Text
2 1
3 15 14 13 12 11 10 9
8 7
6 5
4 F
E D
C B
F E
D C
B K
J H
G K
J H
G 13 14 15 A
PDS2-E1 R0 (9/94)
DWN CHK APVD 4
DESCRIPTION 5
6 DATE REV 7
8 9
10 11 12 COLUMBIA GENERATING STATION TITLE DATE SIGNATURE REV.
APPROVED CHECKED SCALE DRAWN 3
1 2
DWG NO.
A FLOW DIAGRAM NUCLEAR BOILER RECIRCULATION SYSTEM M530-1 80 NTS 4WARDTECH 6-28-99 K. LUCAS 1-9-02 DONALD R. JACOBSEN 4-19-02 SERVER84\\00\\dwg FR 613 B22-R613 MS FROM MS-DPT-32 B22-N032 (G/12)
T C
F 606 B22-K606 MS F
608 B22-K608 MS FROM MS-FSUM-602B B22-K602B (K/5)
FI 611A B22-R611A MS F
602A B22-K602A MS T
F 607A B22-K607A MS F
601A B22-K601A MS SQRT 600V B22-K600V MS DPI 608V B22-R608V MS FT 34V B22-N034V MS C
TYP.
OF 5 T=JP-9 V=JP-10 FROM MS-SQRT-600T, V B22-K600T, V A=JP-1 C=JP-2 E=JP-3 G=JP-4 FROM MS-SQRT-600A, C, E, G, B22-K600A, C, E, G F
601C B22-K601C MS L=JP-6 N=JP-7 R=JP-8 J=JP-5 FROM MS-SQRT-600J, L, N, R B22-K600J, L, N, R 1"RRC(5)-4S-1 &
1"RRC(5)-4S-2 2b 2a C 215 C 2 2a 2b C 2 C 220 1"PI(1)-4S-X-40f &
1"PI(1)-4S-X-41f 3/4" TE J,J B
B1 B2 D
HEAT EXCHANGER A1 A
PUMP STUFFING BOX E1 E
F (F/6-9)
M525-1 SPARE THERMO WELL DETAIL "D" SEAL INJECTION WATER LR 615 B22-R615 MS MS T
LT 44A B22-NO44A JP-10 AS SHOWN (MS-FT-34V)
TYP. FOR JP-6 THRU JP-9 (FT-B22-NO34L, N, R, T)
FT 33C B22-NO33C FI 609C B22-R609C MS SQRT 605C B22-K605C MS FOR CALIBRATED JET PUMP "10" ONLY T
FT 34J B22-NO34J SQRT 600J B22-K600J MS TYP. OF 5 C
DPI 608J B22-R608J MS JP-5 AS SHOWN (MS-FT-34J)
TYP FOR JP-1 THRU JP-4 (MS-FT-34A, C, E, G)
SQRT 605A B22-K605A MS FI 609A B22-R609A MS T
FT 33A B22-NO33A MS MS DPIS 12A E31-N012A FOR CALIBRATED JET PUMP "5" ONLY 2d 2a C
O C
O ISOLATION SIGNAL C
O C
O RHR RHR-V-902(V)
RHR-V-901(V) 2b 2a C
O X-44B X-44B M
L X-44B E
X-44B K
1"PI(1)-4S-X44Bk LOW PRESSURE CONNECTION-TYPICAL OF 10 1"PI(1)-4S-X44Be SEE PENETRATION TABLE X-74f 1"PI(1)-4S-X74f 1"PI(1)-4S-X74e X-74e RO X-74e RO X-74f 3/4" 3/4"PI(1)-4S-X44BL HIGH PRESSURE CONNECTION TYPICAL OF 2 FOR CALIBRATED JET PUMP "10" ONLY 2d 2a C
O 1"
3/4" 3/4" RO RO N-1A N-9A JP-5 3/4"PI(1)-4S-X44Bm RECIRCULATION OUT 24"RRC(2)-4S-1(GE) 3/4"PSR(104)-4S CONT ON M896 (E/15)
RRC-4S RHR-45 20"RRC(6)-4S-1 LPD 05 LPDS PS 18A B35-NO18A C
O ISOLATION SIGNAL 2d 2a C
O 2b 2a 3/4"PI(1)-4S-X78F X-78f RO RRC 1"PI(1)-4S-X74a X-74a DPI 5
B22-R005 MS FROM DWG.
