ML052630464

From kanterella
Jump to navigation Jump to search
Ford Nuclear Reactor Technical Specifications Amendment; Elimination and Relaxation of Specifications Following Permanent Cessation of Operations
ML052630464
Person / Time
Site: University of Michigan
(R-028)
Issue date: 09/08/2005
From: Ceccio S
University of Michigan
To:
Document Control Desk, NRC/FSME
References
05-006
Download: ML052630464 (57)


Text

/

OIce Se gipt'ember 2005 MICHIGAN MEMORIAL -PHOENIX PROJECT PHOENIX MEMORIAL LABORATORY FORD NUCLEAR REACTOR ANN ARBOR, MICHIGAN 48109-2100 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Docket 50-2, License R-28

Subject:

Ford Nuclear Reactor Technical Specifications Amendment; Elimination and Relaxation of Specifications Following Permanent Caseation of Operations The University of Michigan, Ford Nuclear Reactor is requesting that the Technical Specifications for the Ford Nuclear Reactorbe amended to eliminate those specifications which are not applicable to and relax those specifications no longer appropriate for a facility writh a prohibition on operating and not licensed to possess reactor fuel. These specifications were developed in a manner which allows for continued relaxation of the specification as the decommissioning progresses, thus minimizing licensing actions at future dates.

The University of Michigan's Ford Nuclear Reactor ceased operating on July 3, 2003. The reactor core wivas disassembled beginning July 7, 2003 and completed July 8, 2003 where in the irradiated reactor fuel was removed from the reactor support grid and moved to in-pool storage locations pending shipment to the DOE Savannah River Site. All new, unirradiated reactor fuel was removed from the site and transferred to the U.S. Department of Energy (DOE) via BWXT Technologies in Lynchburg, Virginia on August 20, 2003. In the Fall of 2003 seven shipments of irradiated reactor fuel to the DOE Savannah River Site were completed by the University of Michigan. With the final shipment, completed December 16, 2003, the Ford Nuclear Reactor no longer had reactor fuel on-site. On 29 January 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Steady State and Maximum Power Levels: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." Additionally the license condition allowing for the possession of reactor fuel under I OCFR70 was removed.

The evaluation supporting the requested changes to the Technical Specifications is enclosed as are the proposed Technical Specifications. These changes to the Technical Specifications are being submitted separate from the Decommissioning Plan, but approval with or before the approval of the Decommissioning Plan is requested. These changes to the Technical Specifications are necessary for and consistent with the actions described in the previously submitted Decommissioning Plan.

If there are any questions regarding this information, please feel free to contact Christopher W. Becker at (734) 764-6224.

I declare undepialty of perjury that the foregoing is true and correct.

Signature: _r:___

Steven C. Ceccio, Ph.D.

Director, Michigan Memorial Phoenix Project Executed on: -

' 0 <

Enclosure:

Evaluation to Support Amendment Request Technical Specifications: Amendment XX, undated.

Cc: Patrick Isaac File: Correspondence 05-006 Ucense Amendment - Elimination of Specifications following shutdow n C:\\Documents and Settings\\cwbecker\\My Documents\\UofM\\General\\Letter File\\CY05\\05-006.wpd 100Z 1 A-t)(1 Phone: (734) 764-6213 Fax: (734) 763.7863 www.umich.edu/-mmpg Phone: (734) 764-6213 Fax: (734) 763-7863 www.umich.edu/-mmpp/

Evaluation to Support Technical Specifications Amendment; Elimination of Specifications Following Permanent Caseation of Operations Safety Limits Safety Limits for nuclear reactors are limits on important process variables found to be necessary to reasonably protect the integrity of certain physical barriers that guard against the uncontrolled release of radioactivity. [10 CFR 36(c)(1)(i)(A)] The University of Michigan's Ford Nuclear Reactor (FNR) ceased operating on July 3, 2003. The reactor core wvas disassembled beginning July 7, 2003 and completed July 8, 2003. The irradiated reactor fuel wvas removed from the reactor support grid and moved to in-pool storage locations pending shipment to the DOE Savannah River Site. All new, unirradiated reactor fuel was removed from the site and transferred to the U.S. Department of Energy (DOE) via BWXT Technologies in Lynchburg, Virginia on August 20, 2003. In the Fall of 2003 seven shipments of irradiated reactor fuel to the DOE Savannah River Site were completed by the University of Michigan.

With the final shipment, completed December 16, 2003, the Ford Nuclear Reactor no longer had reactor fuel on-site.

(See letter sent to US NRC certifying Permanent Fuel Removal dated December 17, 2003.). On 29 January 2004 the license for the Ford Nuclear Reactor wvas modified with the following condition: "Steady State and Maximum Power Levels: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

As the Safety Limits contained in the operating Technical Specifications were for the protection of the cladding integrity of the reactor fuel during reactor operation, these safety limits can be removed from the Technical Specifications. The Technical Specification changes required are:

2.1 Safety Limits Applicability As the Safety Limits were for the protection of the cladding integrity of the reactor fuel during reactor operation, all safety limits have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under I OCFR70 was removed.

2.1.1 Safet) Limits in tlc ForuCed C-onvectiaz MIode Thi;s Specification. app}ie.s to die intenclated %ariabls associated XVifll COIC 11sCILUA arid lryd a ulic

  • ,C~fo,,.,,cc ;., the steady state witlL f&i.d c ciortAlonv.

t T1.c ayables a Rc

.tor Th I v

,1 A 0

Rcter

_-oa_

D_ _t__npt At_ e f f:eightof W__t t

._~ Atha of tr__

_ro____

To ass5urC that thc in.tep ity of die fulel clad is, maintained 1.

TlC titl %3IC Baltc f,attOL POW= (It) shall not execeed 4.68

~w acid die L,tc ialtic of flowa(,..3 sh~all not be. less tlzal 900 gpn'-

2.

qX tl.. lo value oflCaCtoZ C0011t finlet tm,..aiattm, (To) at 2 ?v, nhall not cwcecd 1 16 E

I fltm

3.

Tlic ti te %alue of n ater high61t absove tlhc co, c (II) slid!!..ot be lcs llvals 18 feet Mililc dhc reactor iS opectirnt Tlc b/asis fo. fo..cd com.ection.safett i;...ts ia tl, t tlhc taenlipciz asxlass

~v~~

tc.,

c~t ;.. tlhc botta.n of Hie. l.ot clhu.nl oftlnsc..

t cou.t FNrI co, (25 cC..c.t.3t) n il.ot aCIh th.e boilins o;int of tle~ >' ate!.oolarit.

2.1.2 Safety LHmits ist the Natural Com-ection AMode i.;lLfv't.

A 0.

I..T 0

fZ.. Co..

2cf. b..in..,c ;

thl. nfla....

a.ctio ot lact mofo.tde

..nofa...atu.... Tlics) vaIlibles car.

RcfcttOL 'Hie! Inal PO-M.,, r Rcato. e0013t 1111Ct Tc... CattnC,

' 1t roFrt

Abo, Top orL r01 ss To lsatirc ltlat d.c ilitclity oH= fiucl cla 13 fS niftc..tcd.

Si Tmlly LiC mitUn OSIatC yCttegs f

InclarM rorCL are sit,ot i

xccf d um0 kp nr those2variab havg s at se fntonsL C FR1311t inl~t.C)(pC1)tt1 (T-ii )

(

a).

A ot cL tSccmt 13ty

3. Tlot laniedit o theoer ehncl Specif aboc tilo we (fo ) the pr ot of less thelad Inte o

t.

Tlhe basis fmi t

tinal sOat tectiong bety low.cta bs rte t tf calculated Specitifit i cladding tcis. tatte hni cal lhot ch~an...l of tlic *osst coin -uact FNJR CorC (25 clc..c..t) -nil!..ot zeacl. tlhc -Il.

o;t Gf tlc watc.

coolnc t at a dne tl of 13u fret.

Limiting Safety System Settings Similarly, Limiting Safety System Settings for nuclear reactors are settings for automatic protection devices related to those variablebhaving significant safety functions [10 CFR 50.36(c)(1)(ii)(A)]. As theLimiting Safety System Settings contained in the operating Technical Specifications were for the protection of the cladding integrity of the now removed reactor fuel, the limiting safety system settings below can be removed from the Technical Specifications. The Technical Specification changes required are:

2.2 Limiting Safety System Settings (LSSS)

Applicability As the Limiting Safety System Settings were for the protection of the cladding integrity of the reactor fuel during reactor operation, all limiting safety system settings have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under IOCFR70 was removed.

Limting 31t)

~tetSetngi t. e FoA,.c.d-C-.*n ecio M Tlrsa specCf;cat;On! aplics to fl!C set poinls fo, tl!c safe ly-chvatumsC Illattitolilsrs ssactot flicilll Pot%

CL (P),jJssijTrCOulallt fluO V%(xs10bCirllt of ~tCL abovtlcth top ofthe corc (II),.orc exit temsperatme (9c) andv cote in.ict t~snzpctat~s T

).

To naSUIC flbt 2ttltOIZLatiC iLOtCCt;i;C tal s aiitaLJ oL..c, a

3 afst) lfAbut 13 C

rl.

2.22 L:

1 d; 1

C ffiEl.tily 33t

3) tLIZ S 3 i~ Lb..Ni~aa

!FOIC 1

(M, iJ..ivu (Tc

_tlso!!

be as

_ilons f

Us; (Min)

+9 -ftrssarau*uc[u suiwo s)aa wvv wual sr

(-=-

. L rc D23es tn-qqz l ralztn a fct sys.W sctlksfovbcdcnrcinamu lft2t^-

ltCFltiCa-t~l%-

tile mostse v C&Cabl!OLIIM situatin anti~iptcd bnfbe a re ylii scxcdd 2.2.2~

ss LiiigSaft ytmSttn1 nteNama

-i cto lwMd TlICOC S;>HtCtlCatiOlIS Oaly tO HIIC Stsk f.!eaic C11LIasuCIS IIIOLT~tOM1 I sC3CtOL titICs lT~ PO WCS (P), Foul %%atcL lrcl (II), and pool at..CL tclPC!3atutc (T).

To aztsuC tHlat autormati.

uroteCtiv c acti;onv is itiatC.d to icn.'Cst a safcty liizut fiuotncinu b jCAccdcd 1 T.

c litiklb 3afiCty 3 y3tCs.1L 5tLsI

! :n u

.aat OL HjC1al PO" a

(r311 hciat of vt atc, abo% c tl c tup of tl.c (I,

and pool i

atel t atiLQL ; (1) a17u11 beC as fo~lovn.s II (Max) 0k f 1 (f in

+-t Til limitingu ssbaas; y Syat-lll schi;llba fbi nsatmual com-cction

[vs

!tu sa uvica pitcti s

wz acti ivrll CO__LC.t

__ 11 tS

___C _bILAM Sitltil

~!!p c bc_ _r r sf y *i~

  • is exede.

4...1 I

i.

I.

I.

.I

I lI!l Reactivity Limits The reactivity limits currently contained in the Technical Specification are administrative constraints on operational characteristics adhered to during the operation of the reactor. These reactivity limits contained in the operating Technical Specifications applied to the reactivity of the reactor core, the reactivity wvorths of the control rods, and the reactivity of experiments to ensure that the reactor could be controlled and shutdown at all times and that the safety limits contained in the Technical Specification could not be exceeded. All new, unirradiated reactor fuel was removed from the site and transferred to the U.S. Department of Energy (DOE) via BWXT Technologies in Lynchburg, Virginia on August 20, 2003. In the Fall of 2003 seven shipments of irradiated reactor fuel to the DOE Savannah River Site were completed by the University of Michigan. With the final shipment, completed December 16, 2003, the Ford Nuclear Reactor no longer had reactor fuel on-site. (see letter sent to US NRC certifying Permanent Fuel Removal dated December 17, 2003). On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under IOCFR70 was removed.

It is requested that the limiting condition for operation and surveillance requirements associated with reactivity limits be removed from the Technical Specifications.

The proposed Technical Specifications are:

3.1 Reactivity Limits Applicability:

The reactivity limits applied to the reactivity of the reactor core, the reactivity worths of the control rods, and the reactivity of experiments to ensure that the reactor could be controlled and shutdown at all times and to ensure that the safety limits contained in the Technical Specification could not be exceeded. Reactivity limits have been removed from the Technical Specifications.

THzs Spciiation a-pist til cactsi) Of ti.

I _3O co eAnd t lmact _it noso cn,0 tos and c.\\~~Wer iec.t Vcnlc.cacto.

is oricnted nit.l:~ theav htc3T t.......L.

Mfcto.

to.* in...

place, tlhc Iin...its naill n.ot To Mt=u. dint tlhc reactor can bec co.ullel and sh~tilonn.a 41t..c that die safety, limits. id =H=l~

exceeeded.

1. Th1. sh1utdlon maigin 1 J.lat 1 vc to to.d cold, no fic, Mi;ti=l.o.n1dition shJallb at 1cast 0.025 AI%*K,ith all torl..

shinzaafety-.ods fully insczted and die eaulathin Aod fully nithdi4am and 0.0045 A with tlfc

.ost 1.acthc sh;i.safcty.od.aJd tl.c r.gulatn;6 tud fully nitlhdiann, 1

cci, dming tlc p.ccoa U0f

2.

The. otcull core 1.1 33 l..ctiity in.cluding n1.vcalUbl.

pcxif.

1 nctts sli 1not cxUZ d 0.0436 bIo/Ki.

3.

TI.C I.=CtiVity I HtIh of CjJ.C.;.1.C11t3 31h411 b, l;i.tcd Ad follon a, cxcpj~t dUtUib tll., PI..

ocC33 of C

ng r.ec;...t.acti\\Pit>.

Maxriman riJ;d;d u al Mlo>-cable 0.0012 AIKA hidlv idual Seca, cd 6.01> biKAi Total MIoble and Scmited 0.012 AIC.1

4.

Tkicactur 311411 Ls tibmLliticaly atl cast 0.025 AIEdt Cintgf-ac sts to andfionfth c.ctd fI.

1 o co e.

5.

TLx teco siLl1 be subexitial by at kast 0.0 i AEbfbsiuIn af" rodsat rAnim.edfion ie co.,

6.

T1e catn aid!! be tube Luitical by at kst 0.10 AYUkJK u%

hsIfl hLeba y vyu5 ate, m milts3 thalt wn ruI

. _j9 _kI_.

t ill PUiti%_% I=Cti itv~vy ff=01 MCs u aadeuttvak=s Bases:.

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

Maximum Pow Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor -fuel under 1 OCFR70 was removed.

The s3l Ji.tdonL ud yl SpecifkatiX, 3.1 a r

s ussC aul e

uI am Clcltii; aCuuunl,""

bst~qss ctiminstibc ssiti usJs

\\UU %%aatdaciiu idecayttflcxdflci iluvu,

On January 2, 24 bel f

th d Nuclea Reacto m

w follodtg. condition:

Spandfitheond 3.1.2 allowing for tlhenabc s

essi reactor.fuel under 1O R wsbem d

1=aitC C3tji iy CffCd~tS F(1)31iVCI33C irt pkiI31 CU12 tcripertwke f~on9 OF to 116 or2 (2) fiso Fl odut n

s_-

ldup isc p

vicz, (3)port d

i a

frti a

O r

l Ctoa 2 M, hot co (4) fuel bm11 m

s s ucation for 30 dt1 aud (5) mom rAlr evperimen-u rnats~iw vm mra rvrr lAIIIs Sp*ri.iation 3

AtL

  • *.t s

t

.d30 r

rh;Jo ni.

lcxpetin fnt )r al*i. s t.ht. i-

  • rdc stabeCT u

ers ta 30 con s

  • n t

nhc c.

bC1T5*te rb by.th rcno th

.onti ZSpcification 3.1.3 finuts thc reactitit %vorlz of sccncd and total tOp vauc ofteactitit) nhIclJ, if introduced as positiveC step chvartges n ill not camsc f{;l nief.Ct;n..

rt r3.1.4 d B. 1.5 In ida

=

t uIc CV&5 VIill aeii aut;ibfical dwing. fuAl nim cicn' I

to aud fi,.ni tlLe. co-and daznu g u

inAILsafetaytdrinitiria=6 P

r ns.pcctiorr Tfi lasc dint can b p by Lcpa:ciig lil t.t wifl Lcaty n ate, i f th h e

  • iate.,cnccto, lank is 0.04 AJHAC.

MIntaining flie costaibeitical by at lea~t 0.10 I - -

Ein Spc.cificatio..n.1.6 dt1 lly,11MY MtI vtfts altft13 FLO V i&S5 ade L tate 11=a6;h! tv aaSMIC thatt the t aCt0L Wi-ll IC,,;z stibetitical dwingss hcat3 watCL t73113RSc5 that *oulcl add ostith.csactivity.

oSpc~ifications 3.1 "as5i1Xs lsat failLTI. of thce MauLonmdal CW~to.l sy5tem. wi;1..ot izittodluce su~ffi.cint cc

!=Catit ityr to y1cLodce a prompst critical co.ndition..

I Spcsification 3.1.8 sat5ires tlhat thec shsutdomt ed by~s Spsc JYaci~fic-ation 3.1.1 -mill 1JC mest hi thect cncu V a

.OSItl ic 3CLtI'.ItY 3S1LtOLJIA lCaISu.Cd by thl. flOOclsb g; Ot 2M La xj.MkuI.C1t.

1Ppqptr~th

'Yft mh 4I1

.\\.

Applicabilitv:

All surveillance requirements for reactivity limits have been removed from the Technical Specifications This speci.ficaLt;ioA a pies~ to d, tb t.. t Cila e LC~ tiTL.II.J~t fcL Il.LItib it) l11n 1ts.

r.--

T-iu aousc that flie xcactivity limita or~pceificatort.1 nic na; Axceeded.

1.L Shi

.at

  • o

.- ti *.y. rs si!

be nasted

b.

WhYl1..LL CL tIll. fUCl LILLLLLIL3 ill 1ILUQL dh311 HIC ilUlt.;U LUol. IU.t1=6113 aUL CLplaL-cd,,

C.

WVICLLLI ICCL talC CllAllt fhfUCl La ILLL tL i 3ilitll L

io LI IT3LLtt ill all ClLmLLt fuel 1.13s LI13Lrbe Ofui.1101.1h1 1056 inL tl1at IlocatLULn

d.

Wlc cr t j.istiom ofml C tl thl C. StandaUd fuic LI ty to tile ot*i C

Uf the clU MadeL tu ciUlC% L tILL ds 3 idc s

LALLC3t3 iLLL fb0 tILL OU......

OL H

.toc

2.

Sltsafcty

.td tll rally rspcdard p

tlugI ajito cILck fbi s.*llL

  • .*st l-* S

.JrauLUt

3.

TLIC I 3Ci ltMd OHIO=

V Xu Lii lft %NhUSl 33ficty r-Vl iLc

.l6llJfo 3I detc-llulatlo 3lhn!l bL niLLLt.13dlJ kLL to fICL

=pLfllAcLLLt'L iLit~ia tise. T11.t nUALh slhall be %eLified if cULL cULnfisUJtizat tha1ges occUr

.ith coUId Lasonably bL expected tU L LL IL

=ALIILLLLnt catLity

-north VLI1L1Lby tILL C~jJLCLi1C1t MoUthcouldUI cLALLc tILL %afic., speciLfiLd in pceificatiLL3.1.

4.

TILL coLL nLLgLt1itLALmLictivLy AL 4 UiLJrc duringl ica.1byVLate, IhanLfieL3 niJ1b ILL ifiLcd nhenLL'.

liLca'y na.tcr Bases:

On 29 January 2004 the license for the Ford Nuclear Reactor vas modified with the following condition:

"Maximum Power Level: The licensee shhll not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under IOCFR70 was removed.

SJpcifilat;io 4.1.1 -l ;1 ULtL tlLat alzIn 3 vsafcty oUd LLactivity LthS 3L

,.ot JLothdJLraded o. cln.,dl Iby corC ShiL;LLL3.fCty od~ iLL3J9 LLti0LL3 3ILC tIL

3illIle, latbLst soUILL Uf radiationL cxpou3I LU f~cilit) pctLi3UL.LIr.

rUUJ.Lfrl.C.,

f7 leLiULt hispeJLt;ULns o~f shinLL3af~ty iods fbi, 3%%C lli1Lj ON C! tIL L133t tLSl JLCL3 11115 LCj.LLucLLL fiL ILL_

t11 t n ill dJetct z l'V

___LLL

.t

  • of s mclinLL
c.

ck_

__r

.nitLu1l ij.LLctuI

Aitc, 5.11 as se rl ct -d fbl SpLLAf1C1tUULi 4.1.2.

TILL 3pLLifiLJ 11 Sti % CIILLLnL I laingL~

1 toL l11LIcLct it)

'. Ut th Uf LCjJLILLilLnts n'.ill LL33ULL C 1ht tilL ILIILLuI is Iot U-L1L

-b1 LA LLL sLIuJ L..L JtL LLLIL tLuLa ILLItI' it)

ULLII.. fL...L..

,L.LLe

. Tu1:3 3.L fL1tULL L1IUa....... va...... Wuus.

L~fiS r

L UL 11LL5T.

At1~t231l CLi~fiLa110HU I

UIL LULL LLCbdtiC 1CCiLU t1CtI' A)iLcLLI fUL !!LL11y'M)~~tCL t3113fCL3 %'.ill U3=ULL tl 1 LL11tLtU Star) stieLiical1 tLLdCL all poU3iblel LciLLLt3instaticc dttIjb ILL1vy naStLI tL.LLiCL.

Experiments The limidts currently contained in the Technical Specification for reactor experimentsw~hich established the adrministrative constraints for the lowest functional capability or performance level for equipment associated wvith and operational characteristics of experiments conducted in the Ford Nuclear Reactor are no longer needed. On January 29, 2004 the license for the Ford Nuclear Reactr wvas modified with the following condition: "Maximum Powver Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under -OCFR70 was removed.

It is requested that the limiting condition for operation associated with experiments be removed from the Technical Specifications.

The proposed Technical Specifications are:

3.7 Limitations of Experiments Anplicability:

These limits established the administrative constraints for the lowest functional capability or performance level for equipment associated with and operational characteristics of experiments conducted. in the Ford Nuclear Reactor. These limits have been removed from the Technical Specifications.

Ths specification applies to expea mants i..stalled hi tlhe IR.

To..pc.v et d a

ts.o Hl.c icactos o recessiac i..as of tadioactite tita lsa irt tr'i eae..t of anesxp.Linteridt

a.

E.aChs cxpestair t slhass lue Oesign.ed.,

fllfat the Stlufaec taMseIta=C salb.b belowa tale tcIn.etatm calculated fiO tlf

.cn~.

fucleatc bDoiling, r.;O to~ in~se ion; in tlic r~acto a.y Cnpstile n hich is tis calculated ssMTs1 FL esy.

2.

All cxa.;y

... c..t

,ss a^.;la u.c eotaat ovithi aaat~iasasOla.t Asallbau aitlsal aulsaso.

u;iss ta..t o.c.ak~saa latad ssithlls aulsu3ussl rsaistait aulstaffiaa.

3.

Explosi t esateti5l

.als l!

notJ be placed in flu.

zatatuipasl.,

4.

eutro.. iadiogatphy of 6xplosivcls 1sall be con.dus.ctd stitls. Hie exploscs con.taies;..d a lblast proof iadiatiuo containaet, a poatotype of o

.sl-mitl.as1

...ss isua ly testeds.Md de.no.stated.. ot to fail lby

-aetoratiuo ufat least tnicc f tlc arnotuint of aAplu La t bc L

adiatcd.

Tl.e.

.aas.J..as.

a

..s;.as

s.

.u 1 e

n

,sa.a+

1sssl js s jif': JS. sa&O

.ette A

.a**

..t.b......

ss.aaj Z

t1.1t1..atflss..

a i

.j

e.

.1.IAla be lissutad su tflat tld av..plate.laase of all raeuaS, Pad.tilata, aMid % astil CsOpusicLuts fIssI tI..

encastilat;ons COusi not

  • ttsult iii doscs a

Cxccs.,

of 103 uf lis cquivalcit aisisual dose5s state iss i ocrR20.

Tls.; dose lisit applics to PCus!a

uaauCwti, t.ucsuttsCtad aCa5 co..ti;.uously foI ttu lsuuMs. stat;.igS at tisI.a

-f*lc.IasC ansd Lsst.ict asaa Ju.;

i leIe~tlC otitOf ti

..s.jus..td to... eacauate tlea iestricted at.ea

6.

Thcsadioas.ti,.arssstcialauostasst, hicslsdins fis.sisnsproucts, ofansy dotublyc scapslatcdcxpcitis~itsstoulss d

bL lsuitcd so f.lat t.c Complssepate ielaaoa of all g-acous, pjarticulate, o. Volatila eo...o..e.its fions tlhe C,.captUilatiosL could siot *csult isi tloscs ;is a.aaS of llic CajU~ialCsst alusual doc5 statcL ;in 10C:FR2O. T:H;r doas lisnit applie;s to actsons5 sUta~us ti uesLtctcd aMaen C0sstirsouit13ly fo M.O 1tstlsa StMLasHub at ltsC tLII.C ofss.CaSc assl Latawtcd aLaaS Jusiss tha l.c irssStii of tisss. s i

d et actaaaatc fsl..estricted atea.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"MaximumPowerLevel: The licensee shall not operate the reactor norplace fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under 10CFR70 was removed:

Spcifications 3.7.1 tI.61, 3.7.4 asa isstassdad tL red.uce tlsa likelilhood of dasirmz Lt saoctcs cosspousassts ansd sa nctalit itL) elaaaCI s sulL3ss6, fiaos CXaCvusICsst fa6lhTc assd ses v as a guide fio. isa Ca%

ict assd appu sal of..cw assd stija~idca.cpcsissassttsb)-faaility pcs~sorrcal aidtLieSaafC~yRlasias'sCuiissiittca.

IaNtitui adiograph) is aundaatcd in a,

si and at horizonstal beaarsputsL tlint taninsata.at Li lsrat. siata. teflatoI Lalk adjacasst to HiC laaatutl CUIa. fIs LiCa diurljls 0fa.-pl03is bC3, Lila XapI03lia Ja

%till Lb csontained, datsin

-Xp0Us-W, is. ide a blast psLOOfassaluCsUM. Tl.C IassC!3tsaC nill nt 1

ba cotuulcd to Lsh

  • arrstius lid n ill ba aosstsuatad tu sHy auIftais asy last affcts L1iliC MIIs.*.1 s lt La bassaLattd by ass aidsstss detonusatiouss.

I l w,

vr__...

_.v.._

I

.~I..v _........

V V*JI rv Two Ad I.

IT 1

o-

-_s l5UVlllvl19T73.

Hie calctltionsl fiv SAFETYx isANALYSIS

'.x--

-1A...

-. ;t--

k-

.ID, jA O...

I..

I-

1.

l

,Apczhmntl; "diouactivity ffrtit.are pruvid-d in ~wss scein1.3 of the; Reactor Fuel The limits currently contained in the Technical Specification for rector fuel are no longer needed. All new, unirradiated reactor fuel was removed from the site and transferred to the U.S. Department ofEnergy(DOE) via BWXTTechnologies in Lynchburg, Virginia on August 20, 2003. In the Fall of 2003 seven shipments of irradiated reactor fuel to the DOE Savannah River Site were completed by the University of Michigan. With the final shipment, completed December 16, 2003, the Ford Nuclear Reactor no longer had reactor fuel on-site. (see letter sent to US NRC certifying Permanent Fuel Removal dated December 17, 2003). On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition
"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under I OCFR70 was removed.

It is requested that the limiting condition for operation, surveillance requirements, and design features associated with reactor fuel be removed from the Technical Specifications.

The proposed Technical Specifications are:

3.8 Fission Density Limit Applicability:

The fission density limit specified the maximum burnup allowed for a fuel element to ensure fuel failures were not experience during the operation of the reactor. This limit has been removed from the Technical Specifications.

To ups e t et fuel plate san llin.g n i.;c could Occutlt i.. clad r aptat e andl.ceasc of i adioncti c fission p uoducts.

1.

sThs FN fsasih dsaessitssay linitshalla. be 1....t.u.fisasioJ;=

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under I0CFR70 was removed.

Tl~.

d s

  • ~t L j.A F1."tA~ s r *

~

~

l~

ALA IJ..

Hie fssi5ons dCensity saist iS belon-optatonal fission. densities zcachcd... othes opCrating reacturs ti5;ing tl A ceuc.; r. ta l data ba3c dittp ts Hie safc u

se of n uarinuuuialmin;idl (UAlx), t ian;uo.dc (U308), Ad r.ian (

tsilicide (Ut S,2) fuel idie;t EIR ti to die fission dci sit, lirrit seas di.iv..cd fion iadiat.Oatests licifo..ncd ;.. diec Nfatmials Tcst Rcactor (IN19R), tlic Ens.neezing,, 95st Reactor (E:TR), Mid diec Advance Tc.,t R;vltax (A-TR atthe 1daho Nation rlSll~

al

Vau >-I...

i"hs t.m. otope.Rc3uL (HFir) a..,.. Oak P; -

m At.-

  • T t0
  • At di R

Trq3 TS1q rp:

4.7 Fission Density Limits Applicability:

The surveillance requirement for the fission density limit has been removed from the Technical Specifications.

ebctive

1.

Th fissio dcnit o al f;ze ele u

~al> tiai

23. buni sld! b calulte a t ca.wvsus.....

Bases:

.4.

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"MaximumPowerLevel: The licensee shall not operate thereactornorplace fuel elements inthe reactorgrid."

and the condition allowing for the possession of reactor fuel under 10CFR70 was removed.

Detennntion offi.ssion..densities on...a qua. Iealy basis wvill c.nsu. that tlic fis5;..i........n...

d.sityx !inlto o c~Spcificatio, 5.2 3.8 ;..o cxcee rue elc.....

Jn.llg

..-;1 t.. kcct ~.vel Iclo

.v 3

lc 1d bl v

.;c..uld.csut ;...lad LU.tUL,t Reactor Fuel The license for the Ford Nuclear Reactor does not allow for possession of reactor fuel.

TlHc fuil assblie sl.l be of tl. NITR twC, co Sistillg of jlAttC CIIttikliIbg tMaitnl. 3tininide (UAMX),

.xid (U308)v, maniim s;l;cidc (Uzi;2) ftCI CAniched to less tflbn 206 ; die... isotop U235 Hlad tith. altimintin Tlhc aUtlI0Licd fulel assembly> desiELIS s ca..

NtunLc.

Plate hoading,.. Asscifibly Loadin OFrloat (b 1u23)

(C u2S 18 9.28 1/-2%6 IG7 1/-2%6 9

9.28 /-2%

84 i/-296 5.4 Fuel Storage The license for the Ford Nuclear Reactor does not allow for possession of reactor fuel.

1. inadiated fi.cl c.IL...ts LaS fiueled detice shall, t. stod.cd.aal a

.c 1111)

11 yc...It S3 ffciCiXt 12thualt Co..t ectio.

Cl..icol;..g b) t u-atc. a. sucl tlSaUC l

flf,

clc.Ci..c..t o. f C.J.Ltelcd de ice te...nikpatn c..ll.. ot uCXCCC moo.

2.

All zeactor fiJl clc..c.ts atd fueled detice shall be sto..d.i a gconictric y.vl;ch aSu..

stibci;ticality-. Til~c aliaysP2Cij!,s.illbebascd o..tljc cxPcillelltaliCsulltsjcpoI ted ;.. ORME eF 5-8 9-40 fcb. St6 L3 CX.CFiM61f*t3 pefme

  • witA E..k Ridge RccC and Bulk Shlding 11 Fac.ility fuelJ ec-n*.ts..

Reactivity Control and Reactor Instrumentation Systems Reactivity Control - Originally reactivity control was provided by three shim safety rods and one control rod, subject to reactivity limits on the reactor core and the experiments which could be inserted in the reactor. While reactivity or reactor power was monitored by six neutron detection channels to measure reactor power from the source range to full power: two fission chamber channels (Log Count Rate), two compensated ion chamber channels (Linear Level and Log N), and two uncompensated ion chamber channels (Safety A and B). These channels provided power level indication, reactor scrams, and control interlocks. The shim safety rods and the control rods were each moved by a gear reduction motor or rod drive which were controlled by the rod control systems either manually by the operators or automatically by the auto rundown system, various interlocks, or the linear level servo controller. The shim safety rods were connected to the rod drives by magnets to allow the rods to drop in less than /2 of a second and secure the reactor as controlled by the Safety System.

The shim safety rod and control rod systems can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (I), Maximum Power Level which currently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Log Count Rate System -The Log Count Rate System used two movable fission chambers to monitor reactor power from fuel loading through to full power. The Log Count Rate System indicated the pulses from the fission chamber on a recorder in the control room. This recorder provided and interlock which prevented outward motion of the shim safety rods unless a measurable count rate (> 5 cps) was present on the recorder.

The log count rate system can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (1),

Maximum Power Level which currently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Linear Level - Servo Control System - The Linear Level - Servo Control System monitored reactor power using a compensated ion chamber and used this power signal as an input to a automatic controlled which would provide a signal to raise and lower the control rod to maintain reactor power at a prescribed level. Power level measured by the linear level system was indicated on a recorder in the control room. This recorder provided a signal to initiate a rundown, inward motion of all three shim safety rods, if the indicated power level exceeded 107% as indicated on the recorder.

The purpose of this rundown was to provide automatic action before the reactor reached its licensed maximum power limit of 2.2Mw. The linear level servo system contained a control interlock which automatically returned control to manual if the indicated power were to drop 5% below the current setpoint. This was to prevent automatic withdrawal of the control rod resulting.

The linear level -servo control system can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (1),

Maximum Power Level which currently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Log N System (Safety System Period Channel C) -The Log N Channel monitored reactor power using a compensated ion chamber Power level and reactor period measured by the log N system were indicated on two recorders in the control room. The power level recorder provided a signal to the SCRAM system when reactor power exceeded 5% or I 00kW for both the high power/no flow and the high power/header down SCRAMs. The power level recorder also provided

x a signal to the shim safety rod control systems auto rundown feature when reactor power exceeded 80%, 1.6 MW, for use in providing an auto rundown, auto insertion of the shim safety rods, when the water temperature at an elevation near the top of the fuel exceeded 114 oF. The period recorder provided a signal to the control rod system which prevented outward motion of the control rod when the reactor period was less than 30 seconds and initiated an automatic rundown of the shim safety rods when the period reached 10 seconds.

The Log N System can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (1), Maximum Power Level which curiently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Safety System - The reactor safety system was designed to shut down the reactor and maintain safe, shutdown conditions. The safety system consisted of three separate channels, any one of which was fully capable of shutting dovwn the reactor. The system monitored reactor power using two uncompensated ion chambers and monitored reactor period using an compensate ion chamber (see Log N System above). The safety system interrupted the current to the magnets holding the shim safety rods upon receipt of any one of several signals. The two power level monitors, Safety channels A and B, provided a signal to interrupt magnet current before the power level measured my either exceeded 2.45 MW.

The Log N channel provided a signal to interrupt magnet current when reactor period was 5 seconds or less.

Power to the power supply for the magnets holding up the shim safety rods can also be interrupted, resulting in a reactor scram. The Log N System recorder and the header operating mechanism would provide a signal to interrupt magnet current when reactor exceeded 100 kW and the header mechanism was not fully down., The reactor bridge system would provide a signal to interrupt power to the power supply for the magnets when either of two mechanical clamps holding the reactor bridge in position were opened. The header operating mechanism and a flow meter in the primary coolant system would provide a signal to interrupt power to the power supply for the magnets if the header mechanism was up and flow measured in one primary coolant flow meter was below 900 gpm. The Log N recorder and a flow meter in the primary coolant system would provide a signal to interrupt power to the power supply for the magnets if the power level was above 5% or 100 kW and flow measured in one primary coolant flow meter was below 900 gpm. The Log N recorder and the butterfly valve in the primary coolant system would provide a signal to interrupt power to the power supply for the magnets if the power level was above 5% or 100 kW and the butter fly valve was not fully open. The Log N recorder and a differential pressure gauge on the holdup tank in the primary coolant system would provide a signal to interrupt power to the power supply for the magnets if the power level was above 5% or 100 kW and the pressure in the I psig below full flow static pressure. Each of the doors over the opening of the beam ports provides a signal to interrupt power to the power supply for the magnets if the door is raised unless this SCRAM is bypassed in the control room. And finally, if the radiation level seen by a gamma detector in the exhaust plenum from the reactor building is I mRem/hr or more a signal is generated which interrupts power to the power supply for the magnets, plus other functions.

Power to the power supply for the magnets can be manually interrupted via a manual scram buttons on the control consul, the beam port floor and the reactor basement and a key-switch on the control consul.

The safety or scram system can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (1),

Maximum Power Level which currently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Temperature System - The temperature system was provided to measure the temperature of the water in the reactor pool near the surface, near the inlet to the core, and several locations in the primary cooling and secondary cooling system. Each of the measured channels was indicated to the operators via a recorder in the control room. This recorder provided signals to the rod control'system which initiated and auto rundown, inward motion of the shim safety rods, if

the temperature of the coolant exiting the reactor exceeded 129 oF or if the bulk temperature of the reactor pool exceeding 129 oF. The temperature system combined with a signal from the Log N power level recorder provided a signal to the rod control system to initiate an auto rundown when reactor power exceeded 80%, 1.6 MW, and when the wvater temperature at an elevation near the top of the fuel exceeded 114 oF.

The temperature system can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR. Current license condition C (1),

Maximum Power Level which currently states 'The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

Flow Measurement System - Two differential pressure transducers in the primary cooling system provided a signal

-to the safety system for the scrams described in that section whenever the measured flow rate fell below 900 gpm. With the permanent cessation of operations AND the permanent removal of all reactor fuel, these systems can be removed.

.The flow measurement system can be removed from the facility along with their limiting conditions for operation and surveillance requirements contained in the Technical Specifications for the FNR..Current license condition C (1),

Maximum Power Level which currently states "The licensee shall not operate the reactor nor place fuel elements in the reactor grid." provides assurance that the health and safety of the University community and the public will not be endangered by operations at the FNR following the removal of these systems and their associated requirements in the Technical Specifications.

v The proposed Technical Specifications are:

3.2 Reactor Safety System I

Applicability:

This establishes the administrative constraints on equipment and operational characteristics that are the lowest

- functional capability.or performance level for safe operation of the reactor. These limits have been removed from the Technical Specifications.

Tlese sp fi,.atinju appjly to

h.
t.

aft) syste and

,.,ln.

safcty zelate.d intitimtatin.

T.,

l1 ~

.,....c.tiab.

'.1

~

~

~ann.t~a...

pu.tfa OM I =CtO

.,afty

.S~t%

3nd aaJ...&,;Rty if.t n...

1. Tl cacto t staf...ty atnid safda)ty jlatd iftStItl^itat;uionar operabl in acdance wifli 3.1
  • nd 3.2 including the,u.inun, mini of J iansx and tl.c indicated,. a....,A.. o *kflu,;,,iu.

oa.ts,

2. -dAll 51i, -afsty.

are optal-,

I..-

3.

Tlcu fi.an Lo... iLtiatCU afa.a..... dtun i.. tln

1C.;t Until thI...hii-safcty.ods amc fully i..ett.d (zi..la.c t.01..),aap iiaaj.n.i.c..

shm!! no sd 500 n1~flia.....u cab s

-u vuontso! rods.

Bases:

On January 29, 2004 the license for the Ford.Nuclear Reactor was modified,with the following condition:

"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under IOCFR70 was removed.

Ntutro.. flu. le vel Sseans pi jovide. edandanitatitoniatic pr~otectiv..action. topre..ent.ex~ceeding tlhc sntficrnI;..t IvhUIAUJL L cto.

1 HiC..b T.

3.; ol s UL.

pe.iod scI; Uni li ts tIlb aUte.;

ofl., i...

clI=

tul tj

, to i.,oi s MI.

ili.L MC.Cty *IM23lY cu llablc ith...

tc.a.

g cc,

...t......

Ic U cis o

f cl Uc

,lpcll.SS iut fC.U...ls Po-noa co;flon. c;'icidet sc.n proid =dtV~ic....d (la.,t.1311IS t.,SUI cl to 21 fu.tl.t.

uto

,nalic los of flow sc.....iam tv ill V~VCl.il;.; tilc 1cvct of3 1055 OHM MIMcl tlc XC 2CtO. is oupciatin a.t pou-c. ktc!-C alobc 100 k-M.

Tlc.ocl %vithdran au-in......

tcloclk o.. the~ Log C-Oun...t R.,te clsic ass,.CIsu s hat tile uc iaeto. I12......

Inatis c.ha.gnIn... a opec..i;.g i..l;,d

indcti,. n.cutio
flux le%.la dain...,

tIhc..jppoa cI to ctitic alitr.>

I uil.Ui..

tell la tUlC1 3

U t

.Ut t,

I

.O tl tti 11...

Lt tutonU~dOM fianctionsand t-e.oul le-%

I 3

! th*tt -l-.

U -m il o t..e '.Imte da b

.o. L,. s.afct r.itb 1r co c init tenipciA.attin..nd bcot tl.

s3~fctt li 1 it foL JJO lCC it Cit C 113t-ll l0 fOL c C OMAI A.AtiULA A17ICJ.,

nustll) sh iutdu..n t11...., tuOL if.

11 tn 1f S

uf.fLii.Lial ui.oditini s3olJuld cceni anud til titonntic ica.arlAUA

__t.ction.do s no fn to.s :^r*s*-.

Tlhe^u scm btof die cl tlacdig ti Anonitu siyso^tcln 233MvC3c thot a=3......... tillo'i fo.i tly in.....icto ajc Hig dition o

Aild c.TiSt I...o..;toccld.

Specificatio.s 3.2.2.. d 3.2.3 a.ssu. th1 tll., saftty S)stc.lIS..juoI3..sc u ill be a 1

p.o; 1 ltC.

M.chanial hulddonnu d icAc.s spccified in 3.2.4 stl. dint a fficl A.kIcn..ct ca...ot be liftld fionk1 tlv.cco.

CO y

ILIM.I.A.M ULU ora.lLkluII AJu """

U'.. I~.aA_.`

Ul~"A 1

A1VI. I UILIAi6 ill

." aUU.IL JJVZILI.

A.

I.l.).L.

Table 3.1 REQUIRED SAFETY CHANNELS NMininiui NumbeL Cll l,Acl S

c

~

tvo;,,ft R

c q

A.;.4U....

c'd

_______to Log Coun.t Rate..

2 cps Rod Wiflidiav.l In tc ilock EOY, N PC.iodid Ian.

ps c

c.c Ic icc, ponetI '.1IA.A Al i*tlloAkAks,..n.

illqtlt fbL FA.Aiod scanl1l PA.,iod Saficty

., see.

.J:.SCa. A CL Sfty 122.5% (2.45 N) 2

'sc I li;ml Po er'No Wa'ter. Flon (a1) 900 p'liSrt~

100 k1v (b) nldujp tank olati, v

1 jnu fuluy fl iour u II(bl. PO

)

..-. / IIC.

IC.

DOUre pb..o DI onet 100 kA Ic.,cl UpIAO WY tc. HlOWU 900 U'j..n 1

sI.. 1 Building Ediatt Radimion LA '.c 1 nnerr~il 1

sArl 1

Iluildinp, Mann fldwantal^J nitch1Jzal Niantial Setantl Sni-tils 1

CIZU11 B;lIa~b IP~UJ1J tlvwiLc.l.

.JIJ;.l 1

Jc 'un Reacte, Czoolan.....t IHelt Tc.....

114 ol:F Auto Rtin..do~vn i) 1.G61,1W RcactOL C-0a1st E.it TC11.

129 1

ALAt6 Rticlo"M' Reactot Pool TempezCSattutc 1

29 OF...

1 Auto Rundo t%.

Pool 1%

I fo~t lbclo pool orciflu 1

Auto RWdUo-n N';1bs N.ot Claik.l.C.

1 l

1 A Ckals Table 3.2 REQUIRED SAFETY RELATED INSTRU1ILIETATION Nunibc Cl,cl Stvo.,t RcWu;.

dFunctio,.

Efilca, Lcvvl C-1amulcl As Requ;ired.

EilIL;cal Mo X c. -I ;

iUnea3suciAnet and inpLut fo.

Poc L.rcl Detiat;ILnLtflock 9.fCLt.....

9!t5%Ctf rl~ l

1.

Retunt cacpttO IMa l iLCl hlI

  • ..o0de if setpo' Mt iS MwaChlCd ReatO C-U3l l~ld TIIlPL~ttl C ?i~t

,1FX.i.dL i

1 PL idC ilfOllIMHO~ fbi ICt~O poaveCL Icv-l dlftCsssulat;OsI bvy licatbalance

.7-gt.

n 1'

1.

Buildin...g Ai, I hatiast l....(l)b,jv-rj Asicsss 1 I.11 Sa ALL As &I 5C a ss s ;aft Co.f.

aiUatLOU Note:

The limiting conditionsforoperation associated witfi the buildingexhlaustradiation monitor have been moved to 3.3, FNR Confinement as described in another section of this Tecinical Specification Amendment.

2.

Dtidgc 4.(50)b B

NW C-lnn Beampoft Flo 20.....8-

4.

11 H

oIl, DauiOpId ri O

5(50)L inuenA;u A1lC S.* *

  • *
  • a, *.....

.........IIL 1...

Akin1.

5.

NED C-ounin, earnpor For 5(5vlzllr~

1C sA13II Note:

Th7e limiting conditions for operation associated wit/a the area radiation monitors have been moved to 3.5, Radiation Monitoring as described in another section of this Technical Specification Amendment.

I fication* mendment.

a.

'ot *-qu fcd rL at11 al 2

1c OIV..ctiOl OJIatiuol.

b.

Thcf faiity) iiatiou i

io i ystch ro s

sist ofS.liad;u

  • Iil alatt a.

Ile.ad out locally,

,,nd ae.ecordled ;., tlhe co..tol,oo,,,. Tile..o....l1 seto;..lts fo, tl.;s syste.m are sh~on,. Tlie Valtve ;.,

,ai..lth~eses ia tle...;.u.st;.

UI;l

lIeue ~~,k;.olele.dto

.ICFi.C Us fl;Ie H=

,.o... 1 3Ctpoi..tJn ili.Lttl

11,O.3; ~~,o1 of rI Ntle'icca, R. actor Eabom tULY fII3C aae o,1 o,.e of4tl.e iSstat MIaab1.13. Lilly,e. t o,- 3tfff.1T1I.bCL 111fty adj03t a $Atpui..t loun%., tlu L.,

the..oal

%:!u.

C.

Iff1 cility.diat;

..o..;to, 3., 4., o, 5. is laed outof 5e

.e fo,,ue,;od of,,.o. tha..7 days, tl.c1e.actO slall lbe sliut d it o, tl.e...2;ito, s1all be e.placcdbd l a leA. Y 31=11L)S t.L;t of 3

i;,uH,

,..1e. Slhutld-a seeo..d of these...o..;tos bce placcdl otit oF M%

i;c, tlhc I;CMtOL n ill bc slult dunn..t..lcss tlhe...o..;utoi I CttIL l.ie to se,.;cce i>thin. 2411ILous oL ;5.cplacdlb~y a seconsd lucall~y'alai citin ussit of 3in&ll sa31i C.

4.2 Reactor Safety System Applicability:

This specification applied to the surveillance of the reactor safety system. These surveillance requirements have been removed from the Technical Specifications.

This s lecif cation. applies o tflc 5sa. cillanc l

of tile,actol sact sy.stcr...

ebiecti%.-c To.155Uz tlhat thClac satVA safety systc.. iS peteablel aS icusn;,d by Specifications 3.2.

1.

A Chnli amoci te.at Of tle IiletC flac, C SalCt; Cha....mn..u.ust..I...,...Ii..a...i.n..I

...l

.1.Ly1..iIn..C1

, 105l, CIOt I a1k 1 liafiniCI',,id one flo coni*

c sc ns shal bc pelbme M.

PI.;O, to C3Ch, 1C3Ct0I Starttlp foH llyw, a,e,;odl.II he,,

&CtleCtOl %V33 SMILH,d

b.

Afle, a channel 1.as lee.n, cUpail1do, deei..ievld.

2.

A Jlani

.ealil.atiun oftl. 3acty Jl.a.nels listd ;.Tablo 3.1,..I.;el. e.. I1e.alilbaJte, slall lbe. Hefo,,,,cl 3n=Iallyr

3.

A clJannel c.li.k offtlne.,.utto,. fl.i 1..-..lc safty cl..l csdlt3 1

1.b sLCaJ.

tO1 1LJCj.tIL II11111II. tl.c..l

.l outtpjti

% ith a licat balance.,

ai.! bc pc fol.un.d 3110 d1fly 3fiCL =ChinSv CIPCsatuh2b POu e, lev el and.veekly flicn.caflc. if tl. rct..ot, is to beo.c.ated at a thn..ial po %

1.,

level abo c' 500 kn.

