Drawing M526-1, Rev 93, Flow Diagram Fuel Pool Cooling and Clean-up System
ML053270126
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 05/03/2002
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M526-1, Rev 93
Download: ML053270126 (1)


Text

2 1

3 15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 4

5 6

7 8

9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3

1 2

A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE NORTHWEST CHECKED SCALE DRAWN DWG NO.

REV.

FLOW DIAGRAM FUEL POOL COOLING AND CLEAN-UP SYSTEM M526-1 93 NONE N. THEISEN 01-11-01 H. LE 04-04-02 D.R. JACOBSEN 5-3-02 SERVER84\\00\\DWG REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

FSAR FIG.

NOTES:

LEGEND:

1. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES)

SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE, EXCEPT AS NOTED.

2. ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES)

SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.

3. ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.
1. ALL EQUIPMENT, VALVES, SPECIALTIES, AND INSTRUMENTATION UPSTREAM OF CHEMICAL WASTE AND WASTE SLUDGE PHASE SEPARATOR TANKS AND DOWNSTREAM OF RADWASTE BUILDING PENETRATION SHALL BE FURNISHED UNDER CONTRACT E-2808-20 WITHIN LIMITS SHOWN.
2. ALL PRESSURE, SAMPLING, AND/OR FLOW INSTRUMENT ROOT VALVES NOT LABELED WILL BE 3/4" GLOBE VALVES, UNLESS SPECIFICALLY NOTED OTHERWISE.
3. ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS ON THIS DRAWING, EXCEPT AS NOTED IN OTHER NOTES, SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II SEISMIC CATEGORY II CODE GROUP C

4. ALL PIPING ON THIS DRAWING IN THE REACTOR BUILDING AND RADWASTE BUILDING CORRIDOR, EXCEPT AS NOTED IN FOLLOWING NOTES, SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II SEISMIC CATEGORY II Å CODE GROUP C

Å HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.

5. ALL PIPING REFERRING TO THIS NOTE SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP B

6. (DELETED)
7. PIPING, VALVES, & COMPONENTS SHOWN ON THIS DRAWING IN THE CPR(29)-1, MWR(38)-1, MWR(40)-1, CF(ALL), SA(1)-1, COND(ALL)

SYSTEM SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II SEISMIC CATEGORY II CODE GROUP D HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.

8. ALL INSTRUMENTATION, PIPING, AND TUBING DOWNSTREAM OF THE INSTRUMENT ROOT VALVE SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II SEISMIC CATEGORY II CODE GROUP D EXCEPT AS NOTED ON M619, INSTRUMENT CONN. DIAGRAMS

9. ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS REFERRING TO THIS NOTE SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP C

10. PIPING, VALVES, & ASSOCIATED COMPONENTS ON THIS DRAWING SHALL BE CLASSIFIED AS FOLLOWS: (BREAK POINTS ARE INDICATED ON THIS DIAGRAM)

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP D *

  • STRAINERS SHALL HAVE ALL FABRICATION & MATERIALS TO APPLICABLE REQUIREMENTS OF ASME III-2, EXCEPT CODE STAMP IS NOT REQUIRED &

PERFORATED PLATE MAY BE ASTM MATERIAL & COMPLIANCE WITH NA-3700 IS NOT MANDATORY. FURNISHED & INSTALLED BY CONTR. 213A

11. ALL PIPING FOR FPC(9)-1 UPSTREAM OF FPC-V-169, FPC(10)-1, FPC(11)-1, & FPC(52)-1 SHALL HAVE ALL WELDS EXAMINED BY LIQUID PENETRANT EXAMINATION, AND SHALL HAVE ALL FABRICATION AND MATERIALS TO APPLICABLE REQUIREMENTS OF ASME III-3, EXCEPT CODE STAMP IS NOT REQUIRED.

QUALITY CLASS II SEISMIC CATEGORY II CODE GROUP D HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.