M529 (H/12)
TO MS-FT-34V (MS-JP-10) B22-NO34V TO MS-FT-34T (MS-JP-9) B22-NO34T TO MS-FT-34R (MS-JP-8) B22-NO34R TO MS-FT-34N (MS-JP-7) B22-NO34N TO MS-FT-34L (MS-JP-6) B22-NO34L TO MS-FT-34J (MS-JP-5) B22-NO34J TO MS-FT-34G (MS-JP-4) B22-NO34G TO MS-FT-34E (MS-JP-3) B22-NO34E TO MS-FT-34C (MS-JP-2) B22-NO34C TO MS-FT-34A (MS-JP-1) B22-NO34A DPT 32 B22-NO32 MS C
T TO MS-DPR/FR-613 B22-R613 (K/15)
C O
TO (G/4)
X-75b 1"PI(1)-4S-X75b 2b 2a TO CRD SYSTEM CRD-DPT-8, C12-N008 CONT. ON M528-2 (F/3)
TO HPCS SYSTEM HPCS-DP1S-9, E22-N009 CONT. ON DWG. M520 (J/7)
RO RO RRC-V-19 RRC-V-20 RRC-V-98 SP 1
S 3/4"RRC(13)-4S-1 NE RMS RRC-V-21 RRC-V-22 2c 2a 3/4"RRC(55)-4S-1 A,C SIGNAL C
O T
NE RRC-V-115 RMS C
O T
X-77Aa 3/4" 1"
1" 1/2"RRC-V-96 (V) 1/2"RRC-V-97 (V) 3/4"RRC(55)-4S-6 PROCESS SAMPLING FT 11A B35-NO11A TO RECIRC. LOOP "A" FLOW CONTROLLER ON H13-P634 FT 14B B35-NO14B FT 14A B35-NO14A PSR-4S RRC-4S FT 14C B35-NO14C F/U B
APRM C
F/U A
APRM C
FT 14D B35-NO14D RRC-V-902(D)
RRC-V-901(V)
RRC-V-904(D)
RRC-V-903(V)
FR 614 RRC FROM APRM F/U-53 (F/3)
F/U C
APRM C
F/U D
APRM C
APRM FLOW UNITS 2b 2a C
O C
O C
O PI-V-901 X-61a X-40d C
O PI-V-902 X-40c 1/2" 1"
1" 1/2" RRC-V-99(V)
RRC-V-100(V) 1"PI(1)-4S-X40c 1"PI(1)-4S-X40d RO RO 1"PI(1)-4S-X61b 1"PI(1)-4S-X61a 24"RRC(2)-4S-1(GE)
RO FE 14 RO 215 220 215 220 HIGH PRESSURE CONNECTION PRESSURE ABOVE CORE PLATE RRC-V-59 3/4"RRC(13)-4S-1 SP DO14 12"RRC(1)-4S-5(GE) 12"RRC(1)-4S-7(GE) 12"RRC(1)-4S-9(GE) 12"RRC(1)-4S-11(GE) 12"RRC(1)-4S-13(GE)
N-2A N-2B N-2C N-2D N-2E SEE DWG. M523-1 16"RRC(1)-4S-3(GE) 16"RRC(1)-4S-3(GE)
(F/13) 24"RRC(1)-4S-1(GE) 1"PI(I)-4S-X75b 2"RRC(51)-4-3 RPV INVERT CONTR. 215 CONTR. 2 3"X 2" RED 1"PI(1)-4S 4"RRC(51)-4-3 2"RRC(51)-4-5 4"RWCU(4)-4-1 DWG. M523-1 12"RRC(1)-4S-15(GE)
X-61b T/C JUNCTION BOX TRS 601 B35-R601 AH FROM RCC-TE-9B (B35-N009B)
DWG. M525-1 (F/7)
FROM RCC-TE-1B (B35-N001B)
DWG. M525-1 (F/7)
FROM RCC-TE-803B (B35-N003B)
DWG. M525-1 (F/7)
FROM RECIRC. PUMP "B" TE'S (D/7)
FROM RCC-TE-9A (B35-N009A)
DWG. M525-1 (F/9)
FROM RCC-TE-1A (B35-N001A)
DWG. M525-1 (F/9)
FROM RCC-TE-803A (B35-N003A)
DWG. M525-1 (F/9)
FROM RECIRC. PUMP "A" TE'S (D/12)
PI 602A B35-R602A PT 5A B35-N005A PI 1A B35-R001A PI 603A B35-R603A PT 6A B35-N006A PI 2A B35-R002A FROM E/S B35-K600 C
O C
O 2c 2b 633C B35-K633C RRC-V-27A RRC-V-28A RRC-V-25A RRC-V-26A RRC-1 RRC-4S 2c 2a 3/4"RRC(51)-1 3/4"RRC(51)-4S-5 3/4"RRC(51)-4S-3 MO 23A B35-F023F C
O RMS C
O NOTE 6 EDR-1 RRC-1 TR 650 B35-R650 TT 32C MV/I 640A B35-K640A B35-NO32C T
T 3/4"RRC(51)-1 TO B35-K640B (C/5)
TO RECIRC.
