Text
Committed to Nudear Excellence Palisades Nuclear Plant Operated by Nuclear Management Company, U C March 20,2006 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 Commitment Chanqe: Steam Generator Tubesheet Inspection Depth By letter dated October 29,2004, Nuclear Management Company, LLC (NMC) responded to Generic Letter 2004-01, "Requirements for Steam Generator Tube Inspections," for Palisades Nuclear Plant (PNP). The letter contained the following commitments:
NMC will submit a license amendment request, which limits the depth of inspection in the tubesheet, 90 days after the NRC approves a methodology applicable to the Palisades Nuclear Plant.
NMC will perform a full tubesheet inspection with the +pointTM probe or equivalent on at least 3% of the active steam generator tubes on the hot leg side until a license amendment request is approved for the Palisades Nuclear Plant.
By letter dated August 22, 2005, NMC responded to a request for additional information (RAI) on NMC's response to Generic Letter (GL) 2004-01, for PNP. In the letter, the following commitment was revised:
Commitment made by letter dated October 29,2004:
NMC will submit a license amendment request, which limits the depth of inspection in the tubesheet, 90 days after the NRC approves a methodology applicable to the Palisades Nuclear Plant.
Revised commitment:
NMC will use the methodology in WCAP-16208-P to determine steam generator tubesheet inspections to be included in the suweillance program requirements starting in the 2007 refueling outage.
27780 Blue Star Memorial Highway Covert, Michigan 49043-9530 Telephone: 269,764.2000
Document Control Desk Page 2 A teleconference was held with the NRC staff on March 14,2006, to discuss changes to the above commitments. Based on these discussions, NMC is revising the above commitments by replacing them with a commitment to implement WCAP-I 6208-P, "NDE inspection Length for CE Steam Generator Tubesheet Region Explosive Expansions," in the 2006 refueling outage at PNP. The NRC staff noted recent RAls on WCAP-16208-P that could potentially affect the inspection depth into the tubesheet, namely the issue of T-hot effect and the use of first slip loads. NMC agreed to address these issues in regards to determining the 2006 refueling outage tubesheet inspection depth. NMC also agreed to submit a license amendment request to include WCAP-16208-P in the surveillance program requirements of the Steam Generator Program.
Summaw of Commitments This letter contains one new commitment and one revision to existing commitments.
One new commitment follows:
NMC will submit a license amendment request to include WCAP-16208-P in the surveiltance program requirements of the Steam Generator Program by May 31,2006.
Current commitments to be revised:
NMC will perform a full tubesheet inspection with the +pointm probe or equivalent on at least 3% of the active steam generator tubes on the hot leg side until a license amendment request is approved for the Palisades Nuclear Plant.
NMC will use the methodology in WCAP-16208-P to determine steam generator tubesheet inspections to be included in the surveillance program requirements starting in the 2007 refueling outage.
Revised commitment:
NMC will use the methodology in WCAP-16208-P to determine the steam generator tubesheet inspection depth to be implemented during the 2006 refueling outage. The issues of T-hot effect and use of slip loads will be included in determining the appropriate tubesheet inspection depth at PNP.
Site Vice President, Palisades Nuclear Plant Nuclear Management Company, LLC Administrator, Region Ill, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC