ML061640157

From kanterella
Jump to navigation Jump to search
Document Transmittal; J-26060A, Rev. 3, NRC Emergency Response Data System Data Point Library
ML061640157
Person / Time
Site: Callaway Ameren icon.png
Issue date: 06/07/2006
From:
AmerenUE
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
578547 J-26060A, Rev 003
Download: ML061640157 (70)


Text

{{#Wiki_filter:DATE: 06/07/06 TIME: 10:04:53 AMEREN/UE DOCUMENT CONTROL SYSTEM DOCUMENT TRANSMITTAL PAGE: ARDC8801 9 TRANSMITTAL NUMBER: 578547 TO CONTROL NUMBER: 338 TITLE: OTHER DEPT: NUCLEAR REGULATORY COMM. LOCATION: USNRC WASH DC TRANSMITTAL DATE: 20060607 THAN DOC CODE TYPE DOCUMENT NUMBER RETURN ACKNOWLEDGED TRANSMITTAL AND SUPERSEDED DOCUMENTS (IF APPLICABLE) TO: ADMINISTRATION RECORDS AMEREN/UE CALLAWAY PLANT P.O. BOX 620 FULTON, MO 65251 RET ALT ALT REV REV MED COPY MED COPY AFFECTED DOCUMENT R DRAW J-26060A 003 002 C 1 ACKNOWLEDGED BY:DAE DATE:

A230.0036 J-26060A NRC EMERGENCY RESPONSE DATA SYSTEM DATA POINT LIBRARY (FOR REVISIONS AND AFFECTED PAGES SEE REVISION PAGES) REV. APPROVED DATE 0 E. T. Schulte 6/15/92 1 E. T. Schulte 6/25/92 2 4/18/00 3 Lewis Beaty 6/6/02 -t 4 4 4 4 4 4

NRC EMERGENCY RESPONSE DATA SYSTEM DATA POINT LIBRARY J-26060A Rev. 3 REV. AFFECTED PAGES 0 NEW DOCUMENT 1 Page 2 & 9 change SEN0701 units from PCM to % 2 Change Section 2 pages 46, 48, 53-56, and 62 to revise system descriptions. Reference RFR 15126, SCR5929, 6247-6251. 3 Bulk issue for changes to Section 2 pages 15, 16, 17, 18, 44, 48, 53, 54, 55, 56. Reference MP 00-1008A, 00-1013A, SCR 6342, 6388-6391, 7595-7598, 7737, 7739-7742, 7744, 7864-7867.

NRC EMERGENCY RESPONSE DATA SYSTEM DATA POINT LIBRARY J-26060A Rev. 3 TABLE OF CONTENTS Title Critical Safety Function Parameters ERDS Data Point Library section 2 Page Number 1 5

J-26060QA Rev. 3 SECTION 1 CRITICAL SAFETY FUNCTION PARAMETERS 1

J-26060A Rev. 3 CRITICAL SAFETY FUNCTION PARAMETERS COMPUTER UNITS POINT PARAMETER PARAMETER DESCRIPTION REACTIVITY CONTROL NI POWER RNG NI INTER RNG NI SOURC RNG NL NL CORE COOLING REAC VES LEV TEMP CORE EX SUB MARGIN CORE FLOW Nuclear Instruments, Power Range Nuclear Instruments, Intermediate Range Nuclear Instruments, Source Range Post Accident Wide Range Post Accident Source Range AMPS CPS PCM CPS SPDS0059 SPDS 0060 SPDS 0041 SEN0701 SEN0702 Reactor Vessel Water Level Highest Temperature at the Core Exit Saturation Temperature-Highest CET Total Reactor Coolant Flow DEGF DEGF REU0 523 REU0 090 S PDS 0006 REU0 487 STEAM GENERATORS SG LEVEL 1/A SG LEVEL 2/B SG LEVEL 3/C SG LEVEL 4/D SG PRESS 1/A SG PRESS 2/B SG PRESS 3/C SG PRESS 4/D MN FD FL 1/A MN FD FL 2/B MN FD FL 3/C MN FD FL 4/D AX FD FL 1/A AX FD FL 2/B AX FD FL 3/C AX FD FL 4/D HL TEMP 1/A HL TEMP 2/B HL TEMP 3/C HL TEMP 4/D CL TEMP 1/A CL TEMP 2/B CL TEMP 3/C CL TEMP 4/D Steam Generator Steam Generator Steam Generator Steam Generator Steam Generator Steam Generator Steam Generator Steam Generator Stm Gen 1 Stm Gen 2 Stm Gen 3 Stm Gen 4 Stm Gen 1 Stm Gen 2 Stm Gen 3 Stm Gen 4 Stm. Gen 1 Stm Gen 2 Stm Gen 3 Stm Gen 4 Stm Gen 1 Stm Gen 2 Stm Gen 3 Stm Gen 4 (or A) (or B) (or C) (or D) (or A) (or B) (or C) (or D) (or A) (or B) (or C) (or D) (or A) (or B) (or C) (or D) 1 (or A) Water Level 2 (or B) Water Level 3 (or C) Water Level 4 (or D) Water Level 1 (or A) Pressure 2 (or B) Pressure 3 (or C) Pressure 4 (or D) Pressure Main Feedwater Flow Main Feedwater Flow Main Feedwater Flow Main Feedwater Flow Auxiliary FW Flow Auxiliary FW Flow Auxiliary FW Flow Auxiliary FW Flow Inlet Temperature Inlet Temperature Inlet Temperature Inlet Temperature Outlet Temperature Outlet Temperature Outlet Temperature Outlet Temperature PSIG PSIG PSIG PSIG KLB /HR KLB/HR KLB/HR KLB /HR KLB/HR KLB/HR KLB/HR KLB/HR DEGF DEGF DEGF DEGF DEGF DEGF DEGF DEGF REL0404A REL0424A REL0444A REL0464A SPDS0022 SPDS0023 SPDS0024 SPDS0025 SPDS0026 SPDS0027 SPDS0028 SPDS0029 SPDS0054 SPDS0055 SPDS0056 SPDS0 057 SPDS003 0 SPDS003 1 SPDS0032 SPDS0033 SPDS0034 SPDS0035 SPDS0036 SPDS0037 2

