I Steven Orth - Fwd: G oundwater Sample Results Pagel1 From:
Steven Orth To:
John Cassidy Date:
Thu, Feb 2, 2006 12:53 PM
Subject:
Fwd: Groundwater Sample Results FYI.
CC:
John House
I Steven Opt --Groundwater Samnple Results Sten rPage 1,
From:
<kenneth.ainger exeloncorp.com>
To:
<nxs~nrc.gov>, <skoXnrc.gov>
Date:
Mon, Jan 30, 2006 11:49 AM
Subject:
Groundwater Sample Results Nick, S:eve, Attached is an updated tabulation of sample results that I mentioned I would send you when we were at the residents meeting last Thursday.
Ken
<<RESULTS
SUMMARY
.xis>>
- ~**~*a***************************************************************
This e-maif and any of its attachments may contain Exelon Corporation proprietary information, which is privileged, confidential, or subject to copyright belonging to the Exelon Corporation family of Companies.
This e-mail is intended solely for the use of the individual or entity to which it is addressed. If you are not the intended recipient of this e-mail, you are hereby notified that any dissemination, distribution, copying, or action taken in relation to the contents of and attachments to this e-mail is strictly prohibited and may be unlawful. If you have received this e-mail in error, please notify the sender immediately and permanently delete the original and any copy of this e-mail and any printout. Thank You.
Steven Orth - RESULTS
SUMMARY
.xis Paqe 1
~ample Collection pCl/L pCI/L pCVIL Deinto aepCIIL
(>200 but
(>2,000 but
(>20,000)
De i n to ae22000) 20,000) 1 A-01 01-11-06 33+/-110 0
0 0
2 A-01 01-11-06 33 +/-110 0
0 0
3 A-010 01-11-06 60 +/-111 0-0 0
4
-01D 01-11-06 60 +/-111 0
0 0
5 BL-01 11-17-05 70+/-96;96 0
0 0
6 BL-02 11.17-05 156+/-99;101 0
0 0
7 BL-03 11-18-05 0+/-94;94 0
0 0
8 BL-04 11-18-05 40+/-95;96 0
0 0
9 BL-05 11-18-05 102+/-98;99 0
0 0
1 0
L-6 11-18-05 114+/-112;113 0
0 0
1 1 L-07 11-18-05 39+/-109;110 0
0 0
1 2 L-08 11-18-05 90+/-1 11;1 12 0
0 0
1 3
L-09 12-23-05 4701 +/- 205 0
4701 0
14 BL-09 01-11-06 5270 +/-206 0
5270 0
15 L-9 01-11-06 5270 +/-206 0
5270 0
16 L-9 01-18-06 5049 +/-204 0
5049 0
17 BL-09 01-25-06 4809 +/-199 0
4809 0
18 BL-09D 12-23-05 23097 +/- 415 0
0 23097 19 BL-09D 01-11-06 22016 +/-399 0
0 22016 20 BL-09D 01-11-06 22016 +/- 399 0
0 22016 21 BL-09D 01-18-06 21230 +/-394 0
0 21230 22 BL-09D 01-25-06 20383 +/-383 0
0 20383 23 BL-1 0 11-17-05 295+/-118;124 295 0
0 24 BL-1 0 01-04-06
-1 04+/-t93 0
0 0
25 BL-10D 12-15-05 8259 +/-267 0
8259 0
26 BL-10D 01-04-06 7535 +/-252 0 -
7535 0
27 BL-1 1 11-17-05 61+/-96;97 0
0 0
28 BL-1 1 01-03-06 13 +/-108 0
0 0
29 BL-11D 12-15-05
-213 +/-93 0
0 0
30 L-11D 01-03-06
-27 +/-107 0
0 0
31 L12 11-17-05 126+/-87;89 0
0 0
32 L-1 2 01-03-06
-39 +/-95 0
0 0
33 BL-12D 12-15-05
-31 +/-108 0
0 0
34 BL12D 01-03-06
-35 +/-95 0
0 0
35 BL12D 01-03-06 65 +/- 99 0
0 0
36 BL-13 11-17-05 76+/-96;97 0
0 0
37 BL-1 3 01-03-06
-16 +/-107 0
0 0
38 BL-13D 12-15-05
-150 +/-104 0
0 0
39 BL-13D 01-03-06 9 +/-108 0
0 0
40 BL14 11-17-05 70+/-96;96 0
0 0
41 BL-14 01-13-00
-37+/-95 0
0 0
42 BL-14D 12-15-05
-187+/-94 0
0 0
43 BL-14D 01-03-06
-91 +/-93 0
0 0
44 BL-I15 11-17-05 1,178+/-128;205 1178 0
0 45 BL-1 5 01-03-06 146 +/- 87 0
0 0
46 BL-15D 12-16-05
-38+/-106 0
0 0
47 BL15D 01-03-06
-49+/-90 0
0 0
48 BL-16 11-17-05 4.058+/-201;587 0
4058 0
49 BL-16 01-03-06 3364 +/-185 0
3364 0
50 BL-16D 12-16-05
-85+/-t104 0
0 0
51 BL-16D 01-03-06
-91 +/- 93 0
0 0
52 BL-17 12-01-05 25+/-96;96 0
0 0
53 BL-1 7 12-05-05 105+/-112:1 13 0
0 0
54 BL-1 7 12-05-05 183+/-114:1 17 0
0 0
55 BL-1 7 01-03-06
-44+/- 106 0
0 0
56 BL-1 7D 12-12-05 28+/-94;94 0
0 0
57 BL-17D 01-03-06
-126 +/-104 0
0 0
58 BL18 12-01-05 108+/-99:100 0
0 0
59 BL19 12-01-05 37+/-97;97 0
0 0
60 BL-20D 12-23-05
-76 +/- 91 0
0 0
61 BL-20D 01-04-06
-1 17+/-t92 0
0 0
62
-01 12-12-05 85+/-96:97 0
0 0
63
-01 01-03-06
-80 +/-105 0
0 0
64
-OD 12-12-05 158+/-104;106 0
0 0
65
-OD 01-03-06
-140 +/-103 0
0 0
66
-2 01-24-06
-48 +/-110 0
0 0
67
-02D 01-24-06 147 +/-117 0
0 0
68 0-1 12-06-05 92+/-1 1 1 112 0
0 0
69 0-0 01-04-06
-13+/-96 0
0 0
70 0-10 12-23-05
-1 47+/-t 106 0
0 0
71 0-OD 01-04-06
-141+/-91 0
0 0
72 0-02 12-05-05 125+/-113:1 14 0
0 0
73 0D-02 12-05-05 59+/-1 10;1 10 0
0 0
74 D-02 01-04-06
-165 +/-90 0
0 0
75 D-02D 12-23-05
-91 +/-108 0
0 0
76 D-02D 01-04-06
-36 +/- 95 0
0 0
77 D-03 12-02-05 137+/-100:102 0
0 0
78 0-03 01-04-06
-168 +/-90 0
0 0
79 0-03D 12-23-05 4674 +/-215 0
4674 0
I Steven h - RESUL'TS
SUMMARY
.xls Page 21 80
-03D 01-04-06 5110 +/-214 0
5110 0
81
-3D 01-04-06 5317+/-t218 0
5317 0
82
-4 12-06-05 91+/-111:112 0
0 0
83
-5 12-02-05 73+/-98;98 0
0 0
84
-1 12-12-05 104+/-97;98 0
0 0
85 F-1 01-03-06
-44 +/-111 0
0 0
86 1-OD 12-12-05 139+/-113;1 14 0
0 0
87 I-0 10 01-03-06
-56 +/-110 0
0 0
88
=-02D 01-09-06 684+/-119 684 0