FLOW CONTROL SYSTEM 633A B35-K633A TT 32A B35-NO32A TE 28A B35-NO28A TE 23A B35-NO23A C
C 1"PI(1)-4S-40f RRC-V-101(V)
RRC-V-102(V) 1"PI(1)-4S-X40e X-40e X-40f CRD-4S RRC-4S 1"CRD(13)-4S RRC-V-704 PI 5
RRC-V-618(V)
B35-1"RRC(5)-4S 3/4"RRC(5)-4S (PUMP SEAL PURGE)
RRC-V-8B RO 1B B35-D001B FC 2B B35-D002B FIS 39B B35-NO39B RRC-V-16B RRC-V-86B RRC-V-92 3/4"RRC(55)-4S MO 3/4"RRC(53)-4S 2c 2b T
RRC-V-8A RO 1A B35-D001A FC 2A B35-D002A FIS 39A B35-NO39A RRC-V-16A RMS KEY LOCK C
O RRC-V-86A RRC-V-91 DPI 612A B35-R612A DPT 15A B35-NO15A T
FROM E/S B35-K600 RMS 2c 2a T
C O
3/4"RRC(54)-4S 3/4"RRC(55)-4S X-70f X-70e 2c 2b RRC-V-87A RRC-V-90A 3/4"RRC(55)-4S-5 X-43B 1"RRC(54)-1 3/4"RRC(54)-4S RRC-V-87B RRC-V-90B RRC-V-13A RRC-V-14A RRC-V-88A RRC-V-89A X-43A 3/4"RRC(5)-4S-1 PX 11A RRC-V-705A RWCU-4 RRC-4S RRC-V-51A RRC-V-52A 3/4"RRC(55)-4S-3 TO RWCU SYSTEM 4"RWCU(3)-4-1 SEE DWG. M523-1 (G/13) 2"RRC(51)-1 3/4"RRC(51)-1 RRC-1 RRC-4S 2c 2a 4"RRC(4)-4S-1 RRC-V-13B RRC-V-14B 1"PI(1)-4S-X70f 1"PI(1)-4S-X70e RRC-V-108(V)
RRC-1 EDR-1 4"EDR(47)-1 DWG. M537 (D/5) 3/4"RRC(5)-4S-2 3/4" RRC-V-88B RRC-V-89B RO 3/4"RRC(55)-4S-2 (PUMP SEAL PURGE)
RRC-V-107(V)
RRC-V-67A RRC-V-68A RRC-V-69A 3/4"RRC(51)-4S-1 3/4"RRC(51)-1 MO 67A B35-F067A RMS 12"RRC(7)-4S-1 3/4"RRC(50)-4S-3 RRC-V-70A RRC-V-71A RRC-V-65A RRC-V-66A RRC-V-60A (L.O.)
MECHANICALLY BLOCKED OPEN RRC-V-95A RRC-V-94A 3/4"RRC(50)-4S-9 3/4"RRC(50)-4S-1 EDR-1 RRC-1 RRC-4S 2c 2a SEE NOTE 5 RHR-4S RRC-4S SI 141A B35-K141A SI R672A B35-R672A SC 141A RMS 116A T
SE 1A B35 SE 2A B35 B35-C001A 1A DETAIL "A" 12"RHR(1)-4S-2 FROM RHR PUMPS CONT.
FROM DWG. M521-1 (E/4) 4"EDR(47)-1 CONT. ON DWG.
M537 (D/5) 3/4"RRC(50)-1 3/4"RRC(50)-1 4"EDR(47)-1 CONT. ON DWG.
