Steam Generator Examination Program for the 2006 Refueling Outage (2R17)
ML060970373
Person / Time
Site: Indian Point 
(DPR-026)
Issue date: 04/13/2006
From: Boska J
Plant Licensing Branch III-2
To: Kansler M
Entergy Nuclear Operations
Boska J, NRR, DORL, 301-415-2901
References
TAC MD0213
Download: ML060970373 (4)


Text

April 13, 2006 Mr. Michael R. Kansler President Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601

SUBJECT:

INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 - STEAM GENERATOR EXAMINATION PROGRAM FOR THE 2006 REFUELING OUTAGE (2R17)

(TAC NO. MD0213)

Dear Mr. Kansler:

By letter dated February 13, 2006, as supplemented by letter dated March 29, 2006, Entergy Nuclear Operations, Inc. (Entergy or the licensee), submitted the proposed steam generator examination program for the 2006 refueling outage (2R17) in accordance with the requirements of Indian Point Nuclear Generating Unit No. 2 (IP2) Technical Specification 5.5.7.f.1.

Entergy plans to inspect a representative sample of steam generator tubes and internals. The licensee will inspect 50% of the active steam generator tubes in all four steam generators with a bobbin coil probe. The licensee will also inspect (on a sampling basis) localized regions of the tubes (e.g., U-bends, hot leg tubes top of the tubesheet region, and hot leg tube dents and dings) with a rotating probe containing a plus point coil. In addition, the licensee plans to visually inspect the primary channel head and tubesheet, including previously plugged tubes.

On the secondary side of the steam generator, the licensee is planning to perform sludge lancing, foreign object search and retrieval, and visual in-bundle inspections.

Entergy indicated that any expansion of the inspection scope will comply with Technical Specifications and Electric Power Research Institute Pressurized Water Reactor Steam Generator Examination Guidelines. The Nuclear Regulatory Commission (NRC) staff finds the planned inspections are reasonable and are intended to ensure steam generator tube integrity consistent with NRC regulations.

Please contact me at (301) 415-2901 if you have any questions on this issue.

Sincerely,

/RA/

John P. Boska, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-247 cc: See next page

ML060970373 OFFICE LPL1-1/PM LPL1-1/LA CSGB/BC LPL1-1/BC NAME JBoska SLittle AHiser RLaufer DATE 4/10/06 4/11/06 4/12/06 4/13/06

Indian Point Nuclear Generating Unit No. 2 cc:

Mr. Gary J. Taylor Chief Executive Officer Entergy Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213 Mr. John T. Herron Senior Vice President and Chief Operating Officer Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Fred R. Dacimo Site Vice President Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Paul Rubin General Manager, Plant Operations Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 2 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Oscar Limpias Vice President Engineering Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Brian OGrady Vice President, Operations Support Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. John F. McCann Director, Licensing Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Ms. Charlene D. Faison Manager, Licensing Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. Michael J. Columb Director of Oversight Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Mr. James Comiotes Director, Nuclear Safety Assurance Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P.O. Box 249 Buchanan, NY 10511-0249 Mr. Patric Conroy Manager, Licensing Entergy Nuclear Operations, Inc.

Indian Point Energy Center 295 Broadway, Suite 1 P. O. Box 249 Buchanan, NY 10511-0249 Mr. Travis C. McCullough Assistant General Counsel Entergy Nuclear Operations, Inc.

440 Hamilton Avenue White Plains, NY 10601 Ms. Stacey Lousteau Treasury Department Entergy Services, Inc.

639 Loyola Avenue Mail Stop: L-ENT-15E New Orleans, LA 70113 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406

Indian Point Nuclear Generating Unit No. 2 cc:

Senior Resident Inspectors Office Indian Point 2 U. S. Nuclear Regulatory Commission P.O. Box 59 Buchanan, NY 10511 Mr. Peter R. Smith, President New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Eddy Electric Division New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mayor, Village of Buchanan 236 Tate Avenue Buchanan, NY 10511 Mr. Ray Albanese Executive Chair Four County Nuclear Safety Committee Westchester County Fire Training Center 4 Dana Road Valhalla, NY 10592 Mr. William DiProfio PWR SRC Consultant 139 Depot Road East Kingston, NH 03827 Mr. Daniel C. Poole PWR SRC Consultant P.O. Box 579 Inglis, FL 34449 Mr. William T. Russell PWR SRC Consultant 400 Plantation Lane Stevensville, MD 21666-3232 Mr. Jim Riccio Greenpeace 702 H Street, NW Suite 300 Washington, DC 20001 Mr. Phillip Musegaas Riverkeeper, Inc.

828 South Broadway Tarrytown, NY 10591 Mr. Mark Jacobs IPSEC 46 Highland Drive Garrison, NY 10524