SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT C P. 0. Box 15830, Sacramento CA 95852-1830, (916) 452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA MPC&D 05-104 September 27, 2005 U.S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555 Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. DPR-54 DERIVED CONCENTRATION GUIDELINE LEVELS FOR RANCHO SECO INDUSTRIAL AREA STRUCTURAL SURFACES Attention: John Hickman In SMUD letter MPC&D 05-077, dated July 14, 2005, we submitted a copy of Decommissioning Technical Basis Document DTBD-04-004 "DCGLs for RSNGS Structural Surfaces," Revision 0.

As stated in the DTBD, the RESRAD-BUILD v3.22 calculation gave an erroneous result for the single nuclide Derived Concentration Guideline Level (DCGL) value for Eu-1 54 due to a known coding problem contained in RESRAD-BUILD v3.22.

Argonne National Laboratory has since corrected this problem and has issued RESRAD-BUILD v3.3, dated August 25, 2005. We have used this updated version to re-calculate a single nuclide DCGL value for Eu-154 and issued Revision 1 to DTBD-04-004. Since there were no other changes to the assumptions or scenario contained in DTBD-04-004, Revision 0, this letter will serve to document the revised material contained in DTBD-04-004, Revision 1. These changes include:

  • A new dose conversion factor value for Eu-154 of 8.43E-04 mrem/yr per dpm/100 cm2 in.10,
  • A new single nuclide DCGL value for Eu-154 of 2.97E+04 dpm/100 cm2 including deletion of the associated footnote in Attachment 8.10, gi A0o RANCHO SECO NUCLEAR GENERATING STATION 0 14440 Twin Cities Road, Herald, CA 95638-9799; (209) 333-2935

~

MPC&D 05-104

  • Revised RESRAD-BUILD report excerpts for Eu-154 in Attachments 8.4, 8.6, 8.8, and 8.9, and
  • Revised sensitive parameter results for Eu-154 in Attachment 8.5.

As they become available, we will submit additional DTBDs in anticipation that the review of these documents will facilitate NRC review and approval of the LTP to be submitted later this year. Members of your staff with questions requiring additional information or clarification may contact Bob Jones at (916) 732-4843.

Sincerely, Steve Redeker Manager, Plant Closure and Decommissioning