4.

Tlnc cp..patio.n of tl.c,adiatio n.n..i.h;tuh.;i gssteu

...cujui;.cd in. Table 3.2 slhall l...CrifflJ.

Pr.;O. to ac3Ch

.cacto. St>.llp follounins a pcsiod t=

H^'ICI =l;CtCL VMS scctlzcd,

b.

Aftc, a chanuicl 11., bccL,, Jc.ic,,cgind.

c.

IfHa ch

. h.1.4. 11 Vicrbcc..

1.cd, a. upie.ratio. and setpoJint %. ificatio.n :ill bc pcJ.Afo d.J

jio, to s.J..
5.

Tinc iadiatiuo. I1oLntul 3s-t..u.,.icqucd i;, Tablc 3.2 s311! be calib.

1 at 1

d313 nid 11an.ally.

Note:

The surveillance requirements for the building exhaust radiation monitor have been moved to 4.3. FNR Confinement as described in another section of this Technical Specif cation Amendment.

Note:

Thesturveillance requirements associated with the area radiation monitors have been moved to 4.5, Radiation M-fonitoring as described in another section of this Technical Specification Amendnment.

6.

ShIT.3fsacty Lod resccdLCIJPc l;...c s1.a1! lc nicastried.

Annuallytu WVhmi.11.b a shim,,-safety ioud's coic locatio. is c.ans..cd,

c.

Wh'Ic..cvc,, timitcn.an.c is pcrfmio.cJ that could affect tlhc,od's dLO},t..c Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition:

"Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

and the condition allowing for the possession of reactor fuel under I OCFR70 was removed.

P s wataittlpc luu t.) 's.fz 3.yfcty atk~'.AIlIin...

yt1,i ao p1abiliy.

..,uuaric atavb aidct.ta a lly-sui ks Ut.

& i ltflJ at is not detected 1by n2ornial I3tCLCO12.suajSO. l dfkhlvaLICIS. Til.e.Cha4lml chleck ftl...

ofx l.vcl cliamuicis asatess tssat flic detectOLS M~C duuusyvJ~~

to acematel~ nsonitol t,.C,uMIlsCtCL thcy M~C m

e Iddi~ations nsont~s are checkcd. fbL kLO.uA operationi n Spcifiscation 4.2.4..C-aliLation and setpoinXt ifcaton ;i.vol usc O a aliration. somce anld S ibkifzkaklt JuCJ3ISUOIJ aIIJIQIAUII 2-haU3UJ.C.

acSu.I uIL alU 2-alibL36011k ofadIiatioA monUiLtors, vvlUh iL c dipa cd cxeln stablity U'.c r-kInylI y

2 - 0 1 of Ukp-kkt ati 1

adeq uate.

to Y.2 Li If il.

32-tpoin~t arlesS-3 hT~tfrtlll2l~lLlt..k'ai13ha'.2 bc...LI m~ade..

Tl.c incwasmd cIaeased-ip, tLims of tlhe shint saf2t-y iuds lare bl.c 1 co.siStCL2...t 3SiIcU a..

OIC

)Lallat;0ll Uf th2 but ortsta11incss stccl shbim aafct) zIodiut 1992 and tlhe bl/oro-alumuhintul alloy s1hufi af2 -ty rods uh 1994. Amit1 al clacck of thesca puaalfstintsa i.s COiS ide~cd adecitiateto 10cittct atry dicteiorations %iltich could chan.ge -the rIclaSechclop timsc. Din.di.g, o. rUbbiL.., cati~sO!by,,.Ld..7salipmu.cnt.ouldiest~ut fi oins zimintMIMICCt thl Cfbrov, rclc.,sc dlop thims w0ill be checlkedl aftcrs ucls t nmitcntissus-2L.....

.f

[1...... 1 kk l..t...13 1

I.)J

- L 22.ju L

.2I

..L.l d2L..LL~h

.'.11.

...O..d 1..

12-..3.-d~pti1..., 1 d 1 kIktl

.~f.d

~

U il~lbu.2

..UA i2.,l flu II l~

al..,

I.

I I

f.I f I,

t J.

I I.

l:

'. i.

Reactor Building Confinement The reactor building is designed to restrict leakage and is equipped with a general ventilation system that provides the primary heating for the building and exhausts through a stack on the roof. Supply air and primary exhaust air are drawn through the air handling equipment room, where all supply air enters the building and most exhaust air is pushed to the stack on the roof. Both the supply and exhaust ducts can be isolated by dampers to establish confinement and utilize single pneumatic cylinder which holds the dampers open using the reactor building compressed air system. A signal from the building exhaust monitoring system described in the following section can cause the pneumatic cylinder to vent, closing both dampers. A smaller exhaust ventilation system in the reactor building is also connected to the a laboratory exhaust stack in the contiguous Phoenix Memorial Laboratory (PML). This system draws air from the reactor building via a bolted flange to two circular ducts that are sleeved through the north wall of PML and the south wall of the reactor building.

Previous evaluations of the potential radiation exposure to persons at the operations boundary (outside the reactor building) following an accidental release of fission products within the reactor building used a leakage rate from the reactor building of 10% of the building volume per day and concluded that the accident doses would be acceptable. To ensure the basis of this evaluation the Technical Specifications requires the following automatic actions upon the detection of a radiation level or release of radioactive materials from the reactor building exhaust system equal to or greater than the limits discussed in the following section: a) The reactor building ventilation supply and exhaust fans shall automatically turn off; b) The reactor building ventilation supply and exhaust dampers shall automatically close; c)

Unless the duct is otherwise closed or sealed shut, the beam port exhaust damper to Stack 2 shall automatically close; and d) Unless the duct is otherwise closed or sealed shut, the room 3103 hood exhaust damper to Stack 2 shall automatically close. These conditions are continued from the previous license, except that the automatic closure of the dampers to stack 2 is not required if the duct is otherwise closed, i.e. the damper has been manually closed, or the penetrations through the reactor building wall have been mechanically sealed, i.e. permanently closed.

It is proposed that the operation of the required dampers be tested quarterly. Experience with testing these dampers for the past years of operation of the reactor shows that this interval is sufficient to ensure their ability to provide automatic isolation when the radiation level or concentration of radioactive materials from the reactor building exhaust system is equal to or greater than the limits discussed in the following section. The proposed quarterly functional confinement closure test is also consistent with the recommendation of ANSI 15.1 (1990), The Development of Technical Specif ications for Research Reactors.

Additionally, during the conduct ofactivities within the reactor building which could lead to the release of radioactivity from the facility the following conditions will continue to be administratively controlled: a) Personnel access doors will be closed except as necessary for the passage of personnel or equipment; b) The main equipment access door onto the beam port floor will be opened only long enough to permit the passage of equipment; c) The personnel door to the cooling tower area will remain closed except to permit the passage of personnel or equipment to the cooling tower area; d) The access hatch from grade level to the beam port floor will be sealed closed. and e) The personnel exit door located in the north wall of the building will be sealed.

The semiannual inspection of the gaskets for the building ventilation system intake and exhaust dampers, the personnel access doors, the equipment access doors, and cooling tower access door will continue.

To facilitate equipment access for decommissioning it is requested that the door located on the beamport floor which connects to the PML hot cave operating area also be allowed to be administratively controlled as closed except to permit the passage of personnel or equipment. This 4 foot 8 inch by 6 foot 8 inch opening on the east side of the reactor pool was administratively kept closed because it was not needed during reactor operation and it would have interfered with the operation of the north hot cell and the beam port experiments. However, the usage of this door for equipment during decommissioning is requested. This opening is only 44% of the opening for the main equipment access door onto the beam port floor, on the opposite side of the reactor pool, already controlled administratively under the Technical Specifications.

The applicability of the requirement for the building confinement and its surveillance is proposed until that point during

decommissioning where the removal of radioactive materials from the facility reduces the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building to less than 1.5 x 1 2 times the quantity of materials listed in 10 CFR 30.72, Schedule C. A quantity of radioactive materials 1.5 x I O12 times the quantity of materials listed in 10 CFR 30.72, Schedule C, was selected to account for the difference of the I rem limit in 10 CFR 30.32(i)(1)(i) and the 15 mrem limit for an Unusual Event (the lowest level of emergency for a non-power reactor). This facilitates increased equipment access for subsequent decommissioning activities and vould allow the use of the access hatch from grade level through the beam port floor ceiling the west side of the first floor of the reactor building. This access hatch contains four removable slabs which, when lifted out, provide a 21 1/2 foot by 6 foot opening to the parking area. These removable slabs will be needed to facilitate the removal of large sections of the reactor pool from the reactor building. The 129 square feet of opening provided by these removable slabs is 80% larger than the next largest opening in the reactor building. This also allows for the placement of holes in the roof of the reactor building through which an external crane can lift large items within the reactor building.

Building Exhaust Radiation MNlonitor/Building Exhaust Continuous Air Monitor The building exhaust radiation monitor is a gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum. When the radiation levels measured by this detector exceed I mrem/hr, the building exhaust radiation monitor sounds an alarm in the control room and the building evacuation alarm is actuated. The building exhaust radiation monitor'also scrams the reactor automatically, shuts down the reactor building supply and exhaust fans, and closes the reactor building supply and exhaust dampers.

The goal is to replace the building exhaust radiation monitor with a continuous air monitor which collects particulate discharges in the exhaust from the reactor building. The beta radioactivity collected on the filter paper is measured utilizing a thin window Geiger Mueller tube to measure the beta radioactivity collected on a filter paper. The continuous air monitor is capable of actuating the building or evacuation alarm, shutting down the reactor building supply and exhaust fan, and closing the reactor building supply and exhaust dampers. Until this monitor is installed and operational, the building exhaust radiation monitor will be used.

With the permanent cessation of operations (Amendment 47 dated 29 January 2004) the requirement for an automatic scram to secure the reactor and eliminate the production of radiation is not required. Additionally the providing an alarm in the control room is no longer appropriate as personnel are not usually present in the control room.

A concentration of gamma emitting nuclides of 10- to I0- micro curies per cubic centimeter in the exhaust plenum is estimated to produce a gamma exposure of 1.0 mrem/hr as measured by the Geiger Mueller tube in the building exhaust radiation monitor (taken from the current FNR licensing basis). This building exhaust gamma radiation monitor provides for the automatic protective actions necessary for isolating the reactor building ventilation system as described above.

The new continuous air monitor provides a direct measure ofthe concentration ofparticulate radioactivity being released from the facility through the reactor building exhaust system. This continuous air monitor will actuate the building or evacuation alarm, shut dowvn the reactor building supply and exhaust fan, and close the reactor building supply and exhaust dampers to limit the release of radioactivity from the facility. Except for the control room alarm and the scram initiation signal, the continuous air monitor is functionally equivalent to the existing building exhaust radiation monitor which it will replace and has comparable or better sensitivity.

The minimum emergency level for a non-power reactor requires declaring an Unusual Event for an actual or projected effluent at the site boundary which is measured and could result in a Committed Effective Dose Equivalent of 15 mrem for an exposure of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or less. For radionuclides other than noble gases, Information Notice 97-34, Deficiencies in LicenseeSubmizals Regarding TenninologyforRadiologicalEntergencyAction Levels in Accordance with NewPart 20 provides the methodology for relating measured effluent concentration to committed effective dose equivalent:

100 EC x 24 hr - 15 mrem Applying the 400.dillution factor for releases up the stacks contained within the current license, a concentration of 4 x l0' times the applicable Airborne Effluent Concentration specified in 10 CFR 20, Appendix B, Table 2, Effluent

Concentrations may result in the declaration of an Unusual Event and provides a basis for protective actions.

Note:

Application of the above is for radionuclides other than noble gases. The removal of all reactor fuel and permanent cessation of operations has eliminated noble gases as a source term and has also eliminated radio-iodine as a source of exposure for the thyroid..

As a limiting condition for operation, the building exhaust radiation monitor OR the continuous air monitor shall be operable whenever the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building exceeds the 1.5 x 10 2,tim s the quantities in 10 CFR 30.72, Schedule C-Quantities ofRadioactive Materials Requiring Consideration oftheNeedforan EinergencyPlanforReiponding to a ReleaseAND one or more of the following is open: 1) the reactor building actor building exhaust damper, 3) the beam port exhaust damper to Stack 2, or 4) the room 3103 hood exhaust dampers to 'Stack 2. Additionally, the building evacuation alarm is no longer required once the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building is less than 1.5 x 10.2 times the quantities in 10 CFR 30.72, Schedule C-Quantities of Radioactive Materials Requiring Consideration of the Needfor an Emergency Plan for Responding to a Release

.It is proposed that the building exhaust radiation monitor AND the continuous radiation monitor may be out of service for one week, but no activities which could lead to the' release of radioactivity from the facility may conducted within the reactor building during this period. This allows for repair, calibration or replacement of the instruments during periods where the probability of a release of radioactivity from the facility is minimal.

The applicability of the requirement for the building exhaust radiation monitor or the continuous air monitor shall be maintained until that point where the removal of radioactive materials from the facility reduces the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building to less than 1.5 x 10.2 times the quantity of materials listed in 10 CER 30.72, Schedule. C which 'require an Emergency Plan. The 1.5 x 10.2 times is to account for the difference between the 1 rem limit in 10 CFR 30.(i)(1)(i) and the lower 15 mrem limit for an Unusual Event (the lowest level of emergency for a non-power reactor). Once the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building has been reduced to less than 1.5 x 10.2 times the quantity of materials listed in 10 CFR 30.72, Schedule C, then the removal of the need for the automatic protective actions associated with the reactor building exhaust radiation monitor or the continuous air monitor may be removed. The parallel comes from byproduct material licensee decrease in quantity of radioactive materials below the requirement for an emergency plan. The licensee recognizes that the requirements of 10 CFR20.1301,DoseLimitsforlndividualMemn bers of tlhePublic would continue to apply subject to the allowances of 10 CFR 20.1302, Compliance witl Dose LimitsforIndividual Members of tle Public.

If required to be operational, then the building exhaust radiation monitor shall be calibrated annually (same as in the current technical specifications). The continuous air monitor selfmonitors its performance and actuates a trouble alarm if any parameter falls outside of normal operating characteristics or upon failure of the detectors. The manufacturer recommends that a radiological calibration ofthe instrument should be conducted annually. Ifrequired to be operational, then the building exhaust continuous air monitor shall be calibrated annually to be consistent with the calibration requirements of the building exhaust radiation monitor. It is proposed that when required to be operational, the reactor building exhaust radiation monitor shall be tested quarterly or that if required to be operational, the reactor building exhaust continuous air monitor shall be verified tested quarterly. This periodicity is consistent with the testing of the confinement functions presented in the section above and recommendation of monthly to quarterly from ANSI 15.1 (1990).

The proposed Technical Specifications are:,

3.3 FNR Confinement Applicability:

This specification applies wheneverthe quantity ofradioactive materials in unsealed form, on foils or plated sources, orsealed inglass contained in the reactorbuilding exceeds 1.5 xo1 2 times the quantities in 10 CFR 30.72, Schedule

C - Quantities of Radioactive AMaterials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release.

Objective:

1. To assure that automatic protective action is initiated to limit the release of radioactive effluents from the reactor building when required.
2.

To assure that the FNR reactor building confinement integrity is maintained when required.

Specification

1. Whenever one or more of the following is open: 1) the reactor building supply damper, 2) the reactor building exhaust damper, 3) the beam port exhaust damper to Stack 2, or 4) the room 3103 hood exhaust dampers to Stack 2 THEN:
a.

Gamma Radiation Detector

i.

A gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum shall be operating, ii.

When the radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum indicates a dose rate equal to or greater than I mremfhr, THEN I ) The reactor building ventilation supply and exhaust fans shall automatically turn off;

2)

The reactor building ventilation supply and exhaust dampers shall automatically close;

3)

IF open, THEN the beam port exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required, AND

4)

IF open, THEN the room 3103 hood exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required.

OR

b.

Beta Particulate Continuous Air Monitor

i.

A beta particulate continuous air monitor for the building air exhaust shall be operating.

ii.

When the concentration of radioactive materials measured by the beta particulate continuous air monitor for the building air exhaust is equal to or greater than 4 x 104 times the applicable Airborne Effluent Concentration specified in 10 CFR 20, Appendix B, Table 2, Effluent Concentrations, THEN I ) The reactor building ventilation supply and exhaust fans shall automatically turn off;

2)

The reactor building ventilation supply and exhaust dampers shall automatically close;

3)

IF open, THEN the beam port exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required, AND

4)

IF open, THEN the room 3103 hood exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required.

