ML061070516

From kanterella
Jump to navigation Jump to search
E-mail from Kenneth Ainger to Nirodh Shah Groundwater Sample Results
ML061070516
Person / Time
Site: Braidwood  Constellation icon.png
Issue date: 01/30/2006
From: Singer K
Exelon Corp
To: Steven Orth, Nirodh Shah
Division of Reactor Safety III
References
FOIA/PA-2006-0115
Download: ML061070516 (7)


Text

SeeOth-Groundwater Sample R~esults

-7

-Pag I;

From:

<kenneth.ainger~exeloncorp.com>

To:

<nxs~nrc.gov>, <sko~nrc.gov>

Date:

Mon, Jan 30, 2006 11:49 AM

Subject:

Groundwater Sample Results Nick, Steve, Attached is an updated tabulation of sample results that I mentioned I would send you when we were at the residents meeting last Thursday.

Ken

<<AESULTS

SUMMARY

.xls>>

This e-mail and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.

This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You.

[ Steven Orth -RESULTS-

SUMMARY

.xIs Paae 1 I1 ample Collection pCV/I pCV/I pCIIL signatlon Date pCV/I.

(>200 but

(>2,000 but

(>20,000)

_2 2 0 0 0 )

-2 0,0 0 0 )

F -1 01-11-o6 33 +/-110 0

0 0

2

-1 01-11-06 33.+/-110 0

0 0

3

-OlD 01-11-06 60+/-111 0

0 0

4

-OlD 01-11-06 1

60 +/-111 0

0 0

5 L-01 11-17-05 70+/-96;96 0

0 0

6 L-02 11-17-05 156+/-99;101 0

0 0

7 L-03 11-18-05 0+/-94;94 0

0 0

8 L-04 11-18-05 40+/-95;96 0

0 0

9 L-05 11-18-05 102+/-98;99 0

0 0

10 L-06 11-18-05 114+/-112;113 0

0 0

1 1 L-7 11-18-05 39+/-109: 1 10 0

0 0

12 L-811-18-05 90+/-11 1; 112 0

0 0

13 B-9 12-23-05 4701 +/- 205 0

4701 0

1 4 L-901-11-06 5270+/-*206 0

5270 0

1 5 L-9 01-11-06 5270 +/-206 0

5270 0

1 6 L-9 01-18-06 5049 +/-204 0

5049 0

1 7 L-9 01-25-06 4809+/-k199 0

4809 0

18 L-9D 12-23-05 23097 +/- 415 0

0 23097 1 9 L-09D 01-11-06 22016 +/-399 0

0 22016 20 L-09D 01-11-06 22016 +/-399 0

0 22016 21 L-09D 01-18-06 21230 +/-394 0

0 21230 22 L0D 01-25-06 20383 +/- 383 0

0 20383 23 L10 11-17-05 295+/-118;124 295 0

0 24 L10 01-04-06

-104 +/-93 0

0 0

25 L10D 12-15-05 8259 +/-267 0

8259 0

26 L10D 01-04-06 7535+/-252 0

7535 0

27 L-1 1 11-17-05 61+/-96;97 0

0 0

28 L1 1 01-03-06 13 +/-108 0

0 0

29 BL11D 12-15-05

-213+/-93 0

0 0

30 L-11D 01-03-06

-27+/-*107 0

0 0

31

-12 11-17-05 126+/-87;89 0

0 0

32 L12 01-03-06

-39 +/-95 0

0 0

33 L12D 12-15-05

-31 +/-108 0

0 0

34 L12D 01-03-06

-35 +/-95 0

0 0

35 L12D 01-03-06 65 +/-99 0

0 0

36 L13 11-17-05 76+/-96;97 0

0 0

37 L13 01-03-06

-16 +/-107 0

0 0

38 L13D 12-15-05

-150 +/-104 0

0 0

39 L-1 3D 01-03-06 9 +/-108 0

0 0

40 L-14 11-17-05 70+/-96;96 0

0 0

41 L-14 01-13-00

-37+/-95 0

0 0

42 L-14D 12-15-05

-187 +/-94 0

0 0

43 L-14D 01-03-06

