity equivalent to that of hole-type penetrameters as documented in Table 4 of ASME Section V, Article 22, Standard SE-747. Because of its equivalent sensitivity, a wire-type penetrameter will provide results equivalent to those of a hole-type penetrameter.

Therefore, the proposed alternative will maintain the quality of the examination results.

Penetrameter requirements for performing radiography are specified by Tables NB-5111-1 (ASME Class 1) and NC-5111-1 (ASME Class 2) of ASME Section III, 1992 Edition. Based on these tables, only hole-type penetrameters can be used. Wire-type penetrameters are not included in the 1992 Edition of Section III.

However, Tables NB-5111-1 and NC-5111-1 were revised in the 1992 Edition, 1993 Addenda of ASME Section III to include wire-type penetrameter requirements. The 1992 Edition with 1993 Addenda of ASME Section III, which includes the provision for use of equivalent wire-type penetrameters, is endorsed by the NRC in 10 CFR 50.55a. Consequently, as of the 1993 Addenda to Section III, wire-type penetrameters are acceptable for use when performing radiography.

Attachment NOC-AE-06002031 Page 3 of 3 The proposed alternative to use wire-type image quality indicators for radiography examinations as provided for in ASME Section III, 1992 Edition with 1993 Addenda, provides an acceptable level of quality and safety. Therefore, STPNOC requests that application of the proposed alternative at the South Texas Project be authorized pursuant to 10 CFR 50.55a(a)(3)(i).

7.0 Duration of Proposed Alternative STPNOC requests that the staff approve the use of RR-ENG-2-45 by August 2, 2006, to support scheduling for the Unit 1 refueling outage in October 2006.

Once approved, this alternative will be available for use for the duration of the second inspection interval.

The second inservice inspection interval for the South Texas Project commenced on September 25, 2000, for Unit 1, and October 19, 2000, for Unit 2.

8.0 Precedents The NRC staff has approved wire-type penetrameters for use at Calvert Cliffs Nuclear Power Plant, Units 1 and 2, and Indian Point Energy Center, Unit 2. Approvals of their applications were provided as follows:

Calvert Cliffs, Units 1 and 2 Submitted:

September 27, 2001 Approved:

December 19, 2001 TAC Nos. MB3073 and MB3074 Indian Point, Unit 2 Submitted:

September 20, 2000 Approved:

November 28, 2000 TAC No. MB0032