The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum AND the beta particulate continuous air monitor for the building air exhaust may be out of service, BUT during that period, no activities which could lead to the release of radioactivity from the facility may conducted within the reactor building.

2.

aWhile the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building exceeds 1.5 x 10.2 times the quantities in 10 CFR 30.72, Schedule C, THEN the following conditions shall be administratively controlled:

a.

Personnel access doors will be closed except as necessary for the passage of personnel and/or equipment;

b.

The main equipment access door onto the beam port floor will be opened only long enough to permit the passage of equipment;

c.

The personnel door to the cooling tower area will remain closed except to permit the passage of personnel and/or equipment to the cooling tower area;

d.

The door located on the beam port floor which connects to the Phoenix Memorial Laboratory hot cave operating area will remain closed except to permit the passage of personnel and/or equipment, AND

e.

The access hatch from grade level to the beam port floor AND the personnel exit door located in the north wall of the building will be sealed closed.

Bases:

The potential radiation exposure to persons at the operations boundary following an accident releasing fission products within the confinement building has been evaluated. The evaluation used a leakage rate from the confinement building of 10% of the building volume per day, and concluded that the accident doses would be acceptable.. Conformance to Specifications 3.3.1 and 3.3.2 will assure that the building leak rate will not exceed the leak rate used in the evaluation.

',~ ~ ~~

The 1.0 mremlhr set point for the facility exhaust radiation monitor provides a mechanism for isolating the building ventilation system inthe event ofa significant release ofradioactive material into the reactorbuilding. This setpoint,

..for the detector location involved, represents a gamma emitting nuclide concentration of 10-3 to 10-4 microcuries/cc of building air.

~ ~~.

I The 4.0 x 104 times the applicable Airborne Effluent Concentration specified in 10 CFR 20, Appendix B, Table 2, Effluent Concentrations provides a mechanism for isolating the building ventilation system in the event of a significant release of radioactive material into the reactor building. The 4.0 x 104 factor accounts for the difference the airborne concentration to dose conversion factor (lOOEC x 24 hr = 15 mrem) and the facility specific dilution factor of 400.

By requiring that the access doors and equipment hatch remain closed, except for brief, attended periods to permit personnel or equipment passage, the integrity of the confinement will be maintained at or above the level assumed in the Hazards Summary Report, and the release of radioactive material will be rninimized.

-,{

43 FNR Confinementt.;.

Applicability:

These surveillance requirements apply whenever the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactorbuilding exceeds 1.5 x 10-2 times the quantities in 10 CFR 30.72, Schedule C - Quantities of Radioactive Materials Requiring Consideration of the Needfor an Emergency Plan for Responding to a Release.

Obiective:

1. To assure that automatic protective action is initiated to limit the release of radioactive effluents from the reactor building when required.
2.

To assure that the FNR reactor building confinement integrity is maintained when required.

Specification

1. a.

Gamma Radiation Detector

i.

The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in

the building air exhaust plenum shall be calibrated annually, AND ii.

The ability ofthe radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum to initiate the automatic protective action required by 3.3.1.a.ii shall be tested quarterly.

OR

b.

Beta Particulate Continuous Air Monitor

i.

The beta particulate continuous air monitor for the building air exhaust shall be calibrated annually, AND ii.

The ability of the beta particulate continuous air monitor for the building air exhaust to initiate the automatic protective action required by 3.3.1.b.ii shall be tested quarterly.

2.

The condition of the following gaskets shall be inspected semiannually, and the gaskets shall be replaced whenever any evidence of deterioration is found:

a.

Building ventilation system intake and exhaust dampers;

b.

Personnel access doors;

c.

Equipment access doors;

d.

Cooling tower access door.

Basis The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum has been calibrate annually for most of the operating history of the FNR. This instrument has displayed excellent reliability over many years of operation. The continuous air monitor continuously assesses its performance and actuates a trouble alarm if any parameter falls outside of normal operating characteristics or upon failure of the detectors. The manufacturer recommends that a radiological calibration of the instrument should be conducted annually. The semiannual inspection of the gasket materials has been occurring for most ofthe operating history of the FNR. These materials are not in a damaging environment and semiannual inspection has been found sufficient to assure that the gasket will perform their function of limiting leakage through these openings in the event of a release of airborne radioactivity within the reactor building.

5.3 Reactor Building The reactor building is a windowless, four story, reinforced concrete building with 12 inch walls structurally integral with the footings and foundation mats. The building is approximately 69 feet wide x 68 feet long x 70 feet high with approximately 44 feet exposed above grade. The building has the following general features:

I.

The reactor is housed in a closed room designed to restrict leakage.

2.

The reactor room is equipped with a ventilation system designed to exhaust air or other gases present in the building atmosphere into an exhaust stack which exhausts a minimum of 54 feet above ground level.

3.

The ventilation system provides ventilation for certain storage and experimental facilities and exhausts these a minimum of 54 feet above ground level.

4.

The openings into the reactor building are an equipment access door, three personnel doors, an equipment access hatch, air intake and exhaust ducts, room 3103 fume hood exhaust duct, beam port ventilation duct, a sealed north wall door, a door between the hot cave operating face and the beam port floor, a sealed foundation tile drain to the cold sump, and a pneumatic tube system for sample transfer between the FNR and several laboratories in the Phoenix Memorial Laboratory.

These design features apply until the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building is less than 1.5 x I 02 times the quantities in 10 CFR 30.72, Schedule C - Quantities of Radioactive Materials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release.

Primary Coolant Conditions The limits on conditions for the primary coolant currently contained in the Technical Specification are administrative constraints on operational characteristics adhered to during the operation of the reactor.

The pH and conductivity limits on the primary coolant were to control the corrosion of the aluminum components of the primary cooling system and the fuel element cladding. With the removal of fuel from the Ford Nuclear Reactor (see letter sent to US NRC certifying Permanent Fuel Removal dated December 17, 2003), the removal of the license condition allowing for the possession of reactor fuel under 10CFR70, and the license condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." the limits on pH and conductivity are no longer necessary.

The requirement that all grid positions of the reactor grid contain fuel elements, reflector elements, sample holders or experimental facilities is also no longer necessary as operation of the reactor is not longer allowed by the license condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid."

The surveillance requirement for tracking the makeup water for the reactor pool be maintained to discover significant leakage of water from the facility is being moved to the limiting condition for operation and a surveillance requirement is being added that this record of makeup water be reviewed quarterly. The requirement for a quarterly review of the makeup of water to the reactor pool is sufficiently long enough that pool leaks should be identifiable. This interval is also consistent with the quarterly recommendation for monitoring of pH and conductivity in ANSI 15.1 (1990),

Development of Technical Specif cations for Research Reactors. These requirements would only be applicable when greater than 900 gallons, approximately 6 inches, of water is present in the reactor pool.

The surveillance requirement for monitoring the radioactivity content of the water in the reactor pool was to detect the presence of leaking fuel elements. With the removal of fuel from the Ford Nuclear Reactor (see letter sent to US NRC certifying Permanent Fuel Removal dated December 17, 2003) and the removal of the license condition allowing for the possession ofreactor fuel under I OCFR70 this monitoring is not required. The applicable monitoring ofthe radioactivity in the water from the reactor pool would still be subject to the requirements of specification 3.6, Liquid Effluents if the licensee elects to dispose of the water in the reactor p6ol via the sanitary sewerage system as described in the Decommissioning Plan submitted to the Commission in an earlier license amendment request.

The proposed Technical Specifications are:

3.4 P C-olant ConditiosPzo o l Water Conditions Applicability:

This specification applies to the makeup water added io-the reactor pool while thequantity of water in the reactor pool is greater than 900 gallons.

  • J duI*i.ity, -;dioti, t udfl distri;tit.

Obiective:

Record of the makeup water needs over a period of time allows for the detection of significant pool water leaks.

To Ta.illtait;. the t..

F61a.l coolan it ;.. aCqoditio.. to nti~u.rrin, the CO.,O;i.

offlI~c F.i....j

.7lantrsstell., fuel puecificatsio:

Specification:

1. IF the quantity of water contained in the reactor pool is greater than 900 gallons, THEN a record of the

.t I - -

makeup water added to the reactor pool shall be maintained.

1.

T.c Pi.;..,.y cooli.t,H shall b1 e niintainHcd betn..

4.5 a..d 7.5.

2.

TIM Pli.;...ay uool.at cond

tc ti 3 1i 1 sab niaintaincd at a lic Icss 5li"..

.icoiun.lo,'c... exct for pciiu 3s ofti;,c not to exceed 7 daas Mulztlt.c.oductivity tiy not be. gctc than 20 nic1onluokn..

3.

Fuz UPC! tir at Po MC 3l ;C CIS irl CXCCZS of 100 k\\V ;i tlc fo. ccconlvec tion.odc, all id puositio s shl1ll Mftir;l ftlcl CIMC11staS.C.lCCtoL.Ic...c.ts, samp.le loldcts, o. expezinienc.tal. cilitics..

Bases:

Record ofthe makeup waterneeds over a period oftime allows for the detection ofsignificantpool water leaks.

Expe,. inc..c at tl.;s and otlhc. ff.;lities hns slhou. tl.>t tlh.nif.titc..MI.. co fp. im.ar y coolalit Sy>stc... -3tc. qualito

tl.c.angs 1cificd ; SpecificationaZ.

3.4.1 and 3.4.2 'l!

1CoMMl tlhc.oL.OALolL oftl.c 3IUiUlitl CuIoMPuo c ts of tlhc ^.i..ary cool..t sastc.rt and tlie fuel clenc..c.t claddin..6 Specificatii.n 3.4.3 tl,>t nil g.;J positions bc o~ct.pid -nil! pev-et tlhc degr..dtion, of flov.p zatca 'due to flw bypsaa~ssi tlsc acti% c fitclcl, -

o l.ogl. nit t.,occtipi.d t riplatc Position.

4.4 Primary Coolant System Applicability:

This specification applies to the makeup water added to the reactor pool while the quantity of water in the reactor pool is greater than 900 gallons Tli;s speif..aion. applies to tl.c. ti.;llcc ftlu.c pti. nm.ry.oo..lt sy3tc1.

Obiective:

Reviewofthe makeup waterneeds overa period of time allows forthe detection of significantpool water leaks.

To assune l.gl qualit) pool %a-tc an.d to detect tlc ICJs of ffi3iu pJoducts fT0111 fucl clcMIut.

Specification:

1.

IF the quantity of water contained in the reactor pool is greater than 900 gallons, THEN the quantity of makeup water added to the reactor pool shall be reviewed quarterly.

1. Tlhc jI 1

of tl.. puilhiay coola.t 31ha11 bc 1=.33MLd H cckly.

..T.c co..duc ti aty of.. t,....im.y coolant. sa!al be n..casuced ueckly-3.

Tlhc i dioac ti tity co..tc..t o f t].c pi.;in.a.. cool..t shlall be...casuited bin-ccekly.

Bases:

A small portion of the pool structure is in direct contact with the soil under the reactor building. Routine inspection of the makeup water records over a period of time provides early warning of significant pool leaks.

Rcgt3lU1 su. lV

.cc of poF l nvatl.. qL uality a 1d tadicactivity pi.uv;ics assuri...c tLlUt pH..nd co..ducti.it.

chan.ges tlat could acceclatc tl.C COL.03i01. oftlhc P.in..Y coolast systcrn. ouill lbc dctcctcd beforc a~signfcant COILOai%

a an-getotldoccut andu tlrat relitescwaic of *wleaki

uwry, f

lwl 111LAS illl tCL=tVI is detectcd.

Radiation Monitoring The facility has three area radiation monitors which measure the general gamma radiation levels on the west side of the beam port floor, the north side of the beam port floor and the east side of the beam port floor. Each of these area radiation monitors provide's local indication of the radiation level and provides a local alarm whenever the measured radiation level exceeds a set point'established by the management of the facility subject to a maximum set point specified in the Technical Specifications. Each of thege area monitors'also provides a recorded signal to the control room which allows the operator to monitor radiation levels throughout the beam port floor. These monitors were intended to notify personnel on the beam port floor and the reactor operator of a significant change in the radiation emitted from any of the ten (10) six inch diameter or two 8 inch diameter penetrations through the biological shield while the reactor was operating.' With thle permanent cessation of operation and the removal of all reactor fuel, the levels of radiation which can be produced from these beam ports has been substantially reduced. Recent experience from the unloading of collimators from the beam ports after permanent cessation of operation and the removal ofall reactor fuel found that the r'adiation levels emitted from a fully open beani port in-6n the order of a few I Os of milli Rem directly at the beam port opening from the biological shield. These radiation'levels w6uld generally riot be detectable by the three area monitors on the beam port floor. It is proposed that the requirements for the three area radiation monitors on the beam port floor be removed from the Technical Specifications.

The facilityhas an area radiation monitor whichmeasures the general gamma radiation levels on the reactorbridge. This area radiation monitors provides local indication ofthe radiation level and provides a local alarm whenever the measured radiation level exceeds a set point established by the management ofthe facility subject to a maximum set point specified in the Technical Specifications. The area monitor on the reactor bridge also provides a recorded signal to the control room which allows the operator to monitor radiation levels throughout the facility. Due to the possibility of elevated levels of general area radiation from the irradiated materials being stored in the reactor pool, the reactor bridge area radiation monitor is being maintained in the Technical Specificati6ns'biit would only be required to be operational when radiation levels from radioactive materials could produce radiation levels in accessible areas in excess of 100 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 centimeters (consistent with the requirement for a High Radiation Area in I OCFR20). The removal of the requirement that the signal from the reactor bridge area monitor be recorded in the control room is requested as the control room is not normally occupied and neither provides protective features nor initiates corrective action necessary to protect the health and safety of the public. Currently the Technical Specification Limiting Conditions for Operations requirements for area monitoring are contained in Section 3.2, Reactor Safety System. It is proposed that the requirements for'the area monitors be combined with the requirement in Section 3.5, Airborne Effluents and that this section be renamed Radiation Monitoring. This is consistent with the guidance provided in ANSI 15.1 (1990),

Development of Technical Specflcationsfor Research Reactors.

The facility currently has two gaseous activity detector systems which monitor the level of gaseous radioactivity from the reactor facility during reactor operation. With the removal of all irradiated fuel from the facility in the Fall of 2003 (see letter sent to US NRC certifying Permanent Fuel Removal'dated December 17, 2003) and the current license condition: "Maximum Power Level: The licerisee shall not operate the reactor nor place fuel elements in the reactor grid." (January 29, 2004 license for the Ford Nuclear Reactor) radioactive gases such as argon-41 no longer exist and can no longer be generated as fission products 'or nieutron activation products at the facility. Therefore, the requirement for the gaseous activity detector systems can be reemoved without decreasing the safety of the facility. It is requested that the limiting condition for operation and the surveillance requirements for the gaseous activity detectors be removed from the Technical Specifications.

The facility currently has two airborne particulate monitors which monitor the concentration of airborne radioactive materials on the pool floor and the beam port floor. Currently only the pool floor airborne radioactive particulate monitor is required by the Technical Specifications, as the'reactor pool presented the highest probable source of high levels of airborne radioactive materials during reactor operation, particularly from the failure of an experiment or the failure of a fuel element. The airborne particulate monitor on 'the beamipoit floor is being added to the Technical Specifications to facilitate the removal of the Stack 2 mobile air particulate monitor, discussed below. These airborne particulate monitors would be required to be operational'during licensed activities which could lead to the generation of airborne radioactivity exceeding 1% of the applicable concentrations specified in I OCFR20, Appendix B, Table 1, Column 3, Derived Air Concentration (DAC).

The reactor building was designed to restrict leakage and is equipped with a general ventilation system that provides the primary heating for the building and exhausts through a stack on the roof. A smaller exhaust ventilation system in the reactor building is also connected to a laboratory exhaust stack in the contiguous Phoenix Memorial Laboratory (PML),

Stack 2.

A signal from the building exhaust radiation monitoring system can close dampers in the primary air system supply and exhaust ducts as well as dampers in the smaller ventilation system connected to the laboratory exhaust stack in PML. The smaller ventilation system draws air from the pneumatic tube system blower and the fume hood in room 3103 in the reactor building which contains the pneumatic tube system loading and unloading station. When the reactor was operating, a failure of an experiment in the pneumatic tube system had the potential to produce high levels of radioactive effluent from the smaller ventilation system connected to the laboratory exhaust stack in PML. A mobile air particulate monitor was required by the Technical Specifications to monitor this effluent and provide an indication to the operator in the control room so that the necessary corrective action could be taken upon the detection of a high level of radioactive effluent from the smaller ventilation system connected to the laboratory exhaust stack in PML. The permanent caseation of the operation of the reactor has eliminated the pneumatic tube system as a source for a high level of radioactive effluent from the smaller ventilation system connected to the laboratory exhaust stack in PML. The only source of radioactive effluent to the smaller ventilation system is the already monitored volume of the reactor building.

