To:
- Prom:
Rich Brooks
Subject:
Date:
11/29/05 Walkthrough Changes to Operating exam Listed below is a summary of the changes we made, to the operating exam, as a result of the reviews conducted during the walkthrough week of November 14h 2005.
Simulator JPMs 79.0P.006.102 S/U CRM A 00.ON.015.104 Establish and Maintain RPV pressure with SRVs from RSDP 98.G0.001.15 1 Synchronize the Main Generator 58.0P.008.101 Transfer RPS power supplies 52.0P.009.15 1 Secure HPCI (with several malfunctions inserted) 0 Ended JPM AmER step 26.
Enhanced one Evaluator Cue 0
Nochanges Changed title of JPM 55.0N.007.152 Respond to a Stuck Rod 0
45.0P.004.151 Commence Feeding with C RF (Respond to Hi Vibrations) 0 Nochanges 73.0P.001.101 Vent the Drywell Added an Evaluator note.
Deleted alternate path portion of the JPM Added an Evaluator note and cue.
Reduced increasing drive water pressure to ONE attempt.
Admin JPMs 79.AD.001.101 Document a Failed LPRM detector.
Enhanced several evaluator notes and cues 00.AD.273.002 Determine TRO applicability and complete LCO/TRO log sheet Added clarification for why repetitive action sheet is Not required.
45.0N.007.101 DetermineRespond to RPV water level anomaly 00.AD.269.101 Determine Trip inputs to Zone 3 isolation lockout relay.
69.0P.044.05 1 Review and Approve Radioactive Liquid Release Permit 00.EP.004.002 Control Room Communicator Emergency Notification 00.EP.001.304, 305,504, 505, & 602 E-Plan Classification 0
Nochanges Nochanges 0
Enhanced Evaluator cues.
Enhanced Evaluator cues.
Nochanges Page 1 of 2
Plant JPMs 55.0P.007.001 Shift CRD Flow Stations Enhanced several Evaluator Cues 50.0P.004.152 Establish and maintain Reactor Vessel Level from RSDP.
Nochanges 24.0P.001.007 Transfer of DG E for DG C.
Enhanced several Evaluator Cues Simulator Scenarios LO-304 0
Modified initial setup to include RCIC out of service for maintenance.
LO-305 0
0 Modified Field operator report for DG D inadvertent start.
Added Rx Bldg. Evacuation announcement to student activity.
Added NOTE: to inform lead evaluator when 2 max. safe radiation levels are exceeded.
LO-504 NoChanges LO-505 0
0 Removed EHC oscillations from the scenario Revised scenario to insure HPCI does not restart ILO-602 0
Determined D MSL failure and RCIC speed controller failure do not contain enough operator actions to be considered failures on the ES-D-1 forms, however they will remain in the scenario to maintain the flow of the scenario.
Modified to include alternate success path.
0 Page 2 of 2