Ltr. 05/23/06 DC Cook Unit 1 & 2 Request for Information for NRC Maintenance Effectiveness Baseline Inspection
ML061440116
Person / Time
Site: Cook  
Issue date: 05/23/2006
From: Julio Lara
Engineering Branch 3
To: Nazar M
Indiana Michigan Power Co, Nuclear Generation Group
References
Download: ML061440116 (6)


Text

May 23, 2006 Mr. M. Nazar Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106

SUBJECT:

D. C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 - INFORMATION REQUEST FOR NRC MAINTENANCE EFFECTIVENESS BASELINE INSPECTION

Dear Mr. Nazar:

On July 17, 2006, the U.S. Nuclear Regulatory Commission (NRC) will begin the required triennial inspection of maintenance effectiveness at your D. C. Cook Nuclear Power Plant, Units 1 and 2. This inspection will be performed in accordance with the NRC baseline inspection procedure 71111.12B.

In order to minimize the impact that the inspection has on the site and to ensure a productive inspection for both sides, we have enclosed a request for documents needed for the inspection.

The document request lists the information necessary in order to ensure the inspector is adequately prepared for the inspection. This information should be available to the Regional Office no later than June 30, 2006. In so far as possible, this information should be provided electronically to the lead inspector.

The lead inspector for this inspection is Mr. Robert Winter. If there are any questions about the material requested, or the inspection, please call the lead inspector at (630) 829-9758 or e-mail him at RAW2@nrc.gov.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public

M. Nazar Document Room or from the Publicly Available Records (PARS) component of the NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Julio Lara, Chief Engineering Branch 3 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74

Enclosure:

Initial Document Request cc w/encl:

J. Jensen, Site Vice President L. Weber, Plant Manager G. White, Michigan Public Service Commission L. Brandon, Michigan Department of Environmental Quality -

Waste and Hazardous Materials Division Emergency Management Division MI Department of State Police D. Lochbaum, Union of Concerned Scientists

M. Nazar document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Julio Lara, Chief Engineering Branch 3 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74

Enclosure:

Initial Document Request cc w/encl:

J. Jensen, Site Vice President L. Weber, Plant Manager G. White, Michigan Public Service Commission L. Brandon, Michigan Department of Environmental Quality -

Waste and Hazardous Materials Division Emergency Management Division MI Department of State Police D. Lochbaum, Union of Concerned Scientists DOCUMENT NAME: E:\\Filenet\\ML061440116.wpd G Publicly Available G Non-Publicly Available G Sensitive G Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII RIII NAME RWinter: ls JLara CLipa DATE 05/18/06 05/23/06 05/23/06 OFFICIAL RECORD COPY

M. Nazar ADAMS Distribution:

JLD PST RidsNrrDirsIrib GEG KGO BJK1 CAA1 DRPIII DRSIII PLB1 JRK1 ROPreports@nrc.gov

Enclosure PERIODIC EVALUATION INSPECTION DOCUMENT REQUEST Inspection Date:

July 17, 2006 Inspection Procedures:

IP 71111.12B, Maintenance Effectiveness, Periodic Evaluation Inspection Inspector:

Robert Winter, Reactor Engineer (630) 829-9758, raw2@nrc.gov Initial Document Request A.

Information Requested Expeditiously The following information is requested to be provided as soon as possible, but no later than June 30, 2006. In so far as possible, information should be provided electronically.

1.

Use these specific systems for Items 3, 11, 15, and 18 of the Document Request List a.

Auxiliary Power (4160 Vac);

b.

Control Rod Drive; c.

Chemical and Volume Control System; and d.

Essential Service Water.

B Document Request 1.

Maintenance Rule Administrative Procedures; 2.

IPE/PSA available for review; 3.

PSA Basis for the Maintenance Rule (MR) Performance Criteria for the following systems: (See items listed above);

4.

Current list of Maintenance Rule Systems Showing (a)(1) and (a)(2) status; 5.

Performance criteria for all SSCs in the MR; 6.

A copy of the last two Periodic Evaluations; 7.

List of Unavailability and Reliability Data used for all MR SSCs in performing the latest Periodic Evaluation (if not included in periodic evaluation report);

Enclosure 8.

Maintenance Rule (a)(1) Cause Determinations and Goals for all SSCs in (a)(1) during the time frame of the latest periodic evaluation; 9.

Disposition sheets for why SSCs removed from (a)(1) during the time frame of the latest periodic evaluation; 10.

List of all SSCs (or functions) removed from or added to the MR program for the time frame of the latest periodic evaluation; 11.

Work Requests (Orders) for SSCs identified above for the time frame of the latest periodic evaluation; 12.

List of all Functional Failures (FF), Maintenance Preventable Functional Failures (MPFFs), and Repetitive Maintenance Preventable Functional Failures (RMPFFs) for the time frame of the latest periodic evaluation (if not included in periodic evaluation report);

13.

List of all Performance Criteria Changes made to MR SSCs for the time frame of the latest periodic evaluation; 14.

Copies of Maintenance Rule Quarterly Reviews for the time frame of the latest periodic evaluation (if they are being performed);

15.

Copies of System Health Report for SSCs identified above; 16.

Audit/Self-assessment of the Maintenance Rule Program performed in the last two years; 17.

Expert Panel Minutes from January 2003 to April 2006; and 18.

Condition Reports/Action Requests (with evaluations and corrective actions) issued for the systems identified above for the time period of the latest periodic evaluation.