ML060600397
| ML060600397 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 02/15/2006 |
| From: | Joyce T Public Service Enterprise Group |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| GL-06-001, LR-N06-0054 | |
| Download: ML060600397 (3) | |
Text
PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 FE 1 5 2006 OPSEG LR-N06-0054 Nuclear LLC United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 RESPONSE TO NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS SALEM GENERATING STATION - UNIT 2 DOCKET NO. 50-311 FACILITY OPERATING LICENSE NO. C)PR-75 In accordance with the provisions of 10 CFR 50.54(f), PSEG Nuclear, LLC (PSEG) hereby transmits the information required by Option 1 of Generic Letter (GL) 2006-01.
The information provided below is specific to Salem Unit 2; Salem Unit 1 was exempted from the provision of GL 2006-01 as discussed in the GL. Pursuant to the requirements of 1 OCFR50.91 (b)(1), a copy of this letter has been sent to the State of New Jersey.
PSEG commits to submitting a License Change Request (LCR) to modify the Steam Generator portion of Salem Unit 2 Technical Specifications (TS) that is consistent with TSTF-449, Revision 4, uSteam Generator Tube Integrity." The request will be submitted by May 31, 2006. The proposed changes of the Unit 2 request will be similar to changes previously approved in Amendment 268 for Salem Unit 1, dated October 14, 2005. summarizes the regulatory commitments made in this submittal.
Should you have any questions regarding this request, please contact Mr. Enrique Villar at (856) 339-5456.
I declare under penalty of perjury that the! foregoing is true and correct.
Executed on
-ZltKlo 6 Sincerely, (D te) ce7-Tom Joyce Site Vice President Salem Generating Station Attachments (1) 95-2168 REV. 7/99
Document Control Desk ELR-N06-0054 FED 1 6 200 C
Mr. S. Collins, Administrator - Region I U. S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. S. Bailey, Licensing Project Manager - Salem U. S. Nuclear Regulatory Commission Mail Stop 08B1 Washington, DC 20555 USNRC Senior Resident Inspector - Salem Unit 1 and Unit 2 (X24)
Mr. K. Tosch, Manager IV Bureau of Nuclear Engineering P. O. Box 415 Trenton, NJ 08625
a LR-N06-0054 LIST OF REGULATORY COMMITMENTS The follcw.^ing table identifies those actions committed to by PSEG in this document.
Any other statements in this submittal are provided for information only purposes and are not considered to be regulatory commitments. Please direct questions regarding these commitments to Mr. E~nrique Villar at (856) 339-5456.
Regulatory Commitment Due DatefEvent PSEG will submit a License Change Request (LCR) to May 31, 2006 modify the Steam Generator portion cf Salem Unit 2 Technical Specifications (TS) that is consistent with TSTF-449, Revision 4.
_