0 89
- -02D 01-12-06 546 +/-133 546 0
0 90 z-03D 01-09-06 1689+/-146 1689 0
0 91 F-03D 01-12-06 1689+/-t.144 1689 0
0 92 --040 01-24-06
-22 +/-111 0
0 0
93
- -05D 01-24-06 1512+/-130 152 0
0
-94
-6D 01-24-06 689+/-133 689 0
0 95
-07 01-24-06 575 +/-130 575 0
0 96
-80 01-24-06 872 +/-111 872 0
0 97
-01 12-06-05 133+/-112;1 14 0
0 0
98
-02 12-06-05 87+/-1 1 10111 0
0 0
99
-020 01-26-06 67 +/-114 0
0 0
100
-3 12-06-05 81+/-111:111 0
0 0
.101
-3 12-06-05 126+/-112;1 13 0
0 0
102 W-101 11-15-05 157+/-96;98 0
0 0
103 W-102 nla n/a n/a 0
104 W-103 11-15-05 2,497+/-173;381 0
2497 0
105 W-104 n/a r/a n/a 0
106 W-105 11-15-05 729+/-119;155 729 0
0 107 MW-1 05 01-04-06 169 +/-112 0
0 0
108 MW-105D 12-16-05
-69+/-105 0
0 0
109 W-1O05D 01-04-06
-120 +/-102 0
0 0
110 W-106 01-04-06
-35 +/-105 0
.0 0
111 W-106D 12-16-05
-115 +/-87 0
0 0
112 W-106D 01-04-06
-25 +/- 106 0
0 0
113 W-107 11-15-05 269+/-112;1 18 269 0
0 114 W-108 11-15-05 91+/-90:91 0
0 0
115 W-109 n/a n/a n/a 0
116 W-110 11-15-05 93+/-90;91 0
0 0
117 W-110 01-04-06
-104+/-t93 0
0 0
118 W-111 11-15-05 224+/-112;116 224 0
0 119 W-111 01-04-06
-78 +/-104 0
0 0
120 W-111D 01-09-06
-66+/-104 0
0 0
121 W-111D 01-09-06
-118+/-102 0
0 0
122 W-112 11-15-05 167+/-110;112 0
0 1
0 123 W-112 01-04-06
-127 +/-92 0
0 0
124 W-112D 01-09-06
-111+/-103 0
0 0
125 W-113 11-15-05 4,830+/-219;692 0
4830 0
126 W-113 12-05-05 4,009+/-207;155 0
4009 0
127 W-113 12-05-05 3,598+/-188:524 0
3598 0
128 W-113 01-03-06 4008 +/-202 0
4008 0
129 W-1 13D 12-14-05 4835 +/-211 0
4835 0
130 W-1 13D 01-03-06 4772 +/-215 0
4772 0
131 P-a 12-01-05 2,484+/-174:380 0
2484 0
132 P02 12-02-05 4,344+/-288,657 0
4344 0
133 P-2 01-03-06 2045 +/- 163 0
2045 0
134 P-20 12-12-05 2,599+/-177:395 0
2599 0
135 P-02D 01-03-06 2384 +/- 170 0
2384 0
136 P-03 12-02-05 3,258+/-258:513 0
3258 0
137 P-04 12-01-05 33,041 +/-509:4,522 0
0 33041 138 P-04 12-01-05 33,763+/-499:4,619 0
0 33763 139 P-04 12-06-05 25.311+/-435:3,470 0
0 25311 140 P-04 01-03-06 19317 +/-390 0
19317 0
141 P-4 01-11-06 15937 +/-342 0
15937 0
142
-4 01-18-06 12165 +/-302 0
12165 0
143 P-4 01-25-06 9588 +/-290 0
9588 0
144 P-4 01-11-06 15937 +/-342 0
15937 0
145 P-4D 12-23-05 59592 +/- 657 0
0 59592 146 P-4D 01-03-06 48493 +/- 604 0
0 48493 147
-040 01-11-06 47095 +/-578 0
0 47095 148 P-040 01-11-06 47095 +/-578 0
0 47095 149
-040 01-18-06 50308 +/-599 0
