ML060040172

From kanterella
Jump to navigation Jump to search

Draft RAI Re. ISI Relief Request No. 13, Dated 9/27/05
ML060040172
Person / Time
Site: Monticello 
(DPR-022)
Issue date: 01/04/2006
From: Tam P
Plant Licensing Branch III-2
To: Loeffler R
Nuclear Management Co
References
TAC MC8882
Download: ML060040172 (2)


Text

From:

Peter Tam To:

Loeffler, Rick Date:

1/4/06 7:54AM

Subject:

Monticello: Draft RAI re. ISI Relief Request No. 13, dated 9/27/05 (TAC MC8882)

Rick:

Please note the TAC number for this review.

Our reviewer Tom McLellan has the following question/comment which we would like to discuss with you in a conference call. Please call me to set it up.

In the "basis for use" you referenced EPRI Report IR-2004-63 "Monticello Nozzle Inner Radius and Nozzle-to-Shell Weld Examinations" by defining the scan parameters for each nozzle configuration. As a reminder, the basis for each request for relief is to stand alone on its own merit. This includes the examination requirements such as the scan parameters and as to why they are impractical to perform. Please provide either a description of the scan parameters contained in the EPRI Report IR-2004-63 or provide copies of the pertainment sections of the subject report.

This e-mail aims solely to prepare you and others for the requested conference call. It does not convey a formal NRC staff position, nor does it formally request for information.

Disposition of the question/comment will occur in the conference call.

Peter S. Tam, Senior Project Manager Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation e-mail: pst@nrc.gov Tel.: 301-415-1451

CC:

McLellan, Thomas; Mitchell, Matthew Mail Envelope Properties (43BBC572.18F : 12 : 334)

Subject:

Monticello: Draft RAI re. ISI Relief Request No. 13, dated 9/27/05 (TAC MC8882)

Creation Date:

1/4/06 7:54AM From:

Peter Tam Created By:

PST@nrc.gov Recipients Action Date & Time nmcco.com Transferred 01/04/06 7:54 AM Richard.Loeffler (Rick Loeffler) nrc.gov TWGWPO01.HQGWDO01 Delivered 01/04/06 7:54 AM TKM CC (Thomas McLellan)

Opened 01/04/06 7:56 AM nrc.gov owf2_po.OWFN_DO Delivered 01/04/06 7:54 AM MAM4 CC (Matthew Mitchell)

Opened 01/04/06 8:06 AM Post Office Delivered Route nmcco.com TWGWPO01.HQGWDO01 01/04/06 7:54 AM nrc.gov owf2_po.OWFN_DO 01/04/06 7:54 AM nrc.gov Files Size Date & Time MESSAGE 2093 01/04/06 07:54AM Options Auto Delete:

No Expiration Date:

None Notify Recipients:

Yes Priority:

Standard Reply Requested:

No Return Notification:

None Concealed

Subject:

No Security:

Standard To Be Delivered:

Immediate Status Tracking:

Delivered & Opened