The airborne radioactivity in the reactor building is monitored by the reactor building exhaust radiation monitoring system which provides automatic action to isolate the smaller ventilation system connected to the laboratory exhaust stack in PML. This reactor building exhaust radiation monitoring system is covered by the Technical Specifications associated with FNR Confinement (discussed below). The monitoring of the particulate airborne radioactivity in the smaller ventilation system connected to the laboratory exhaust stack in PML is redundant and the system can be removed. It is requested that the limiting conditions for operation and the surveillance requirements associated with the Stack 2 mobile particulate monitor be removed from the Technical Specifications.

To facilitate this change, some deletions from the Technical Specification 3.2 are required:

3.2 Reactor Safety System Applicabilitv:

These specifications apply to the reactor safety system and other safety related instrumnentation.

Objective:

To specify the lowest acceptable level ofperformnance or the mninimumn number of acceptable componentsfor the reactor safety system and other safety related instnumentation.

Snecification:

The reactor shall not be made critical tunless:

1 Tlhereactorsafety'systemsandsafetyrelated instnunentation are operable in accordance tith Tables 3.1 and 3.2 including the mininuan number of channels and the indicated maximum or minimum setpoints; Bases:

T-Im use of tlh a.. zadi;ation munto ;t systc n.. asstize theat a....s of tlhc ffcilit3 i;..hi... a^I;l hi;gh tadIation....

could cxist at. niontot. e.

Table 3.2 REQUIRED SAFETY RELA TED INSTRUMENTI TION Afinimnumn Numnber InstrunientatiOn Setpoint Required Function

FaciiyRadaton

2. Retor DB;idg.

40(50)1b mcL.

c 1r 1.

m.

3 M'Cou....,.20(.0)b

!,C

  1. 1Aarms B

eamor '

.o

4.

N Wdll, DBijuLL,.

C(t0)L r

riqli

-i Ala Floor

5.

NE C-0 l=11,.

n)ble.

Footnotes:

t........

aldir SL..d a

C t1 L.Uhl A I..TIc,.

tl.;s sys te'l 3

t C sho% s. Tlnc a P*

I.l.fl.

1.

dc lrg Ob 6al c diiioiis. Uv ofi

. l atpOftill icjui apGal of tl.c lca R'a"t.L Lab Oat,.Osk')fia!6a OI OofC AssiStft

?Vlftnak;CI.

Any IsCtFOL MUaf ssssss~

ssa dt a.~

stPos O0C a

h sssa

~l

c.

Ifrd;i;t ad;I; u zit,

., 4

s.

ld out oc-c fL a pC iod of tlAn 7 d

Lda s ieaz.,cto.

hut d on OL thet 241itOL al~ll iaJ l;y a Manning trnt ofs 5;r rlat ian. IhOula SCCOsid of thmes nisonisutv bRC placed ou fS 4vCstlcsah

-1 be slult donn t uissC1 the *nionitor is lettITL~d tO v siCc ni-;tfin2 4hIotts, or is acplaccdb1o^ asctscid10oali alassssss airit of sintlat MLssgC.

The proposed Technical Specifications are:

3.5 Radiation Monitoring A1i bot.. Effluents Applicability:

This specification applies to the monitoring of effluent releases from the Ford Nuclear Reactor, area radiation levels within the reactor building, and particulate airborne activity within the reactor building.

Obiective:

To assure that the release of airborne radioactive material from the Ford Nuclear Reactor is maintained below the limits established in IOCFR20 and to ensure that occupational exposures are controlled as established in 10CFR20.

Specification:

1. The concentration ofradioactive materials in the effluent released from the facility exhaust stacks shall not exceed 400 times the concentrations specified in I OCFR20, Appendix B, Table 2, Column 1, Air Effluent Concentration (AEC), averaged over time periods permitted by I OCFR20.
2.

During opetatio of tlie teacto licensed activities which could lead to the generation of airborne radioactivity exceeding 1% of the applicable concentrations specified in I OCFR20, Appendix B, Table 1, Column 3, Derived Air Concentration (DAC), the following conditions shall be met:

a.

The...olilc ah patticulate... ot and fle gascuUts :ztvit) dtecto, fbL tU. Stack 2 c slvall l.

uoc.at;ig. Ifsltl1 u1 1 t s o o s c f.

t 24 ho h

tlt a

3lall lc I o

o, tl.c u..;t shall..

bejplac%.d ly O TIP of c..abic Arion1tm; capabilih

a.

An air particulate monitor shall be operating on or near the pool floor. Thl MaCtAl jool fluOO mobile Mil P3 tiCtla~tC 111011itOL assed the gascotis activ ity detecto. fbL diec LeaCto, btrildig,g ecxhattst s>tackc slial!

bec opecrt;ing. If ciflir tinsitia,;S ot of sc, vice fo. m.orc dians 24 lhous, cidtc. tlic *Cactot shsall beC Hi ni ha be.=te y n fonaabeaottzigcpblt-;

c.

I hr...

ebttd1J e~dAih at 321 iIt'.)lAl....

o tu, stl y l be OPCnt1 C I HIC I t 1c Ill U

Lic c..,

.tS 1 1 u;.i 1 d by Table 3.2 of specfi.tion 3.2.

b.

An air particulate monitor shall be operating on the first floor.

If an air particulate monitor required by above is found to be not operable or is taken out of service, then licensed activities which could lead to the generation of airborne radioactivity exceeding 1% of the applicable concentrations specified in IOCFR20, Appendix B, Table 1, Column 3, Derived Air Concentration (DAC), shall be stopped in a safe condition and shall not resume until the air particulate monitor is restored to operating.

Note:

Thie liniting conditions for operation associated itll, the building exhia ust radiation monitor hate been novled to 3.3 FNR Confinement as tescribe(d in another section of this Techlnical Specification Anendment.

3.

Area Radiation Monitors:

a.

Licensed activity involving radioactive materials that could produce radiation levels in areas accessible to individuals in excess of 100 mrem in I hour at 30 centimeters (measured from an accessible surface that emits radiation) shall not be performed on the pool floor unless an operating area radiation monitor which measures the general gamma radiation level and provides a local alarm at or below 50 mrem/hr is located on the third floor near the reactor pool.

If a local area radiation monitor required above is found to be not operable or is taken out of service, then licensed activity involving radioactive materials that could produce radiation levels in areas accessible to individuals in excess of 100 mrem in I hour at 30 centimeters (measured from an accessible surface that emits radiation) shall be stopped in a safe condition and shall not resume until the affected local area radiation monitor is restored to an operating condition.

Bases:

The limits established in this specification incorporate a dilution factor of 400 for effluents released through the exhaust stacks. This dilution factor was calculated from actual FNR site meteorological data and represents the lowest dispersion factor determined and the highest frequency of wind in any sector. Because of the use of the most conservative measured values of wind directional frequency and dispersion factors, this dilution factor will assure that concentrations of radioactive material in unrestricted areas around the FNR site will be far below the limits of IOCFR20.

The pool floor area radiation monitor provides local indication of elevated levels of radiation from the irradiated materials in the reactor pool.

The requirements of this specification are considered adequate to assure proper monitoring of area radiation and airborne radioactivity levels within the reactor building.

4.2 Reactor Safety System Alpplicahility:

This speciflcation applies to the surveillance of tire reactor safety system.

Obiective:

To assure that the reactor safety system is operable as required by Specification 3.2.

Specification:

4.......... o t.

dLt iI...oto.;

gyst%..

u;.c ;

.Tbl 3.2 sl.. bjfic.

.a.

HUI. to earl. i=&L'to.

tt~lp fb!!U'ni!!

n P-Liod nhc.n the m.ctoz nAv seetticd,

b.

AttLc a d annetl has bcc.n Icc.nc.g;cdz

c.

Ifa cltiel lias be.,. tepa.c.d, auL c..

1 patio, and setp.oi.nt v.. ifi.ation ai ill bL pfbm..d Fj.;

to We1.

5.

n_ Liatio i

3)z~tl

&..tjiI.d fiz Tabl. 3.2 sl1.!1 be. caUlibUted s1ri.1maull)

Bases:

.. l LaJL..t...........

Rad;tio...o ;o~sare check~cdfb pope...

op c o ctio Aefication...

4.2.14.

C-alibintion and setpoint tcification i.volce use of a caliblvto.-.

-'u CC lt sgsib.. cant petslonxil tadiation cxposur.

Scrifiatuital calibratio n of1tadiation 1111Jit0L3, vNlUI..li L

di1splaj..J cxeclle.nt stability mc... a..y ymais of o.platio.., is adequate to rctfy fIhC Set Hoillt tn~iC33 ;.

Mt.=.c..

C iatmb CCLC IJC lm..-de.

t.. t 4.5 Radiation Monitoring Ail bot nI Effluents Applicability:

This specification applies to the surveillance of the monitoring equipment used to measure area gamma levels and airborne radioactivity.

Obiective:

The objective is to assure that accurate assessment of area gamma levels and airborne radioactivity is available during the conduct of licensed activities.

Specification:

1.

l li,..

building cx st >; 1AdiatiOn 1

1110 1 o1t.1 shall be caIlbLated seLmiannually.

Note:

Thtesurveillance requirements associated vith the buildingexlxa ust radiation monitorhave been moved to 4.3, FNR Confinement as described in another section of this Technical Specification Amendment.

2.

Air Particulate Monitors

a.

The air particulate monitors shall be calibrated semiannually.

b.

The operation of the air particulate monitors shall be checked daily when the reactor staff is present in the facility.

c.

An air particulate monitor shall be calibrated upon replacement or following maintenance which could affect calibration.

3. nie gascous activ ity det)cto s alti be1 calibated flb A16.- 41 senuiannfall)-
3. Area Radiation Monitors:
a.

The area radiation monitors shall be calibrated semiannually.

b.

The area radiation monitors shall be channel checked monthly.

c.

An area radiation monitor shall be calibrated and a channel check shall be performed upon replacement or following maintenance which could affect the calibration.

These surveillance requirements shall be met during the conditions specified in the Limiting Condition for Operation. Surveillances do not have to be performed on inoperable equipment.

Bases:

The Ford Nuclear has upgraded to the Eberline AMS4 for the air particulate monitors: The AMS4 continuously monitors all critical operating parameters of the unit, such as air flow, detector response, etc., and generates a local alarm whenever one of the monitored parameter falls outside the operator established range.

The AMS-4 has several years of demonstrated reliable performance in the power reactor community. The surveillance intervals provided for the air particulate monitors are sufficient to ensure the operability of the air particulate monitors between surveillance intervals.

Semiannual calibration of radiation monitors, which have displayed excellent stability over many years of operation, is adequate to verify the set point unless instrument repairs have been made.

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 1.0 DEFINITIONS Channel Calibration - A channel calibration is an adjustment of the channel such that its output corresponds with acceptable accuracy to known values of the parameter which the channel measures. Calibration shall encompass the entire channel, including equipment actuation, alarm, and trip, and shall be deemed to include the channel test.

Channel Check - A channel check is a qualitative verification of acceptable performance by observation of channel behavior. This verification where possible shall include comparison of the channel with other independent channels or systems measuring the same variable.

Channel Test - A channel test is the introduction of a signal into the channel to verify that it is operating.

Experiment - An experiment, as used herein, is any of the following:

1.

An activity utilizing the reactor system or its components or the neutrons or radiation generated therein;

2.

An evaluation or test of a reactor system operation, surveillance, or maintenance technique;

3.

An experimental or testing activity which is conducted within the confinement or containment system of the reactor;

4.

The material content of any of the foregoing, including structural components, encapsulation or confining boundaries, and contained fluids or solids.

Experimental Facility - An experimental facility is any structure or device which is intended to guide, orient, position, manipulate, or otherwise facilitate a multiplicity of experiments of similar character.

Explosive Material - Explosive material is any solid or liquid which is categorized as a

severe, dangerous, or very dangerous explosion hazard in DANGEROUS PROPERTIES OF INDUSTRIAL MATERIALS by N.I. Sax, Third Ed. (1968), or is given an Identification of Reactivity (Stability) Index of 2,3, or 4 by the National Fire Protection Association in its publication 704-M, 1966.

Limiting Conditions for Operation (LCO) -

Lowest functional capability or performance levels of equipment required for safe operation of the reactor (1 OCFR50.36).

Limiting Safety System Setting (LSSS) - Settings for automatic protective devices related to those variables having significant safety functions, and chosen so that automatic protective action will correct an abnormal situation before a safety limit is exceeded (10CFR50.36).

Measured Value - The measured value of a process variable is the value of the variable as indicated by a measuring channel.

Measuring Channel - A measuring channel is the combination of sensor, amplifiers, and output devices which are used for the purpose of measuring the value of a process variable.

Moveable Experiment - A moveable experiment is one which may be inserted, removed, or manipulated while the reactor is critical.

Page 1

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Operable - Operable means that a component or system is capable of performing its intended function in its normal manner.

Operating - Operating means that a component or system is performing its intended function in its normal manner.

Potential Reactivity Worth of an Experiment - The potential reactivity worth of an experiment is the maximum absolute value of the reactivity change that would occur as a result of intended or anticipated changes or credible malfunctions that alter equipment position or configuration.

Reactivity Limits - The reactivity limits are those limits imposed on reactor core excess reactivity. Quantities are referenced specifically to a cold core (nominally 90 OF) with the effect of xenon poisoning on core reactivity accounted for if greater than or equal to 0.05% AK/K. The reference core condition will be known as the cold, xenon free critical condition.

Reactor Operation - Reactor operation means that the control rods installed in the core are not fully inserted or that the control console key is in the keyswitch.

Reactor operation is not considered possible when there are less than six standard fuel elements in addition to the four control elements that house the control rods on the grid plate.

Reactor Safety System - The reactor safety system is that combination of safety channels and associated circuitry which forms the automatic protective system for the reactor or provides information which requires manual protective action to be initiated.

Reactor Scram - Shutoff of electrical current to the rod holding magnets and subsequent insertion of the rods into the core by gravity.

Reactor Secured - Reactor Secured is defined as follows:

1.

The full insertion of all control rods has been verified;

2.

The control console key is removed; and

3.

No operation is in progress which involves moving fuel elements to or from the core, moving reflector elements to or from the core, the insertion, or removal of secured experiments from the core, or control rod maintenance.

Readily Available on Call - Readily available on call shall mean that an individual can be contacted and is within a reasonable driving time (1/2 hour) from the reactor building.

Regulating Rod - The regulating rod is a control rod of low reactivity worth fabricated from stainless steel and used to control reactor power. The rod may be controlled by the operator with a manual switch or by an automatic controller.

Removable Experiment - A removable experiment is any experiment, experimental facility, or component of an experiment, other than a permanently attached appurtenance to the reactor system, which can reasonably be anticipated to be moved one or more times during the life of the reactor.

Page 2

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Reportable Occurrence -A reportable occurrence is any of the following:

1.

A safety system setting less conservative than the. limiting setting established in the Technical Specifications;

2.

Operation in violation of a limiting condition for operation established in the Technical Specifications;

3.

A safety system component malfunction or other component or system malfunction which could,; or.. threatens to, render the safety system incapable of performing its intended safety functions;

4.

Release of fission products from a failed fuel element;.

5.

An uncontrolled or unplanned'release of radioactive material from the restricted area of the facility;

6.

An uncontrolled or unplanned release 'of radioactive material which results in concentrations of radioactive materials within the restricted area in, excess of the limits' specified in Appendix B, Table 1, Column 3, Derived Air Concentration (DAC) of I OCFR20;

7.

An uncontrolled or unanticipated change in reactivity in excess of 0.005 AK/K;

8.

Conditions arising from natural or man made events that affect or threaten to affect the safe operation of the facility;

9.

An observed inadequacy, in the implementation of administrative or procedural controls such that the inadequacy causes or threatens to cause the existence or development of an unsafe condition in connection with the operation of the facility.'

Rundown - A rundown is the automatic insertion of the shim safety rods.

Safety Channel - A safety channel is a measuring channel in the reactor safety system.

