E-mail from G. Bowman of USNRC to S. Smith of USNRC, Regarding Results Reanalysis of Trap Rock, Algonquin, Gypsum
ML061320437
Person / Time
Site: Indian Point  
Issue date: 03/15/2006
From: Gregory Bowman
Entergy Nuclear Operations
To: Shawn Smith
NRC/FSME
References
FOIA/PA-2006-0140
Download: ML061320437 (8)


Text

[-§-taci

'n ium resu Reana ys o rap oc,

on ypsum

- 1. -... I -

I I -

11 I I 11.1.1 1. -11 11 - I 1. I 9 " - - -1; -- -- - --" , ;- '-- -- X - -- II -- -111111-I   ---, --Oa66-11 Stac Smth FW:Triiumresuts eanlyss ofTra Rok, Agonuin Gypum aci 1 From:

"Bowman, Greg " <GBowm9O~entergy.com>

To:

"'sms4@nrc.gov"' <sms4@nrc.gov>

Date:

3/15/06 8:28AM

Subject:

FW: Tritium results Reanalysis of Trap Rock, Algonquin, Gypsum From: Lavera, Ron Sent: Friday, February 03, 2006 12:21 PM To: Bowman, Greg

Subject:

FW: Tritium results Reanalysis of Trap Rock, Algonquin, Gypsum RLaVera @ entergy.com <mailto: RLaVera © entergy.com>

914-736-8433 914-736-8419 FAX Indian Point 3 Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 3 P.O. Box 308 Buchanan, NY 10511-0308 From: Gorman, Barrie Sent: Friday, February 03, 2006 11:54 AM To: Burns, Thomas; Lavera, Ron; Mayer, Don; Sachatello, Ronald Cc: Axelson, William L; Baker, Dave; Pittenger, William; Boucher, Crystal; Colville, Richard; Mayer, Don

Subject:

Tritium results Reanalysis of Trap Rock, Algonquin, Gypsum Attached are the subject sample reanalysis. All 3 sample results were less that LLD.

These sample results represent a new aliquot of each sample from the original container that was distilled and counted in a new sample vial.

The original results for these samples, which were reported as positive activity (>LLD), are considered to be the result of contamination on the tritium analyzer sample holder rack. Additional testing and evaluation is in progress to confirm the contamination and documentation will be provided for your review. The racks have been removed from service and immediate short term corrective actions were set in place to prevent future contamination issues.

The contamination of these samples will be documented in a JAF Condition Report (CR) that I will forward to you as soon as the CR is entered.

Sample status: Currently in the tritium counter are the three original vials followed by the 4 samples received on 02/02/06. These samples will be done counting on Saturday night and the results will be processed and forwarded to you on Monday AM (02/06/06).

I will be at VY next week attending Entergy training. I will be in contact with the lab on a regular basis and will provide you with a channel of communication once I set up at VY.

Barrie

<<IPEC tritium reanalysis.PDF>>

>>a

Stacy Smith - FW: tritium results Reanalysis of Trap Rock, Algonquin, Gypsum Page 2

l optepGW000.M Page 1 ]

I c:\\t-emp\\GW }O0001 --.TMP PaIge 1

-I -~ ---11-.-

- 11 1

.1 -

1.111-

--,--1-II I I ~-I I

Mail Envelope Properties (4418167A.025: 24: 57381)

Subject:

Creation Date:

From:

Created By:

FW: Tritium results Reanalysis of Trap Rock, Algonquin, Gypsum 3/15/06 8:26AM "Bowman, Greg " <GBowm9O@entergy.com>

GBowm90@entergy.com Recipients nrc.gov kpl-po.KPDO SMS4 (Stacy Smith)

Post Office kpl-po.KPDO Route nrc.gov Files MESSAGE TEXT.htm IPEC tritium reanalysis.PDF Mime.822 Options Expiration Date:

Priority:

Reply Requested:

Return Notification:

Concealed

Subject:

Security:

Size 2225 4890 230404 325074 Date & Time 03/15/06 08:26AM None Standard No None No Standard

TRITIUM PROGRAM Tritium Analysis Sample Run ID Sheet Run No.

06-11 Plant Eff.

O Environmental As Other M

Background (CPM) 9.58 Background (DPM) 27.17 Sample Count Date 2/1/2006 Background Count Time(min.)

Background Counting Eff.

100 0.353 25 QC STD 3/14/2002 12:00 NA E3050 100 34.94 71.80 0.353 10062 f 265l 22-2 ALGONQUIN OUTFALL 1/24/2006 12:00 200602756 IP-06-044 100 10.68 1.36 0.374

<469 22-3 GYPSUM PLANT STREAM 1/24/2006 12:00 20060276B IP-06-045 100 10.39 1.88 0.358

<469 22-4 TRAP ROCK QUARRY 1/24/2006 12:00 20060277B IP-06-046 100 11.07 2.65 0.371 c469

=

=

=

1-z;M e z Pag / f /Comletd B:

Dte:2-3 C~

Page

/

If/

Completed By:

Date:

^

°

I. ---, -- -""I -   -

1 - x --.

Z-  " - -

I C -  -- 11 I - 1.

I  -

- --  1-- 1

[ Stacy Smith - IPEC tritium reanalysis.PDF IPace 21

,  V-i

",,,,,, -  % --- , -

-H --

- -x JAF ENVIRONMENTAL LABORATORY Tritium Activity Calculation Sample ID QC STD ELMS #:

NA Sample On Date/ Time:

03/14102 a

12:00 Client ID No.

E3050 SampleOHDate/Time:

03M14102 12:00 RunNo.

