ES-401 ANO1-09-2005 Written Examination Form ES-401-9 Review Worksheet (password: qwert) (TAC#: X02287)

Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 1

H 3

X X

X U(S) doesnt qualify as modified - must count as Bank; change appropriate to required in stem to ensure only one answer (o/w, D may be correct); doesnt test knwldg of the REASONS for EOP actions per KA; (Replaced with NEW) 2 H

2 X

E(S)

Tpzr is not Tsat for 1900#; recommend changing to 1400# in pzr and 20# in QT in order to really test something; (replaced w/ MODIFIED) 3

  • H 3

S(S)

(Replaced with BANK; cannot count as MODIFIED) 4 F

2 E(S)

NRC-2004; LOK is F vice H; (replaced w/BANK) 5 F

3 X

X X

U(S)

A and C are too similar to be credible; B and D are the same - need to specify that order of actions is important; (Replaced with NEW) 6 F

3 X

U(S) doesnt test knowledge of REASONS for isolating letdown per KA; (replaced w/NEW) 7 H

3 S(S)

(replaced w/NEW) 8 F

3 S(S)

(replaced w/BANK;)

9 H

3 S(S)

(replaced w/BANK)

Instructions

[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

2.

Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

3.

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

One or more distractors is (are) not credible.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4.

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

5.

Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches are unacceptable).

6.

Based on the reviewers judgment, is the question as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

7.

At a minimum, explain any U ratings (e.g., how the Appendix B psychometric attributes are not being met).

33 of 34 NUREG-1021, Draft Revision 9

ES-401 2

Form ES-401-9 Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 10 H

3 X

E(S) change A to 495F and C to 24 ft; (replaced w/NEW) 11 H

3 S

12 F

3 S

13 H

3 S

14 H

3 S

15 H

3 X

U(S) doesnt test knowledge of REASONS... per KA; (replaced w/NEW) 16 F

2 X

U(S)

C is not credible; (Fixed) 17 F

3 S(S)

(replaced w/NEW) 18 F

3 X

U(S)

B is not credible; (replaced w/BANK) 19 H

3 S

20 F

3 S

21 H

2 S(S)

(replaced w/ what was Q#22 in DRAFT) 22 H

2 S(S)

(replaced w/BANK) 23 F

3 X

X U(S)

C and D are subsets of A and B respectively; D is also correct; (replaced w/NEW) 24 F

3 X

U(S)

NRC-2004 RO#80 - NRC identified; doesnt test knowledge of the REASONS... per KA; (replaced w/ what was Q#25 in DRAFT) 25 F

3 S(S)

(replaced w/BANK) 26 H

3 S

27 H

3 S

28 H

3 S(S)

(replaced w/NEW) 29 H

3 S

34 of 34 NUREG-1021, Draft Revision 9

ES-401 2

Form ES-401-9 Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 30 H

2 X

U(S)

A is not credible; (Fixed) 31 F

3 S(S)

(MODIFIED) 32 H

3 X

U(S) change ? to : in stem; A is too close to D and is also incorrectly worded - should refer to gas volume rather than gas pressure; (MODIFIED) 33 H

3 S(S)

(MODIFIED) 34 H

3 X

U(S)

A, C, and D are not credible; (replaced w/NEW) 35 F

2 S

36 F

2 S

37 H

2 S

38 F*

3 E(S)

LOK is F vice H; (Fixed) 39 H

3 S(S)

(replaced w/BANK) 40 H

2 S(S)

(MODIFIED) 41 H

3 X

U(S)

Dis not credible; (Fixed) 42 F

3 E(S) only use two ES channel combinations for answers; (Fixed) 43 F

3 S

44 H

3 S

45 H

3 S

46 F

2 S

47 H

3 S

48 F

3 X

U(S) doesnt test ability to USE PROCEDURES to correct... per KA; explanation for C and D doesnt match Q; (Fixed) 34 of 34 NUREG-1021, Draft Revision 9

ES-401 2

Form ES-401-9 Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 49 F

3 S(S)

(replaced w/NEW) 50 H

3 S(S)

(MODIFIED) 51 F

3 S

52 F

3 X

U(S)

D is not credible; (Fixed) 53 H

3 X

U(S) need to clarify importance of order in answers; (Fixed) 54 H

3 S

55 F

1 X

U(S)

NRC-2002 RO#12? AND NRC-2004 RO#13 - NRC identified; too easy -

answer is obvious; B is not credible; (replaced w/ MODIFIED) 56 H

2 S

57 H

3 X

U(S)

KA on Q form doesnt match outline; (MODIFIED) 58 F

3 X

U(S)

A is not credible; (MODIFIED) 59 F

3 X

U(S) doesnt test ability to recognize INDICATIONS FOR SYSTEM OPERATING PARAMETERS which are TS entries per KA; (replaced w/NEW) 60 F

3 S

61 H

3 S(S)

(replaced w/BANK) 62 H

2 S(S)

(MODIFIED; typo in explanation) 63 H

3 S

64 H

3 S

65 H

3 S(S)

(replaced w/NEW) 66 H

3 S(S)

(MODIFIED) 34 of 34 NUREG-1021, Draft Revision 9

ES-401 2

Form ES-401-9 Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 67 F

3 S

68 F

2 X

U(S) there is no correct answer since 300F is not required; (MODIFIED) 69 F

2 S

70 F

2 S(S)

(replaced w/BANK) 71 H

3 S

72 F

3 X

U(S) doesnt test knowledge of radiation exposure limits including permissible levels IN EXCESS OF THOSE AUTHORIZED per KA; (replaced w/NEW) 73 H

3 E(S) add -ing to A and B for consistency; 74 F

2 S

75 F

2 E(S) eliminate are correct from each distractor; (replaced w/ MODIFIED) 76 H

3 S

77 H

3 X

E(S)

is D arguably a correct answer? (Fixed) 78 H

3 S

79 H

2 S

80 H

3 S

81 H

3 S

82 H

3 S

83 H

3 S

84 H

3 S

85 H

3 E(S) typo in KA section of Q form; (Fixed) 86 H

3 S

34 of 34 NUREG-1021, Draft Revision 9

ES-401 2

Form ES-401-9 Q#

1.

LOK (F/H) 2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other 6.

U/E/S 7.

Explanation Stem Focus Cues T/F Cred.

Dist.

Partial Job-Link Minutia

  1. /

units Back-ward Q=

K/A SRO Only 87 F*(H) 3 X

U(S)

LOK is F vice H; doesnt test knowledge of LCO for PRT per KA; (Replaced) 88 H

3 S

89 H

3 S

90 H

2 X

U(S)

B is not credible; (fixed) 91 H

3 S

92 H

2 S

93 H

3 X

U(S)

B is not credible; (fixed) 94 H

3 S

95 H

3 S

96

  • H 2

E(S) doesnt qualify as modified - must count as bank; (fixed) 97 H

3 S

98 H

2 X

U(S) no correct answer; (fixed) 99 H

3 S

100

  • H 2

X U(S)

doesnt qualify as modified - must count as bank; doesnt test knowledge of the BASES for prioritizing... per KA; (fixed)

RO 45 8

44H 31F 4X 11X 6X 8X 21U 7E RO TOTALS SRO 11 2

24H 1F 2X 2X 2X 5U 3E SRO TOTALS

GENERAL COMMENT

S:

1.

NOTE: Bank questions are indicated by ; Modified are indicated by comment resolution is indicated in blue; 34 of 34 NUREG-1021, Draft Revision 9