0 50308 150 P04D 01-25-06 38965 +/-523 0
0 38965 151 P-o 12-01-05 6,621+/-248:93 0
6621 0
152
-05 01-03-06 6166 +/-245 0
6166 0
153
-05D 12-23-05 2402 +/-161 0
1 2402 0
154 P-5D 01-03-06 2165 +/-166 0
2165 0
iSS P-06 12-01-O5 450+/-123:138 450 0
0 156 P-06 01-18-06 110 +/-84 0
0 0
157 P-07 12-01-05 1,210+/-133:212 1210 0
0 158 P-08 12-01-05 2,998+/-185:448 0
29980 159 P-08 12-06-05 2,212+/-160:341 0
2212 0
160 P-09 12-05-05 1,346+/-148;235 1346 0
0 161 P-09 12-06-05
-90+/-96:97 0~"
0 0
I Steven Orth - RESULTS
SUMMARY
.xls Page 31 162 3-09 12-13-05 1 11+/-1l12;1 13 0
0 0
163' :-09 12-13-05 27+/-t104 0
0 0
164 :-1 0 12-05-05 1,934+/-162;309 1934 0
0 165 3-10 12-06-05 1,723+/-1 49;278 1723 0
0 166
-1 1 12-05-05 1,681+/-156;277 1681 0
0 167
-1 1 12-06-05 1,476+/-1 43;246 1476 0
0 168 P-12 12-05-05 1,535+/-1 53;259 1535 0
0 169
-12 12-06-05 1,622+/-154;269 1622 0
0 170
-13D 12-23-05 226468 +/-1270 0
0 226468 171 P13D 12-28-05 225231 +/- 1268 0
0 225231 172
-13D 01-11-06 229838 +/-1296 0
0 229838 173 P13D 01-11-06 229838 +/-1296 0
0 2298386 174 P13D 01-18-06 223754 +/-1254 0
0 223754 175
-13D 01-25-06 217122 +/-1223 0
0 217122 176
-13D 01-25-06 221625 +/-874 0
0 221625 177 P-13D 01-03-06 228283+/-1295 0
0 228283 178
-14 01-24-06 2537+/- 154 0
2537 0
179
-14D 01-24-06 2388 +/-151 0
2388 0
180 PS-01 12-22-05
-18 +/- 95 0
0 0
181 PS-01 01-04-06
-89 +/-93 0
0 0
182 PS-02 12-22-05
-89+/-t93 0
0 0
183 PS-02 01-04-06 15 +/-97 0
0 0
184 PS-03 01-04-06
-137 +/
0 0
.0 185 PS-04 01-10-06 30+/-86 0
0 0
186 PS-06 01-12-06 287 +/-104 287 0
0 187 PW-01 11-30-05
-26*1 12;1 12 0
0 0
188 P-02 11-30-05 48+/-97;97 0
0 0
189 P-03 11-30-05 25+/-96;96 0
0 0
190 W-04 12-02-05 43+/-97;97 0
0 0
191 P-05 12-07-05 9+/-100;100 0
0 0
192 W-05 01-19-06
-12 +/-87 0
0 0
193 W-06 0
0 0
194 P-06P 12-08-05 142+/-1 14;1 15 0
0 0
195 PW-07 12-07-05
-58+/-98;98 0
0 0
196 PW-08 12-03-05 1,151+/-130;204 1151 0
0 197 PW-08 12-06-05 1,524+/-151;257 1524 0
0 198 PW-08 12-08-05 1,367+/-1l35:229 1367 0
0 199 PW-09 12-05-05 142+/-113;1 15 0
0 0
200 IPW-1 0 12-07-05 72+/-11 0;1 11 0
0 0
201 PW-1 1 12-05-05 99+/-112;107 0
0 0
202 PW-12 12-07-05 44+/-109;110 0
0 0
203 PW-13 12-07-05
-62+/-97;98 0
0 0
204 PW-14 12-14-05
-118+/-105 0
0 0
205 PW-15 12-14-05
-51+/- 108 0
0 0
206 PWN-101 01-24-06 161+/- 87 0
0 0
207 PN-101 01-24-06 161 +/-87 0
0 0
208 WN-103 01-24-06 134 +/-86 0
0 0