M537 (D/5) 3/4" 4"RRC(8)-4S-3(GE) 3/4"RRC(50)-1 TE A1, VBS A2 AH RMS P
SEE DETAIL "A"
TE B1,B2 TE C1,C2 TE D1,D2 TE E1,E2 TE F1,F2 TE G1,G2 TE H1,H2 TE J1,J2 TO T/C JUNCTION BOX 4"RRC(4)-4S (D-E/15)
SEAL STAGING RO RO 3/4"RRC(51)-1-1 (SEAL LEAK DETECTION)
LS 3A A
LS 4A A
1" 3/4" 3/4"RRC(5)-4S-1 3/4" RRC-V-78A RRC-V-77A FE 2A FIS 2A AH NOTE 13 RRC-V-1A RRC-V-2A RRC-1 RRC-4S 2C 2b RRC-1 EDR-1 3/4"RRC(51)-4S-7 1"RRC(5)-4S-1 2c 2b FIS 7A AH/L FE 7A RO NOTE 13 RRC-V-75A 3/4"RRC(51)-1 3/4"RRC-V-76A 3/4"RRC(55)-1 4"EDR(47)-1 SEE DWG. M537 (G/5) 3/4"RRC(51)-1 3/4"RRC(60)-43-1 NO.2 SEAL CAVITY NO.1 SEAL CAVITY NOZZLE "H" 1" BEDPLATE DRAIN DWG.
DET "D" ND DC RRC-SPV-85A SEE DET "C" RO PUMP B35-C001A RRC-P-1A 3/4"RRC(5)-4S-2 TE H1,H2 3/4" C 220 C 2 NOTE 2b NOTE 2a PUMP STUFFING BOX C
1"PI(1)-4S-X40e &
1"PI(1)-4S-X41e 3/4" 4"RRC(8)-4S-1(GE) 8"RRC(1)-4S-17(GE)
RRC-V-75A & B RO NOTE 2c NOTE 2a C 215 C 2 C1 RRC-1 RRC-4 DETAIL "C" SEAL STAGING FLUID OUT RRC-V-67B RRC-V-68B RRC-V-69B 3/4"RRC(51)-4S-2 3/4"RRC(51)-1 RRC-1 EDR-1 MO 67B B35-F067B RMS 12"RRC(7)-4S-2 RHR-4S RRC-4S 12"RHR(1)-4S-5 FROM RHR PUMPS CONT. 0N DWG. M521-2 (F/14)
RRC-V-60B (L.O.)
MECHANICALLY BLOCKED OPEN RRC-V-70B RRC-V-71B 3/4"RRC(50)-4S-4 4"EDR(47)-1 CONT. ON DWG.
M537 (D/7)
SI 141B B35-K141B SI R672B B35-R672B SC 141B RMS 116B T
SE 1B B35 SE 2B B35 B35-C001B 1B DETAIL "B" JP-10 JET PUMPS REACTOR VESSEL 2"RRC(51)-4-3 1"PI(1)-4S-X74a EL. 521'-0 1/4" N-15 DRAIN N-11 12"RRC(1)-4S-6(GE) 12"RRC(1)-4S-8(GE) 12"RRC(1)-4S-10(GE) 12"RRC(1)-4S-12(GE) 12"RRC(1)-4S-14(GE)
N-2F N-2G N-2H N-2J N-2K FI 611B B22-R611B MS F
602B B22-K602B MS T
F 607B B22-K607B MS F
601D B22-K601D MS SQRT 600W B22-K600W MS DPI 608W B22-R608W MS C
U=JP-19 W=JP-20 M=JP-16 P=JP-17 S=JP-18 F
601B B22-K601B MS B=JP-11 D=JP-12 F=JP-13 H=JP-14 FT 34W B22-NO34W FI 609D B22-R609D MS SQRT 605D B22-K605D T
FT 34K B22-NO34K C
SQRT 600K B22-K600K MS MS FOR CALIBRATED JET PUMP "15" ONLY 2d 2a C
O C
O e
K LOW PRESSURE CONNECTION-TYPICAL OF 10 X-44A X-44A HIGH PRESSURE CONNECTION TYPICAL OF 2 2d 2a RO RO 3/4" 3/4" RO N-9B JP-15 JP-20 3/4"PI(1)-4S-X44Am 24"RRC(2)-4S-2(GE)
LPD 06 LPDS 1"PI(1)-4S-X75a TO MS-FT-34U (MS-JP-19) B22-NO34U TO MS-FT-34S (MS-JP-18) B22-NO34S TO MS-FT-34P (MS-JP-17) B22-NO34P TO MS-FT-34M (MS-JP-16) B22-NO34M TO MS-FT-34K (MS-JP-15) B22-NO34K TO MS-FT-34H (MS-JP-14) B22-NO34H TO MS-FT-34F (MS-JP-13) B22-NO34F TO MS-FT-34D (MS-JP-12) B22-NO34D (MS-JP-11) B22-N034B TO MS-FT-34B 2d 2a RO 2b 2a X-75f X-75e X-62c RRC-V-110(V) 1"PI(1)-4S-X75f 1"PI(1)-4S-X75e RO RO 1"PI(1)-4S-X62d 1"PI(1)-4S-X62c RO FE 24 RO 215 220 215 220 X-62d RO 3/4"PI(1)-4S-X44AL RECIRCULATION OUT 1"PI(1)-4S-X44Ak 1"PI(1)-4S-X44Ae TO MS-FSUM-608 B22-K608 &
