RTS Instrumentation 3.3.1 Table 3.3.1-1 (page 4 of 5)

Reactor Trip System Instrumentation Note 1: Overtemperature AT The Overtemperature AT Function Allowable Value shall not exceed the following nominal trip setpolnt by more than 2.0% of AT span.

AT <AToK1-K2(1 +

) T-T'+ K3(P-P')- fl(AI)}

Where: AT is measured RCS AT, OF.

ATO is the indicated AT at RTP, OF.

s is the Laplace transform operator, sec 1.

T is the measured RCS average temperature, OF.

T' is the nominal Tavg at RTP, S [*]"F.

P is the measured pressurizer pressure, psig PI is the nominal RCS operating pressure, 2 [1*] psig K1 S [*]

K2 > [*]/"F K3 Ž [*]/psig

-il[*j sec

¶2 S [*] sec f1(AI)

[ (*J([*]

(qt -

qb))

when qt qb < [*]% RTP 0

when [*]? RTP < qt -

[*] % RTP

[*]j(qt -

qb) -

(*J) when qt qb > [*]% RTP Where qt and qb are percent RTP in the upper and lower halves of the core, respectively, and qt + qb is the total THERMAL POWER in percent RTP.

The values denoted with [*] are specified in the COLR.

North Anna Units 1 and 2 3.3.1-16