12. DIFFUSERS SHALL BE CLASSIFIED AS STATED IN NOTE 4 FOR MATERIAL FABRICATION AND INSTALLATION ONLY. CODE STAMP NOT REQUIRED.
13. ALL PIPING, VALVES, & ASSOCIATED COMPONENTS REFERRED TO BY THIS NOTE, IF PURCHASED OR INSTALLED PRIOR TO 1 JAN. 1980, SHALL BE:

QUALITY CLASS II SEISMIC CATEGORY I CODE GROUP C AND, IF PURCHASED OR INSTALLED AFTER 1 JAN. 1980, SHALL BE:

QUALITY CLASS I SEISMIC CATEGORY I CODE GROUP C

14. ALL PIPING DOWNSTREAM OF THE LAST ISOLATION VALVE AND OPEN TO THE ATMOSPHERE WITH THE SUBSYSTEM DESIGNATION "SYSTEM" (50)

THRU (59) SHALL BE CLASSIFIED AS CODE GROUP "D" WITH QUALITY CLASS AND SEISMIC CATEGORY PROVIDED BY THE APPLICABLE NOTES ON THIS DRAWING, EXCEPT WHERE THE APPLICABLE NOTES CALL FOR QUALITY CLASS II+, PIPING SHALL BE QUALITY CLASS II.

15. ALL PIPING, VALVES, AND ASSOCIATED COMPONENTS REFERRED TO BY THIS NOTE SHALL BE CLASSIFIED AS FOLLOWS:

QUALITY CLASS II+

SEISMIC CATEGORY II CODE GROUP D+

HANGERS TO BE DESIGNED TO SEISMIC CATEGORY I LOADS.

+ SEE NOTE 12, WNP-2 SPEC, SECT. 15B.1, TABLE 2 NOTES.

16. VALVE IS NOT ASME III CLASS 3, IT IS CONSIDERED SA105 MATERIAL WELDED TO THE SYSTEM. THE FOLLOWING WASHINGTON STATE SPECIAL NUMBERS ARE IDENTIFIED WITH CORRESPONDING VALVES.

VALVE TAG NO.

WASHINGTON STATE SPECIAL NUMBER FPC-V-172 WS-17-83W FPC-V-173 WS-18-83W FPC-V-175 WS-19-83W FPC-V-181A WS-20-83W FPC-V-181B WS-26-83W FPC-V-184 WS-21-83W

17. FPC-V-145A AND FPC-V-145B INTERNALS HAVE BEEN REMOVED.
18. DWG. M837 CONTAINS INFORMATION ON THE INNER DRYWELL BELLOWS AND ASSOCIATED DRAINS.
19. FPC-PS-16A AND FPC-PS-16B ARE DEACTIVATED IN PLACE.

DPIC 1

FPC FPC-V-902(V)

FPC-V-901(V)

DETAIL-1 (B/7)

DETAIL-2 DETAIL-3 FPC-P-1B VENTS

& DRAINS SEE ZONE (C/12-13)

FPC-P-1A VENTS

& DRAINS SEE ZONE (D/12-13)

FPC-V-187B(V)

FPC-V-150B(D)

FPC-V-186(D)

(BEDPLATE DRAIN) 3/4"FPC(50)-1-7 3/4"FPC(50)-1 1/2" 1/2"FPC(51)-1S-1 FPC-V-187A(V)

FPC-V-150A(D)

FPC-V-185(D)

(BEDPLATE DRAIN) 3/4"FPC(50)-1-6 3/4"FPC(50)-1 1/2" 1/2"FPC(51)-1S-1 FPC-1S FPC-1 1/2"FPC(51)-1-1 WATER LEVEL SUPPRESSION POOL REACTOR PEDESTAL 6"x4"RED 4"FPC(34)-1-1 FABRICATED BY 215

