ML053340498

From kanterella
Jump to navigation Jump to search

Request for Use of Delta Protection Suits
ML053340498
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 12/21/2005
From: Terao D
NRC/NRR/ADRO/DORL/LPLG
To: Oatley D
Pacific Gas & Electric Co
Wang A, NRR/DLPM, 415-1445
References
TAC MC9005, TAC MC9006
Download: ML053340498 (8)


Text

December 21, 2005 Mr. David H. Oatley Vice President and Acting CNO Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56 Avila Beach, CA 93424

SUBJECT:

DIABLO CANYON POWER PLANT, UNIT NOS. 1 AND 2 - USE OF ASSIGNED PROTECTION FACTOR WITH THE USE OF FRENCH-DESIGNED AIR SUPPLIED RESPIRATOR EQUIPMENT (TAC NOS. MC9005 AND MC9006)

Dear Mr. Oatley:

By letter dated October 7, 2005, Pacific Gas and Electric Company (PG&E) requested U.S. Nuclear Regulatory Commission (NRC) authorization, pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Section 20.1705, to: (1) use French-designed respiratory protection equipment that has not been tested and certified by the National Institute for Occupational Safety and Health; (2) not provide standby rescue persons whenever this equipment is used; and, (3) take credit for an assigned protection factor of 5,000 for this equipment.

The NRC staff concludes in the enclosed safety evaluation that the PG&E request is acceptable, and within the provisions of 10 CFR Part 20. Therefore, you are authorized to use the Mururoa air-supplied suits, models V4 F1 and V4 MTH2, with an assigned protection factor of 5,000, and whenever this equipment is used you do not need to provide standby rescue persons at the Diablo Canyon Power Plant, Unit Nos. 1 and 2.

If you or your staff have any questions concerning the resolution of this matter, please contact Alan B. Wang at 301-415-1445.

Sincerely,

/RA/

David Terao, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323

Enclosure:

Safety Evaluation cc w/encl: See next page

December 21, 2005 Mr. David H. Oatley Vice President and Acting CNO Pacific Gas and Electric Company Diablo Canyon Power Plant P.O. Box 56 Avila Beach, CA 93424

SUBJECT:

DIABLO CANYON POWER PLANT, UNIT NOS. 1 AND 2 - USE OF ASSIGNED PROTECTION FACTOR WITH THE USE OF FRENCH-DESIGNED AIR SUPPLIED RESPIRATOR EQUIPMENT (TAC NOS. MC9005 AND MC9006)

Dear Mr. Oatley:

By letter dated October 7, 2005, Pacific Gas and Electric Company (PG&E) requested U.S. Nuclear Regulatory Commission (NRC) authorization, pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Section 20.1705, to: (1) use French-designed respiratory protection equipment that has not been tested and certified by the National Institute for Occupational Safety and Health; (2) not provide standby rescue persons whenever this equipment is used; and, (3) take credit for an assigned protection factor of 5,000 for this equipment.

The NRC staff concludes in the enclosed safety evaluation that the PG&E request is acceptable, and within the provisions of 10 CFR Part 20. Therefore, you are authorized to use the Mururoa air-supplied suits, models V4 F1 and V4 MTH2, with an assigned protection factor of 5,000, and whenever this equipment is used you do not need to provide standby rescue persons at the Diablo Canyon Power Plant, Unit Nos. 1 and 2.

If you or your staff have any questions concerning the resolution of this matter, please contact Alan B. Wang at 301-415-1445.

Sincerely,

/RA/

David Terao, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323

Enclosure:

Safety Evaluation cc w/encl: See next page DISTRIBUTION:

PUBLIC RidsNrrDorlLplg (DTerao)

LPLIV Reading RidsNrrLALFeizollahi RidsNrrDorl (CHaney/CHolden)

RidsOgcRp RidsNrrPMAWang RidsAcrsAcnwMailCenter RidsRegion4MailCenter (BJones)

ADAMS Accession Number: ML053340498 OFFICE LPL4/PM LPL4/LA DIRS/ITSB OGC LPL4/BC NAME AWang LFeizollahi SKlementowicz MRothschild DTerao DATE 12/21/05 12/21/05 10/25/05 11/10/05 12/21/05 OFFICIAL RECORD COPY