Safety Limit (SL) - Limits upon important'process variables which are found to be necessary to reasonably protect the integrity of certain of the physical barriers that guard against the uncontrolled 'release of radioactivity (1 OCFR50.36).

Secured Experiment - Any experiment, experimental facility, or component of an experiment is deemed to be secured,- or in a secured position, if it is held in a stationary position relative to the reactor by meichanical means. The restraint shall exert sufficient force on the experiment to overcome the -expected effects of hydraulic, pneumatic, buoyant, or other forces, which are normal to the operating environment of the experiment, or of forces which might'arise as a result of credible malfunctions.

Shim-Safety Rod - A shim-safety rod is a control rod fabricated from either borated stainless steel or a boron-aluminum alloy which is used to compensate for fuel burnup, temperature, and poison effects.%.A shim safety rod is magnetically coupled to its drive unit allowing it to perform the function of a safety rod when the magnet is deenergized.

Static Reactivity Worth - The static reactivity worth of an experiment is the absolute value of the reactivity change which is measurable by calibrated control rod comparison methods between' two defined terminal positions or configurations of the experiment.

For moveable experiments, the terminal positions are fully removed from the reactor and fully inserted or installed in the normal functioning or intended position.

.,P.,Pqge 3

-A---

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Time Intervals - The average over any extended period for each surveillance time interval shall be closer to the normal surveillance time than the extended time. Any extension of these intervals shall be occasional and for a valid reason, and shall not affect the average as defined.

Annually - 12 to 15 months.

Biannually - 24 to 30 months.

Biweekly - 14 to 20 days.

Daily - 24 to 32 hours3.703704e-4 days <br />0.00889 hours <br />5.291005e-5 weeks <br />1.2176e-5 months <br />.

Monthly - 30 to 40 days.

Quarterly - 3 to 4 months.

Semiannually - 6 to 8 months.

Weekly - 7 to 10 days.

True Value - The true value of a process variable is its actual value at any instant.

Unscheduled Shutdown - An unscheduled shutdown is defined as any unplanned shutdown of the reactor caused by actuation of the reactor safety system, operator error, equipment malfunction, or a manual shutdown in response to conditions which could adversely affect safe operation, not to include shutdowns which occur during testing or checkout operations.

2.0 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS 2.1 Safety Limits Applicability As the Safety Limits were for the protection of the cladding integrity of the reactor fuel during reactor operation, all safety limits have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under 10CFR70 was removed.

2.2 Limiting Safety System Settings (LSSS)

Applicability As the Limiting Safety System Settings were for the protection of the cladding integrity of the reactor fuel during reactor operation, all limiting safety system settings have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under 10CFR70 was removed.

Page 4

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX) MMM YYYY 3.0 LIMITING CONDITIONS FOR OPERATION 3.1 Reactivity Limits Applicability:

The reactivity limits applied to the reactivity of the reactor core, the reactivity worths of the control rods, and the reactivity of experiments to ensure that the reactor could be controlled and shutdown at all times and to ensure that the safety limits contained in the Technical Specification could not be exceeded.

Reactivity limits have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level:' The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor-fuel under 1 OCFR70 was removed.

3.2 Reactor Safety System' Applicability:

These specifications applid to' the. reactor, safety system and other safety related instrumentation. The Reactor Safety System requirements have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under 1 OCFR70 was removed.

The area radiation-monitorisystem has been moved to Limiting Condition for Operation 3.5, Radiation Monitoring.

The facility radiation exhaust monitor has been moved to Limiting Condition for Operation 3.3, Confinement.

3.3 FNR Confinement Applicability:

This specification applies to the'major openings in the Ford Nuclear Reactor building, the confinement dampers in the general building. exhaust, and the confinement dampers in the smaller exhaust connection to the Phoenix Memorial Laboratory laboratory exhaust (Stack 2).

This specification applies whenever the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass.contained in the reactor building exceeds 1.5 x10' times the quantities'in 10CFR30.72, Schedule C - Quantities of Radioactive Materials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Obiective:

1.

To assure that automatic protective action is initiated to limit the release of radioactive effluents from the reactor building when required.

2.

To assure that the FNR reactor building confinement integrity is maintained when required.

Specification:

1.

Whenever one or more of the following is open: 1) the reactor building supply damper, 2) the reactor building exhaust damper, 3) the beam port exhaust damper to Stack 2, or 4) the room 3103 hood exhaust dampers to Stack 2 THEN:

a.

Gamma Radiation Detector

i.

A gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum shall be operating, ii.

When the radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum indicates a dose rate equal to or greater than 1 mrem/hr, THEN

1)

The reactor building ventilation supply and exhaust fans shall automatically turn off;

2)

The reactor building ventilation supply and exhaust dampers shall automatically close;

3)

IF open, THEN the beam port exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required, AND

4)

IF open, THEN the room 3103 hood exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required.

OR

b.

Beta Particulate Continuous Air Monitor

i.

A beta particulate continuous air monitor for the building air exhaust shall be operating.

ii.

When the concentration of radioactive materials measured by the beta particulate continuous air monitor for the building air exhaust is equal to or greater than 4 x 104 times the applicable Airborne Effluent Concentration specified in 10CFR20, Appendix B, Table 2, Effluent Concentrations, THEN

1)

The reactor building ventilation supply and exhaust fans shall automatically turn off;

2)

The reactor building ventilation supply and exhaust dampers shall automatically close;

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX) MMM YYYY

3)

IF open, THEN the beam port exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required, AND

.4)

IF open, THEN the room 3103 hood exhaust damper to Stack 2 shall automatically close OR IF the penetration through the reactor building wall is mechanically sealed, THEN no action is required.

The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation"level in the building air exhaust plenum AND the beta particulate continuous air monitor for the building air exhaust may be out of service, BUT during that.period, no activities which could lead to the release of radioactivity from the facility'may conducted within the reactor building.

2.

While the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building exceeds 1.5 x 10-2 times.the quantities in 10CFR30.72, Schedule C, THEN the fdllowing conditions shall be administratively controlled:

a.

Personnel access doors will be closed except as necessary for the passage of personnel and/or equipment;

b.

The main equipment'access door onto the beam port floor will be opened only long enough to permit the passage of equipment;

c.

The personnel door to the cooling tower area will remain closed except to permit the passage of personnel and/or equipment to the cooling tower area; "d.'

The door located on the beam port floor which connects to the Phoenix Memorial' Laboratory hot cave operating area will remain closed except to permit the passage of personnel and/or equipment, AND

e.

The access hatch fromr'radelevel to the beam port floor AND the personnel exit door'locateddin the north wall of the building will be sealed closed.

Bases:

The potential radiation exposure to persons at the operations boundary following an accident releasing fission products within -the confinement building has been evaluated. 'The' evaluation used a leakage rate'from the confinement building of 10% of the'building volume-per day, and concluded that-the accident doses would be acceptable. Conformance to Specifications 3.3.1 and 3.3.2 will assure that the building leak rate will not exceed'the leak rate used in the evaluation.

The 1.0 mremlhr setpoint for the facility exhaust radiation monitor provides a mechanism for isolating' the building ventilation system in the event of a significant release of radioactive'imaterial into the reactor building. This setpoint,

)

lo,,;

a,

t'ag,7

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY for the detector location involved, represents a gamma emitting nuclide concentration of 10-3 to 104 microcuries/cc of building air.

The 4.0 x 10 4 times the applicable Airborne Effluent Concentration specified in 10CFR20, Appendix B, Table 2, Effluent Concentrations provides a mechanism for isolating the building ventilation system in the event of a significant release of radioactive material into the reactor building. The 4.0 x 10 4 factor accounts for the difference the airborne concentration to dose conversion factor (100EC x 24 hr = 15 mrem) and the facility specific dilution factor of 400.

??

By requiring that the access doors and equipment hatch remain closed, except for brief, attended periods to permit personnel or equipment passage, the integrity of the confinement will be maintained at or above the level assumed in the Hazards Summary Report, and the release of radioactive material will be minimized.

3.4 Primary Coolant Conditions Applicabilitv:

This specification applies to the makeup water added to the reactor pool while the quantity of water in the pool is greater than 900 gallons.

Obiective:

Record of the makeup water needs over a period of time allows for the detection of significant pool water leaks.

Specification:

1.

IF the quantity of water contained in the reactor pool is greater than 900 gallons, THEN a record of the makeup water added to the reactor pools

??

shall be maintained.

Bases:

Record of the makeup water needs over a period of time allows for the detection of significant pool water leaks.

3.5 Radiation Monitoring Applicability:

This specification applies to the monitoring of airborne effluents from the Ford Nuclear Reactor, area radiation levels within the reactor building, and particulate airborne activity within the reactor building.

Obiective:

To assure that the release of airborne radioactive material from the Ford Nuclear Reactor is maintained below the limits established in 10CFR20 and to ensure I that occupational exposures are controlled as established in 10CFR20.

??

Pa'g 8

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS

'Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Specification:

1.

The concentration of radioactive materials in the effluent released from the facility exhaust stacks shall not exceed 400 times the concentrations specified in 1 OCFR20, Appendix B, Table 2, Column* 1, Air Effluent Concentration (EAC), averaged over time periods permitted by 1 OCFR20.

2.

During license activities'which could lead to the generation of airborne radioactivity exceeding 1% of the applicable concentrations specified in 10CFR20, Appendix. B, Table. 1, Column 3, Derived Air Concentration (DAC),.the following conditions shall be met:'

a.

An air particulate monitor shall be operating on or near the pool

'floor.

b.

An air paarticulate monitor shall be operating on the first floor.

If an air particulate monitor required by above is found to be not operable or is taken out of service, then licensed activities which could lead to the generation of airborne radioactivity exceeding 1% of the applicable concentrations specified in 10CFR20, Appendix B, Table 1, Column 3, Derived Air Concentration (DAC),

shall be stopped in a safe condition and shall not resume until the air particulate monitor is restored to operating;.

3.

Area Radiation Monitors:'

a.

Licensed activity involving radioactive materials that could produce radiation levels in areas accessible to individuals in excess of 100 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 centimeters (measured from an accessible surfac6 that emits radiation) shall not be performed on the pool floor unless an operating area radiation monitor which measures the general gamma radiation level and provides a local alarm at or below 50 mrem/hr is located on the third floor near the reactor pool.

If a local area radiation monitor required'aboveis' found to be not operable or is taken out of service, then licensed activity involving radioactive materials that could produce radiation levels in areas accessible to individuals in excess of 100 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 centimeters (measured from an accessible surface that emits radiation) shall be stopped in a safe condition and shall not resume until

??

the affected local area radiation monitor is restored to an operating condition.

Bases:

The limits established in this specification incorporate a dilution factor of 400 for effluents released through the exhaust stacks... This dilution factor was calculated from actual FNR site meteorological data and represents the lowest dispersion factor determined and the highest;frequency of wind in any sector.

Because of the use of the most conservative measured values of wind directional frequency and dispersion factors,. this, dilution factor will assure that concentrations of radioactive material in unrestricted areas.around the FNR site will be far below the limits of 10CFR20.

The pool floor area radiation monitor provides local indication of elevated levels of radiation from the irradiated materials in the.reactor pool.

??

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY The requirements of this specification are considered adequate to assure proper monitoring of area radiation and airborne radioactivity levels within the reactor building.

3.6 Liquid Effluents Applicability:

This specification applies to the monitoring of radioactive liquid effluents from the FNR.

Obiectives:

The objective is to assure that exposure to the public resulting from the release of liquid effluents will be minimized.

Specification:

1.

The concentration of radioactive materials in the effluent released from the facility liquid waste system to the city of Ann Arbor sanitary sewer system shall be readily soluble (or readily dispersible biological material) in water and shall not exceed 315 times the concentrations specified in 10CFR20, Appendix B, Table 3, Releases to Sewers.

2.

The amount of liquid discharged shall be limited to the equivalent of 3,000 gallons of liquid at the concentration limit specified in 3.6.1 each day.

3.

Liquids from the facility's radioactive liquid waste system shall not be discharged into the storm drain system.

Bases:

All radioactive liquid effluents are collected in a series of three, 3,000 gallon, coated, steel retention tanks, and they are normally recycled to the reactor pool to make up for surface evaporation.

However, after sampling, analysis, and dilution, if the concentration of radioactivity is less than the limit of 10CFR20, liquid effluents can be discharged to the sanitary sewer system.

In the past, less than 50 retention tank discharges per year have been required.

During 1970, the North Campus water released into the sanitary sewer system averaged 946,000 gallons per day. This provides a daily dilution factor of 315 for a 3,000 gallon waste tank, which assures that there will be no significant exposure to the public from radioactive waste discharged to the sanitary sewer system.

3.7 Limitations of Experiments Applicability:

These limits established the administrative constraints for the lowest functional capability or performance level for equipment associated with and operational characteristics of experiments conducted in the Ford Nuclear Reactor. These 9

limits have been removed from the Technical Specifications.

Page O

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under 1 OCFR70 was removed.

3.8 Fission Density Limit Applicability:

The fission density limit specified the'maximum burnup allowed for a fuel element to ensure fuel failures were not experience during the operation of the reactor. This limit has been removed from the Technical, Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel. elements in. the reactor grid." and the condition allowing for the possession of r6actor fuel under IOCFR70 was removed.

4.0 SURVEILLANCE REQUIREMENTS :,,.

! 4.1 Reactivity Limits

.: 7,,,, P :

Applicability:

All surveillance requirements for reactivity limits have been removed from the Technical Specifications' Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor placefuel elerhents in the 'reactor grid." and the condition allowing for the possession of reactor fuel under IOCFR70 was removed.

4.2 Reactor Safety System Applicability:

This specification applied to the surveillance of the reactor safety system. These surveillance requirements have been removed from the Technical Specifications.

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: "Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements-in the reactor grid." and the condition allowing for the possession of reactor fuel under 1 OCFR70 was removed.

.1 0

'0,,

.1 (4ia.~e I I

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 4.3 FNR Confinement Applicability:

These surveillance requirements apply whenever the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building exceeds 1.5 x 10.2 times the quantities in 10CFR30.72, Schedule C - Quantities of Radioactive Materials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release.

Obiective:

1.

To assure that automatic protective action is initiated to limit the release of radioactive effluents from the reactor building when required.

2.

To assure that the FNR reactor building confinement integrity is maintained when required.

Specification:

1.
a.

Gamma Radiation Detector

i.

The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum shall be calibrated annually, AND ii.

The ability of the radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum to initiate the automatic protective action required by 3.3.1.a.ii shall be tested quarterly.

OR

b.

Beta Particulate Continuous Air Monitor

i.

The beta particulate continuous air monitor for the building air exhaust shall be calibrated annually, AND ii.

The ability of the beta particulate continuous air monitor for the building air exhaust to initiate the automatic protective action required by 3.3.1.b.ii shall be tested quarterly.

2.

The condition of the following gaskets shall be inspected semiannually, and the gaskets shall be replaced whenever any evidence of deterioration is found:

a.

Building ventilation system intake and exhaust dampers;

b.

Personnel access doors;

c.

Equipment access doors;

d.

Cooling tower access door.

Bases:

The gamma radiation detector which utilizes a Geiger Mueller tube to measure the radiation level in the building air exhaust plenum has been calibrated annually for most of the operating history of the FNR.

This instrument has displayed excellent reliability over many years of operation. The continuous air monitor continuously assesses its performance and actuates a trouble alarm if any parameter falls outside of normal operating characteristics or upon failure of

'Paglo1 2

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY the detectors. The manufacturer recommends that a radiological calibration of the instrument should be conducted annually. The' semiannual inspection of the gasket materials has been occurring for most of the operating history of the FNR.

These materials are not in a damaging environment and semiannual inspection' has been found Sufficient to assure that the gasket will perform their function of liniting Ieakage.throbgh these openings in the event of a release of airborne radioactivity within the reactor building.

4.4 Primary Coolant System Applicability:

This specification applies to' the makeup water added to the reactor pool while

the quantity of4water in the reactor pool is'greater than 900 gallons ObIective" Review of the makeup water needs over a period of time allows for the detection of significant pool water leaks.

Specification:

1.

IF the quantity of water'contained in the reactor pool is greater than 900 gallons, THEN the quantity of makeup water added to the reactor pool shall be reviewed quarterly.

Bases:'

A small portion of the pool structure.is in direct contact with the soil under the reactor building. Routine inspection'of the' makeup water records over a period of time provides early warning of significant pool leaks.

4.5 Radiation Monitoring APPlicability:

This specification applies to the surveillance of the monitoring equipment used to measure area gamma levels and airborne radioactivity.