-91 +/-93 0

0 0

44 L15 11-17-05 1,178+/-128;205 1178 0

0 45 L15 01-03-06 146 +/-87 0

0 0

46 L15D 12-16-05

-38 +/-106 0

0 0

47 L15D 01-03-06

-49+/-90 0

0 0

48 L16 11-17-05 4,058+/-201:587 0

1 4058 0

49 L16 01-03-06 3364 +/-185 0

3364 0

so L16D 12-16-05

-85 +/-104 0

0 0

51 L16D 01-03-06

-91 +/-93 0

0 0

52 L17 12-01-05 25+/-96:96 0

0 0

53 L17 12-05-05 105+/-112:1 13 0

0 0

54 L-1 7 12-05-05 183+/-114;1I17 0

0 0

55 L-17 01-03-06

-44 +/-106 0

0 0

56

___1___

__)_

12-12-05 28+/-94:94 0

0 0

57 L1D01-03-06

-126 +/-104 0

0 0

12-01-05 108+/-99,100 0

0 0

59_

19 _

12-01-05 37+/-97:97 0

0 0

60 D

12-23-05

-76 +/-91 0

0 0

61 D01-04-06

-117+/-92 0

0 0

62 112-12-05 85+/-96:97 0

0 0

63 101-03-06

-80 +/-105 0

0 0

64_

112-12-05 158+/-104:106 0

0 0

65_

101-03-06

-1 40+/-*103 0

0 0

6601-24-06

-48 +/-110 0

0 0

67 D01-24-06 147 +/-117 0

0 0

68_

112-06-05 92+/-11 1:112 0

0 0

69_

_01-04-06

-13 +/-96 0

0 0

70 1)12-23-05

-147+/- 106 0

0 0

71

__1)_

01-04-06

-141+/-91 0

0 0

72_

12-05-05 125+/-1 13:1 14 0

0 0

73_

12-05-05 59+/-110:110 0

0 0

74_

01-04-06

-165 +/-*90 0

0 0

75

___)_

12-23-05

-91 +/- 108 0

0 0

76_

D_ _

01-04-06

-36 +/-*95 0

0 0

77_

12-02-05" 137+/-1 00: 102 0

0 0

78_

01-04-06

-168 +/-90 0

0 0

79 D

12-23-05 4674 +/-215 0

4674 0

F Steven Orth-RESULTS

SUMMARY

.xIs Page 2 1 80 03D 01-04.06 51 10 +/-214

.0 5110 0

81 3D 01-04-06 5317+/-*21 8 0

5317 0

8204 12-06-05 91*111;112 0

0 0

83 05 12-02-05 73+/-98;98 0

0 0

84

-1 12-12-05 104*97;98 0

0 0

85

-1 01-03-06

-44+/-*1 11 0

0 0

86

-OD 12-12-05 1

139+/-113;1 14 0

0 0

87

-OlD 01-03-06

-56 1 10 0

0 0

88

-0D 01-09.06 684*1 19 684 0

0 89

-0D

.01-12-06 546 +/-133 546 0

0 90

-0D 01-09-06 1689+/-1 46 1689 0

0 9 1

-0D 01-12-06 1689+/-*144 1689 0

0 92

-0D 01-24-06

-22+/-k1 11 0

0 0

93

-0D 01-24-06 1512+/-k130 1512 0

0 94

-0D 01-24-06 689+/-*133 689 0

0 95

-0D 01-24-06 575+/-*130 575 0

0 96

-0D 01-24-06 872+/-*1 11 872 0

0 97 112-06-05 133+/-112,114 0

0 0

98 -212-06-05 87+/-111;111 0

0 0

9 0D01-26-06 67 +/-114 0

0 0

1012-06-05 81+/-111:111 0

0 0

1112-06-05 126+/-1 12;l113 0

0 0

10 1111-15-05 157+/-96:98 0

0 0

10 n02/a nk/a nla 0

10 1311-15-05 2,497+/-1l73;381 0

2497 0

10 1 4n/a rn/a n/a 0

10 1511-15-05 729*119;155 729 0

0 10 1501-04-06 169+/- 112 0

0 0

10 0D12-16-05 469+/-105 0

0 0

19 -0D01-04-06

-120+/-102 0

0 0

11 1601-04-06

-35+/-105 0

0 0

il 0D12-16-05

-115+/-87 0

0 0

11 10D01-04-06

-25+/-*10D6 0

0 0

11 1711-15-05 269+/-1 12;1I18 269 0

0 11 1811-15-05 91+/-90:91 0

0 0

15 10 nla n/a nk/a 0

