Drawing M521-4, Rev 0, Flow Diagram Residual Heat Removal System Deactivated Steam Condensing Mode
ML053270111
Person / Time
Site: Columbia 
Issue date: 04/29/2002
From:
Energy Northwest
To:
Office of Nuclear Reactor Regulation
References
M521-4, Rev 0
Download: ML053270111 (1)


Text

2 1

3 15 14 13 12 11 10 9

8 7

6 5

4 F

E D

C B

F E

D C

B K

J H

G K

J H

G 13 14 15 A

PDS2-E1 4

5 6

7 8

9 10 11 12 DWN CHK APVD DESCRIPTION DATE REV 3

1 2

A APPROVED COLUMBIA GENERATING STATION TITLE DATE SIGNATURE NORTHWEST CHECKED SCALE DRAWN DWG NO.

REV.

FLOW DIAGRAM RESIDUAL HEAT REMOVAL SYSTEM DEACTIVATED STEAM CONDENSING MODE M521-4 0

NTS B. L. STAFFORD 10-9-01 H. LE 1-23-02 D. R. JACOBSEN 4-29-02 SERVER84\\00\\dwg 0

4-29-02 NEW DRAWING PER 01476-011.

BLS HL DRJ NOTES:

SEE M521-1 FOR NOTES ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES AND AS NOTED ON DIAGRAM) SUFFIXED WITH A (V) DENOTE A 3/4" VENT VALVE.

ALL VALVES (EXCEPT THOSE ON INSTRUMENT LINES) SUFFIXED WITH A (D) DENOTE A 3/4" DRAIN VALVE.

ALL VALVES SUFFIXED WITH A (TH) DENOTE A THROTTLED VALVE.

LEGEND:

1.

2.

3.

CONT. ON DWG.

M519 (J/14) 8"RCIC(12)-4-3 8"RHR(20)-4-3 RMS RHR-V-52A MO 52A O

C RCIC-4 RHR-4 L.C.+

RMS RHR-V-87A L.C.+

MO 87A O

C 8"RHR(20)-4-1 E12-F087 E12-F052 RHR-4 RHR-2 14"RHR(20)-2-1 14"RHR(54)-2-1 14"RHR(20)-2-1 8"RHR(20)-2-3 RHR-PCV-51A RHR-2 RHR-4 RHR-SPV-51A RMS 3/8"PI(1)-ST-(IR-71)-2 I/P 3A PC 606A T

T RHR-V-905(V)

PT 26A E12-R606 E12-K003 E12-N026 1/2"PI(1)-ST-(H22-PO18)-A5 A

E12-F051 PCV 51A RHR-V-715A 18"RHR(20)-2-1 3/4"RHR(60)-2-43 RHR-V-122A RHR-V-608(V) 3/4"RHR(52)-2-9 3/4"RHR(60)-2-13 RHR-V-710A RHR-V-711A LT 8A T

LIC 604A T

SEALING POT (TYP.)

3/4"RHR(60)-2-15 RHR-LCV-65A 2 "

2 "

4"RHR(16)-2-1 RHR-SPV-65A RHR SYSTEM INTERLOCK 3/8"PI(1)-ST-(IR-71)-1 4"RHR(16)-2-1 I/P 1A E12-K001 CAPILLARY (TYP.)

LAS 605A E12-K605 E12-N008 E12-R604 4"RHR(16)-2-1 8"RHR(54)-1-1 RHR-V-150A TEST CONN.

3/4"RHR(55)-2-43 4"RHR(18)-2-1 RHR-V-54A E12-F054 6"

4"RHR(16)-1-1 TO RHR-LAS-605B ZONE (H/7)

T E12-R605 T

PT 28 E12-N028 PC 605 RHR-V-26A E12-F026 L.C.+

RHR-V-908(V)

CONDENSING MODE SUPPLY 6"RCIC(11)-1-1 CONT. ON DWG. M519 (E/14) 6"RHR(16)-1-2 RCIC-1 RHR-1 1/2"PI(1)-ST-(H22-P021)-B1 3/4"RHR(60)-1-1 L.C.+

MO 11A E12-F011 T

RMS MO 26A RMS O

C 16"RHR(54)-2-1 RHR-V-224 6"RHR(54)-2-5 3/4"RHR(60)-2-35 3/4"RHR(60)-2-37 DRAIN POT 8"RHR(54)-2-13 RHR-V-718A LS 11C H

RHR-V-225 RHR-V-719A 3/4"RHR(60)-2-41 3/4"RHR(60)-2-39 1 1/2"RHR(54)-2-13 RHR-V-722A LS 11D L

RHR-V-227 RHR-V-723A RHR-V-226 6"RHR(54)-2-3 3/4"RHR(60)-2-29 RHR-V-72OA LS 11B L

RHR-V-721A RHR-V-222 3/4"RHR(60)-2-21 "x "RED. (TYP. 8 PLCS.)

RHR-V-220 4"RHR(16)-1-2 STRUCTURAL CONNECTION 6"RHR(15)-1-1 C.G. B CL. NF 6"RHR(16)-1-3 C.G. B CL. NF RHR-1 RHR-2 RHR-TPSA-1 3/4"RHR(60)-2-31 RHR-V-223 3/4"RHR(60)-2-33 RHR-V-716A LS 11A H

RHR-V-717A RHR-V-221 1"x "RED.

(TYP. 8 PLCS.)

