ML060330744

From kanterella
Jump to navigation Jump to search

Request for Additional Information Regarding Relief Request to Use Alternative Techniques for Repair of Welded Nozzles (TAC Nos. MC9583 and MC9584)
ML060330744
Person / Time
Site: Calvert Cliffs  Constellation icon.png
Issue date: 02/03/2006
From: Milano P
Plant Licensing Branch III-2
To: Spina J
Calvert Cliffs
Milano P, NRR/DLPM ,415-1457
References
TAC MC9583, TAC MC9584
Download: ML060330744 (4)


Text

February 3, 2006 Mr. James A. Spina, Vice President Calvert Cliffs Nuclear Power Plant, Inc.

Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702

SUBJECT:

CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NOS. 1 AND 2 -

REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST TO USE ALTERNATIVE TECHNIQUES FOR REPAIR OF WELDED NOZZLES (TAC NOS. MC9583 AND MC9584)

Dear Mr. Vanderheyden:

By letter dated December 21, 2005 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML053620026), Calvert Cliffs Nuclear Power Plant, Inc. (the licensee) submitted a relief request to use alternative repair and examination techniques for repair of unacceptable indications in welded nozzles at Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 (Calvert Cliffs). Specifically, the licensee requested relief from certain requirements of American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code),

Section XI, concerning repair or replacement activities for pressure-retaining welds subject to Article IWA-4000. The licensee has proposed to use a half-nozzle design to repair any existing hot leg instrument nozzle with identified leakage using the techniques based on Westinghouse Electric Company Report WCAP-15973-P, Revision 1, Low-Alloy Steel Component Corrosion Analysis Supporting Small-Diameter Alloy 600/690 Nozzle Repair/Replacement Program. In its safety evaluation (SE) dated January 12, 2005, approving WCAP-15973-P, the Nuclear Regulatory Commission (NRC) staff stated that half-nozzle repairs are considered alternatives to the ASME Code. Therefore, the licensee shall submit the required information in WCAP-15973-P, by the conditions of the SE, as a relief request in accordance with Section 50.55a of Part 50 of Title 10 of the Code of Federal Regulations.

The NRC staff has reviewed the information provided in support of the relief request and has determined that additional information is needed. In this regard, the NRC staff requests the licensee submit a copy of (1) the welding procedure specification(s) that will be used for weld buildup and attachment welds, and (2) a description of any non-destructive examination that will be performed for final acceptance of each repaired instrument nozzle using the alternative technique. This request for additional information was discussed with your staff on February 2, 2006, and it was agreed that your response would be provided within 30 days from the date of this letter.

J. Spina If you should have any questions regarding this request, please contact me at 301-415-1457.

Sincerely,

/RA/

Patrick D. Milano, Senior Project Manager Plant Licensing Branch I-1 Division of Operating reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-317 and 50-318 cc: See next page

ML060330744 OFFICE LPLI-1/PM LPLI-1/LA CFEB/BC LPLI-1/BC NAME PMilano SLittle KGruss RLaufer DATE 02/01/06 02/02/06 02/02/06 02/03/06 Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 cc:

President Ms. Patricia T. Birnie, Esquire Calvert County Board of Co-Director Commissioners Maryland Safe Energy Coalition 175 Main Street P.O. Box 33111 Prince Frederick, MD 20678 Baltimore, MD 21218 Mr. Carey Fleming, Esquire Mr. Roy Hickok Sr. Counsel - Nuclear Generation NRC Technical Training Center Constellation Generation Group, LLC 5700 Brainerd Road 750 East Pratt Street, 17th floor Chattanooga, TN 37411-4017 Baltimore, MD 21202 Mr. Louis Larragoite Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 287 St. Leonard, MD 20685 Mr. R. I. McLean, Manager Nuclear Programs Power Plant Research Program Maryland Department of Natural Resources 580 Taylor Avenue (B wing, 3rd floor)

Tawes State Office Building Annapolis, MD 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Ms. Kristen A. Burger, Esquire Maryland People's Counsel 6 St. Paul Centre Suite 2102 Baltimore, MD 21202-1631