11 1011-15-05 93+/-t90;91 0

0 0

11 1001-04-06

-1 04+/-*93 0

0 0

11 1111-15-05 224+/-1 12; 116 224 0

0 11 1101-04-06

-78+/-k104 0

0 0

12

-1D01-09-06

-66+/-104 0

0 0

12 11 01-09-06

-118+/-102 0

0 0

12 1211-15-05 167*1 10;1 12 0

0 0

13 W11 01-04-06

-127 +/-92 0

0 0

124 W-1 12D 01-09-06

-111+/-103 0

0 0

125 W-113 11-15-05 4.830+/-219;692 0

4830 0

126 W-113 12-05-05 4,009+/-207;155 0

4009 0

127

-113 12-05-05 3,598+/-188;524 0

3598 0

128 W-113 01-03-06 4008 +/-202 0

4008 0

129 W-1 13D 12-14-05 4835 +/-211 0

4835 0

130 W-1 13D 01-03-06 4772+/-*21 5 0

4772 0

131

-1 12-01-05 2,484+/-174;380 0

2484 0

132

-212-02-05 4,344+/-288;657 0

4344 0

133

-201-03-06 2045+/-*163 0

2045 0

134

-0D 12-12-05 2,599+/-177;395

~

0 2599 0

135

-0D 01-03-06 2384+/-k170 0

2384 0

136

-312-02-05 3,258+/-258;51 3 0

3258 0

137

-412-01-05 33,041+/-509;4,522 0

0 33041 138

-412-01-05 33,763+/-499;4,619 0

1 0

33763 139

-412-06-05 25,311+/-435;3,470 0

0 25311 140-0401-03-06 19317+/-*390 0

19317 0

141-0401-11-06 15937+/-342 0

15937 0

142

-04 01-18-06 12165+/-*302 0

12165 0

143-0401-25-06 9588+/-290 0

9588 0

144-0401-11-06 15937+/-*342 0

15937 0

145

-0D 12-23-05 59592 +/- 657 0

1 0

59592 146

-0D 01-03-06 48493 +/-604 0

0 48493 147

-0D 01-11-06 47095+/- 578 0

0 47095 148

-0D 01-11-06 47095 +/-578 0

0 47095 149

-04D 01-18-06 50308+/-599 0

0 50308 150

-0D 01-25-06 38965+/- 523 0

0 38965 151 05 12-01-05 6,621+/-248:934 0

6621 0

152 0501-03-06 61668+/-245 0

6166 0

153

-0D 12-23-05 2402+/-161 0

2402 0

154

-0D 01-03-06 2165+/-*166 0

2165 0

.155

-612-01-05 450+/-123:138 450 0

0 156-0601-18-06 110 +/-84 0

0 0

157

-712-01-05 1,210+/-133;212 1210 0

0 158

-812-01-05 2,998+/-185:448 0

2998 0

159

-812-06-05 2,212+/-160:341 0

2212 0

j160

-912-05-05 1,346+/-148:235 1346 0

0 1161 P-09 12-06-05 1

-90+/-t96:97 0

0 0

ISteven Orth - RESULTS

SUMMARY

.xls Page 3 1 162 0912-13-05 111+/-112;113 0

0 0

13-912-13-05 27+/- 104 0

0 0

164

-10 12-05-5 1,934*162;309 1934 0

0 165

-10 12-06-05 1,723+/-149;278 1723 0

0 166

-11 12-05-05 1,681*156;277 1681 0

-0 167 1 1 12-06-05 1,476+/-143;246 1476 0

0 168

-12 12-05-05 1,535+/-1 53;259 1535 0

0 169

-12 12-06-05 1,622+/-1 54;269 1622 0

-0 170

-13D 12-23-05 226468 +/-1270 0

0 2266 171

-13D 12-28-05 225231 +/- 1268 0

0 225231 172

-13D 01-11-06 229838+/-t1296 0

0 229838 173

-13D 01-11-06 229838+/- 1296 0

0 2298386 174

-13D 01-18-06 223754+/- 1254 0

0 223754 175

-13D 01-25-06 217122+/-*1223 0

0 217122 176

-13D 01-25-06 221625+/-*874 0

0 221625 177

-13D 01-03-06 228283+/-1295 0