J-26060OA Rev. 3 CRITICAL SAFETY FUNCTION PARAMETERS COMPUTER UNITS POINT PARAMETER PARAMETER DESCRIPTION RCS INTEGRITY RCS PRESSURE PRZR LEVEL RCS CHG/MU HP SI FLOW LP SI FLOW CTMNT SMP NR CTMNT SMP WR Reactor Coolant System Pressure Primary System Pressurizer Level Primary System Charging or Makeup Flow High Pressure Safety Injection Flow Low Pressure Safety Injection Flow Containment Sump Narrow Range Level Containment Sumnp Wide Range Level PSIG GPM GPM GPM INCHES INCHES S PDS 0001 REU0 483 REU0 503 REU0 502 REU0 501 LFLO7 02 LFLO701 RADIOACTIVITY CONTROL EFF GAS RAD EFF GAS RAD EFF GAS RAD EFF LIQ RAD COND A/E RAD CNNNT RAD RCS LTDN RAD MAIN SL 1/A MAIN SL 2/B MAIN SL 3/C MAIN SL 4/D Radioactivity of Released Gasses Radioactivity of Released Gasses Radioactivity of Released Gasses Radioactivity of Released Liquids Condenser Air Ejector Radioactivity Radiation Level in the Containment Rad Level of the RCS Letdown Line UCI/ML UCI /ML MR/HR UCI /ML UCI /ML R/HR UCI /ML SPDS0038 GHROO10B FCR0385 HBRO 018 S PDS 0012 SPDS 0011 SJR0 001 Stm Gen 1 (or A) Stm Gen 2 (or B) Stm Gen 3 (or C) Stm Gen 4 (or D) Steam Line Rad Level Steam Line Rad Level Steam Line Rad Level Steam Line Rad Level NL NL NL NL Stm Line A PORV Disch Rad Mon Stm Line B PORV Disch Rad Mon Stm, Line C PORV Disch Rad Mon Stm Line D PORV Disch Rad Mon Stm Gen 1 (or A) Blowdown Rad Level Stm Gen 2 (or B) Blowdown Rad Level Stm Gen 3 (or C) Blowdown Rad Level Stm Gen 4 (or D) Blowdown Rad Level MR/HR MR/HR MR/HR MR/HR ABRO111 ABRO112 ABRO 113 ABRO114 SG BD RAD 1A SG BD RAD 2B SG BD RAD 3C SG BD RAD 4D UCI/ML SPDS0013 CONTAINMENT CONDITIONS CTMNT PRESS CTMNT TEMP H2 CONC Containment Pressure Containment Temperature Containment Hydrogen Concentration PSIG DEGF S PDS 0008 S PDS 0007 S PDS 0053 3

J-26060QA Rev. 3 CRITICAL SAFETY FUNCTION PARAMETERS COMPUTER UNITS POINT PARAMETER PARAMETER DESCRIPTION MISCELLANEOUS PARAMETERS BWST LEVEL WIND SPEED WIND SPEED WIND DIR WIND DIR STAB CLASS Borated Water Storage Tank Level Wind Speed at the Reactor Site Wind Speed at the Reactor Site Wind Direction at the Reactor Site Wind Direction at the Reactor Site Air Stability at the Reactor Site MIS M/S DEGFR DEGFR STABI REU0 511 RDS0010P RDS0060P RDZ 0710 P RDZ0760P RSTXOOOP 4

J-2606 QA Rev. 3 SECTION 2 ERDS DATA POINT LIBRARY 5

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,-,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10 /01 /91 Cwl N/A NI POWER RNG SPDS0059 POWER RANGE POWER LEVEL NUCLEAR INSTR POWER RANGE A EACH 1% EQUALS APROX. 12 MW