209 WN-103 01-24-06 134+/-87 0
0 0
210 PN-104 01-13-06
-75+/-76 0
0 0
211 PN-104 01-13-06
-75+/-76 0
0 0
212 PN-105 01-13-06
-40+/-78 0
0 0
213 PN-105 01-13-06
-40+/-t78 0
0 0
214 PWN-1 11 01-24-06 30 +/-113 0
0 0
215 PWN-1 11 01-24-06 30+/-t 113 0
0 0
216 PWN-1 12 01-24-06
-37+/-111l 0
0 0
217 PWN-1 12 01-24-06
-37 +/- 111 0
0 0
218 PWN-1 15 01-24-06 11 +/-112 0
0 0
219 IPWN-1 15 01-24-06 11 +/-112 0
0 0
220 PWS-101 01-24-06
-28 +/-111 0
0 0
221 PWS-101 01-24-06
-28 +/-111 0
0 0
222 PWS-102 01-24-06
-99 +/- 109 0
0 0
223 PWS-102 01-24-06
-99 +/-109 0
0 0
224 PWS-105 01-24-06 194+/-d-88 0
0 0
225 PWS-105 01-24-06 194+/-t88 0
0 0
226 WS-105 01-24-06 191+/-88 0
0 0
227 WS-1 05 01-24-06 191+/- 88 0
0 0
228 WS-106 01-10-06 44+/-86 0
0 0
229 PS-109 01-24-06 124 +/-85 0
1 0
0 230 WS-109 01-24-06 124 +/-88 0
0 0
231 WS-110 01-24-06 154 +/-87 0
0 0
232 PS-110 01-24-06 154 +/-87 0
0 0
233 WS-201 01-18-06
-21 +/-t78 0
0 0~ -
234 P S-201 01-18-06
-21 +/- 78 0
0 0
235 R-01 12-01-05 2,396+/-173;369 0
2396 1
0 236 R-01 12-01-05 2,050+/-153;31 8 0
2050 0
237 R-01 12-04-05 7,855+/-254;1098 0
7855 0
238 RW-02 12-01-05 33,736+/-499;4,615 0
0 33736 239 R-02 12-01-05 30,605+/-475:4,189 0
0 30605 240 RW-02 12-04-05 88,778+/-t798;12,100 0
0 88778 241 RW-02@10 12-13-05 54,111+/-t632;7,386 0
0 54111 242 RW-02@10.6-12-06-05 58,621+/-t644;7,998 0
0 58621 243 RW-02@20' 1-30 171,166+/-1,115:23,305 0
0 171166
l Steven Orth - RESULTS
SUMMARY
.xls Page 4 244 W-02@~20.6' 12-06-05 170,024+/-1l,089;23,149 0
0 170024 24 -02@25' 12-13-05 246,442+/-1l,337;33,543 0
0 246442 2~46 W-02@25.0' 12-06-05 223,888+/-1l,299;30,476 0
0 223888 247 W-03 12-02-05 197+/-1l07;1 11 0
0 0
248 W-04 12-02-05 380+/-113;125 380 0
0 249
-01 12-05-05
-21+/-107;107 0
0 0
250
-1 12-06-05 83+/-1 11;1 11 0
0 0
251
-OlD 01-26-06 1287 +/-149 1287 0
0 252
-2 12-05-05 95+/-11I1;1 12 0
0 0
253
-2 12-06-05 88+/-103;104 0
0 0
254
-2 01-03-06 62 +/-110 0
0 0
255
-2 01-03-06
-18 +/-107 0
0 0
256
-02D 12-12-05 225+/-101;105 225 0
0 257
-02D 01-03-06
-2 +/-108 0
0 __
0 258
-03 12-05-05 145+/-113;115 0
0 __
0 259
-03 12-06-05 57+/-102;102 0
_0 0
260
-04 12-05-05 1,280+/-147;228 1280 0
0 261
-04 12-06-05 1,086+/-133;199 1086 0
0 262
-04D 01-26-06 2111 +/-168 0
2111 0
263
-5 12-05-05 2,023+/-165;321 0
2023 0
264
-5 12-06-05 1,874+/-152;297 1874 0
0 265
-06 12-05-05 679+/-130:160 679 0
0 266