0 228283 178

-14 01-24-06 2537+/-*154 0

2537 0

179

-14D 01-24-06 2388+/-*151 0

2388 0

180 S-0l 12-22-05

-18+/-*95 0

0 0

181 8-01 01-04-06

-89 +/-93 0

0 0

182 8-02 12-22-05

-89+/-*93 0

0 0

183 S-02 01-04-06 15-*97 0

0 0

184 8-301-04-06

-137+/- 91 0

0 0

185 S-04 0 1-10D-06 30+/-86 0

0 0

186 S-06 01-12-06 287+/- 104 287 0

0 187 W-01 11-30-05

-26+/-112; 112 0

0 0

188 W-02 11-30-05 48*97;97 0

0

-0 189

-03 11-30-05 25+/-96;96 0

0 0

190

-04 12-02-05 43*97;97 0

0 0

191

-05 12-07-05 9*1 00; 100 0

0 0

192

-05 01-19-06

-12+/-87 0

0 0

193

-06 0

0 0

194

-06P 12-08-05 142+/-114;1 15 0

0 0

195

-07 12-07-05

-58+/-98;98 0

0 0

196

-08 12-03-05 1,151+/-130;2D4 1151 0

0 197

-08 12-06-05 1,524+/-151 ;257 1524 0

0 198 P-08 12-08-05 1,367+/-1 35;229 1367 0

0 199 W-09 12-05-05 142+/-113;115 0

0 0

200

-10 12-07-05 72+/-110;111 0

0 0

201 W-11 12-05-05 99+/-112;107 0

0 0

202 W-12 12-07-05 44+/-1 09; 1 10 0

0 0

203 W-13 12-07-05

-62+/-97;98 0

0 0

204 W-14 12-14-05

-1 18+/-105 0

0 0

20 w-is 12414-05

-51 +/-108 0

0 0

206 WN-101 01-24-06 161 +/-87 0

0 0

207 WN-101 01-24-06 161 +/-87 0

0 0

208 N-103 01-24-06 134+/-*86 0

0 0

209 N-103 01-24-06 134+/-*87 0

0 0

210 N-104 01-13-06

-75+/-*76 0

0 0

211 N-104 01-13-06

-75+/-*76 0

0 0

212 N-105 01-13-06

-40+/-k78 0

0 0

213 N-105 01-13-06

-40+/-*78 0

0 0

214 N-ill 01-24-06 30+/-*113 0

0 0

215 N-Ill 01-24-06 30+/-*113 0

0 0

216 N-112 01-24-06

-37+/-111 0

0 0

217 N-112 01-24-06

-37+/-111 0

0 0

218 N-115 01-24-06 11 +/-112 0

0 0

219 N-1 S 01-24-06 11 +/-112 0

0 0

220 8-101 01-24-06

-28+/-t1 11 0

0 0

221 S-101 01-24-06

-28 +/-111 0

0 0

222 S-102 01-24-06

-99 +/-109 0

0 0

223 S-102 01-24-06

-99+/-109 0

0 0

224 S-105 01-24-06 194+/-88 0

0 0

225 WS-105 01-24-06 194+/-*88 0

0 0

226 WS-105 01-24-06 191 +/- 88 0

0 0

227 s-los 01-24-06 191 +/-88 0

0 0

228 S-106 01-10-06 44+/-86 0

0 0

229 S-109 01-24-06 124+/-k85 0

0 0

230 S-109 01-24-06 124 +/-88 0

0 0

231 S-110 01-24-06 154+/-*87 0

0 0

232 S-11O 01-24-06 154 +/-87 0

0 0

233 S-201 01-18-06

-21 +/-78 0

0 0

234 S-201 01-18-06

-21 +/- 78 0

0 0

235 W-01 12-01-05 2,396*173;369 0

2396 0

236

-01 12-01-05 2,050+/-153;318 0

2050 0

237

-01 12-04-05 7.855+/-254;1098 0

7855 0

238 W-02 12-01-05 33,736+/-499;4,615 0

0 33736 239 W-02 12-01-05 30,605*475;4,189 0

0 30605 240 W-02 12-04-05 88,778*798;12,100 0

0 88778 241 W-02010' 12-13-05 54,111+/-832;7,386 0

0 54111 24 -02@10.6' 12-06-05 58,621+/-644;7,998 0

0 58621 1243 IW-02@20-12-13-05 171,166+/-1,115;23,305 0

0 171166

I Steven Orth - RESULTS

SUMMARY