0. OOOE+00
1. 200E+02 N/A N/A P

4 AVERAGE REACTOR CAVITY N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 6

J -2606 0A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A NI INTER RNG SPDS 0060 INTERMEDIATE RANGE POWER LEVEL NUCLEAR INSTR INTERMEDIATE RANGE A AMPS N/A

1. OOOE-11
1. OOOE-03 N/A N/A P

2 AVERAGE REACTOR CAVITY N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 7

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Des c: Analog/Digital: Engr Units/Dig States: Engr units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,.,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/20/92 CWl N/A NI SOURC RNG SPDS 0041 SOURCE RANGE POWER LEVEL NUCLEAR INSTR SOURCE RANGE A CPS N/A

2. 500E-01 1.OOOE+06 N/A N/A P

2 AVERAGE REACTOR CAVITY N/A 1E-10 AMPS >1E-10 AMPS LOW N/A N/A MAY FAIL HIGH. 8

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply '\\,,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A NL SEN0701 POST ACCIDENT WIDE RANGE POST ACCIDENT WIDE RANGE A POM PERCENT

  • E-03
1. OOOE-08 2.OOOE+02 N/A N/A P

2 AVERAGE REACTOR CAVITY N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 9

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ýCut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A NL SEN07 02 POST ACCIDENT SOURCE RANGE POST ACCIDENT SOURCE RANGE A CPS N/A 1.OOOE-01

1. OOOE+05 N/A N/A P

2 AVERAGE REACTOR CAVITY N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 10

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Des c: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: -Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CWl N/A REAC yES LEV REU0 523 RV WR A/B LEVEL AVG REACTOR VESSEL WATER LEVEL A TOTAL INSIDE FLUID HEIGHT 494.9 INCHES -2.500E+00

1. 250E+02 COMPLX BOTTOM OF VESSEL P

2 AVERAGE REACTOR VESSEL N/A N/A N/A LOW Y WET USES DIFFERENTIAL PRESSURE ACROSS THE VESSEL TO DETERMINE VESSEL LEVEL OR RELATIVE VOID CONTENT OF THE CIRCULATING PRIMARY COOLANT SYSTEM4 FLUID. MAY FAIL HIGH. 11

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply '~cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A TEMP CORE EX REU0090O INSTANT T AUCT ICORE T/C HIGHEST TEMP AT CORE EXIT A DEGF N/A 0.OOOE+00

2. 300E+03 N/A N/A P

50 MAXIMUM REACTOR VESSEL N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 12

J-2 6060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ý.Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A SUB MARGIN SPDS0006 RCS COOLANT SUBCOOLING SATURATION TEMP - HIGHEST CET A DEGF N/A -2.OOOE+02 2.OOOE+03 N/A N/A P 4 AVERAGE OF LOWEST VALUE FROM EACH TRAIN REACTOR VESSEL N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 13

J-26060OA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ý,ýCut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CORE FLOW REU0 487 REACTOR COOLANT LOOP AVE FLOW TOTAL REACTOR COOLANT FLOW A EACH 1% EQUALS APROX. 1.394E+06 LB/HR 0.OOOE+00 1.200E+02 N/A N/A P 12 AVERAGE CROSSOVER LEG N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 14

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 cW1 N/A SG LEVEL 1/A REL0404A SG A WR LEVEL STEAM GEN A WATER LEVEL A 100% = 586.9 INCHES 0.OOOE+00

1. OOOE+02 TUBSHT 13 INCHES ABOVE TUBE SHEET S

1 N/A STEAM GENERATOR A HIHI/HI /LO /LOLO 97 /92 /NA /NA (Plant mode 1-3) 97 /92 /87 /NA (Plant mode 4) NA /NA /87 /NA (Plant mode 5-6) N/A N/A LOW Y WET 73.3% IS TOP OF HIGHEST TUBE. MAY FAIL HIGH. 15

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg Unique System Desc: 10/31/2005 CW1 N/A SG LEVEL 2/B REL0424A SG B WR LEVEL STEAM GEN B WATER LEVEL A 100% = 586.9 INCHES 0.OOOE+O0 1.000E+02 TUBSHT 13 INCHES ABOVE TUBE SHEET S 1 N/A STEAM GENERATOR B HIHI/HI /LO /LQLO 97 /92 /NA /NA (Plant mode 1-3) 97 /92 /87 /NA (Plant mode 4) NA /NA /87 /NA (Plant mode 5-6) N/A N/A LOW Y WET 73.3% IS TOP OF HIGHEST TUBE. MAY FAIL HIGH. 16

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CW1 N/A SG LEVEL 3/C REL0444A SG C WR LEVEL STEAM GEN C WATER LEVEL A 100% = 586.9 INCHES 0.OOOE+00

1. OOOE+02 TUBSHT 13 INCHES ABOVE TUBE SHEET S

1 N/A STEAM GENERATOR C HIHI/HI /LO /LOLO 97 /92 /NA /NA (Plant mode 1-3) 97 /92 /87 /NA (Plant mode 4) NA /NA /87 /NA (Plant mode 5-6) N/A N/A LOW Y WET 73.3% IS TOP OF HIGHEST TUBE. MAY FAIL HIGH. 17