-06 12-06-05 411+/-113;126 411 0
0 267
-7 01-24-06 1373+/-t151 1373 0
0 268
-07D 01-24-06 1546+/- 155 1546 1
0 0
269 i11-01 01-13-06 34 +/-81 0
0 0
270 oil-02 01-13-06
-4 +/-92 0
0 0
271 i11-03 01-12-06 6 +/-97 0
0 0
272 W-01 11-30-05 2464+/-163:373 0
2464 0
273 W-02 11-30-05 2347+/-160:357 0
2347 0
27 -201-11-06 2938 1 20 29380 275 W-02 01-11-06 2812 +/-112 0
2812 0
276 W-02 01-11-06 2938 +/-162 0
2938 0
277 W-02 01-11-06 2812 +/-112 0
2812 0
278 W-02 01-18-06 2504 +/-1,54 0
2504 0
279 W-02 01-25-06 2441 +/- 175 0
2441 0
280 W-03 12-02-05 96+/-99:100 0
0 0
281 W-04 12-02-05 83+/-98:99 0
0 0
282 B-OlD 01-11-06
-36+/-j:108 0
0 0
283 TB-Ol D 01-11-06
-36+/-t1 08 0
0 0
284 TB-02D 01-11-06 36 +/-110 0
0 0
285 TB-02D 01-11-06 36 +/-110 0
0 0
286 TB-03D 01-11-06 265 +/-117 265 0
0 287 TB-03D 01-11-06 265 +/-117 265 1
0 ___
0 288 TB-04D 01-11-06 622 +/-128 622
___0 0
289 TB-04D 01-11-06 622 +/-128 622 0 ___
0 290 TB-05D 01-11-06
-7 +/-109 0
___0 0
291 TB-05D 01-11-06
-7 +/-109 0
0 0
292 TB-06D 01-11-06
-49 +/-107 0
0 0
293 TB-06D 01-11-06
-49 +/-107 0
0 0
294 B-07D 01-11-06
-49 +/-107 0
0 0
295 8-07D 01-11-06
-49+/- 107 0
0 0
296 B01-02D 01-13-06 238+/-t89 238 0
0 297 B01-03D 01-13-06 19431 +/-378 0
19431 0
298 B01-04D 01-13-06 7424 +/-242 0
7424 0
299 B01-05D 01-13-06 22928 +/- 410 0
0 22928 300 B01-06D 01-13-06 41 +/-81 0
0 0
301 B01-09D 01-13-06 3370 +/-173 0
3370 0
302 B01-1 11-15-05 1,194+/-140:215 1194 0
0 303 B01-1 01-04-06 425 +/-112 425 0
.0 304 601-lD 12-16-05
-49 +/-90 0
0 0
305 B01-1D 01-04-06
-132+/-92 0
0 0
306 601-2 11-17-05 337+/-.97:107 337 0
0 307 B01-3 11-15-05 206+/-110:114 206 0
0 308 B01-4 11-15-05 384+/-102:1 14 384 0
0 309 B01-5 11-15-05 130+/-92:94 0
0 0
310 601-5 11-22-05 57.+/-114:1 14 0
0 0
311 BOI-6 11-22-05 95+/-115:1 16 0
0 0
312 B01-7 11-22-05 140+/-100:102 0
1 0
0 313 B01-7D 01-09-06
-116+/-92 0
0 0
314 801-8 n/a n/a n/a 0
315 B01-8D 01-09-06 10D,877+/-295 0
10877 0
316 B01-9 11-22-05 107+/-99:100 0
0 0
317 B02-09 01-12-06 78 +/-96 0
0 0
318 B02-09D 01-12-06
-65 +/-91 0
0 0
319 B02-1 11-15-05 207+/-98:102 207 0
0 320 602-2 11-15-05 6,193+/-228:873 0
6193 1
0 321 B02-2 12-05-05 5,832+/-236:827 0
5832 0
322 602-2 12-05-05 5.569+/-222:789 0
5569 0
323 602-2 01-04-06 5232 +/-222 0
5232 0
324 B02-2D 12-23-05 3445 +/-194 0
3445 0
325 B02-2D 01-04-06 4037 +/-202 0
4037 0
Steven Orth - RESULTS
SUMMARY
.xAs Page 5_!