.xls Page 4 q 244 W-02@20.6' 12-06-05 170,024*1,089;23,1 49 0

0 170024 24 -02025' 12.13-05 246,442+/-1l,337;33,543 0

0 246442 246 R-02@25.0' 12-06-05 223,888+/-1,299;30,476 0

Q 223888 247 W-03 12-02-05 197*107;111 0

0 0

248 W-04 12-02-05 380*113;125 380 0

0 249

-1 12-05-05

-21+/-107;107 0

0 0

25 01 12-06-05 83+/-111;111 0

0 0

251

-OD 01-26-06 1287+/- 149 1287 0

0 252

-212-05-05 95*111;112 0

0 0

253

-212-06-05 88+/-103;104 0

0 0

254

-201-03-08 62+/-110 0

0 0

255

-201-03-06

-1 8 107 0

0 0

256

-02D 12-12-05 225*101;105 225 1

0 0

257

-0D 01-03-06

-2+/- 108 0

0 0

258 0312-05-05 145+/-113;l115 0

0 0

259

-312-06-05 57*102;102 0

0 0

260 12-05-05 1,280+/-147;228 1280 0

0 261

-412-06-05 1,086+/-133;199 1086 0

0 262

-0D 01-26-06 21 11+/-*168 0

2111 0

263

-512-05-05 2,023*1 65;321 0

2023 0

264

-5 12-06-05 1,874+/-1 52;297 1874 0

0 265 -06 12-05-05 679+/-130;160 679 0

0 266 -612-06-05 411*113;126 411 0

0 267 -7 01-24-06 1373 +/- 151 1373 0

0 268 0D 01-24-06 1546+/-*155 1546 0

0 269 11-01 01-13-06 34+/-*81 0

0 0

270 ii-2 01-13-06

-4+/-*92 0

0 0

271 il-03 01-12-06 6+/- 97 0

0 0

272 W-01 11-30-05 2464+/-163;373 0

2464 0

273 W-02 1

1-30-05 2347+/-160;357 0

2347 0

274 W-02 01-11-06 2938+/-*162 0

2938 0

275 W-02 01-11-06 2812+/-*112 0

2812 0

276 W-02 01-11-06 2938+/-t162 0

2938 0

277 W-02 01-11-06 2812+/-*112 0

2812 0

278 W-02 01-18-06 2504+/-*154 0

2504 0

279 W-02 01-25-06 2441+/-*175 0

2441 0

280 W-03 12-02-05 96+/-99;100 0

0 0

281 W-04 12-02-05 83*98;99 0

0 0

282

-OlD 01-11-06

-368+/-108 0

0 0

283 T-01lD 01-11-06

-36 *108 0

0 0

284 TB-02D 01-11-06 36+/-*110 0

0 0

285 TB-02D 01-11-06 36+/-*110 0

0 0

286 TB-03D 01-11-06

-265+/-*11 7 265 0

0 287 iB-03D 01-11-06 265+/-*117 265 0

0 288 TB-04D 01-11-06 622+/-*128 622 0

0 289 IB-04D 01-11-06 622 *128 622 0

0 290 T-OSD 01-11-06

-7+/- 109 0

0 0

291 T-05D 01-11-06

-7+/-*

109 0

0 0

292 T06D 01-11-06

-49+/- 107 0

0 0

293 T-06D 01-11-06

-49+/-*107 0

0 0

294 TB-07D 01-11-06

-49+/-t107 0

0 0

295 T-07D 01-11-06

-49+/-t107 0

0 0

296 VB01-02D 01-13-06 238+/-*89 238 0

0 297 B1-03D 01-13-06 19431 +/-378 0

19431 0

298 B1-04D 01-13-06 7424+/-242 0

7424 0

299 B01-05D 01-13-06 22928+/-410 0

0 22928 300 B01-06D 01-13-06 41 +/-81 0

0 0

301 1O-09D 01-13-06 3370+/-173 0

3370 0

302 01-1 11-15-05 1,194+/-140;215 1194 0

0 303 B1-1 01-04-06 425+/- 112 425 0

0 30 O-D12-16-05

-49+/-*90 0

0 0

35 B11 01-04-06

-132+/-92 0

0 0

36 B12 11-17-05 337*97;107 337 0

0 37 BI311-15-05 206*110;114 206 0

0 38 1411-15-05 384+/-102;114 384 0

0 39 1511-15-05 130+/-92;94 0

0 0

