ML061000653

From kanterella
Jump to navigation Jump to search
E-mail from K. Mcmullin of Entergy to Various, Regarding IPEC Status Report for December 22
ML061000653
Person / Time
Site: Indian Point  
Issue date: 12/22/2005
From: Mcmullin K
Entergy Nuclear Operations
To: Boska J, Brian Holian, David Lew
Office of Nuclear Reactor Regulation
References
FOIA/PA-2006-0081
Download: ML061000653 (3)


Text

Brian McDermott - IPIEC status report for December 22 Page 1 From:

"McMullin, Kathy" <KMcMull@entergy.com>

To:

" (Popopeek~aol.com)" <Popopeek~aol.com>, " Baranski, James"

<james.baranski©semo.state.ny.us>, " Eddy, Paul" <pauleddy@ dps.state.ny.us>, " Greeley, Dan"

<greeleyd~co.rockland.ny.us>, " Gross, Steve - Orange PIO" <sgross~co.orange.ny.us>, " Meyer, Sue-Rockland Alt. POIO" <Meyers ©co.rockland.ny.us>, " Sutton, Tony" <awsl @westchestergov.com>,

Adam Stiebeling <abspcbes@bestweb.net>, "Albanese, Raymond" <rlal © westchestergov.com>, Alfredo Vidal <avidal@thevidalgroup.com>, "Anthony Sutton (awsl @weschestergov.com)"

<awsl @ weschestergov.com>, "Baker Nancy (bakerna©co.rockland.ny.us)"

<bakerna@co.rockland.ny.us>, "Barry, Terrence" <TBarry@ entergy.com>, "Benjamin, Liz"

<BenjamiL@co.rockland.ny.us>, "Bentley, Robyn" <rbentle©entergy.com>, "Bergmann Ken (ken.bergmann semo.state.ny.us)" <ken.bergmann@semo.state.ny.us>, Bernie McGarry

<mcgarry@senate.state.ny.us>, "Blizard, Andrea" <ablizar@entergy.com>, "Bob Outhouse (rjO4 © westchestergov.com)" <rjO4 © westchestergov.com>, "Bob Outhouse (rjo4 @ westchestergov.com.)"

<rjo4 © Nestchestergov.com>, "Bordewich Jean aean-bordewich ©schumer.senate.gov)"

<jean_bordewich ©schumer.senate.gov>, "Bordewich Jean (schumer@valstar.net)"

<schurnerGvalstar.net>, "Boska John jpbl @nrc.gov)" <jpbl @nrc.gov>, "Bowman, Greg"

<GBow n90Occ--exsO3.prod.entergy.com>, Brian Holian <bjm~nrc.gov>, "Brian Holian (beh~nrc.gov)"

<beh © nrc.gov>, "Bridges Jeff (JBridges @ troopers.state.ny.us)" <J Bridges © troopers.state.ny.us>, Chief Tubbs <:ChiefBTubbs ©aol.com>, Chris Schwarz <cschwar@entergy.com>, "Comiotes, Jim"

<JComiot@entergy.com>, "Conroy, Pat" <PConroy@entergy.com>, "Cooper Linda (lindac (@ yorktownny.org)" <lindac © yorktownny.org>, "Cox, Mark R" <mcox9O @ entergy.com>, "Crawford Garnes'ia (Gcrawford © urbanomics.com)" <Gcrawford © urbanomics.com>, "Curran, Nick"

<Nick.curran~mail.house.gov>, "Dacimo, Fred" <FDacimo~entergy.com>, David Brand

<DavidPBrand@hotmail.com>, David Greene <dgreene©urbanomics.com>, David Weinraub

<DWeinraub ©bmwlobby.com>, "DeGasperis, Edward" <edegasp©entergy.com>, "Dirocco, Anthony'

<ADiroc:c @ entergy.com>, "Don Maurer (Donald.Maurer~semo.state.ny.us)"

<Donald.Maurer@semo.state.ny.us>, "Dowling, Adele" <amd2 @ westchestergov.com>, "Drew Barney (Barney.Drew lafarge-na.com)" <Barney.Drew@lafarge-na.com>, "Elisa Gwilliam (elisagwilliam @ msn.com)" <elisagwilliam @ msn.com>, "Fay, Deborah" <DFayl © entergy.com>, Feathers

<jdf ©fcwc-law.com>, "Feeney Andrew (Andrew.Feeney@semo.state.ny.us)"

<Andrelv.Feeney@ semo.state.ny.us>, "Feroe Peter (peter.feroe @ mail.house.gov)"

<peter.feroeOrmail.house.gov>, Geri Shapiro <gerishapiro aol.com>, "Gibbons Emily (Emily.Giibbons © mail.house.gov)" <Emily.Gibbons © mail.house.gov>, "Giguere, Kathleen"

<KGigu qr@ entergy.com>, "Glenn Troester (grtroes ©nppd.com)" <grtroes © nppd.com>, "Gottlieb, Larry"

