O R I S E OAK RIDGE INSTITUTE FOR SCIENCE AN0 EDUCATION

, \\ p i 1 27, 2006 hlr. William Snell US. Nuclear Regulatory Commission Ikgion I11 2443 Warrenville Road lisle, IL 60532-4351

SUBJECT:

ANALYTICAL RESULTS FOR 41 WATER SAMPLES IN BATCH TWO FROM THE VICINITY OF THE BYRON GENERATING STATION, BYRON, ILLINOIS [INSPECTION REPORT NO. 05000454/2006-0031 (RFTA NO.06-001)

Dear Mr. Snell:

'Ihc Oak kdge Institute for Science and Education (ORISE) received 41 water samples in Batch Two on April 12,2006 that were collected in the vicinity of the Byron Generating Station in Byron, Illinois. This water sample sct was received at the same time as two water sample sets from the Braidwood facility.

'The laboratory has been instructed that samples from the Braidwood facility have higher priority a i d the samplrs from the Byron facility were analyzed after the Braidwood sample sets. The samples were analyzed for tritium using a liquid scintillation analyzer (Procedures A1'2, Revision 15 and CP4, Revision 3). The chain of custody identified six water samples to be analyzed by g;lmma spectroscopy (GS)

(l'rocedure CPl, Revision 15). The sample identifications and collection data are presented in Table 1.

'l'hc GS data arc presented in Table 2. The tritium data arc presented in Table 3.

ORISE's Quality Control (QC) requirements were met for these analyses. 'Ihe QC files are available for your review upon request.

My contact information is listcd below. You may also contact Wade hey at 865.576.9184 with any questions or comments.

Sincerely.

Ilale Condra, Manager 1,aboratory KDC:\\Y"I:ar T. McLaughlin, NRCINMSSI'IWFN 7F27 E. Ihox-Davin, NRC/NhISS/TWFN 81123 G. Bonano, NRC Region 111 E. rlbelquist, ORISE S. Kirk, ORlSE File 1689 C:

Distribution approval and concurrence :

Technicd Lfanagcment Team Member Quahty Manager iw 1 Initials I -SI<,

Voice: 865.241.3242 Fax: 865.241.3248 E-mail: CondraD@orau.gov RECEIVED MAY 0 2 2 0 6

TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA BYRON GENERATING STATION BYRON, ILLINOIS

TABLE 1 (cont.)

ORISE Sample ID SAMPLE IDENTIFICATIONS AND COLLECTION DATA BYRON GENERATING STATION BYRON, ILLINOIS NRC Region 111 Sample ID Collection Date I/

1689W0048 j BY-06-2-27 Collection Time 1689W0049 I BY-06-2-28 11 1689W0050 I BY-06-2-29 BY-06-2-33 1689W0055 BY-06-2-34 BY-06-2-38 1689W0060 BY-06-2-39 1689W0061 I BY-06-2-40 1689W0062 I BY-06-2-41

'N<i data nmvidcd 3/24/2006 I na 3/23/2006 3/23/2006 3/29/2006 3/29/2006 3/27/2006 3/29/2006 na 3/29/2006 3/28/2006 3/29/2006 3/29/2006 3/29/2006 3/29/2006 na

TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN SELECTED WATER SAMPLES BY GAMMA SPECTROSCOPY CPl, REVISION 15 BYRON GENERATING STATION BYRON, ILLINOIS ORISE Sample ID

  • 1 ( k rmgc i i f hllX:s for tlic sclcctcd radionuclides is 3.3 pCi/l. to 8.1 pCi/L.

"Unccrtamtics rcprcrcnt the 95'%, confidcncu Icrcl, bared on total propagated unccrtaintics.

TABLE 3 1689W0032 1689W0033 1689W0034 BY-06-2-11

-170 i-110 (200)

BY-06 12

-90 f

110 (200)

BY 2-1 3

-160 f

110 (200) 11 1689W0037 I BY-06-2-16 I

-200 f

110 (200) 11 1689W0040 1689WOO41 1689W0042 1689W0043 1689W0044 1689W0045 1689W0046 1689W0047 BY-06-2-19

-40 f

220 (400)

BY-06-2-20

-110 ir 220 (400)

BY-06-2-21

-20 f

230 (400)

BY-06-2-22

-30 i

230 (400)

BY-06-2-23

-150 f

220 (400)

BY-06-2-24

-170 f

220 (400)

BY-06-2-25 170 i-240 (400)

BY-06-2-26

-10 f

230 (400) 11 1689W0050 I BY-06-2-29 I

-170 ir 220 (400) 11 1 1689W0053 I BY-06-2-32 I

-220 f

240 (440) 1

TABLE 3 (cont.)

CONCENTRATIONS OF TRITIUM IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 BYRON GENERATING STATION BYRON, ILLINOIS