GE Energy Nuclear 3901 Castle Hayne Rd Wilmington, NC 28401 GE-NE-0000-0053-85 53-RONP Class I eDRF 0000-0053-8547 May 2006 LASALLE UNITS I AND 2 ROD CONTROL MANAGEMENT SYSTEM (RCMS)
FAILURE MODES AND EFFECTS ANALYSIS
Non-Proprietary Information GE-NE-0000-0053-8553-RONP Sheet 2 of 72 INFORMATION NOTICE This document is a non-proprietary version of GE-NE-0000-0044-6934-ROP which has the proprietary information removed. Portions of the document that have been removed are indicated by an open and closed bracket as shown here ((
)).
IMPORTANT NOTICE REGARDING CONTENTS OF THIS REPORT PLEASE READ CAREFULLY Neither GE nor any of the contributors to this document makes any warranty or representation (expressed or implied) with respect to the accuracy, completeness, or usefulness of the information contained in this document; or that the use of such information may not infringe privately owned rights; nor do they assume any responsibility for liability or damage of any kind which may result from the use of any of the information contained in this document.
Non-Proprietary Information GE-N E-OOOO-0053-8553-RONP Sheet 3 of 72 Abbreviations ACKNOWLEDGE (ACK)
Branch Junction Module (BIAU)
COMMAND (CMD)
Control Rod Drive (CRD)
Directional Control Valve (DCV)
Hydraulic Control Unit (HCU)
Low Power Set point (LPSP)
Main Control Room (MCR)
Multiplexer (MUX)
Odd Notch State Change (ONSC)
Odd Notch State Change Multiplier (ONSCM)
Out-of-Service (OOS)
Plant Process Computer (PPC)
Position Indicator Probe (PIP)
REQUEST (REQ)
Rod Block Monitor (RBM)
Rod Control Management System (RCMS)
Rod Position Information System (RPIS)
Validation and Factory Acceptance Testing (VFAT)
Non-Proprietary Information GE-NE-0000-0053-8553-RONP Sheet 4 of 72 Rod Control and Management System Failure Modes and Effects Analysis Conclusion Based on the FMEA performed, the potential failure modes for the RCMS have no adverse effect on the system to prevent an uncontrolled withdrawal of a Control Rod due to system operation or failures.
Non-Proprietary Information
& 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units I GE-NE-OOOO-0053-8553-RONP Sheet 5 of 72 NOINAME AND I FAILURE I CAS INERNT FETUO MSFNTO E
O FUNCTION MODEHOD OF DETCTION COMPENSATIN FETGPO I
RCFUTIN FAILURE IREMARKS AND FUCTON MOEPROVISION SYSTEM PREFORMED BY IMODE OTHER EFFECTS
[i 4
4
.4
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 6 of 72
'I 1
1 t
I l
A
J. _______________________
A.
.1
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 7 of 72 I-
+
4 4
1 l.
I l
l A
-A.-_______________________________________
.1.
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 8 of 72 L
4.
-r
+
+
.L
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 9 of 72
,_I.
I IIiI 4
4 4
4
_II
_ ____ __ I __.
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 10 of 72 I.
I A
A I
I
.1 4
I I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet II of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 12 of 72 I,
+
+
L I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 13 of 72 i.
I I I
Non-Proprietary Information I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units GE-N E-OOOO-0053-8553-RONP Sheet 14 of 72
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 15 of 72 i
I l
l l
4 l l
l
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 16 of 72 1
--r-1 T
I 1
1
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 17 of 72
Non-Proprietary Inrormation LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 18 of 72 t
I I
I t
t 1*
I I
-t I
I I
I I
+
I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 19 of 72 U
U U
U
.1.
.5-U
Non-Proprietnry Information
& 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units I GE-NE-0000-0053-8553-RONP Sheet 20 of 72 I
I l
l
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8S53-RONP Sheet 21 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 22 of 72 P _________________ I P ______________________________________
.4.
L 4 _____________________________________ 4 P
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 23 of 72 I
I I
,I I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 24 of 72
.4.
.4
Non-Proprietary Information LaSaile Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 25 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 26 of 72 I
I-I i
i I._
I__
I L _
I I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 27 of 72 I
I I l
.1 L
i L
Non-Proprietary Inrormation LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-OOOO-0053-8553-RONP Sheet 28 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 29 of 72
-4
+
4
+
4 4
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 30 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-85.3-RONP Sheet 31 of 72 I
I I
I V
l~
l I
lllll
.I I.