MS-FSUM-606 B22-K606 (K/14)
FROM MS-SQRT-600B, D, F, H B22-K600B, D, F, H FROM MS-SQRT-600M, P, S B22-K600M, P, S FROM MS-SQRT-600U, W B22-K600U, W NOTE 9. TYPICAL FOR CONTAINMENT INSTR. ROOT VALVES NOTE 8. TYPICAL FOR ALL EXCESS FLOW CHECK VALVES JP-20 AS SHOWN (MS-FT-34W)
TYP. FOR JP-16 THRU JP-19 (MS-FT-34M, P, S, U)
JP-15 AS SHOWN (MS-FT-34K)
TYP. FOR JP-11 THRU JP-14 (MS-FT-34B, D, F, H) 16"RRC(1)-4S-4(GE) 16"RRC(1)-4S-4(GE)
PRESSURE BELOW CORE PLATE 1 1/2"SLC(2)-4S-PI 12"RRC(1)-4S-16(GE) 1"PI(1)-4S-X75a RO RRC-V-109(V)
PI-V-903 FT 11B B35-NO11B TO RECIRC. LOOP "B" FLOW CONTROLLER ON H13-P634 FT 24B B35-NO24B FT 24A B35-NO24A FT 24C B35-NO24C F/U 13 APRM C
F/U 53 APRM C
FT 24D B35-N024D F/U 43 APRM C
F/U 23 APRM C
APRM FLOW UNITS 2b 2a C
O C
O C
O RRC-V-911(V)
RRC-V-912(V)
C O
TO RRC-FR-614 (F/14)
RRC-V-906(D)
RRC-V-905(V)
RRC-V-908(D)
RRC-V-907(V)
X-44A T
SQRT 605B B22-K605B FI 609B B22-R609B FT 33B B22-N033B MS MS MS C
O C
O DPI 608K B22-R608K MS MS FT 33D B22-NO33D MS TYPICAL OF 5 FOR CALIBRATED JET PUMP "20" ONLY X-44A L
M 3/4"PSR(103)-4S CONT. ON M896 (F/15)
X-75A LT 44B B22-N044B MS LI 610 B22-R610 T
MS C
O TO CONDENSATE POT AT 200 AZIMUTH-CONT. ON DWG. M529 (H/4)
TYPICAL REFERENCE TO NOTE 2 TO STATE PIPING CLASSIFICATION C
O TO RWCU-FT-37 G33-N037 DWG. M523-1 (G/11)
TO MS-DPT-32 B22-NO32 (G/12)
TO MS-FT-34W (MS-JP-20) B22-NO34W PS 18B B35-N018B ISOLATION SIGNAL X-69e 1"
3/4"PI(1)-45-X69e 24"RRC(1)4S-2(GE)
N-1B NOTES:
1.
ALL ITEMS MARKED
- ARE FURNISHED WITH ASSOCIATED EQUIPMENT.
PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DWG. SHALL BE CLASSIFIED AS FOLLOWS (BREAK POINTS ARE INDICATED ON FLOW DIAGRAM):
- a. PIPING AND VALVES OF SUBSYSTEM RRC (1), (2) AND (7) AND INSTRUMENT AND PROCESS PIPING AND VALVES AS NOTED:
SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP A
- b. INSTRUMENT AND PROCESS PIPING AND VALVES AS NOTED.
SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP B
- c. INSTRUMENT AND PROCESS PIPING AND VALVES AS NOTED SEISMIC CATEGORY II QUALITY CLASS II CODE GROUP D
- d. PUMP SEAL DRAIN LINES AND INSTRUMENT PIPING AS NOTED SEISMIC CATEGORY I QUALITY CLASS I CODE GROUP C HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.
ALL INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE VALVES UNLESS SPECIFICALLY NOTED OTHERWISE.
ALL PIPING SYSTEMS IDENTIFIED BY THE PREFIX "PI" & "PSR" SHALL BE SUPPLIED AND INSTALLED BY CONTRACT #220.
