NRC Security Baseline Inspection Report 05000440-06-018 (DRS)
ML061660295
Person / Time
Site: Perry 
Issue date: 06/13/2006
From: Kenneth Riemer
Plant Support Branch II
To: Pearce L
FirstEnergy Nuclear Operating Co
References
IR-06-018
Download: ML061660295 (5)


See also: IR 05000440/2006018

Text

OFFICIAL USE ONLY

Enclosure Contains Sensitive Unclassified

Non-Safeguards Information. Upon

separation, this page is decontrolled.

OFFICIAL USE ONLY

June 13, 2006

Mr. L. William Pearce

Vice President

FirstEnergy Nuclear Operating Company

Perry Nuclear Power Plant

10 Center Road, A290

Perry, OH 44081

SUBJECT:

PERRY NUCLEAR POWER PLANT

NRC SECURITY BASELINE INSPECTION REPORT 05000440/2006018(DRS)

Dear Mr. Pearce:

On May 19, 2006, the US Nuclear Regulatory Commission (NRC) completed a security

baseline inspection at your Perry Nuclear Power Plant. The inspection covered one or more of

the key attributes of the security cornerstone of the NRCs Reactor Oversight Process. The

enclosed inspection report documents the inspection results, which were discussed on May 19,

2006, with you and other members of your staff.

The inspection examined activities conducted under your license as they relate to security and

compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed

personnel.

No findings of significance were identified.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be

available electronically for public inspection in the NRC Public Document Room or from the

Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS

is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public

EXEMPT FROM PUBLIC DISCLOSURE

May be exempt from public release under the Freedom of

Information Act (5 U.S.C. 552)

Exemption number: 5

Nuclear Regulatory Commission review required before public

release.

Joseph Maynen, RIII/DRS/PSB

Name and organization of person making determination.

Date of determination: 05/25/06

OFFICIAL USE ONLY

OFFICIAL USE ONLY

Enclosure Contains Sensitive Unclassified

Non-Safeguards Information. Upon

separation, this page is decontrolled.

L. Pearce

-2-

Electronic Reading Room). However, because of the security-related concerns contained in the

enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be

available for public inspection.

Should you have any questions concerning this inspection, we will be pleased to discuss them

with you.

Sincerely,

/RA by T. Madeda acting for/

Kenneth Riemer, Chief

Plant Support Branch

Division of Reactor Safety

Docket No. 50-440

License No. NPF-58

Enclosure:

Inspection Report 05000440/2006018(DRS)

w/Attachment: Supplemental Information

cc w/encl:

B. Westreich (NSIR/DNS)

NSIR/DNS/RSS/Licensing Assistant

Ohio State Liaison Officer

OFFICIAL USE ONLY

OFFICIAL USE ONLY

Enclosure Contains Sensitive Unclassified

Non-Safeguards Information. Upon

separation, this page is decontrolled.

L. Pearce

-2-

Electronic Reading Room). However, because of the security-related concerns contained in the

enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be

available for public inspection.

Should you have any questions concerning this inspection, we will be pleased to discuss them

with you.

Sincerely,

/RA by T. Madeda acting for/

Kenneth Riemer, Chief

Plant Support Branch

Division of Reactor Safety

Docket No. 50-440

License No. NPF-58

Enclosure:

Inspection Report 05000440/2006018(DRS)

w/Attachment: Supplemental Information

cc w/encl:

B. Westreich (NSIR/DNS)

NSIR/DNS/RSS/Licensing Assistant

Ohio State Liaison Officer

DOCUMENT NAME: E:\\Filenet\\ML061660295.wpd

G Publicly Available

G Non-Publicly Available

G Sensitive

G Non-Sensitive

To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy

OFFICE RIII

RIII

RIII

NAME

JMaynen:co

EDuncan

KRiemer

DATE

06/06/06

06/13/06

06/13/06

OFFICIAL RECORD COPY

OFFICIAL USE ONLY

OFFICIAL USE ONLY

Enclosure Contains Sensitive Unclassified

Non-Safeguards Information. Upon

separation, this page is decontrolled.

L. Pearce

-3-

cc w/o encl:

G. Leidich, President - FENOC

J. Hagan, Chief Operating Officer, FENOC

D. Pace, Senior Vice President Engineering and Services, FENOC

Director, Site Operations

Director, Regulatory Affairs

M. Wayland, Director, Maintenance Department

Manager, Regulatory Compliance

G. Halnon, Director, Performance Improvement

J. Shaw, Director, Engineering Department

D. Jenkins, Attorney, FirstEnergy

Public Utilities Commission of Ohio

R. Owen, Ohio Department of Health

OFFICIAL USE ONLY

OFFICIAL USE ONLY

Enclosure Contains Sensitive Unclassified

Non-Safeguards Information. Upon

separation, this page is decontrolled.

L. Pearce

-4-

ADAMS Distribution:

DXC1

SJC4

RidsNrrDirsIrib

GEG

KGO

RJP

CAA1

LSL (electronic IRs only)

C. Pederson, DRS (hard copy - IRs only)

DRPIII

DRSIII

PLB1

JRK1

ROPreports@nrc.gov