4 I
I I
I I
I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 32 of 72 I
T I1 I
4 4
I.
~
.4.4 4
44 1I
____________________.1.
+/-
L ___________________________________.J ___________________________ I __________________. __________________________________
___________ - ______________________
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFEcTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 33 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 34 of 72 I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 35 of 72 I
I L
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 36 of 72 I
I I
I l
l 4
4 4
I I
l l
l
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-OOOO-0053-8553-RONP Sheet 37 of 72 I+
I I
.... A...
Non-Proprietary Inrormation LaSalle Units I & 2 RCMS FAILURE MODES AND EFFEcTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 38 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 39 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 40 of 72
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 41 of 72 r
r l+
I l
l l
llI
Non-Proprietary Information
& 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units 1 GE-NE-0000-0053-8553-RONP Sheet 42 of 72 i
T
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTs ANALYSIS GE-NE-OOOO-0053-8553-RONP Sheet 43 of 72 I'
L 1
.1.
Non-Proprietary Information I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units GE-N E-0000-0053-8553-RONP Sheet 44 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 45 of 72 I
I.
I _.
I I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 46 of 72 I
I I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 47 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 48 of 72 V
r I
T T
Non-Proprietary Information I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units GE-NE-0000-0053-8553-RONP Sheet 49 of 72 I
S A
.5
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFEcTsANALYSIS GE-NE-0000-0053-8553-RONP Sheet 50 of 72 I.
I.
A __________________________________ 4- ____________ 1
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-OOOO-0053-8553-RONP Sheet 51 or 72 I
I I
I~_______J_______J J
_________Ji.
I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 52 of 72
-I.
4 4
4 I.
I.
4 4
Non-Proprietary Information I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units GE-NE-0000-0053-8553-RONP Sheet 53 of 72
-1 I _
I I_
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 54 of 72
1 1-
+
4 4
4
+
4 l
l l
I l I-
...........1. I.............
I I_.
I
Non-Proprietary Information 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS LaSalle Units GE-NE-0000-0053-8553-RONP Sheet 55 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 56 of 72
.I
.4
.1.
.4 4-4-
4
+
+
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 57 of 72
-4 4
4 4
- 4.
.1.
- 4.
.4.
4
- 4.
A.
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 58 of 72
-r 7
¶
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 59 of 72 Il I
I
-4 4
4 4-4 I
- I-1" I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 60 of 72 l
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 61 of 72 Il I I X
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 62 of 72
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 63 of 72 I0 X In I
I I Il
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 64 of 72
+
+
+
4 4
4 4
4-
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 65 of 72 I
I N
I I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-N E-0000-0053-8553-RONP Sheet 66 of 72 IL I
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 67 of 72 X
i
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFEcTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 68 of 72 I
I
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 69 of 72
,,, I I
Non-Proprietary Inrormation LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFECTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 70 of 72
Non-Proprietary Information LaSalle Units I & 2 RCMS FAILURE MODES AND EFFEcTs ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 71 of 72 I_
Non-Proprietary Information LaSalle Units 1 & 2 RCMS FAILURE MODES AND EFFEcTS ANALYSIS GE-NE-0000-0053-8553-RONP Sheet 72 of 72 I
I' 1
1 4
4
+
))
General Electric Affidavit and LaSalle County Station, Units 1 and 2 Rod Control Management System Failure Modes and Effects Analysis GE-NE-0000-0044-6934-RONP (Non-Proprietary)
General Electric Company AFFIDAVIT 1, Louis M. Quintana, state as follows:
(1) I am Manager, Licensing, General Electric Company ("GE"), have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld and have been authorized to apply for its withholding.
(2) The information sought to be withheld is contained in Enclosure 1 to GE letter GE-HA0-RCMS-034, W. Farrell (GE) to J. Kutches (Exelon), LaSalle RCMS Failure Modes and Effects Analysis (FMEA), dated May 4, 2006. The proprietary information in Enclosure 1, Lasalle Units 1 And 2, Rod Control Management System, Failure Modes And Effects Analysis, GE-NE-0000-0044-6934-ROP, is identified by a double underline inside double square brackets. In each case, the superscript notations refers to Paragraph (3) of this affidavit, which provides the basis for the proprietary determination.