<LGottli © entergy.com>, "Greene, Dominick" <dgreene @co.orange.ny.us>, "Grosjean, Alain"

<AGros je © entergy.com>, "Guiao Frank (Frank.Guiao © lafarge-na.com)"

<Frank.Guiao @lafarge-na.com>, Harry Giannoulis <harry@theparksidegroup.com>, "Hipschman, Thomas" <thips9O©entergy.com>, "Huber, John T." <jhube9O©entergy.com>, "Inzirillo, Frank"

<finziri @ entergy.com>, Ira Promisel <ipromiseg©troopers.state.ny.us>, Jack Spath <jps©nyserda.org>,

"Jeff Tkacs (jefft © townofcortlandt.com)" <jefft@townofcortlandt.com>, "Jensen, Chris"

<jensenc~co.rockland.ny.us>, JES <JES1 ©westchestergov.com>, Jim Cunningham

<jim_cunningham © nyc.bm.com>, "Jim Seymour (seymour@ cityofpeekskill.com)"

<jseymour©cityofpeekskill.com>, Jim Wright <wright©senate.state.ny.us>, John Cordo

<JLCO ©cwc-law.com>, "Jones, T. R." <tjones2 entergy.com>, "Kansler, Michael"

<MKansle@entergy.com>, Kathleen Wood <kathleen.wood©chamber.state.ny.us>, "Keegan Pat (Pat.keegan @ mail.house.gov)" <Pat.keegan @ mail.house.gov>, "Kopy Mike (MKopy©troopers.state.ny.us)" <MKopy©troopers.state.ny.us>, "Kraus Kevin (kevin.kraus ©semo.state.ny.us)" <kevin.kraus ©semo.state.ny.us>, "Leach, Don"

<DLeach ©entergy.com>, "Leibell Vincent (leibell@senate.state.ny.us)" <leibell @senate.state.ny.us>,

"Leon, FPete" <Pete.Leon~mail.house.gov>, "Lew David (DCL@nrc.gov)" <DCL~nrc.gov>, "Longo, Nick"

<longon ©co.rockland.ny.us>

Date:

12/22/2005 12:10:24 PM Subjecl.:

IPEC status report for December 22 Entergy offices will be closed Dec. 23 and Dec. 26 for the Christmas Holiday

I rian McDermott - IPEC status report for Decembeir 22 Pagie 2 I Brian McDermott - IPEC status report for December22 Pacie 2

t.

Indian Point Energy Center Daily S :atus Report December 22, 2005 IP2 Off.Line to Fix Feedwater Regulator Valve Control room operators safely shut down Indian Point Unit 2 earlier this morning after noting an increasing in packing leakage on a Feedwater Regulator Valve. An increase in steam leakage from Flow Control Valve--447, the regulator valve for 24 steam generator, prompted the shutdown. The Feedwater system, which supplies water to the steam generators, is part of the secondary steam system and contains non-radioactive water.

The unit is currently in MODE 2 at 2-3 % reactor power where it will remain while the packing on the feedwa:er valve is replaced. The unit should be reconnected to the grid by the weekend.

Indian Point Unit 2 was on-line for 383 days before the shutdown. "The unit's long run is the result of focusing on safety and equipment reliability," said Paul Rubin, general manager; plant operations. "We made the safe, conservative decision to bring the unit down to fix this valve."

Indian Point 3 is unaffected by the shutdown and is operating at full power.

Spent Fuel Pool Investigation A second round of samples from three wells in the IP2 transformer yard has yielded results generally consistent with previous samples.

Please note a correction to the table included with yesterday's daily report.

Installed Monitoring Wells - Transformer Yard

[Brian-Mc-De-r-m~ott - IP'I C -st-a'tus-re-port for Decembe-r 22 Page 31 Brian McDermott-I PEC status report for December 22 Pa 3

W MW-33 12/19/05 199,000 pCi/L MW-34 1219/05 121,000 pCVL MW-35 12/19 05 76,000 pCi/L BM40.154Updated Dry Cask Storage Factsheets Available Entergy has produced an updated informational brochure, available in electronic and hardcopy formal that explains the details of dry cask storage. Contact Andrea Blizard at 914-271-7081 or by return email al kmcmullentergy.com <mailto:kmcmull~entergy.com> for a copy.

Entergy Nuclear Northeast provides customized outreach education programs for schools, youth groups, and civib organizations. The topics we cover include Emergency Planning, Understanding Radiation, Nuclear Fuel and a general overview of the operations of Indian Point Energy Center. If you would likq a brochure or are interested in scheduling a program, contact IPEC Communications at 914-271-7441.

If you have any questions or need clarification of the information provided, please contact Kathy McMullin, manager of communications, Indian Point Energy Center, at 914-271-7132.

CC:

"Sachatello, Ronald" <rsach90 @ entergy.com>