06.11 Sample Count Date:

02101106 a

12:00 Sample Distilled:

NO Elapsed Time (count date to off de) yrs 3.S9 Decay Factor:

0.8036 Background Gross counts:

958.22 Background count time (minutes) 100 Background Counts, CPM:

9.58 Background DPM 27.17 Critical Level (CL) CPM 0.72 Sample Gross counts:

3493.6667 Sample Count Time (minutes) 100 Sample CPM:

34.94 Sample Net CPM:

25.35 Sample DPM:

71.80 sample volume (L) 0.004 Background Counting EffIclency 0.353 CL Ratio= 35.21 LLD value (Ci/IL)

<583 Act/Error Ratio= 38.0 ample Counting Efficiency 0.353 Sample Activi ECVl/. t 1 slgma 106 2

265 Comments:

E.

X7.

3 /o /7Le Note: Kf CL ratio Is <1.0 OR Act/Error Ratio Is <:..7 than the LLD value Is reported as a 'Less Than' Activity.

Technician:

7 Date: Z Supervisor review: B. Gorman

/Date pdnt /slgn p:mtnuum programuntiurn activity calc.at

Stacy Smith - IPEC tritium reanalysis.PDFPage 3

JAF ENVIRONMENTAL LABORATORY Tritium Activity Calculation Sample ID ALGONQUIN OUTFALL ELMS #:

200602758 Sample On Date/Time:

01/24106 a

12:00 Client ID No.

IP-06-044 SampleOff DateITime:

01124106 a

12:00 RunNo.

06-11 Samle Count Date:

02101/06 e

12:00 mple Distilled:

YES Ela Time (__nt data SO Off daa) 002 DcFaor:

a0jj8 Background Gross counts:

958.22 Background count time (minutes) 100 Background Counts, CPM:

9.58 Background DPM 27.17 Crical Level (CL) CPM 0.72 Sample Gross counts:

1067.6667 Sample Count Time (minutes) 100 Sample CPM:

10.68 Sample Net CPM:

1.09 Sample DPM:

1.36 sample volume (L) 0.004 Background Counting Efficiency 0.Q53 CL Raio= 1.52 LLD value (pCi/L)

>AcUtError Ratio= 1.1 a

Sample Counting Efficiency 0.374 Sample Activity (pCi/L) 1 sIgma 153 e

136 Comments:

Note: If CL ratio Is <1.0 OR ActfError Ratio Is <.7 than the LLD value Is reported as a 'Less Than" Activity.

Technician:

Date:

Z -37 P /sign Supervisor review: S.Gorman ~@Date:

/°Xg print /sign p:\\tritum program\\trtium activity calcaxt

Stacy Smith - IPEC tritium reanalysis.PDF a

4 JAF ENVIRONMENTAL LABORATORY Tritium Activity Calculation Sample lD GYPSUM PLANT STREAM ELMSt:

20060276B Sample On DatelTime:

01/24/06 c

12:00 Client ID No.

IP-06-045 SampleOffDate/Time:

01/24/06 C

12:00 Run No.

06-11 Sample Count Date:

02/01106 a

12:00 Sample Disilled:

l 1YES rElapsed Time (count da o oft dae vn 0.02 Decay Factor.

Q.9988 Background Gross counts:

958.22 Background count time (minutes) 100 Background Counts, CPM:

9.58 Background DPM 27.17 Crftical Level (CL) CPM 0.72 Sample Gross counts:

1038.6667 Sample Count Time (minutes) 100 Sample CPM:

i0.39 Sample Net CPM:

0.80 Sample DPM:

1.88 sample volume (L) 0.004 Background Counting Efficiency 0.353 CL Ratlo= 1.12 LLD value (pCVL)

Act/Error Ratio= 1.5 Sample Counting Efficiency 0.358 Sample Activity (pCVfL) +/- I sigma 212

+/-

141 Comments:

Note: If CL ratio Is <1.0 OR Act/Error Ratio Is <2.7 than the LLD value is reported ass 'Lass Than Activity.

Technician:

54 k

Date:Z-5-6 Supervisor review: B. Gorma n

ignDate:

4 pdnt I3ign p\\tritium program~ritium activity calc.xit

Stacy Smith - IPEC tritium reanalvsis.PDF

', "U L. -

"' - -

 1-11111--

x

 W

-I--,' I -

I-----

-'1-----

I Paae 5 I L41-JAF ENVIRONMENTAL LABORATORY Tritium Activity Calculation Sample ID TRAP ROCK QUARRY ELMS #:

20060277B Sample On Date/ Time:

01J24106 e

12:00 Client ID No.

IP-06.046 SampleOtfDate/Time:

01124106 0

12:00 Run No.

06411 Sample Count Date:

02101/06 12:00 Sample Distilled:

ljYES ElaTpsed ime (count dats to off dsat) yrs 0.02 Decay Factor.

0.9988 Background Gross counts:

958.22 Background count time (minutes) 100 Background Counts, CPM:

9.68 Background DPM 27.17 Critical Level (CL) CPM 0.72 Sample Gross counts:

1107.3333 Sample Count Time (minutes) 100 Sample CPM:

11.07 Sample Net CPM:

1.49 Sample DPU:

2.65 sample volume L 0.004 Background Counting Efficiency 0.353 CL Ratlo= 2.07 LLD value (pCiVL)

_l Act/Error Ratio= 2.2 Sample Counting Efficlency 0.371 Sample Activity (pCllL) +/- 1 sigma 299 1 138 Comments:

Note: In CL ratio Is <1.0 OR Act/Error Ratio Is d.7 than the LLD value Is reported as a 'Less Then" Actity.

Technician:

P a

jE Date:Zt.3 z

/sign SupervIsor review: B. Gorm an'C. /

d a( '

Date:

print /sign p:\\tritium program\\tritium activity calcaxdt