& INSTALLED BY 213A EXCEPT AS INDICATED IN M702 SEC. 73-73 DEBRIS SCREEN SKIMMER SURGE TANK FPC-TK-1B DEBRIS SCREEN 6"FPC(13)-1-1 REACTOR WELL DRAIN 4"FPC(10)-1-1 4"FPC(10)-1-2 4"FPC(10)-1-3 2"FPC(11)-1-1 2"FPC(12)-1-2 2"FPC(12)-1-3 2"FPC(12)-1-4 2"FPC(11)-1-2 4"FPC(10)-1-4 4"FPC(10)-1-5 4"FPC(10)-1-6 6"FPC(13)-1-2 6"FPC(13)-1-3 10"FPC(9)-1-1 LINER DRAIN SEAL RUPTURE DRAINS FPC-V-101 FPC-V-102 FPC-V-131 NOTE 4, CONTR. 206 NOTE 11, CONTR. 215 8"FPC(13)-1-1 DRYWELL TO REACTOR WELL SEAL DRAINS REACTOR WELL DRAIN 4"FPC(13)-1-1 2"FPC(12)-1-1 6"FPC(13)-1-2 6"FPC(13)-1-3 FPC-V-107 FPC-V-106 4"FPC(16)-1-1 FPC-V-104 FPC-V-103 3/4"FPC(55)-1-9 FPC-V-705 LI 19 FPC FPC-V-904(V) 3/4"FPC(60)-1-1 2"FPC(50)-1-3 2"FPC(50)-1 DRYER SEPARATOR POOL DRAIN VALVE.

CONTR 206 CONTR 215 REACTOR WELL DRAIN VALVE NOTE 13 NOTE 13 FPC-1 FPC-1S FPC-1 EDR FPC-V-735A 3"EDR 3"EDR COND-V-42 COND-V-68 3"COND(78)-1 CONT FROM DWG. M527-1 (J/6)

F.C.

O C

RMS AO 42 COND 4"

COND-SPV-42 3/4"FPC (50)-1-8 EDR FPC-V-752(D) 1/2" SS TUBING NOTE 4 NOTE 7 FPC-V-701A FPC-V-702A FPC-V-703A FPC-V-704A LIS 1A FPC LIS 2A FPC LIS 3A1 FPC LIS 3A2 FPC AHH ALL 4"

FPC-V-735B 3/4"FPC (50)-1-9 EDR FPC-V-753(D) 1/2" SS TUBING FPC-V-701B FPC-V-702B FPC-V-703B FPC-V-704B LIS 1B FPC LIS 2B FPC LIS 3B1 FPC LIS 3B2 FPC AHH (EMBEDDED WEIR PIPE)

(EMBEDDED WEIR PIPE) 4"FPC(18)-1-1~GRAVITY FLOW 4"FPC(18)-1-2~GRAVITY FLOW CONTRACT 206 CONTRACT 206 CONTRACT 206 CONTRACT 206 TRANSITION PIECE CONTRACT 206 TRANSITION PIECE CONTRACT 206 RADWASTE BUILDING REACTOR BUILDING NOTE 4 NOTE 3 RADWASTE BLDG. CORRIDOR FPC-V-108 EDR 2"FPC(50)-1-4 2"FPC(50)-1 FPC-V-130 FUEL POOL RECIRCULATION SKIMMER SURGE TANKS OUTLET VALVE 10"FPC(1)-1-2 10"FPC(15)-2-1 TE 4

FPC TO RHR-TRS-601 DWG. M521-1 (J/9)

FPC-V-610(D) 20"RHR(2)-2-2 CONT. ON DWG.

M521-1 (C/9) 10"FPC(5)-2-1 10"RHR(15)-2-2 CONT. FROM DWG.

M521-2 (H/11)

FPC-V-181A MO RMS RMS 1A1 FPC FPC-V-181B MO RMS RMS 1B1 FPC FPC-V-121 FPC-V-611(V) 3/4"FPC(53)-2-1 3/4" RO 5A FPC RO 5B FPC REMOVABLE SPOOL PIECE 10"FPC(5)-2-1 FPC-V-616(D) 3/4"FPC(52)-2-4 FPC-V-612(D)

FPC-V-119 L.C.

FPC-V-120 FPC-2 FPC-1S FPC-2 RHR-2 FPC-V-706A PS 6A FPC PI 6AG FPC FPC-V-707A PX 7A FPC FPC-V-708A PX 7B FPC FPC-V-112A FPC-V-116A FPC-V-709A PS 9A FPC PI 9AG FPC AL 4"

3" 6"

6"FPC(2)-1-1 SEE DETAIL-3 ZONE (J/4)

FPC-V-706B PS 6B FPC PI 6BG FPC FPC-V-707B FPC-V-708B PX 8B FPC FPC-V-112B FPC-V-709B PS 9B FPC PI 9BG FPC AL 4"

3" 6"

6"FPC(2)-1-2 SEE DETAIL-2 ZONE (H/4) 10"FPC(1)-1-1 FPC-V-905(V)

FPC-V-903(V)

FPC-V-114 6"FPC(19)-1-1 FPC-V-115A FPC-V-603(V)

WATER LEVEL WATER LEVEL CONTR. 215 CONTR. 206 CONTR. 215 CONTR. 215 10"FPC(3)-1S-1 FPC-V-747 FPC-V-746 FPC-V-742 FPC-V-743 3/4"FPC(60)-1S-19 3/4"FPC(60)-1S-41 3/4"FPC(60)-1S-17 3/4"FPC(60)-1S-18 FT 17 FPC FT 16 FPC SQRT 17 FPC FI 17 FPC FE 16 FPC SQRT 16 FPC FI 16 FPC 1/2"PI(1)-1S-(IR-71)-20 1/2"PI(1)-1S(IR-71)-19 TE 6

FPC TI 6

FPC C

CONTR 206 CONTR 215 CONTR 206 CONTR 215 FPC-V-169 10"FPC(9)-1 TO WASTE SURGE TANK DWG. M532 (E/9)

NOTE 15 NOTE 11 1"FPC(50)-1 FPC-V-158 FPC-V-609(D)

FIS 21 FPC EDR FPC-V-110 FPC-V-608(D)

FIS 20 FPC EDR AH 4"FPC(4)-1S-1 4"FPC(4)-1S-2 FPC-V-141 FPC-V-614(D)

FUT. CONN.

SUPPLEMENTARY COOLING & FILLING SUPPLEMENTARY COOLING & FILLING FPC-V-115B FPC-V-710B PX 10B FPC TX 10B FPC FPC-RV-117B FPC-V-151B FPC-V-711B PX 11B FPC TX 11B FPC FPC-V-118B EDR FPC-V-152B 10"FPC(3)-1S-4 6"CPR(29)-1 6"CPR(29)-1 CONT ON DWG.

M534 (A/4) 6"CPR(28)-1 CONT FROM DWG.

M523-1 (B/10) 6"FPC(2)-1-3 6"FPC(2)-1-4 6"FPC(2)-1-3 TE 5B FPC TE 5A FPC FPC-V-602(V)

TO RHR-TRS-601 DWG. M521-1 (J/9)

FPC-V-124 FPC-V-172 FPC-V-173 8"FPC(2)-1-5 CONT. ON DWG. M526-2 (C/15)

MO RMS TO FPC-LS-4A/B ZONE (H/9)

MO RMS FPC-V-740 DPIC 1

FPC FPC-V-184 MO RMS 8"FPC(3)-1-3 CONT. FROM DWG. M526-2 (C/15)

FPC-V-177 TEST CONN.

TEST CONN.

RO 6

FPC FPC-V-140 FPC-V-175 MO RMS FPC-V-147 FPC-V-165 FPC-FCV-1 FPC-V-159 8"FPC(35)-1-2 FO FPC-SPV-1 DPIS 12 FPC DPIS 11 FPC A

O C

A RMS SEE DETAIL-1 ZONE (G/3)

A O

C FPC-V-178 3/4"FPC(55)-1-10 AO 113 FPC O

C 3/8"PI(1)-1-(IR-69)-1 FPC-SPV-113 RMS FPC-V-176 TEST CONN.

NOTE 4 NOTE 13 SHIELDED AREA FOR FUEL POOL HEAT EXCH. & CIRC. PUMPS 6"FPC(4)-1S-1 FPC-V-143 REACTOR WELL RECIRCULATION VALVE FPC-1S FPC-1 6"FPC(4)-1-1 FPC-V-149 FPC-V-182 3/4"FPC(55)-1-8 NOTE 5 NOTE 13 MO 149 FPC RMS O

C ISO SIGNALS F, A FPC-V-730 SP 69 S

FPC-V-127 2"FPC(25)-1-1 FPC-1 FPC-1S FPC-V-123 FPC-V-122 FPC-V-180 TEST CONN.

