ML061320220

From kanterella
Jump to navigation Jump to search
E-mail from R. Snyder of the State of New York to T. Rice of the State of New York, Regarding IPEC Sample Results Summary - Corrected
ML061320220
Person / Time
Site: Indian Point  
(DPR-005, DPR-026, DPR-064)
Issue date: 02/16/2006
From: Snyder R
State of NY, Dept of Health
To: Rice T
NRC/FSME, State of NY, Dept of Environmental Conservation
References
FOIA/PA-2006-0140
Download: ML061320220 (2)


Text

[Jameoge-F:IE apeRslsSm ay-crrected Paqe 1 1]

I From:

To:

Date:

Subject:

"Robert P. Snyder" <rpsO2 @health.state.ny.us>

<tbrice@ gw.dec.state.ny.us>

2/16/06 10:27AM Fw: IPEC Sample Results Summary - corrected Tim, here's the corrected spreadsheet, Should have been an ND in Gamma Spec Column for the 10/21 MW-i 1 1, not NA.

(See attached file: IPEC H3 Invest Sample Sumnmary.xls)

Thanks, Robert 0

Sampling Date Sample ID Sample Location Tritium pCi/l Sr-90 pCi/l Gamma Spec 10/21/05 200520855628 U2 CST

<110 NA NA 10/21/05 200520855629 U3-T2 1420+/- 160 NA NA 10/21/05 200520855630 U3-2 510 +/- 130 NA NA 10/21/05 200520855631 MW-i 11 267000 +i-8000 3 +/- 2 ND 10/21/05 200520855632 U3-4 340 +/- 120 NA NA 10/21/05 200520855633 U3-1

<110 NA NA 10/21/05 200520855634 U3-3

<110 NA NA 10/21/05 200520855535 U3-T1

<110 NA NA 11/30/05 200520855645 Trap Rock Quarry 90 +/- 60

<0.4 ND 11/30/05 200520855646 Algonquin Creek

<60 0.7 +/- 0.4 RDP 11/30/05 200520855647 5th Street Well

<60 0.8 +/- 0.7 RDP 11/30/05 200520855648 Gypsum Plant Ouffall

<60 0.8 +/- 0.4 RDP 12/06/05 200520855658 LaFarge Gypsum Well #1

<50 NA NA 12/06/05 200520855659 LaFarge Gypsum Well #3

<50 NA NA 12/08/05 200520855654 MW38 700 +/- 120 NA NA 12/08/05 200520855655 MW 101

<50 NA NA 12/08/05 200520855656 MW 105 100 +/- 90 NA NA 12/08/05 200520855657 MW 107

<50 NA NA NA - Not Applicable (This analysis was not performed)

ND - Non Detect ( No readings at or above detection limits)

RDP - Dissolved Radon Decay Products