(3) In making this application for withholding of proprietary information of which it is the owner, GE relies upon the exemption from disclosure set forth in the Freedom of Information Act ("FOIA"), 5 USC Sec. 552(b)(4), and the Trade Secrets Act, 18 USC Sec. 1905, and NRC regulations 10 CFR 9.17(a)(4), and 2.390(a)(4) for "trade secrets" (Exemption 4). The material for which exemption from disclosure is here sought also qualify under the narrower definition of "trade secret", within the meanings assigned to those terms for purposes of FOIA Exemption 4 in, respectively, Critical Mass Energy Project v. Nuclear Regulatory Commission. 975F2d871 (DC Cir. 1992), and Public Citizen Health Research Group v. FDA, 704F2dl280 (DC Cir. 1983).
(4) Some examples of categories of information which fit into the definition of proprietary information are:
- a. Information that discloses a process, method, or apparatus, including supporting data and analyses, where prevention of its use by General Electric's competitors without license from General Electric constitutes a competitive economic advantage over other companies;
- b. Information which, if used by a competitor, would reduce his expenditure of resources or improve his competitive position in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product;
- c. Information which reveals aspects of past, present, or future General Electric customer-funded development plans and programs, resulting in potential products to General Electric; Affidavit Page I
- d. Information which discloses patentable subject matter for which it may be desirable to obtain patent protection.
The information sought to be withheld is considered to be proprietary for the reasons set forth in paragraphs (4)a. and (4)b. above.
(5) To address 10 CFR 2.390 (b) (4), the information sought to be withheld is being submitted to NRC in confidence. The information is of a sort customarily held in confidence by GE, and is in fact so held. The information sought to be withheld has, to the best of my knowledge and belief, consistently been held in confidence by GE, no public disclosure has been made, and it is not available in public sources. All disclosures to third parties including any required transmittals to NRC, have been made, or must be made, pursuant to regulatory provisions or proprietary agreements which provide for maintenance of the information in confidence. Its initial designation as proprietary information, and the subsequent steps taken to prevent its unauthorized disclosure, are as set forth in paragraphs (6) and (7) following.
(6) Initial approval of proprietary treatment of a document is made by the manager of the originating component, the person most likely to be acquainted with the value and sensitivity of the information in relation to industry knowledge. Access to such documents within GE is limited on a "need to know" basis.
(7) The procedure for approval of external release of such a document typically requires review by the staff manager, project manager, principal scientist or other equivalent authority, by the manager of the cognizant marketing function (or his delegate), and by the Legal Operation, for technical content, competitive effect, and determination of the accuracy of the proprietary designation. Disclosures outside GE are limited to regulatory bodies, customers, and potential customers, and their agents, suppliers, and licensees, and others with a legitimate need for the information, and then only in accordance with appropriate regulatory provisions or proprietary agreements.
- 8)
The information identified in paragraph (2), above, is classified as proprietary because it contains detailed information regarding the GE Rod Control Management System (RCMS) design and Failure Modes And Effects Analysis (FMEA) results, which GE has developed.
The development of the RCMS and FMEA was achieved at a significant cost to GE, on the order of several hundreds of thousands of dollars.
The development of the RMCS and FMEA evaluation process along with the interpretation and application of the results is derived from the extensive experience database that constitutes a major GE asset.
Affidavit Page 2
(9) Public disclosure of the information sought to be withheld is likely to cause substantial harm to GE's competitive position and foreclose or reduce the availability of profit-making opportunities. The information is part of GE's comprehensive BWR safety and technology base, and its commercial value extends beyond the original development cost. The value of the technology base goes beyond the extensive physical database and analytical methodology and includes development of the expertise to determine and apply the appropriate evaluation process. In addition, the technology base includes the value derived from providing analyses done with NRC-approved methods.
The research, development, engineering, analytical and NRC review costs comprise a substantial investment of time and money by GE.
The precise value of the expertise to devise an evaluation process and apply the correct analytical methodology is difficult to quantify, but it clearly is substantial.
GE's competitive advantage will be lost if its competitors are able to use the results of the GE experience to normalize or verify their own process or if they are able to claim an equivalent understanding by demonstrating that they can arrive at the same or similar conclusions.
The value of this information to GE would be lost if the information were disclosed to the public. Making such information available to competitors without their having been required to undertake a similar expenditure of resources would unfairly provide competitors with a windfall, and deprive GE of the opportunity to exercise its competitive advantage to seek an adequate return on its large investment in developing these very valuable analytical tools.
I declare under penalty of perjury that the foregoing affidavit and the matters stated therein are true and correct to the best of my knowledge, information, and belief.
Executed on this 4th day of May 2006.
Louis M. Quintana Manager, Licensing Affidavit Page 3