3/4"FPC(55)-1-7 6"FPC(8)-1-2 3"

4" RMS FPC-V-720 PI 17 FPC 3/4"FPC(60)-1-16 3/8" FPC-ST-12 (SEPARATOR) 6"FPC(7)-1-1 FPC-V-156 MO 156 FPC O

C RMS ISOL. SIGNALS FPC-V-160 X-101 X-100 6"

STRAINERS FPC-V-719 PX 17B FPC FPC-V-718 PX 17A FPC FPC-V-153 MO 153 FPC RMS O

C FPC-V-154 MO 154 FPC RMS FPC-V-155 ISOL. SIGNALS F, A 6"FPC(8)-1-1 FPC-V-601(V)

FPC-V-606(V)

CONTR. 215 CONTR. 213 DRYER SEPARATOR REACTOR WELL DRYWELL REACTOR DRYWELL BELLOWS SEAL SEE NOTE 18 DRYWELL BELLOWS SEAL SEE NOTE 18 4"FPC(16)-1-1 DRYER-SEPARATOR POOL DRAIN SUMP PIT CASK STORAGE FDR LINER DRAIN 3"FDR-1 DWG. M539 (H/6)

OVERFLOW WEIRS 2"

2" 2"

2" 2"

2" FPC-V-146B FPC-V-145B FPC-V-146A FPC-V-145A 8"FPC(3)-1S-3 8"FPC(3)-1S-1 SCUPPER DRAINS SCUPPER DRAINS FPC-V-157B 1/2"FPC(53)-1S-9 FPC-V-157A 1/2"FPC(53)-1S-8 TE 7

FPC TE 8

FPC TS 7

FPC MV/I 7

FPC MV/I 8

FPC TI 7

FPC C

ALH ALH AH AH TI 8

FPC TS 8

FPC FUEL POOL TO FPC-V-172

& FPC-V-184 ZONE (B/5) 10"FPC(3)-1S-1 FIC 21 FPC A

FPC-V-748 FPC-V-749 FPC-V-750 FPC-V-751 LT 21 FPC LI 21 FPC CONTR 215 CONTR 206 2"FPC(52)-1-1 EDR 3"EDR-1 DWG. M537 (J/12)

CONTR 215 CONTR 206 DIFFUSER FUEL POOL GATES 4"FPC(4)-1S-1 4"FPC(4)-1S-2 CONTR. 215 CONTR. 206 CONTR 215 CONTR 206 TO FPC-V-173

& FPC-V-184 ZONE (B/4)

C C

C WATER LEVEL 3"FPC(14)-1-1 1"FPC(50)-1-5 8"FPC(1)-1-3 3/4"FPC(60)-1-11 6"FPC(17)-1-2 3/4"FPC(54)-1 8"FPC(1)-1-5 NOTE 13 RADWASTE BUILDING REACTOR BUILDING NOTE 13 A

NOTE 13 FPC-2 RHR-2 LC FPC-ST-13A FPC-ST-13B FPC-V-113 RMS 1B2 FPC RMS 1A2 FPC FPC-V-105 NOTE 13 LS 5A/B FPC LS 4A/B FPC NOTE 12 SKIMMER SURGE TANK FPC-TK-1A LE 5

FPC LE 4

FPC OVERFLOW WEIRS PX 8A FPC 10"FPC(1)-1-1 8"FPC(13)-1-4 3/4"FPC(55)-1-11 6"FPC(17)-1-1 93 5-3-02 REDRAWN AND REVISED PER 01485-014, 01553-011, & 01486-015 NT HL DRJ O

C NOTE 5 10"FPC(9)-1~GRAVITY FLOW 10"FPC(3)-1S-1 3/4"FPC(55)-1-4 NOTE 16 DEMINERALIZER NOTE 16 DEMINERALIZER NOTE 16 NOTE 9 FPC-V-142(TH)