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CW1 N/A SG LEVEL 4/D REL0464A SG D WR LEVEL STEAM GEN D WATER LEVEL A 100% = 586.9 INCHES

0. OOOE+00 1.OOOE+02 TUBSHT 13 INCHES ABOVE TUBE SHEET S

1 N/A STEAM GENERATOR D HIHI/HI /LO /LOLO 97 /92 /NA /NA (Plant mode 1-3) 97 /92 /87 /NA (Plant mode 4) NA /NA /87 /NA (Plant mode 5-6) N/A N/A LOW N/A N/A 73.3% IS TOP OF HIGHEST TUBE. MAY FAIL HIGH. 18

J -26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply v,,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A SG PRESS 1/A S PDS 0022 STEAM GENERATOR A PRESSURE STEAM GENERATOR A PRESSURE A PSIG N/A 0.OOOE+00 1.300E+03 N/A N/A P 3 AVERAGE SECONDARY SIDE DOWNSTREAM SG A N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 19

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr units Conversion: Minimum Instr Range: maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,_Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A SG PRESS 2/B SPDS0023 STEAM GENERATOR B PRESSURE STEAM GENERATOR B PRESSURE A PSIG N/A 0.OOOE+00

1. 300E+03 N/A N/A P

3 AVERAGE SECONDARY SIDE DOWNSTREAM SG B N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 20

J-26060OA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A SQ PRESS 3/B SPDS 0024 STEAM GENERATOR C PRESSURE STEAM GENERATOR C PRESSURE A PSIG N/A 0.OOOE+00

1. 300E+03 N/A N/A P

3 AVERAGE SECONDARY SIDE DOWNSTREAM SG C N/A N/A N/A LOW y N/A MAY FAIL HIGH. 21

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ý,_Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A SG PRESS 4/D SPDS 0025 STEAM GENERATOR D PRESSURE STEAM GENERATOR D PRESSURE A PSIG N/A 0.OOOE+00

1. 300E+03 N/A N/A P

3 AVERAGE SECONDARY SIDE DOWNSTREAM SG D N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 22

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A MN FD FL 1/A SPDS0026 STEAM GEN A FEEDWATER FLOW STM GEN A MAIN FEEDWATER FLOW A KLB/HR N/A

0. OOOE+00 5.OOOE+03 N/A N/A P

2 AVERAGE FROM FEEDWATER SYSTEM UPSTREAM SG A N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 23

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply K,.Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A MN FD FL 2/B SPDS 0027 STEAM GEN B FEEDWATER FLOW STM GEN B MAIN FEEDWATER FLOW A KLB/HR N/A

0. OOOE-i0O
5. OOOE+03 N/A N/A P

2 AVERAGE FROM FEEDWATER SYSTEM UPSTREAM SG B N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 24

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A MN FD FL 3/C SPDS0028 STEAM GEN C FEEDWATER FLOW 5Th GEN C MAIN FEEDWATER FLOW A KLB/HR N/A 0.OOOE+00 5.OOOE+03 N/A N/A P 2 AVERAGE FROM FEEDWATER SYSTEM UPSTREAM SG C N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 25

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A MN FD FL 4/D SPDS 0029 STEAM GEN D FEEDWATER FLOW STM GEN D MAIN FEEDWATER FLOW A KLB/HR N/A 0.OOOE+00 5.OOOE+03 N/A N/A P 2 AVERAGE FROM FEEDWATER SYSTEM UPSTREAM SG D N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 26

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point TD: Plant Spec Point Desc: Gener ic/Cond Desc: Anal-og.'Digital: Engr Units/Dig States: Engr Units Conversion: Minn~rr nstr Range: Maý:,,:r.Ti Instr Range: Zers,Ti

Reference:

Re,`ei-n(ce, Point Notes: PFP" ý 3ENS: Nu!-',-- cfr Sensors: Ho-.- , sed: Se-,.- 1-c~a t ions: AiF:. ipSet Points: NI '1/2~trPower Supply ý,ý,C w 'Th-wer Level: NI K itrPower Supply Tu. Power Level: in:' r ~Failure Mode: Teil,ýý r Compensation Fo.: >d -aTimitters: Lev- [F

Kerence Leg:

Uni,!;! '.'stem. Desc: 10/01/91 CW1 N/A AX FD FL 1/A S PDS 0054 STEAM GEN A AUX FEEDWATER FLOW STh GEN A AUXILIARY FW FLOW A KLB/HR N/A 0.OOOE+0O 2.OOOE+02 N/A N/A S 1 N/A FROM AUX FEEDWATER SYSTEM UPSTREAM SG A N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 27

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply k~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A AX FD FL 2/B SPDS 0055 STEAM GEN B AUX FEEDWATER FLOW STM GEN B AUXILIARY FW FLOW A KLB/HR N/A 0.OOOE+00 2.OOOE+02 N/A N/A S 1 N/A FROM AUX FEEDWATER SYSTEM UPSTREAM SG B N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 28