30 1511-22-05 57+/-114;114 0

0 0

31 1 11-22-05 95+/-1 15 1 16 0

0 0

32 1711-22-05 140+/-100;102 0

0 0

31 0-D01-09-06

-1 16+/-92 0

0 0

31n18

/a n/a n/a 0

31 0-D01-09-06 10,877+/-295 0

10877 0

31 0 911-22-05 107+/-99;100 0

0 0

31 0-901-12-06 78+/-*96 0

0 0

31 D01-12-06

-65+/-*91 0

0 0

39 B2111-15-05 207+/-98:102 207 0

0 32 211-15-05 6,193+/-228;873 0

6193 0

31 2212-05-05 5,832+/-236;827 0

5832 0

32 212-05-05 1

5,569+/-222:789 0

556.%9 0

323 B02-2 01-04-06 5232+/-222 0

5232 0

324 B02'2D 12-23-05 3445+/- 194 0

3445 0

1325 IB02-2D 01-04-06 4 037+/- 202 0

4037 0

E RESULTS

SUMMARY

.xis Page 5 1 326 B02-3 11-15-05 3,940+/-1 95;570 0

3940 0

32 B02-4 11-15-05 3,664*190;533 0

3664 0

328 B02-5 1 1-15-05 4,270j2-02;615 0

4270 0

329 B02-5 01-03-06 3834 +/-194 0

3834 0

330 B02-5D 12-14-05 64+/- 1 11 0

0 0

331 B02-5D 01-03-06 102 *101 0

0 0

332 80-6 11-15.05 2,132+/-157;330 0

2132 0

333 80-6 12-05-05 2,348+/-171;362 0

2348 0

334 80246 12-05-05 1,979+/-162;314 1979 0

0 335 B02-6 01-03-06 1412+/-*128 1412 0

0 336 B02-6D 12-14-05 56+/-111 0

0 0

33 B02-6D 01-03-06 44+/-83 0

0 0

338 8027 12-14-05

-47 108 0

0 0

339 827 01-04-06

-60 105 0

0 0

340 82-7D 12-14-05

-52+/-96 0

0 0

341 80-7 01-04-06

-53+/-t105 0

0 0

342 02812-14-05

-103+/-*94 0

0 0

343 B03-01 11-15-05 5,959+/-225;841 0

5959 0

344 B03-02 11-15-05 26,686+/-453;3,658 0

0 26686 345 803-02 11-15-05 32,830+/-509;4,494 0

0 32830 346 80-311-16-05 43,894+/-580;5,998 0

0 43894 347 803-04 11-16-05 58,489+/-702;7,985 0

0 58489 348 B03-04 12-05-05 43,708t.592;5,974 0

0 43708 349 B03-04 12-05-05 40,654+/-54;5,544 0

0 40654 350 B03-04 01-03-06 29286+/-t475 0

0 29286 351 80-4 12-14-05 747 +/- 132 747 0

0 352 80 D4 01-03-06 790+/-k123 790 0

0 353 80-5 11-22-05 95*98;99 0

0 0

354 0-611-22-05 53,572+/-637;7,31 4 0

0 53572 355 80-712-02-05 169+/-106;109 0

0 0

356 80-701-03-06

-126+/-92 0

0 0

357 B30D12-14-05

-79+/-95 0

0 0

358 B03-07D 01-03-06

-205+/-*89 0

0 0

359 B03-08 12-02-05 171+/-106;109 0

0 0

360 803-09D 12-13-05 21,715+/-408:2,981 0

0 21715 361 803-09D 01-04-06 19,605 +/-393 0

19605 0

36 0-012-16-05 8473+/-*260 0

8473 0

36 001-03-06 12076 +/-316 0

12076 0

364 8310D 12-16-05 70773 +/-710 0

0 70773 35 B31D01-03-06 108736+/-871 0

0 108736 36 0-301-25-06 24846+/-*444 0

0 24846 367 80-3 01-25-06 7+/-112 0

0 0

3801-25-06

-39+/-k1 11 0

0 0

369 80-4 01-25-06 17 +/-113 0

0 0

30 4112-19-05

-1 19+/-*94 0

0 0

31B4101-03-06 942+/-136 942 0

0 101-03-06 895 +/-135 895 0

0 33 B41D12-22-05

-34 +/-95 0

0 0

34 B41D01-04-06

-688+/-94 0

0 0

35 B4201-10-06 24+/-86 0

