February 17, 2006 Mr. James A. Spina, Vice President Calvert Cliffs Nuclear Power Plant, Inc.

Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702

SUBJECT:

CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NO. 2 - PRELIMINARY ACCIDENT SEQUENCE PRECURSOR ANALYSIS OF JANUARY 2004 OPERATIONAL EVENT

Dear Mr. Spina:

The Nuclear Regulatory Commission (NRC) has prepared the enclosed preliminary accident sequence precursor (ASP) analysis of an operational event that occurred at Calvert Cliffs Nuclear Power Plant, Unit No. 2 in January 2004. On January 23, 2004, the unit experienced excessive steam demand following a reactor trip due to low steam generator water level after a feedwater pump trip. This event was documented by Calvert Cliffs Nuclear Power Plant, Inc.

(the licensee) in licensee event report (LER) 318/04-001-00, dated January 23, 2004, and in NRC Special Inspection Report No. 50-318/2004-008, dated July 29, 2004, and Supplemental Inspection Report No. 50-318/2005-006, dated February 11, 2005. Since the ASP analysis is preliminary, it is not available to the public.

The NRC staff requests that the licensee perform a peer review of the preliminary ASP analysis and provide any comments that it may have by March 31, 2006. Any comments from the review will be factored into the final ASP analysis, which will be publicly available.

If you have any questions regarding this matter, please call me at 301-415-1457.

Sincerely,

/RA/

Patrick D. Milano, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-318

Enclosure:

Preliminary ASP Analysis cc w/o encl: See next page

ML060480069 OFFICE LPLI-1/PM LPLI-1/LA RES/OERAB/BC R-I/DRP/BC LPLI-1/BC NAME PMilano:tsw1 SLittle NChokshi JTrapp RLaufer DATE 02/16/06 02/16/06 01/26/06 02/16/06 02/17/06

DISTRIBUTION (w/o enclosure): for letter to J. Spina dated PUBLIC (cover letter only)

LPLI-1 Reading File R. Laufer RidsNrrDorlLpli-1 S. Little RidsNrrLASLittle P. Milano RidsNrrPMPMilano OGC RidsOgcRp ACRS RidsAcrsAcnwMailCenter J. Trapp, DRP, R-I RidsRgn1MailCenter

E. Goldfeiz RidsResDraaOera G. DeMoss, RES C. Hunter, RES cc w/o encl: Plant Mailing List

Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 cc:

President Calvert County Board of Commissioners 175 Main Street Prince Frederick, MD 20678 Mr. Carey Fleming, Esquire Sr. Counsel - Nuclear Generation Constellation Generation Group, LLC 750 East Pratt Street, 17th floor Baltimore, MD 21202 Mr. Louis Larragoite Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 287 St. Leonard, MD 20685 Mr. R. I. McLean, Manager Nuclear Programs Power Plant Research Program Maryland Department of Natural Resources 580 Taylor Avenue (B wing, 3rd floor)

Tawes State Office Building Annapolis, MD 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Ms. Kristen A. Burger, Esquire Maryland People's Counsel 6 St. Paul Centre Suite 2102 Baltimore, MD 21202-1631 Ms. Patricia T. Birnie, Esquire Co-Director Maryland Safe Energy Coalition P.O. Box 33111 Baltimore, MD 21218 Mr. Roy Hickok NRC Technical Training Center 5700 Brainerd Road Chattanooga, TN 37411-4017