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A AX FD FL 3/C SPDS 0056 STEAM GEN C AUX FEEDWATER FLOW STM GEN C AUXILIARY FW FLOW A KLB/HR N/A 0.OOOE-i00 2.OOOE+02 N/A N/A S 1 N/A FROM AUX FEEDWATER SYSTEM UPSTREAM SG C N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 29

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply y,.~.Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A AX FD FL 4/D SPDS0057 STEAM GEN D AUX FEEDWATER FLOW STh GEN D AUXILIARY FW FLOW A KLB/HR N/A 0.OOOE+00 5.OOOE+03 N/A N/A S 1 N/A FROM AUX FEEDWATER SYSTEM UPSTREAM SG D N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 30

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ,,,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A HL TEMP 1/A S PDS 0030 HOT LEG TEMPERATURE, LOOP 1 STh GEN A INLET TEMPERATURE A DEGF N/A O.OOOE+00 7.OOOE+02 N/A N/A S 1 N/A LOOP N/A 1 HOT LEG N/A N/A LOW N/A N/A MAY FAIL HIGH. 31

J-26060OA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\ Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A HL TEMP 2/B SPDS 0031 HOT LEG TEMPERATURE, LOOP 2 STM GEN B INLET TEMPERATURE A DEGF N/A 0.OOOE+00 7.OOOE+02 N/A N/A S 1 N/A LOOP 2 HOT LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 32

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\~Cut-of f Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A HL TEMP 3/C SPDS0032 HOT LEG TEMPERATURE, LOOP 3 STM GEN C INLET TEMPERATURE A DEGF N/A 0.OOOE+00 7.OOOE+02 N/A N/A S 1 N/A LOOP 3 HOT LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 33

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A HL TEMP 4/D S PDS 0033 HOT LEG TEMPERATURE, LOOP 4 5TM GEN D INLET TEMPERATURE A DEGF N/A 0.OO0E+00 7.OOOE+02 N/A N/A S I. N/A LOOP N/A 4 HOT LEG N/A N/A LOW N/A N/A MAY FAIL HIGH. 34

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ý,.Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 ewi N/A CL TEMP 1/A SPDS0034 COLD LEG TEMPERATURE, LOOP 1 STh GEN A OUTLET TEMPERATURE A DEGF N/A 0.OOOE+0Q 7.OOOE+02 N/A N/A S 1 N/A LOOP 1 COLD LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 35

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply %ý.,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CL TEMP 2/B S PDS 0035 COLD LEG TEMPERATURE, LOOP 2 STM GEN B OUTLET TEMPERATURE A DEGF N/A

0. OOOE+00 7.OOOE+02 N/A N/A S

1 N/A LOOP 2 COLD LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 36

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr UnitsiDig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply '.~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CL TEMP 3/C SPDS003 6 COLD LEG TEMPERATURE, LOOP 3 STM GEN C OUTLET TEMPERATURE A DEGF N/A O.OOOE+00 7.OOOE+02 N/A N/A S 1 N/A LOOP 3 COLD LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 37

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply SCut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CL TEMP 4/D S PDS 0037 COLD LEG TEMPERATURE, LOOP 4 STh GEN D OUTLET TEMPERATURE A DEGF N/A 0.OOOE+00 7.OOOE+02 N/A N/A S 1 N/A LOOP 4 COLD LEG N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 38

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: .Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ,,_,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A RCS PRESSURE SPDS 0001 RCS PRESSURE REACTOR COOLANT SYSTEM PRESSURE A PSIG N/A

0. OOOE+0O 3.OOOE+03 N/A N/A P

2 AVERAGE TUBING FROM REACTOR VESSEL N/A N/A N/A LOW y N/A MAY FAIL HIGH. 39

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 Cwl N/A PRZR LEVEL REU0483 PRESS LEVEL 1/2/3 AVG PRIMARY SYSTEM PRESSURIZER LEVEL A 100% = 555 INCHES 0.OOOE+00 1.OOOE+02 COMPLX 40 INCHES ABOVE P]ýESSURIZER BOTTOM P 3 AVERAGE PRES SURI ZER N/A N/A N/A LOW Y WET PRESSURIZER VOLUME IS 1800 CUBIC FEET. HEATER TOPS AT 17.5% LEVEL. MAY FAIL HIGH. 40

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A RCS CHG/MU REU0 503 CHARGING PUMP SI FLOW PRI SYS CHARGING OR MAKEUP FLOW A GPM N/A 0.OOOE+00

1. 140E+03 N/A N/A P

2 sum UPSTREAM OF CENTRIFUGAL CHARGING PUMP N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 41

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply K,ýCut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A HP SI FLOW REU0 502 SI PUMP DISCHARGE FLOW HI PRESS SAFETY INJECTION FLOW A GPM N/A 0.OOOE+00 1.600E+03 N/A N/A P 2 sum DOWNSTREAM SI PUMPS N/A N/A N/A LOW Y N/A MAY FAIL HIGH-42

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,,.Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A LP SI FLOW REU0501 RHR FLOW LO PRESS SAFETY INJECTION FLOW A GPM N/A 0.OOOE+00 1.450E+04 N/A N/A P 3 sum DOWNSTREAM RHR PUMPS N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 43