FUEL STORAGE POOL RECIRCULATION VALVE NOTE 13 FPC-1 NOTE 9 FPC-1S 8"FPC(3)-1-1 4"FPC(58)-1S-1 3/4"FPC(58)-1S-1 2"FPC(25)-1S-1 POOL NOTE 11 CONTR 215 NOTE 4 CONTR 206 2"FPC(52)-1-5 SUPPRESSION POOL CLEAN-UP PUMP FPC-P-3 3/4"FPC(60)-1-15 3/4"FPC(60)-1-14 3/4"FPC(55)-1-6 FPC-V-163 3/4"FPC(55)-1-5 FPC-V-162 F, A 3/4"FPC(55)-1-2 NOTE 10 NOTE 5 NOTE 10 8"FPC(35)-1-1 (NOTE 16) 8"FPC(35)-1-2 3/4"FPC(60)-1-42 6"FPC(7)-1-1 3/4"FPC(60)-1-20 3/4"FPC(55)1-1 REACTOR BLDG NOTE 4 RADWASTE BLDG 2"FPC(52)-1-4 LINER DRAIN 2"FPC(52)-1-3 LINER DRAIN LINER DRAIN 2"FPC(52)-1-1 NOTE 11 NOTE 4 CONTR. 215 CONTR. 206 NOTE 17 NOTE 17 CONTR. 206 CONTR. 215 DIFFUSER T

T T

T T

1" ALL 1"

CONTR. 220 CONTR. 215 CONTR. 206 8"FPC(2)-1-5 FPC-2 NOTE 9 FPC-1 NOTE 13 3/4"FPC(53)-2-2 REMOVABLE SPOOL NOTE 9 8"FPC(15)-2-2 3/4"FPC(52)-2-3 FPC-1 FPC-1S CPR-1 NOTE 7 RADWASTE BLDG.

CORRIDOR REACTOR BLDG.

NOTE 4 NOTE 4 RADWASTE BLDG.

NOTE 3 FUEL POOL CIRCULATION PUMP FPC-P-1A FUEL POOL CIRCULATION PUMP FPC-P-1B 3/4"FPC(60)-1-13 6"FPC(2)-1-4 FUEL POOL HEAT EXCHANGER FPC-HX-1B 3/4"FPC(53)-1-1 1"

3/4"FPC(51)-1 3/4"FPC(50)-1 3/4"FPC(50)-1-2 1"

3/4"FPC(51)-1-2 1"FPC(54)1-2 3/4"FPC(60)-1-8 3/4"FPC(60)-1-9 3/4"FPC(60) 10 1/2"PI(1)-1

-(IR-69)-8 FPC-V-710A PX 10A FPC TX 10A FPC FPC-RV-117A FPC-V-151A FPC-V-711A PX 11A FPC TX 11A FPC FPC-V-118A EDR FPC-V-152A 3/4"FPC(60)-1-6 3/4"FPC(54)-1 3/4"FPC(60)-1-12 6"FPC(2)-1-3 FUEL POOL HEAT EXCHANGER FPC-HX-1A 1"

3/4"FPC(51)-1 3/4"FPC(50)-1 3/4"FPC(50)-1-1 1"

3/4"FPC(51)-1-1 3/4"FPC(54)-1-1 3/4"FPC(60)-1-5 1/2"PI(1)-1(IR-71)-5 3/4"FPC(53)-1-6 TO FPC-LS-5A/B ZONE (H/10)

NOTE 13 NOTE 13 FPC-V-741 FPC-V-179 3/4"FPC(60)-1-7 NOTE 16 1/2"PI(1)-1-(IR-69)-10 1/2"PI(1)-1-(IR-71)-4 3/4"FPC(60)-1-2 NOTE 16 3/4"FPC(60)-1-3 3/4"FPC(60)-1-4 3"FPC(14)-1-1 (GATE DRAIN)

FPC-V-613(D) 3/4"FPC(52)-2-1 10"FPC(1)-1-4 NOTE 13 CONTR. 220 CONTR. 215 CONTR. 206 NOTE 12 2"FPC(52)-1-2 LINER DRAIN NOTE 12 6"

6" 6"FPC(6)-1-1 EFFLUENT INFLUENT 3/4"FPC(53)-1-7 FPC-V-161 3/4"FPC(55)-1-3 FPC-V-116B CONT. ON DWG M524-1 (A/12)

NOTE 13 1/2" NOTE 13 1/2"