Enclosure SAFETY EVALUATION BY THE OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFGUARDS RELATED TO USE OF FRENCH-DESIGNED RESPIRATORY PROTECTION EQUIPMENT WITH A PROTECTION FACTOR OF 5,000 PACIFIC GAS AND ELECTRIC COMPANY DIABLO CANYON POWER PLANT, UNITS 1 AND 2 DOCKET NOS. 50-275 AND 50-323

1.0 INTRODUCTION

By letter dated October 7, 2005, Pacific Gas and Electric Company (PG&E, the licensee) requested U.S. Nuclear Regulatory Commission (NRC) authorization, pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Section 20.1705, to: (1) use French-designed respiratory protection equipment that has not been tested and certified by the National Institute for Occupational Safety and Health (NIOSH); (2) not provide standby rescue persons whenever this equipment is used; and, (3) take credit for an assigned protection factor (APF) of 5,000 for this equipment.

PG&E requested to use an APF greater than that listed in Appendix A to 10 CFR Part 20, for persons working in areas of airborne radioactivity with certain respiratory protection equipment that has not been certified by NIOSH. Specifically, PG&E requested authorization to use an APF of 5,000 with the Mururoa air-supplied suits, models V4 F1 and V4 MTH2, manufactured by Delta Protection.

2.0 REGULATORY EVALUATION

Part 20 to 10 CFR, Standards for Protection Against Radiation, Subpart H, Respiratory Protection and Controls to Restrict Internal Exposure in Restricted Areas, concerns the use of respiratory protection equipment for protection against airborne radioactive materials.

Section 20.1703, Use of individual respiratory protection equipment, paragraph(a), requires that respiratory protection equipment used by a licensee to limit the intake of radioactive material be tested and certified by NIOSH. Section 20.1703(b) states that a licensee can submit an application to the NRC for authorized use of respiratory protection equipment that has not been tested and certified by NIOSH.

Appendix A to 10 CFR Part 20, Assigned Protection Factors for Respirators, does not provide an APF for atmosphere supplying respirator (air-line respirator) suits in a continuous-flow operating mode. Instead, it references footnote (g) that states, No NIOSH approval schedule

is currently available for atmosphere supplying suits. This equipment may be used in an acceptable respiratory protection program as long as all the other minimum program requirements, with the exception of fit testing, are met (i.e., § 20.1703).

Section 20.1705, Application for use of higher assigned protection factors, states that a licensee shall obtain NRC authorization before using assigned protection factors in excess of those specified in Appendix A to Part 20. Thus, PG&E must obtain NRC approval to take credit for an APF for the French-designed respiratory protection equipment.

Criteria and background information used for the NRC staffs technical evaluation include 10 CFR Part 20, Subpart H; 10 CFR Part 19, paragraph 19.12, "Instruction to workers; Regulatory Guide 8.15, Revision 1, "Acceptable Programs for Respiratory Protection; NUREG/CR-0041, Revision 1, "Manual of Respiratory Protection Against Airborne Radioactive Materials; 42 CFR Part 84, which addresses NIOSH testing and certification regulations; Los Alamos National Laboratory Report LA-101560MS, "Acceptance Testing Procedures for Air-Line Supplied Air Suits; and American National Standards Institute standard ANSI Z88.2-1992, "American National Standard Practices for Regulatory Protection."

3.0 TECHNICAL EVALUATION

NRC guidance provided in NUREG/CR-0041 encourages the use of suits, noting that in certain work environments, air-supplied suits may be the best respiratory device when considering heat stress, trying to minimize skin contamination, and trying to maintain worker doses as low as reasonably achievable (ALARA).

Testing conducted by the Institute for Nuclear Protection and Security, the European certifying agency (comparable to NIOSH), and over 20 years of successful use in European power plants of similar certified suits form the basis for the PG&E request. PG&E has requested authorization to take credit for the protection provided by two suits when used during normal (non-emergency) operations. The two suits are made by the same manufacturer and are identified as Mururoa V4 F1 and Mururoa V4 MTH2 (Certificate Nos. 0073/197/162/12/97/0028 and 0073/197/162/01/96/0001, respectively). Both models have been approved as single-use suits (a suit that is disposed of after one use), and PG&E proposes to use the suits in the approved configurations, relative to the suits form, fit, and function.

The European Standard CEN/EN 1073-1 (January 1998), Protective Clothing Against Radioactive Contamination, Part 1: Requirements and Test Methods for Ventilated Protective Clothing Against Particulate Radioactive Contamination, provided testing and acceptance criteria used for certification of the suits. This standard is generally consistent with the pertinent acceptance criteria provided in Los Alamos National Laboratory Report LA-10156-MS, which is used to test and authorize the use of air-supplied suits at the Department of Energy sites.

