News Release, Braidwood Station Tritium Project Progresses, Drinking Water Well Tests Show No Health or Safety Risk
ML061010775
Person / Time
Site: Braidwood  
(NPF-072, NPF-077)
Issue date: 12/29/2005
From: Miller N
Exelon Nuclear
To:
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0115, FOIA/PA-2010-0209
Download: ML061010775 (2)


Text

Exekln.

News Release Nuclear

Contact:

Neal Miller FOR IMMEDIATE RELEASE Exelon Nuclear - Braidwood Station (o) 815-417-3184, (c) 815-994-6522 Braidwood Station Tritium Project Progresses Drinking water well tests show no health or safety risk BRACEVILLE, III. (Dec. 29, 2005) - Environmental workers at the Braidwood Generating Station have made progress in understanding the extent of tritium in groundwater discovered by the plant's environmental monitoring program in November.

Among the more important findings: tests fr other radioactive substances in the environment have been negative, and 13 of 14 private wells have shown no sign of tritium beyond background levels. The fourteenth private well showed tritium at a fraction of federal drinking water limits and poses no health or safety risk.

Tritiumr is an isotope of hydrogen that emits a very low level of radiation. It is produced naturally in the upper atmosphere when cosmic rays strike air molecules and is also produced in nuclear reactor,. Tritium exists in water as an isotope of hydrogen - a basic component of water - and carries most of the characteristics of water.

The U.S. Environmental Protection Agency has established an upper limit for tritium concentration in drinking water of 20,000 picocuries per liter. By way of context, a person drinking 2 liters of water a day at that upper limit would receive an annual radiation exposure roughly equal to an airplane flight across the countly, about 4 millirem. The average American receives 300 millirem of background exposure annually from natural and manmade sources.

The tritium is believed to come from an underground pipe that passes near the location of the highest tritium concentration. The pipe in the past has carried water containing diluted tritiumr, from the plant to the Kankakee River, where it was periodically discharged under federal guidelines as part of normal plant operations. To ensure there are no current leaks, technicians are conducting a pipe integrity test. No tritiated water is currently in the pipe anid no tritium is currently being introduced into the ground.

In the froject to determine the extent of and mitigate tritium in groundwater at Braidwood:

  • Technicians have analyzed 211 groundwater samples taken from 158 test wells both on and off he plant property and from a 25-acre pond just north of the station.
  • The highest concentration of tritium discovered in both on-and off-site test wells was about 226,000 picocuries per liter, at the location where the tritium leak is believed to have occ'irred. This is in an area remote from private drinking water wells and does not represent a health or safety threat. To date, the next highest concentration found outside of the plant's

-more-

Braidwood Page 2 boundaries was about 59,000 picocuries per liter, from a test well 75 feet north of the prcperty line, the only other well off of the property to show tritium levels above federal dri:iking water limits. Water from the 25-acre pond measured 2,400 picocuries per liter.

  • The Illinois Environmental Protection Agency notified Braidwood and Exelon Nuclear on Dez. 20 that tritium concentrations reported from two offsite wells, the 25-acre pond and five on-site test wells were in violation of the Illinois Environmental Protection Act. The station is required to provide the agency results of its ongoing investigation and plans to resolve the violations by early February.
  • Thirteen of the 14 private drinking water wells near the plant showed no tritium above normal background levels. The remaining well showed a low level of tritium about 7 percent (1,324 picocuries per liter) of the federal drinking water limit.
  • Tests of water samples from the private, monitoring and test wells showed no radionuclides present in the groundwater other than tritium. This was a standard isotopic test that looks for a range of possible station-produced and naturally occurring radioactive substances.
  • Test wells have been drilled along the pipe at the locations of 11 "vacuum breakers" (three on the plant property, eight off), which are devices believed to have caused some past releases of tritiated water. Results from seven of the offsite locations showed no tritium corcentrations beyond background. The remaining offsite location, in a remote area on company property 2'/2 miles from the plant, showed a low level of tritium near the pipe (about 2,000 picocuries per liter), indicating a release there in the past. Additional wells are beiag dug for confirmatory tests.
  • More than 20 full-time technical experts, environmental consultants and others have been assigned to complete the groundwater studies and oversee mitigation of the tritium.

"While the news is generally good and there is no health or safety threat, our goal and obligation is to eliminate this tritium in groundwater and to make sure no tritium is ever again allowed to go where it is not supposed to go," said Exelon Nuclear Vice President Keith Polson, the station's senior ' xecutive. "We will continue to work full speed to this end, we will keep everyone informed as we progress and we will take whatever steps necessary in the meantime to ensure the full confidence of our immediate neighbors."

A tritium fact sheet is available at http://www.epa.gov/radiation/radionuclides/tritium.htm Braidwood Generating Station is about 60 miles southwest of Chicago near Braceville, Ill. The station's two nuclear energy units can produce a total of more than 2,300 megawatts at full power, enough electricity for more than 2 million homes.

Exelon Nuclear is a unit of Exelon Corporation, one of the nation's largest electric utilities with approximately 5.2 million customers and more than $14 billion in annual reveniues. The company has one of the industry's largest portfolios of electricity generation capacity, with a nationwide reach and strong positions in the Midwest and Mid-Atlantic. Exelon distributes electricity to approximately 5.2 million customers in northern Illinois and Pennsylvania and gas to more than 460,000 customers in the Philadelphia area. Exelon is headquartered in Chicago and trades on the NYSE under the ticker EXC.