326 B102-3 11-15-05 3,940+/-195;570 0
3940 0
32 B02-4 11-15-05 3,664+/-190;533 0
3664 0
328 B02-5 11-15-05 4,270+/-202:615 0
4270 0
329 B02-5 01-03-06 3834 +/- 194 0
3834 0
330 B02-5D 12-14-05 64 +/-111 0-0 0
331 B02-5D 01-03-06 102 +/-101 0
0 0
332 802-6 11-15-05 2,132+/-157;330 0
2132 0
333 8V02-6 12-05-05 2,348+/-171;362 0
2348 0
334 8V02-6 12-05-05 1,979+/-162:314 1979 0
0 335 B02-6 01-03-06 1412 +/-128 1412 0
0 336 B02-6D 12-14-05 56+/-111 0
0 0
337 B02-6D 01-03-06 44 +/-83 0
0 0
338 B02-7 12-14-05
-47 +/-108 0
0 0
339 B02-7 01-04-06
-60+/- 105 0
0 0
340 B02-7D 12-14-05
-52 +/- 96 0
0 0
341 B02-7D 01-04-06
-53 +/-105 0
0 0
342 IB02-8 12-14-05
-103 +/-94 0
0 0
343 6B03-01 11-15-05 5,959+/-225;841 0
5959 0
344 IB03-02 11-15-05 2 6,686+/-453:3,658 0
0 26686 345 I803-02 11-15-05 32,830+/-509;4,494 0
0 32830 346 I803-03 11-16-05 43,894+/-580:5,998 0
0 43894 347 8V03-04 11-16-05 58,489+/-702:7,985 0
0 58489 348 B03-04 12-05-05 43,708+/-592;5,974 0
0 43708 349 B03-04 12-05-05 40,654+/-.545;5,544 0
0 40654 350 B03-04 01-03-06 29286 +/-475 0
0 29286 351 B03-04D 12-14-05 747 +/- 132 747 0
0 352 B03-04D 01-03-06 790 +/-123 790 0
0 353 803-05 11-22-05 95+/-98:99 0
0 0
354 B03-06 11-22-05 53,572+/-637;7,314 0
0 53572 355 8B03-07 12-02-05 169+/-106:109 0
0 0
356 8B03-07 01-03-06
-1 26+/-92 0
0 0
357 8B03-07D 12-14-05
-79 +/-95 0
0 0
358 IB03-07D 01-03-06
-205+/-t89 0
0 0
359 8B03-08 12-02-05 171+/-106:109 0
0 0
360 /B03-09D 12-13-05 21,715+/-408:2,981 0
0 21715 361 B03-09D 01-04-06 19,605 +/-393 0
19605 0
362 B03-1 0 12-16-05 8473 +/-260 0
8473 0
363 803-1 0 01-03-06 12076 +/-316 0
12076 0
364 B03-10D 12-16-05 70773 +/-710 0
0 70773 365 B03-10D 01-03-06 108736 +/-871 0
0 108736 366 804-03 01-25-06 24846+/- 444 0
0 24846 367 804-03D 0-50 1
368 8V 04-04 01-25-06
-39 +/- 111 369 804-04D 01-25____06__17__+/-113 370 804-1 12-19-05
-119 +/-94 0
0 0
371 B04-1 01-03-06 942 +/- 136 942 0
0 372 804-1 01-03-06 895 +/-135 895 0
0 373 B04-10D 12-22-05
-34 +/- 95 0
0 0
374 B04-1iD 01-04-06
-68 +/-94 0
0 0
375 804-2 01 -1 0-06 24+/-86 0
0 0
376 B04-2D 01-10-06 26+/-86 0
0 0
377 B05-1 12-22-05
-66+/-t94 0
0 a
378 B05-1 01-03-06
-38t +/-107 0
0 0
37 B05-10D 12-22-05 0+/- 96 0
0 0
380 B05-1iD 01-04-06
-126+/-92 0
0 0
381 B06-1 12-20-05
-160 +/-107 0
0 0
382 B06-1 01-03-06 29 +/-109 0
0 0
383 806-10 12-20-05
-151 +/- 108 0
0 0