The certification-testing regime was broadly based and encompassed a range of various functional areas, including: suit material strength, tear and puncture resistance, material flammability, wearer comfort, noise level, wearer visibility, air flow, carbon dioxide concentrations, and degree of contaminate in-leakage during a series of varied, simulated work practices and exercises. Both models passed all required tests, and both provided a measured average protection level (fit factor) of 50,000. A fit factor, which was developed in a simulated work environment, is the ratio of contaminate concentration outside the suit to the contaminate

concentration inside the suit. Given an overall measured fit factor of 50,000 (averaged over all exercise activities), allowing an APF of 5,000 provides a conservative safety factor for estimating the actual protection provided to the user by the suit in the actual working environment. APFs are generally lower than fit factors for all types of respirators, since workplace demands are typically greater on the user of the respirator than are laboratory conditions and simulated work activities due to higher heat and humidity, longer work durations, greater worker fatigue, etc.

In general, when compared with other air-fed respirators, both Mururoa suit models provide the following advantages to the user: (1) one piece single-use suit that includes welded gloves and booties with tie straps; (2) fire proof (up to 65 °C); (3) made of Poly Vinyl Chloride (PVC) or Ethyfuge with reinforced elbows, knees and crotch areas; (4) dual zippers - metal zipper inside and plastic zipper outside; (5) a helmet made of clear PVC material that provides distortion-free vision and large enough for wearing a headset; (6) a welded sleeve to insert a communication cable; (7) a removable strip near the mouth that could be used for emergency breathing in case of loss of supplied air; (8) an egress strip stretching from the left arm, over the head, to the right arm that is used for undressing and for self-rescue in an emergency, such as loss of supplied air; (9) an air intake located at the waist with a built-in regulator that can adjust, but not block, air flow; (10) two exhaust valves that provide ventilation, and also protect from over pressure; (11) very low noise level at maximum air flow and (12) air flow to hands, feet, face, and chest.

Safety features also include lightweight (2.5 pounds), one-piece construction with welded gloves and booties with tie straps. Helmets are made with PVC material that provides distortion-free vision and are large enough for wearing a headset. Noise levels are less than 80 decibels at maximum air flow, and air flow can be adjusted by the user for comfort, but cannot be throttled to below the required minimum air flow. The Mururoa V4 MTH2 model also provides two additional vents near the chin for cooling to the face. Both models are heat resistant to 65 oC and can be used in temperatures up to 60 oC. Suits are constructed with reinforced elbow, knee, and crotch areas.

PG&E intends to use the suits during decontamination and decommissioning evolutions at Humboldt Bay Power Plant and during steam generator replacement and reactor head replacement at Diablo Canyon Power Plant. Both Mururoa suit models offer a safer and more efficient means to protect workers in areas of high-radiological contamination and in areas where there is a potential for airborne contamination. The existing practice of using a combination of rain suits and NIOSH-certified air-supplied hoods provides cooling only to the head and forces workers to wear the ensemble in a manner that makes self-rescue nearly impossible; thus, a rescue worker is required to be stationed nearby. The Mururoa suits provide improved cooling over the entire body, and the ease-of-removal features provide a means to undress that minimizes the potential for personnel contamination events and an easy-escape design.

Upon loss of supplied air to the suit, a worker can easily extricate himself or herself from the suit by pulling off the mouth strip and then opening the hood, or by pulling the egress strip from the forearm to the head. Based on these safety features, the NRC staff finds that the suit design provides for easy and effective self-rescue, thus, avoiding asphyxiation if the air supply is interrupted or lost. Because this design allows an unaided individual to easily extricate himself or herself from the suit, standby rescue personnel are not required, as specified by 10 CFR 20.1703(f).

Subpart H of 10 CFR Part 20 establishes the requirements for implementing a respiratory protection program. These programmatic requirements ensure that worker doses from airborne radioactive materials are maintained ALARA. PG&E intends to integrate the use of the Mururoa suits into their existing, ongoing respiratory protection programs that satisfy 10 CFR Part 20 requirements. The NRC staff finds this approach acceptable. The following summary of controls and program elements generally follow the specific 10 CFR Part 20 requirements pertinent to the use of air-supplied suits. Since PG&E has a viable, ongoing respiratory protection program, only items specific to the use of suits are discussed below.