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,-/Cut-of f Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CW1 N/A CTMNT SMP NR LFLO7 02 CONTAINMENT SUMP NR LEVEL CONTAINMENT SMP NARROW RANGE LVL A INCHES 9.77 GAL/INCH

1. 175E+01
2. 575E+01 TNKBOT N/A P

2 MAXIMUM CONTAINMENT NORMAL SUMPS N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 44

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point. ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,-,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Comnpensat ion For DP Transmitters: Level Reference Leg: Unique System Desc: 10 /01 /91 CWl N/A CTNNT SMP WR LFLO701 CONTAINMENT SUMP WR LEVEL CONTAINM4ENT SMP WIDE RANGE LVL A INCHES 41.6 GAL/INCH

0. OOOE+00
1. 560E+02 TNKBOT N/A P

2 MAXIMUM CONTAINMENT RECIRC SUMPS N/A N/A N/A LOW Y N/A MAY FAIL HIGH. 45

J-26060GA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Des c: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\,-,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/18/2000 CWl N/A EFF GAS RAD .SPDS 0038 STACK EFFLUENT RADIATION RADIOACTIVITY OF RELEASED GASSES A UCI/ML N/A 1.OOOE-07

1. OOOE+05 N/A N/A S

1 N/A UNIT VENT DWNSTRM LAST PNT OF RAD ENTRY N/A N/A N/A LOW N/A N/A UNIT VENT NOMINAL FLOW RATES (CFM) 16500 MN STM ENCLOSURE BLD EXHAUST 32000 FULL SPEED AUX/FUEL BLD EXHAUST 12000 SLOW SPEED 6300 ACCESS CONTROL 1000 COND AIR REMOVAL FILTRATION 20000 CONT. SHUTDOWN PURGE EXHAUST 4000 CONT. MINIPURGE EXHAUST 9000 FUEL BLD EMERG EXHAUST ALERT/HIGH ALARMS PER ODOM ON RMS RN-li. MAY FAIL HIGH. 46

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CWl N/A EFFS GAS RAD GHRO01 B RADWASTE VENT GAS HAD MON RADIOACTIVITY OF RELEASED GASSES A UCI/ML 2.039E+10 ML/HR 1.OOOE-07 1.OOOE+05 N/A N/A S 1 N/A DOWNSTREAM OF EXHAUST FILTER AND FANS N/A N/A N/A LOW N/A N/A MONITORS GASEOUS RADIOACTIVITY IN THE EFFLUENT RADWASTE BUILDING DUCT. ISOLATES WASTE GAS DECAY TANK DISCHARGE LINE ON HIGH ALARM. FLOW IS 12000 SCFM. ALERT/HIGH ALARMS PER ODCM ON RMS RM-1l. MAY FAIL HIGH. 47

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: ý,NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 11/04/2 005 CW1 N/A EFFS GAS RAD FCR03 85 AUX FDWTR TURBINE DISCH RAI) MON RADIOACTIVITY OF RELEASES GASSES A MR/HR, N/A

1. OOOE-02 1.OOOE+05 N/A N/A S

1 N/A VIEWS PLUME FROM TURBINE EXHAUST HIHI / HI /LO /LOLO 8.50E2 /1.5E2 /NA /NA N/A N/A LOW N/A N/A MULTIPLY VALUE BY 5.51E-02 TO CONVERT UNITS TO UCI/ML. THIS CONVERSION FACTOR TAKES INTO CONDIDERATION PLUME SIZE AND DISTANCE FACTORS. MAY FAIL HIGH. 48

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States:- Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ý,Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CWl N/A EFF LIQ HAD HBROO18 RADWASTE LIQUID DIS HAD MON RADIOACTIVITY OF RELEASED LIQUID A UCI/ML MAX 2.082E+06 ML/MIN

1. OOOE-07 9.990E-02 N/A N/A S

1 N/A UPSTREAM OF DISCHARGE VALVE N/A N/A N/A LOW N/A N/A HIGH RADIOACTIVITY ALARM CLOSES THE LIQUID RADWASTE SYSTEM DISCHARGE VALVE. FLOW IS 0-550 GPM. ALERT/HIGH ALARMS PER ODCM ON EMS RM-il. MAY FAIL HIGH. 49

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: FILTERS Alarm/Trip Set Points: ~NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CW1 N/A COND A/E RAD SPDS0012 CONDENSER AIR DISCHARGE RAD CONDESER AIR EJECTOR RAD A UCI/ML 1.699E+09 ML/HR 1.OOOE-07

1. OOOE-02 N/A N/A S

1 N/A UPSTREAM OF COND AIR REMOVAL SYS N/A N/A N/A LOW N/A N/A THIS MONITOR CLOSES STEAM GENERATOR BLOWDOWN ISOLATION VALVE ON HIGH ALARMS. DISCHARGES THROUGH UNIT VENT. FLOW IS 1000 SCFM. ALERT/HIGH = 2.OE-06/2.OE-05 UCI/ML ON RMS RM-11. MAY FAIL HIGH. 50

J-26060OA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: ~NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CNTMNT HAD SPDS 0011 CONTAINMENT RADIATION RADIATION LEVEL IN CONTAINMENT A R/HR N/A

1. OOOE-O1 1.OOOE+08 N/A N/A P

2 MAXIMUM INSIDE SURFACE OF CONTAINMENT WALL N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 51

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CWl N/A RCS LTDN RAD S9JROO0l CVCS LETDOWN RAD MON RAD LVL OF RCS LETDOWN LINE A UCI/ML MAX 640 ML/MIN 1.OOOE-03

1. 700E+03 N/A N/A S

1 N/A UPSTREAM OF CVCS LETDOWN DEMINERALIZERS N/A N/A N/A LOW N/A N/A VARIABLE ALERT/HIGH ALARMS ON RMS RM-11. MAY FAIL HIGH. 52

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: ~NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CW1 N/A NL ABRO 111 STh LINE A PORV DISCH RAD MON STM LINE A PORV DISCH RAD MON A MR/HR N/A 1.OOOE-02 1.OOOE+05 N/A N/A S 1 N/A VIEWS PLUME FROM SG A PORV HIHI /HI/LO/LOLO

1. 46E2/27/NA/NA N/A N/A LOW N/A N/A MULTIPLY VALUE BY 4.06E-02 TO CONVERT UNITS TO UCI/ML. THIS CONVERSION FACTOR TAKES INTO CONSIDERATION PLUME SIZE AND DISTANCE FACTORS.

MAY FAIL HIGH. 53

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analo g/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: \\,_,NI Detector Power Supply Cut-of f Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CW1 N/A N/A ABRO112 STh LINE B PORV DISCH RAD MON STh LINE B PORV DISCH RAD MON A MR/HR N/A 1.OOOE-02 1.OOOE+05 N/A N/A S 1 N/A VIEWS PLUME FROM SG B PORV HIHI /HI/LO/LOLO

1. 46E2/27/NA/NA N/A N/A LOW N/A N/A MULTIPLY VALUE By 4.06E-02 TO CONVERT UNITS TO UCI/ML. THIS CONVERSION FACTOR TAKES INTO CONSIDERATION PLUME SIZE AND DISTANCE FACTORS.

MAY FAIL HIGH. 54

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr units conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: ASIDetector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2005 CWl N/A NL ABRO113 STM LINE C PORV DISCH RAD MON STM LINE C PORV DISCH RAD MON A MR/HR N/A 1.OOOE-02 1.OOOE+05 N/A N/A S 1 N/A VIEWS PLUME FROM SG C PORV HIHI /HI/LO/LOLO

1. 46E2/27/NA/NA N/A N/A LOW N/A N/A MULTIPLY VALUE BY 4.06E-02 TO CONVERT UNITS TO UCI/ML. THIS CONVERSION FACTOR TAKES INTO CONSIDERATION PLUME SIZE AND DISTANCE FACTORS.

MAY FAIL HIGH. 55

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Numiber of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: '~NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/31/2 005 owl N/A NL ABRO114 STh LINE D PORV DISCH RAD MON 5Th LINE D PORV DISCH RAD MON A HR/HR N/A

1. OOOE-02 1.OOOE+05 N/A N/A S

1 N/A VIEWS PLUME FROM SG D PORV HIHI /HI/LO/LOLO

1. 46E2/27/NA/NA N/A N/A LOW N/A N/A MULTIPLY VALUE BY 4.06E-02 TO CONVERT UNITS TO UCI/ML. THIS CONVERSION FACTOR TAKES INTO CONSIDERATION PLUME SIZE AND DISTANCE FACTORS.

MAY FAIL HIGH. 56

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CW1 N/A SG BDRAD 1A SPDS0013 STM GEN BLOWDOWN RADIATION STM GEN BLOWDOWN RADIATION LEVEL A UCI/ML MAX 640 ML/MIN

1. OOOE-07
1. OOOE-02 N/A N/A S

1 N/A DOWNSTREAM OF SAMPLE SYS HEAT EXCHANGER N/A N/A N/A LOW N/A N/A MONITOR CLOSES STEAM GENERATOR BLOWDOWN ISOLATION TO PREVENT THE DISCHARGE OF RADIOACIVE FLUID AND TO LIMIT RADIAOCTIVE CONTAMINATION OF THE BLOWDOWN DEMINERALIZERS. MONITORS DOWNSTREAM COMB OF 4 LOOPS. RMS RM-11 ALERT/HIGH ALARMS-1.OE-05/l.OE-04 UCI/ML. MAY FAIL HIGH. 57

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERflS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A CTMNT PRESS SPDS0008 CONTAINMENT PRESSURE CONTAINMENT PRESSURE A PSIG N/A Q.OOOE+00

