ML061460076

From kanterella
Jump to navigation Jump to search
E-mail from Boland to Mitchell, Tritium at Dresden
ML061460076
Person / Time
Site: Dresden  
Issue date: 02/14/2006
From: Boland A
NRC/RGN-II
To: Matthew Mitchell
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0130
Download: ML061460076 (1)


Text

Anne Boland -Re: Tritium at Dresden and Byron Pane From:

Anne Boland To:

Mark Mitchell Date:

2/14/06 1:56PM

Subject:

Re: Tritium at Dresdenland Byron Thanks, Mark.

Anne T. Boland, Deputy Director Division of Reactor Safety NRC Region l1l 630-829-9701

>> Mark Mitchell 02/14/2006 1:33:20 PM >>>

The Dresden sample result on February 11, 2006, was 486,000 picocuries per liter (pCiL), on February 12, 2006 was 529,000 pCi/L and on February 13, 2006 was 680,000 pCi/L. CST tritium concentration is in the neighborhood of 10 million pCi/L.

Excavation of the line underway (2/14) so the numbers may be less meaningful from this point forward and the well may need to be removed during the excavation to get to the pipe.

"> Peter Habighorst 02/13/06 10:51 AM,>> (DE>)

Anne, "I did communicate with Bill Kane...... on both sites....... Just wanted to confirm that the tritium in monitoring well at Dresden was 486K pci/L on Saturday..... if so, what is the CST currently running at for o7tritium....thanks 4