384 B06-10D 01-04-06
-85 +/-93 0
0 0
385 B07-02 01-12-06
-123 +/-112 0
0 0
386 B07-02 01-12-06
-125 +/-112 0
0 0
387 807-1 12-20-05 1612 +/-140 1612 0
0 388 B07-1 12-22-05 2358 +/-173 0
2358 0
389 B07-1 01-03-06 2776 +/-179 0
2776 0
390 B07-1 D 12-22-05 169 +/-118 0
0 0
391 B07-10 01-04-06 179 +/-103 0
0 0
392 B07-3 12-23-05
-9+/-111 0
0 0
393 B07-4 12-23-05
-65+/- 109 0
0 0
394 B07-5 01-10-06
-1 4+/-84 0
0 0
395 B07-6 01-10-06 75+/-88 0
0 0
396 808-1 12-20-05
-1 03 +/-86 0
0 0
397 B08-1 01-04-06
-105 +/-93 0
0 0
398 B08-1iD 12-20-05
-87 +/-87 0
0 0
399 B08-10 01-04-06
-131+/- 92 0
0 0
400 B09-1 12-22-05
-9+/-113 0
0 0
401 B09-1 01-04-06
-7+/-96 0
0 0
402 B09-1iD 12-22-05
-60 +/-111 0
0 0
403 B10-1 12-22-05
-1 16+/-t109 0
0 0
404 810-1D 12-22-05 40 +/-114 0
0 0
405 B10-1D 01-04-06
-157+/-91 0
0 0
406 810-1D 01-04-06
-61 +/-94 0
0 0
.407 811-01 01-04-06 7 +/-97 0
0 0
l Steven Orth - RESULTS
SUMMARY
.xIs Page 6 408 Bi1-01 n/a n/a n/a 0
409 B11-1D 12-23-05 21 +/- 95 0
0 0
410 B11-1D 01-04-06
-150+/- 91 0
0 0
411 CFPD-01 01-10-06 26+/-86 0
0 0
412 CFPD-01D 01-12-06
-114+/-113 0
0 0
413 CFPD-02 01-10-06 58+/-87 0
0 0
414 CFPD-02D 01-12-06
-121 +/-112 0
0 0
415
-Braidwood Cooling Lake 2B Bay 12-14-05
-61 +/- 95 0
0 0
416
-Condensate (Unit 1) 12-22-05 45004 +/- 573 0
0 45004 417
-Condensate (Unit 2) 12-22-05 39233 +/- 537 0
0 39233 418
-Ditch @ Culvert 12-22-05 1007+/- 128 1007 0
0 419 J-Holdng Poni Fresh Water 12-14-05
-100 +/- 106 0
0 0
420
-Kankakee R ver @ Bar Racks 12-14-05
-162 +/- 92 0
0 0
421
-Kankakee R ver between RSH & CWBD 12-14-05
-187 +/- 91 0
0 0
422
-Kankakee R ver Upstream 200' 12-14-05
-150 +/- 92 0
0 0
423
-North Oil Separator 12-13-05 107+/-112;113 0
0 0
424
-North Oil Separator 12-13-05 57 +/- 105 0
0 0
425
-Potable Wat r 12-13-05 6,024+/-239;853 0
6024 0
426
-Potable Wat.)r 12-13-05
-77 +/- 113 0
0 0
427
-Potable Wat,)r 12-13-05
-50 +/- 113 0
0 0
428
-Potable Wat,?r 12-13-05
-125 +/- 101 0
0 0
429
-Potable Watbr (NTB) 12-14-05
-132 +/- 93 0
0 0
430
-Potable Watbr (NTB) 12-16-05
-94 +/- 104 0
0 0
431
-Potable Wator (SB) 12-14-05
-88 +/- 94 0
0 0
432
-Turbine Building Ground Water 12-13-05 2,825+/-181;425 0
2825 0
433
-Turbine Building Ground Water 12-13-05 2609 +/- 182 0
2609 0
434 x-Turbine Building Ground Water 12-16-05 2584 +/- 163 0
2584 0
435 x-TW Pneuma:ic Tank 12-14-05
-98 +/-106 0
0 0.