6. 900E+01 N/A N/A P

3 AVERAGE CONTAINMENT BLDG 2026' ELEVATION N/A N/A N/A LOW y N/A MAY FAIL HIGH. 58

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NIDetector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CW1 N/A CTMNT TEMP SPDS 0007 CONTAINMENT CONTAINMENT A DEGF N/A 0.OOOE+00 4.OOOE+02 N/A N/A p 4 TEMPERATURE TEMPERATURE AVERAGE CONTAINMENT BLDG 2047' ELEVATION N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 59

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: 'NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CWl N/A H2 CONC SPDS0053 CONTAINMENT HYDROGEN CONC CONTAINMENT HYDROGEN CONC A CONTAINMENT VOLUME = 2.5E+06 CUBIC FEET 0.OOOE+00 1.OOOE+01 N/A N/A p 2 AVERAGE CONTAINMENT BLDG 2047' ELEVATION N/A N/A N/A LOW N/A N/A MAY FAIL HIGH. 60

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply \\Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/09/92 CW1 N/A BWST LEVEL REU0 511 RWST LEVEL BORATED WATER STORAGE TANK LEVEL A 100% = 419445 GALLONS 0.OOOE+O0 1.OOOE+02 COMPLX 0% = 18722 GALLONS P 4 AVERAGE REFUELING WATER STORAGE TANK N/A N/A N/A LOW Y WET MAY FAIL HIGH. 61

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: \\NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 04/18/2000 CW1 N/A WIND SPEED RDS 0010 P PRI MET TOWER 10M WIND SPEED WIND SPEED AT REACTOR SITE A M/S N/A

0. OOOE+00
5. OOOE+01 N/A N/A S

1 N/A PRIMARY MET TOWER AT 10 METERS ELEVATION HIHI/HI/LO/LOLO 26 /NA/NA/NA N/A N/A LOW N/A N/A 62

J-26060QA Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: ELEVATION Alarm/Trip Set Points: NI Detector Power Supply Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 CWl N/A WIND SPEED RDS0060P PRI MET TOWER 60M WIND SPEED WIND SPEED AT REACTOR SITE A M/S N/A 0.OOOE+00 5.OOOE+01 N/A N/A S 1 N/A PRIMARY MET TOWER AT 60 METERS N/A N/A N/A LOW N/A N/A 63

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: ELEVATION Alarm/Trip Set Points: NI Detector Power Supply v'Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/ 91 CW1 N/A WIND DIR RDZ0710P PRI MET TOWER*lOM WIND DIRECTION WIND DIRECTION AT REACTOR SITE A DEGFR N/A

0. OOOE+00 3.600E+02 N/A N/A S

I N/A PRIMARY MET TOWER AT 10 METERS N/A N/A N/A LOW N/A N/A MEASURED IN THE "FROM" DIRECTION. 0 DEG = NORTH. MAY FAIL IN ANY MODE. 64

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: ELEVATION Alarm/Trip Set Points: NI Detector Power Supply '1-'Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10/01/91 ewi N/A WIND DIR RDZ0760P PRI MET TOWER 60M WIND DIRECTION WIND DIRECTION AT REACTOR SITE A DEGFR N/A 0.OOOE+00 3.600E+02 N/A N/A S 1 N/A PRIMARY MET TOWER AT 60 METERS N/A N/A N/A LOW N/A N/A MEASURED IN THE "FROM" DIRECTION. 0 DEG = NORTH. MAY FAIL IN ANY-MODE. 65

J-26060A Rev. 3 DATA POINT LIBRARY REFERENCE FILE Date: Reactor Unit: Data Feeder: NRC ERDS Parameter: Point ID: Plant Spec Point Desc: Generic/Cond Desc: Analog/Digital: Engr Units/Dig States: Engr Units Conversion: Minimum Instr Range: Maximum Instr Range: Zero Point

Reference:

Reference Point Notes: PROC or SENS: Number of Sensors: How Processed: Sensor Locations: Alarm/Trip Set Points: NI Detector Power Supply ~7Cut-off Power Level: NI Detector Power Supply Turn-on Power Level: Instrument Failure Mode: Temperature Compensation For DP Transmitters: Level Reference Leg: Unique System Desc: 10 /01 /91 CWl N/A STAB CLASS RSTXOOOP PRI MET TWR STABILITY AIR STABILITY AT REACTOR SITE A STABI N/A 1.OOOE+00 7.OOOE+00 N/A N/A P 7 N/A PRIMARY MET TOWER N/A N/A N/A LOW N/A N/A STABILITY PRIMARILY BASED ON RATE OF VERTICAL TEMPERATURE CHANGE. IT NOT VALIDATED GOOD, STABILITY IS BASED ON STANDARD DEVIATION OF WIND DIRECTION WHEN WIND SPEEDS ARE ABOVE 1 M/S. VALIDATION CRITERIA USED: STABILITY CLASS DOES NOT CHANGE BY MORE THAN 1 CLASS IN 15 MINUTES OR 2 CLASSES IN 1 HOUR. 1 =EXTREMELY UNSTABLE 2 = MODERATELY UNSTABLE 3 = SLIGHTLY UNSTABLE 4 = NEUTRAL 5 = SLIGHTLY STABLE 6 = MODERATELY STABLE 7 = EXTREMELY STABLE 66}}