0 0

37 0-D01-10-06 26+/-86 0

0 0

37_B5-_1_2_0

_-6 40 0

0 38 B5101-03-06

-38+/-107 0

0 0

39 B51D12-22-05 0+/-96 0

0 0

38 0-D01-04-06

-126+/-92 0

0 0

31B6112-20-05

-160+/- 107 0

0 0

32 101-03-06 29+/-*109 0

0 0

33 B61D12-20-05

-151 +/- 108 0

0 0

34 B61D01-04-06

-85 +/-93 0

0 0

38 0-201-12-06

-123 *112 0

0 0

38 0-201-12-06

-1 25+/-t11 2 0

0 0

37 B7112-20-05 1612 +/-140 1612 0

0 38 112-22-05 2358+/-*173 0

2358 0

39 101-03-06 2776+/-179 0

2776 0

39 D12-22-05 169+/-118 0

0 0

391 I0-1 01-04-06 179+/-10D3 0

0 0

32 B7312-23-05

-9+/-*1 11 0

0 0

33 B7412-23-05

-65+/-k109 0

0 0

34 B7 01-10-06

-14+/-84 0

0 0

35 B7601-10-06 75+/-88 0

0 0

39 112-20-05

-1 03+/-*86 0

0 0

37 B8101-04-06

-1 05+/-*93 0

0 0

38 B81D12-20-05 487+/-*87 0

0 0

39 D01-04-06

-131 +/-92 0

0 0

40 9112-22-05

-9+/- 113 0

0 0

41 9101-04-06

-7+/-*96 0

0 0

42 B91D12-22-05 60 +/-111 0

0 0

43 B-112-22-05

-116+/-*109 0

0 0

404 810-10 12-22-05 40 +/-114 0

00 405 810-10 01-04-06

-157+/-91 0

00 406 B10-10 01-04-06 461 +/-94 0

00 407 811-01 01-04-06 7+/-97 0

00

I Steven Orth -FRESULTS

SUMMARY

.xis

. Page 6 408 BI1 -01 n/a We n/a 0

409 VB11-1D 12-23-05 21 +/-95 0

0 0

410 Bl-ID 01-04-06

-150+/-91 0

0 0

411 CFPD-01 01-10-06 26*86 0

0 0

412 CFPD-01D 01-12-06

-114t113 0

0 0

413 CFPD-02 01-10-06 58+/-87 0

0 0

414 CFPD-02D 01-12-06

-121 t112 0

0 0

415

-Braidwood Cooling Lake 2B Bay 12-14-05

-61 +/- 95 0

0 0

416

-Condensate (Unit 1) 12-22-05 45004 +/- 573 0

0 45004 417

-Condensate (Unit 2) 12-22-05 39233 t 537 0

0 39233 418

-Ditch O Culvert 12-22-05 1007 +/- 128 1007 0

0 419

-Holding Pond Fresh Water 12-14-05

-100

  • 106 0

0 0

420

-Kankakee River 0 Bar Racks 12-14-05

-162 +/- 92 0

0 0

421

-Kankakee River between RSH & CWBD 12-14-05

-187

  • 91 0

0 0

422

-Kankakee River Upstream 200' 12-14-05

-150 +/- 92 0

0 0

423

-North Oil Separator 12-13-05 107*112;113 0

0 0

424

-North Oil Separator 12-13-05 57 t105 0

0 0

425

-Potable Water 12-13-05 6,024*239;853 0

6024 0

426

-Potable Water 12-13-05

-77 +/- 113 0

0 0

427

-Potabe Water 12-13-05

-50+/- 113 0

0 0

428

-Potable Water 12-13-05

-125 +/-101 0

0 0

429

-Potable Water (NTB) 12-14-05

-132 +/- 93 0

0 0

430

-Potable Water (NTB) 12-16-05

-94 +/- 104 0

0 0

431

-Potable Water (SB) 12-14-05

-88 +/-94 0

0 0

432

-Turbine Building Ground Water 12-13-05 2,825+/-181;425 0

2825 0

433

-Turbine Building Ground Water 12-13-05 2609 +/- 182 0

2609 0

434

-Turbine Building Ground Water 12-16-05 2584 +/- 163 0

2584 0

435 x-TW Pneumatic Tank 12-14-05

-98

  • 106 0

0 0