DETAIL SHOWS VALVE STEM LEAK-OFF CONNECTION WITH LEAK DETECTION.
THIS EQUIPMENT IS NORMALLY CONTROLLED FROM THE MAIN CONTROL ROOM. IF THE MAIN CONTROL ROOM MUST BE VACATED, THIS CONTROL POINT MAY BE ISOLATED AND CONTROL TRANSFERRED TO THE REMOTE SHUT-DOWN PANEL C61-P001.
SEE DWG. M530-2 FOR RRC MISCELLANEOUS SYSTEMS.
EXCESS FLOW CHECK VALVES SHALL BE TAGGED AS FOLLOWS:
PI-EFC-X(PENETRATION NO.)
CONTAINMENT INSTRUMENTATION ROOT VALVE SHALL BE TAGGED AS FOLLOWS:
PI-V-X(PENETRATION NO.)
EXCEPT AS NOTED ON M619, INSTRUMENT CONNECTION DIAGRAMS.
ALL INSTRUMENTATION ON THIS DRAWING TO BE IDENTIFIED BY PREFIX "RRC" UNLESS SPECIFICALLY NOTED OTHERWISE.
ALL INSTR. LINES ARE DESIGNATED BY CODE & LINE #
A. EXAMPLE: LINES ORIGINATING INSIDE CONTAINMENT 1/2" PI(1)-4S - X106 CODE DESIGNATION LINE NUMBER B. EXAMPLE: CONTINUATION OF THE ABOVE LINE OUT-SIDE CONTAINMENT IS DESIGNATED AS FOLLOWS, WITH LINE NUMBERS NOT SHOWN.
1/2"PI(1)-ST-X106 - (H22-P021)-
CODE DESIGNATION LINE NUMBER CODE BREAK DEFINITIONS FOR THERMOWELLS ARE SHOWN ON M610, "INSTALLATION OF THERMOWELLS AND SAMPLE PROBES".
INSTRUMENTATION SO NOTED SHALL BE CODE GROUP E.
DELETED.
SEE VENDOR DWG 81999-F-001 (CVI 02B35-15,5)
FOR INTERNALS INFORMATION & FLOW PATHS ON HY-HP-3A & 3B DELETED.
FOR SAMPLE FUNCTION & INSTRUMENTATION ASSOCIATED WITH THE SAMPLE POINTS SEE DWG. SERIES M607 STEAM & LIQUID SAMPLING FLOW DIAGRAMS AND DWG.
SERIES 60A-00 SAMPLE RACKS DETAILS & FLOW DIAGRAMS.
(NOTES CONTINUED ON DWG. M530-2)
ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE (EXCEPT AS NOTED).
ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.
ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
LEGEND 1.
2.
3.
MAIN VALVE RRC-V-60A VALVE SUFFIX G
SUFFIX B-3 ZONE (D/10)
LINE No.
3/4"RRC(50)-4S-5
- FG UNIQUE 3/4"RRC(50)-4S-7 RRC-V-60B H
B-4 (D/8) 3/4"RRC(50)-4S-6 3/4"RRC(50)-4S-8
- TE AND LEAK-OFF THIS ARRANGEMENT.
THE FOLLOWING VALVES ARE PROVIDED WITH JET PUMP TRANSMITTER L.P. SENSING LINE PENETRATION TABLE UNIQUE LINE No.
PUMP No.
INSTR.
PENETR. No.
FT-No.
PI(1)-4S-X44Ba PI(1)-4S-X44Bb PI(1)-4S-X44Bc PI(1)-4S-X44Bd SEE (J/11)
PI(1)-4S-X44Bf PI(1)-4S-X44Bh PI(1)-4S-X44Bg PI(1)-4S-X44Bj SEE (J/11)
PI(1)-4S-X44Aa PI(1)-4S-X44Ab PI(1)-4S-X44Ac PI(1)-4S-X44Ad SEE (J/7)
PI(1)-4S-X44Af PI(1)-4S-X44Ag PI(1)-4S-X44Ah PI(1)-4S-X44Aj SEE (J/7)
MS-JP-1 MS-JP-2 MS-JP-3 MS-JP-4 MS-JP-5 MS-JP-6 MS-JP-8 MS-JP-7 MS-JP-9 MS-JP-10 MS-JP-11 MS-JP-12 MS-JP-13 MS-JP-14 MS-JP-15 MS-JP-16 MS-JP-17 MS-JP-18 MS-JP-19 MS-JP-20 X-44Ba X-44Bb X-44Bc X-44Bd X-44Be X-44Bf X-44Bh X-44Bg X-44Bj X-44Bk X-44Aa X-44Ab X-44Ac X-44Ad X-44Ae X-44Af X-44Ag X-44Ah X-44Aj X-44Ak MS-FT-34A MS-FT-34C MS-FT-34E MS-FT-34G MS-FT-34J MS-FT-34L MS-FT-34R MS-FT-34N MS-FT-34T MS-FT-34V MS-FT-34B MS-FT-34D MS-FT-34F MS-FT-34H MS-FT-34K MS-FT-34M MS-FT-34P MS-FT-34S MS-FT-34U MS-FT-34W MS-FT-33A MS-FT-33C MS-FT-33B MS-FT-33D FT-No.