1.

Section 20.1703(c) requires, among other things, written procedures governing the training of respirator users (workers). PG&E has committed to develop new lesson plans to train workers on the suits features, donning, use and removal, cautions, and use of the mouth strip and tear off strips for routine and emergency egress. This training should include appropriate hands-on and classroom instruction. Specific training will be provided on actions to be taken by the user in the event of an equipment malfunction. Radiation Protection personnel will be provided additional training for selection, approval, issue, equipment set-up, and operation and maintenance instructions for the suits.

2.

Communication channels will be established and maintained between PG&E, the manufacturer and the European certification authority to ensure that users are notified in a timely manner of significant problems that may affect suit safety, performance, or function. Depending on the severity of a problem or defect, the certification agency or the manufacturer may issue a product recall (e.g., a stop-use advisory or user warning issued to all registered users). PG&E has committed to use their Corrective Action Program to document any unexpected problems with the suits and track corrective actions taken. PG&E will report to the manufacturer any defects or incidences that may occur with the suits.

3.

Section 20.1703(c)(4)(vii) requires, among other things, written procedures governing respirator storage and quality assurance. PG&E has committed to implement the provisions in the manufacturers instructions for use and emergency features (ref. Delta, Mururoa V4F1 and MTH2 V4, Instructions for Use, NO/841442T), with the minor clarification that the suits will be inspected and removed from their protective packaging outside of the plants radiological controlled areas, in a way that maintains the integrity of the suit, but does not lead to the unnecessary generation of solid radioactive waste.

4.

The Mururoa suits are single use only, and are not approved for use in atmospheres that are immediately deleterious to life and health (IDLH). PG&E has committed to discarding each suit after one use and that they will not be used in environments that are IDLH.

4.0 CONCLUSION

Based on the testing data provided, and when used in accordance with the applicable manufacturers instructions, licensee commitments, and requirements of Subpart H of 10 CFR Part 20, the NRC staff concludes that the PG&E request to use the Mururoa V4 F1 and V4 MTH2 supplied air suits satisfies the 10 CFR Part 20 ALARA requirements, and will provide the suit wearer with an adequate level of protection while working in potentially high airborne

radioactivity areas. Therefore, the NRC staff finds that the request is acceptable. The NRC staff also concludes that PG&E can take credit for an APF of 5,000 for both of these suits, and that the standby rescue personnel, discussed in 10 CFR 20.1703(f), are not required when these suits are used.

Principal Contributors: John Hickman Roger Pedersen (By Precedent)

Date: December 21, 2005

December 2005 Diablo Canyon Power Plant, Units 1 and 2 cc:

NRC Resident Inspector Diablo Canyon Power Plant c/o U.S. Nuclear Regulatory Commission P.O. Box 369 Avila Beach, CA 93424 Sierra Club San Lucia Chapter c/o Henriette Groot 1000 Montecito Road Cayucos, CA 93430 Ms. Nancy Culver San Luis Obispo Mothers for Peace P.O. Box 164 Pismo Beach, CA 93448 Chairman San Luis Obispo County Board of Supervisors Room 370 County Government Center San Luis Obispo, CA 93408 Mr. Truman Burns Mr. Robert Kinosian California Public Utilities Commission 505 Van Ness, Room 4102 San Francisco, CA 94102 Diablo Canyon Independent Safety Committee ATTN: Robert R. Wellington, Esq.

Legal Counsel 857 Cass Street, Suite D Monterey, CA 93940 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Richard F. Locke, Esq.

Pacific Gas & Electric Company P.O. Box 7442 San Francisco, CA 94120 City Editor The Tribune 3825 South Higuera Street P.O. Box 112 San Luis Obispo, CA 93406-0112 Mr. Ed Bailey, Chief Radiologic Health Branch State Department of Health Services P.O. Box 997414 (MS 7610)

Sacramento, CA 95899-7414 Mr. James D. Boyd, Commissioner California Energy Commission 1516 Ninth Street (MS 31)

Sacramento, CA 95814 Mr. James R. Becker, Vice President Diablo Canyon Operations and Station Director Diablo Canyon Power Plant P.O. Box 3 Avila Beach, CA 93424 Jennifer Tang Field Representative United States Senator Barbara Boxer 1700 Montgomery Street, Suite 240 San Francisco, CA 94111