RHR-V-124B RHR-2 RHR-1 O

C L.C.+

T MO 124B RMS RHR-V-170 1 1/2"RHR(54)-2-15 3/4"RHR(55)-2-27 RHR-V-138 RHR-V-183(D)

RHR-V-623(V)

TEST CONN.

3/4"RHR(55)-2-28 3/4"RHR(53)-2-12 MO 124A RHR-V-124A RHR-1 RHR-2 L.C.+

O C

RMS T

L.O.

SEE NOTE 19 REFERENCES TO CONTRACT NUMBERS, SUCH AS 215, 206, 220, FOUND IN THE NOTES ON THIS DRAWING REFER TO ORIGINAL CONSTRUCTION DESIGN REQUIREMENTS.

CURRENT DESIGN REQUIREMENTS ARE DOCUMENTED IN THE STATION DESIGN SPECIFICATIONS AND ACTIVE CONTRACT SPECIFICATIONS WHICH STILL APPLY.

RHR-V-727 CONT. ON DWG.

M521-1 (J/13)

RHR-V-11A 4"RHR(18)-1-1 CONT. ON DWG.

M521-1 (E/11) 18"RHR(1)-2-2 CONT. FROM DWG.

M521-1 (G/11)

CONT. ON DWG.

M521-1 (D/12)

CONT. ON DWG.

M521-1 (D/12)

CONT. ON DWG.

M521-1 (C/13)

CONT. ON DWG.

M521-1 (C/13)

CONT. ON DWG.

M521-1 (D/9)

O C

(REF.)

RHR-V-125A MO 125A RMS LS 10A H

RHR-V-717B RHR-V-213 RHR-V-716B RHR-V-212 LS 10B L

RHR-V-721B RHR-V-720B RHR-V-214 RHR-V-215 L.C.+

3/4"RHR(60)-2-44 3/4"RHR(60)-2-46 3/4"RHR(60)-2-50 3/4"RHR(60)-2-48 RHR-V-613(V)

T O

C 3/4"RHR(53)-2-10 RHR-V-171 L.C.

RHR-V-125B MO 125B RMS L.C.+

T O

C RHR-V-140 3/4"RHR(55)-2-42 TEST CONN.

1 1/2"RHR(54)-2-12 1 1/2"RHR(54)-2-10 LS 10D L

RHR-V-723B RHR-V-219 RHR-V-722B RHR-V-218 LS 10C H

RHR-V-719B RHR-V-718B RHR-V-216 RHR-V-217 3/4"RHR(60)-2-38 3/4"RHR(60)-2-36 3/4"RHR(60)-2-40 3/4"RHR(60)-2-42 DRAIN POT 8"RHR(54)-2-10 RHR-V-617(V) 3/4"RHR(52)-2-8 RHR-V-715B PT 26B PC 606B T

I/P 3B E12-K003 T

RHR-2 RHR-4 RHR-SPV-51B RMS PCV 51B E12-F051 3/4"RHR(50)-2-34 18"RHR(20)-2-2 14"RHR(20)-2-2 14"RHR(54)-2-2 14"RHR(20)-2-2 RHR-V-87B MO 87B RMS L.C.+

8"RHR(20)-2-4 8"RHR(20)-4-4 8"RHR(20)-4-2 RHR-V-52B RCIC-4 RHR-4 MO 52B RMS L.C.+

E12-F087 E12-F052 NOTE 7 O

C 3/8"PI(1)-ST-(IR-69)-7 10"RHR(28)-1-16 6"RHR(52)-2-4 6"RHR(54)-2-6 16"RHR(54)-2-2 10"RHR(28)-1-2 STRUCTURAL CONNECTION LAS 605B LIC 604B T

3/8"PI(1)-ST-(IR-69)-2 SEALING POT RHR-V-711B 3/4"RHR(60)-2-14 3/4"RHR(60)-2-12 RHR-V-710B LT 8B I/P 1B RHR-SPV-65B 4"RHR(16)-2-2 2 1/2" 2 1/2" INTERLOCK RHR SYSTEM TO RHR-PC-605 ZONE (G/14)

RHR-V-54B RHR-V-26B L.C.+

MO 26B 4"RHR(16)-2-2 RHR-V-150B 3/4"RHR(55)-2-49 TEST CONN.

L.C.+

4"RHR(18)-2-2 14"RHR(54)-2-2 RHR-2 RHR-1 SEE NOTE 19 4"RHR(18)-2-2 E12-F054 1/2"PI(1)-ST-(H22-P021)-A5 CAPILLARY (TYP)

T RHR-1 RHR-2 RHR-V-122B E12-F011 8"RCIC(12)-4-2 DWG. M519 (J/14)

RHR-PCV-51B E12-R606 E12-N026 E12-F026 E12-R604 E12-K605 E12-K001 RHR-LCV-65B RHR-2 RHR-1 CONT. ON DWG.

M521-2 (J/4) 4"RHR(18)-1-2 CONT. ON DWG.

M521-2 (C/11) 18"RHR(1)-2-5 CONT. FROM DWG.

M521-2 (G/8)

CONT. ON DWG.

M521-2 (F/3)

CONT. ON DWG.

M521-2 (F/3)

CONT. ON DWG.

M521-2 (D/3,4)

(REF.)

4"RHR(16)-1-2 MO 11B 1 1/2"RHR(28)-1-12 1 1/2"RHR(28)-1-10 10"RHR(28)-1-5 10"RHR(28)-1-17 N8 N9 (REF.)

N9 N8 RHR-V-11B (REF.)

RHR-HX-1B M521-1 (G/6)

RHR-HX-1A M521-1 (G/13)

E12-F065