LD-V-4*
NOTES: CONT. FROM (B/2)
NOTES CONT. AT ZONE (K/4) 4"RRC(8)-4S-2(GE) 24"RRC(1)-4S-2(GE) 8"RRC(1)-4S-18(GE)
VBS P
RMS TE A1,A2 TE B1,B2 TE C1,C2 TE D1,D2 TE E1,E2 TE F1,F2 TE G1,G2 TE H1,H2 TE J1,J2 SEE DETAIL"B" M
(SEAL LEAK DETECTION)
A AH RECIRCULATION PUMP B35-C001B RRC-P-1B RO 1"BEDPLATE DRAIN SEE DWG.
M539 (F/2)
NOZZLE "H" No.2 SEAL CAVITY No.1 SEAL CAVITY 3/4" 3/4"RRC(51)-1-2 (SEAL STAGING) 1"RRC(5)-4S-2 SEE DWG.
E516 (D/9) 20-SSLSVB 3/4" RRC-V-617(D)
RRC-V-612(D) 3/4"RRC(56)-4S-1 PX 11B RRC-V-611(V)
RRC-V-616(V) 3/4"RRC(5)-4S-2 3/4"RRC(60)-4S-2 3/4"RRC(53)-4S-1 24"RRC(2)-4S-2(GE)
MO 23B B35-F023B RMS C
O RRC-V-27B RRC-V-28B 3/4"RRC(51)-4S-4 RRC-V-23B RRC-V-25B RRC-V-26B 4"RRC(8)-4S-4(GE) 3/4"RRC(50)-1 3/4"RRC(51)-1 3/4"RRC(51)-1 3/4"RRC(51)-4S-6 RRC-4S RRC-1 2a 2c 2a 2c 633D B35-K633D 633B B35-K633B TE 28B B35-N028B TT 601B B35-N601B TE 23B B35-N023B RO RO C
C FROM PSCL-B35-K697B DWG.
M529 (K/5) 1"PI(1)-4S-X41e RRC-V-105(V)
RRC-V-106(V)
X-41e X-41f MV/I 640B B35-K640B 3/4"RRC(5)-4S-2 1"PI(1)-4S-X41f 4"RRC(4)-4S-2 2"RRC(51)-4S-10 RRC-4S RWCU-4 RRC-V-51B RRC-V-52B RO RRC-4S RRC-1 2a 2c 2"RRC(51)-1 SEE NOTE 22 RRC-1 EDR-1 3/4"RRC(51)-1 4"EDR(47)-1 CONT. ON DWG. M537 (D/7) 1"PI(1)-4S-X41c 1"PI(1)-4S-X41d 3/4" 3/4" RRC-V-103(V)
RRC-V-104(V)
TO RECIRC. FLOW CONTROL SYSTEM C
O C
O DPT 15B B35-N015B RRC-V-910(V)
DPI 612B B35-R612B RRC-V-909(V)
FROM E/S B35-K600 T
X-41c X-41d C
O RRC-V-913(V)
PI 1B B35-R001B PT 5B B35-N005B PI 602B B35-R602B FROM E/S-B35-K600 C
O RRC-V-914(V)
PI 2B B35-R002B PT 6B B35-N006B PI 603B B35-R603B 2b 2c TT 601D B35-N601D 3/4" RRC-V-78B RRC-V-76B RRC-V-1B RRC-V-2B 3/4"RRC(5)-4S-8 RRC-1 RRC-4S 2c 2b 2c 2b 3/4"RRC-V-77B AH FIS 2B B35-N002B FE 2B 3/4"RRC(55)-1 4"RRC(4)-4S-2 ND DC NOTE 13 RRC-1 EDR-1S RRC-1 EDR-1 1 1/2"RRC(51)-1 3/4"RRC(51)-1 4"EDR(47)-1 CONT. ON DWG. M537 (D/7)
RO RRC-V-75B 24"RRC(2)-4S-2(GE)
DET"C" SEE DET"D" FIS 7B FE 7B NOTE 13 RRC-V-95B RRC-V-94B 3/4"RRC(50)-4S-10 RRC-V-65B RRC-V-66B 3/4"RRC(50)-4S-2 SEE NOTE 5 3/4"X1"RED RRC-4S EDR-1 2a 2c 3/4"RRC(50)-1 EDR-1 RRC-1 MAIN VALVE 2c 2b RRC-1 RRC-4S LD-V-5*
3/4"RRC(50)-4S RMS TRS 608 E31-R608 LD 3/4"RRC(50)-1 (BODY DRAIN) 3/4"RRC(50)-4S 3"
AH 3/4"RRC(51)-1 PRIMARY CONTAINMENT 3/4"RRC(55)-4S-4 C
O MO RRC-4 RRC-1 RRC-RV-15A 1"RRC(54)-1 RRC-V-615(V)
RRC-V-601(V)
RRC-V-614(V)
RRC-V-093(V)
RRC-RV-15B RCC-4S RCC-1 C
O 2"RRC(51)-4S-1 TT 601C B35-N601C TT 601A B35-N601A S
S 3/4"RRC(55)-1 1 1/2"RRC(51)-1 24"RRC(2)-4S-1(GE)
C O
1" S
S S
S S
S 2
1 SEE PENETRATION TABLE S
S S
S 1/2" 1"
M RRC-1 H
L A
S S
B. L. STAFFORD 8-14-00 79 4-19-02 REDRAWN AND REVISED PER 01424-013, 01488-004, 01553-015 4WT/BLS KL DRJ SEE 1"
RRC-V-85B SPV-85B RRC-H L
A RRC-V-85A & B*
RO RO RRC-V-85A MS 3/4"RRC(50)-1 TE 21 G33-NO21 H
L A
RRC-1 EDR-1 MS (F/13)
R005 RECIRCULATION 3/4"x 1"RED 3/4"x 1"RED SEE TE N016 LD FG D001 LD FSAR FIG.
RRC-V-705B REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.
CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.
TT 32D B35-N032D TT 32B B35-N032B 1"
G RRC-V-23A TO B35-R650 RRC-TR-650 (D/12) 4"RWCU(3)-4 TO RWCU SYSTEM CONT. ON DWG. M523-1 (G/13) 4"EDR(47)-1 CONT. ON DWG. M537 (D/7)
TO JUNCTION BOX (E/13)
FOR CONNECTION TO 4"MWR(63)-1S CONT. ON DWG.
M539 (G/3) 4"EDR(47)-1 CONT. ON DWG. M537 (F/7)
RRC-1 EDR-1 4"EDR(47)-1 CONT. ON DWG.
M537 (D/8)
FOR CONNECTION TO 4"MWR(62)-IS CONT. ON DWG.
M539 (G/3) 4"EDR(47)-1 CONT. ON DWG.
M537 (D/7)
RRC-1 RRC-4S 2c 2a RRC-1 RRC-4S 2c 2a 4"EDR(47)-1 CONT. ON DWG.
M537 (D/5)
FOR CONNECTION TO 4"MWR(62)-1S CONT. ON DWG.
M539 (G/4)
CONT. ON DWG. E516 (H/9) 20-SSLSVA 4"EDR(47)-1 CONT. ON DWG. M537 (F/5)
RRC-1 EDR-1 FROM CONTROL ROD DRIVE SYSTEM CONT. FROM M528-2 (D/6)
FOR CONNECTION TO 4"MWR(63)-1S CONT.
ON DWG. M539 (G/4) 4"EDR(47)-1 CONT. ON DWG.
M537 (D/4)
FROM PSCL-B35
-K697A DWG. M529 (J/15) 4"EDR(47)-1 CONT. ON DWG. M537 SEE TABLE FOR ZONE FROM STANDBY LIQUID CONTROL SYSTEM CONT. ON DWG. M522 (F/13) 20"RHR(2)-4 TO RHR PUMPS CONT. ON DWG.
M521-1 (E/4)
FROM COND.
POT AT 20° AZIMUTH CONT. ON DWG. M529 (J/15)
DWG. M523-1 (F/13)
DWG. M523-1 (F/13)
G DEACTIVATED AND SPARED IN PLACE 80 6-27-03 REVISED PER 01288-330 (H/8-9)
CMO KB DRJ