Obiective:

The objective is to assure that accurate assessment of area gamma levels and airborne radioactivity is available during the conduct of licensed activities.

Specification:

1.

Air Particulate Monitors

a.

The air particulate monitors shall be calibrated semiannually.

b.

The operation o'f the air'pa'rticulate monitors'shall be checked daily when the reactor staff is present in the facility.

c.

An air particulate monitor shall be calibrated:upon replacement or following maintenance which could affect calibration.

2.

Area Radiation Monitors:

a.,

The area radiation monitors shall be calibrated serniannually.

b.

The area radiation :monitors shall be channel checked monthly.

??

t.

~~~~~~~~~~iM.,,H; 11,,. i........,::

-.:IJ~.

XmPH I e..,

I OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY

c.

An area radiation monitor shall be calibrated and a channel check shall be performed upon replacement or following maintenance which could affect the calibration.

These surveillance requirements shall be met during the conditions specified in the Limiting Condition for Operation. Surveillances do not have to be performed on inoperable equipment Bases:

The Ford Nuclear has upgraded to the Eberline AMS-4 for the air particulate monitors. The AMS-4 continuously monitors all critical operating parameters of the unit, such as air flow, detector response, etc., and generates a local alarm whenever one of the monitored parameter falls outside the operator established range. The AMS-4 has several years of demonstrated reliable performance in the power reactor community.

The surveillance intervals provided for the air particulate monitors are sufficient to ensure the operability of the air particulate monitors between surveillance intervals.

Semiannual calibration of radiation monitors, which have displayed excellent stability over many years of operation, is adequate to verify the set point unless instrument repairs have been made.

4.6 Liquid Effluents Applicability:

This specification applies to the surveillance of the monitoring equipment used to measure the activity in liquid effluents.

Obiective:

The objective is to assure that accurate assessment of liquid effluents can be made.

Specification:

1.

The monitoring equipment used to measure the radioactive concentrations in the waste retention tank contents shall be calibrated semiannually when releases are made to the sanitary sewer.

2.

The contents of each tank released shall be sampled and evaluated prior to its release.

Bases:

Experience with the counting equipment used in measuring the radioactivity in the waste retention tanks suggests that the above period is a suitable calibration frequency. Waste water is normally recycled to the reactor pool. Consequently, discharges are not normally made to the sewer and calibrations are not normally needed.

Page i4

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 4.7 Fission Density Limits Applicabilitv:

The surveillance requirement for the fission density limit has been removed from the Technical Specifications;,

Bases:

On January 29, 2004 the license for the Ford Nuclear Reactor was modified with the following condition: 'Maximum Power Level: The licensee shall not operate the reactor nor place fuel elements in the reactor grid." and the condition allowing for the possession of reactor fuel under 1 OCFR70 was removed.

5.0 DESIGN FEATURES 5.1 Site Description The Ford Nuclear Reactor (FNR) is;'located on the North Campus of the University of Michigan at Ann Arbor, Michigan. The North Campus area is under the administrative control of the Regents of the University of Michigan.

The North Campus is a tract of nearly 900 acres, about 1-1/2 miles northeast of the center of Ann Arbor. It is bounded on the north by Plymouth Road and on the south by Glazier Way. A VA hospital and some apartments are south of Glazier Way. Apartments are located north of Plymouth Road. Open land and the Arborcrest Cemetery lie to the east. To the west are University athletic fields, municipal parks and a wooded ridge. The Huron River flows through land bordering the area on the west 'and south and some marsh land lies adjacent to the river on the south.

The reactor building is located near the center of the North Campus area. No housing or buildings containing housing facilities are erected within 1500 feet of the reactor.

The University of Michigan controls all the land within 1500 feet of the reactor site, with the exception of a small portion of the highway right of way along Glazier Way on the southeast and the Arborcrest Cemetery located 800 feet to the east of the site.

The reactor site consists of all the land 500 feet to the east, 1000 feet to the west and north' and '1200 feet to the south. The boundary of this area consists of roadways around the site whose traffic flow can be controlled should such control be desirable.

The reactor restricted area consists of the reactor building and the contiguous Phoenix Memorial Laboratory (PML).

The reactor building is the operations boundary and the emergency planning zone.

5.2 Reactor Fuel ' '

The license for the Ford Nuclear Reactor does not allow for the possession of reactor fuel.

J1~. ge~_.

15

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 5.3 Reactor Building The reactor building is a windowless, four story, reinforced concrete building with 12 inch walls structurally integral with the footings and foundation mats. The building is approximately 69 feet wide x 68 feet long x 70 feet high with approximately 44 feet exposed above grade.

The building has the following general features:

1.

The reactor is housed in a closed room designed to restrict leakage.

2.

The reactor room is equipped with a ventilation system designed to exhaust air or other gases present in the building atmosphere into an exhaust stack which exhausts a minimum of 54 feet above ground level.

3.

The ventilation system provides ventilation for certain storage and experimental facilities and exhausts these a minimum of 54 feet above ground level.

4.

The openings into the reactor building are an equipment access door, three personnel doors, an equipment access hatch, air intake and exhaust ducts, room 3103 fume hood exhaust duct, beam port ventilation duct, a sealed north wall door, a door between the hot cave operating face and the beam port floor, a sealed foundation tile drain to the cold sump, and a pneumatic tube system for sample transfer between the FNR and several laboratories in the Phoenix Memorial Laboratory.

These design features apply until the quantity of radioactive materials in unsealed form, on foils or plated sources, or sealed in glass contained in the reactor building is less than 1.5 x 10-2 times the quantities in 10CFR30.72, Schedule C - Quantities of Radioactive Materials Requiring Consideration of the Need for an Emergency Plan for Responding to a Release.

5.4 Fuel Storage The license for the Ford Nuclear Reactor does not allow for the possession of reactor fuel.

Page 16

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 6.0 ADMINISTRATIVE CONTROLS 6.1 Organization

1.

The organizational structure of the University of Michigan relating to the Ford Nuclear Reactor (FNR) shall be as shown in Figure 6.1.

2.

The Nuclear Reactor Laboratory Manager shall be responsible for the safe operation of the Ford Nuclear Reactor. 'He shall be responsible for assuring that all operations are conducted in a safe manner and within the, limits prescribed by the facility license, including the technical specifications and operating procedures; During periods of his absence, his responsibilities are delegated to the Assistant Manager for Operations or to the Assistant Manager for Research Support Activities.

3.

In all matters pertaining to th6 operation of the plant and these technical specifications, the Nuclear Reactor Laboratory Manager shall report to and be directly responsible to the Director, Michigan Memorial-Phoenix

' Project.

4.

Qualifications, Nuclear Reactor Laboratory Manager and Assistant Managers:

Minimum qualifications for the Nuclear Reactor Laboratory Manager and Assistant Managers shall be bachelor's degrees and at least four years of. reactor, operating experience in increasingly responsible positions. Years spent in graduate study may be substituted for operating experience on a one for one basis up to a maximum of two years.

Within six' months 'after being assigned these positions, the Nuclear Reactor Laboratory!Manager and the Assistant Managers shall apply for NRC senior 'operator licenses if they do not already hold licenses.

5.

A health' physicist who is organizationally independent of the Ford Nuclear Reactor operations group shall be responsible for radiological safety at the facility....

6.

A licensed operator or licensed senior operator pursuant to 10CFR55 shall be present in the control room whenever the reactor is in operation as defined in these specifications. The minimum' operating crew shall be composed of two individuals, at least one of whom shall be a licensed senior reactor operator.

7.

The Nuclear Reactor Laboratory Manager, one of -the-Assistant Managers, or a licensed senior reactor operator shall be readily available on-call 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> per day, seven days per week. The identity of and method for rapidly contacting the on-call supervisor shall be known to the reactor operator or shutdown watchman on duty.

8.

Licensed operators are not required to be present in the facility when the reactor is secured.

9.

All licensed operators at the facility shall participate in an approved operator requalification program as a condition of their continued assignment to operator duties.

,.Pjag~,17

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Figure 6.1 Organization Chart for the Ford Nuclear Reactor l

Regents University of Michigan President Provost and Executive Vice Executive Vice President President for Academic Affairs and Chief Financial Officer V IcPrsdn l

I Vice President Associate Vice President L Research

[

for Business Operations Director Director Occuptiona Safety and Michigan Memorial-Phoenix Project Ocenvional Hetalt l

Safety Review l

Director Committee Radiation Safety I

Nuclear Reactor 1 Heat__Physicist Laboratory Manager-Health Physicist 145 Assistant Manager Assistant Manager Reactor Operations Research Support Activities Licensed Operators Line Function Safety and Licensing Function Page 18

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28

'Amendment XX: XX MMM YYYY 6.2 Review and Audit

1.

A Safety Review Committee (SRC) shall review reactor operations and advise the Director, Michigan Memorial-Phoenix Project, in matters relating to the health and safety of the public and the safety of facility operations.

2.

The Safety Review Committee shall have at least eight members of whom no more than the minority shall be from the line organization shown in Figure 6.1. or shall administratively report to anyone in that line organization below the Vice President for Research. The Committee shall be made up of University faculty and staff and an individual from outside the University appointed by the Vice President for Research who shall collectively -provide

-experience in reactor engineering, instrumentation and control systems, radiological safety, and mechanical and electrical systems.

3.

The Committee shall meet at least semiannually.

4.

A quorum shall consist of not less than a majority of the full committee and shall include the chairman or his designated alternate.

5.

Those changes, experiments, and tests that require specific SRC review must be approved by a majority of the full Committee Membership. Votes may be cast at SRC meetings or via individual polling of members.

6.

Minutes of each Committee meeting shall be distributed to the Director, Michigan Memorial-Phoenix Project, all Safety Review Committee members, and such others as the chairman may designate.

7.

The Safety Review Committee shall:

a.

Review and approve proposed experiments and tests utilizing the reactor facility which are significantly, different from tests and experiments previously performed at the Ford Nuclear Reactor.

In the event of a disagreement over approval of an experiment between the Committee and the Nuclear Reactor Laboratory Manager, the matter-shall be referred to the Director, Michigan Memorial-Phoenix Project for resolution.

b.

Review reportable occurrences.

c.

Review and approve proposed standard operating procedures and proposed changes to standard, operating procedures. This requirement pertains to those procedures prepared pursuant to Section 6.4 of these specifications.

d.

Review and approve proposed changes to the technical specifications and proposed amendments to the facility license and review proposed changes to the facility made pursuant to 1 OCFR50.59(c).

e.

Review the audit report provided by the consultant for reactor operations.

8.

A consultant will be retained by the University of Michigan to perform an annual audit of reactor operations and the safety of facility operations.

The consultant shall be selected by the Director, Michigan Memorial-

,Paqp

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY Phoenix Project and shall be an individual presently or recently engaged in the management of a research or test reactor of comparable power level and type. He shall provide a report on the conclusions drawn from that audit to the Director, Michigan Memorial-Phoenix Project.

The Director shall provide the members of the Safety Review Committee with copies of this report.

9.

The audit shall be conducted with the following guidelines:

a.

At least once every five years, a broad review will be made of the following areas: (1) Administration; (2) Safety Review Committee; (3) Reactor operators; (4) Procedures; (5) Surveillance; (6)

Quality Assurance Program; (7) Logs and Records; (8)

Experiments; (9) Emergency Plan; (10) Security Plan; and (11)

Health physics support.

The purposes of the review are: (1)

Evaluate the adequacy of the organization, training, plans, procedures, surveillance, and records for safe operation of the facility; (2) Verify that the requirements of Technical Specifications are being met; (3) Establish whether plans and procedures are being implemented; and (4) Determine whether responsibilities within the organization are appropriate.

b.

Routine audits will review a limited number of systems in depth each year and will include as applicable to each system: (1)

Operating procedures and records; (2) Calibration procedures and records; (3) Equipment operation, condition, and failures; (4)

Modifications; and (5) Reportable occurrences.

6.3 Action to Be Taken in the Event of a Reportable Occurrence In the event of a reportable occurrence, as defined in these technical specifications, the following action shall be taken:

1.

The Nuclear Reactor Laboratory Manager shall be notified of the occurrence.

Corrective action shall be taken to correct the abnormal conditions and to prevent its recurrence.

2.

A report of such occurrence shall be made to the Safety Review Committee; the Director, Michigan Memorial-Phoenix Project; and the Nuclear Regulatory Commission in accordance with Section 6.6.2.a. The report shall include an analysis of the causes of the occurrence, the effectiveness of corrective actions taken, and recommended measures to prevent or reduce the probability or consequences of recurrence.

6.4 Operating Procedures Written procedures, including applicable check lists, reviewed and approved by the Safety Review Committee shall be in effect and followed for the following operations:

1.

Startup, operation and shutdown of the reactor;

2.

Installation and removal of fuel elements, control rods, experiments and experimental facilities; Page 20

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY

3.

Actions to be taken to correct specific and foreseen potential malfunctions of systems or components, including responses to alarms, suspected primary coolant system leaks, and abnormal reactivity changes;

4.

"Emergency conditions involving potential or actual release of radioactivity, including provisions for evacuation, reentry, recovery, and medical support;

5.

Maintenance procedures which could have an effect on reactor safety;

6.

Periodic surveillance of reactor instrumentation and safety systems, area monitors; and continubus air monitors;

7.

Facility security plan;

8.

Radiation protection procedures.

Substantive :changes to the above 'procedures shall be made only with the aIpproval "of. 'the Safety' Review 'Comrnittee.

Temporary changes to the procedures that do not change 'their'original intent may be made with approval of the Nuclear Reactor Laboratory Manager or one of the Assistant Managers. All temporary changes to the procedures'shall be 'documented and subsequently reviewed by the Safety Review' Comrmittee.'

6.5 Operating Records

1.

The following records and logs shall be prepared and retained by the licensee for at ldastffive'years: ' '

a.

Normal facility operation and maintenance; 2.'

b.

Reportable Occurrences;

c.

Tests, checks,' and measurements documenting compliance with surveillance requirements;

d.

Records of experiments performed;

e.

Records of radioactive shipments;

f.

Operator requalification program records (the five year period will

'-commence after termination of the assignment of the operator to operative duties);*

g.' ' Facility radiation and contamination surveys.

The following records and logs shall be-prepared and retained by the licensee for the life of the facility:

a.

Gaseous and liquid waste released to the environs;

b.

Off site environmental monitoring surveys;

c.

Radiation exposures for all FNR personnel;

d.

Fuel inventories and transfers;

e.

Updated, corr6cted; arid as built facility drawings;

' f.

Minutesof Safety Re'iew Committeerneetings.

,~jPagqf2.l

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY 6.6 Reporting Requirements In addition to reports required by Title 10, Code of Federal Regulations, the following reports shall be submitted to the United States Nuclear Regulatory Commission.

1.

Annual Operating Report A written annual operating report shall be submitted by March 31 of each year to the U. S. Nuclear Regulatory Commission, Attn.: Document Control Desk, Washington, D.C. 20555 and to the Administrator, Region Ill.

The report shall include the following information for the preceding year.

a.

Operations Summary A summary of operating experience having safety significance occurring during the reporting period.

1.

Changes in facility design.

2.

Performance characteristics (e.g., equipment and fuel performance).

3.

Changes in operating procedures which relate to the safety of facility operations.

4.

Results of surveillance tests and inspections required by these technical specifications.

5.

A brief summary of those changes, tests, and experiments which required authorization from the commission pursuant to 10CFR50.59(a).

6.

Changes in the plant operating staff serving in the following positions:

a.

Nuclear Reactor Laboratory Manager;

b.

Health Physicist;

c.

Safety Review Committee members.

b.

Power Generation A monthly tabulation of the thermal output of the facility during the reporting period.

c.

Shutdowns A listing of unscheduled shutdowns which have occurred during the reporting period, tabulated according to cause, and a brief discussion of the actions taken to prevent recurrence.

d.

Maintenance A discussion of corrective maintenance, excluding preventive maintenance, performed during the reporting period on safety related systems and components.

e.

Changes, Tests, and Experiments Page 22

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY A brief description and a summary of the safety evaluation for those changes, tests, and experiments which were carried out without prior commission approval, pursuant to the requirements of 10CFR50.59(a).

f.

Radioactive Effluent Releases A statement of the quantities of radioactive effluents released from the plant.

1.

Gaseous Effluents

a.

Gross Radibactivity Releases

1.

Total gaseous radioactivity in curies.

2. ' 'Average concentration of gaseous effluents released during normal steady state operation averaged over one year.

3.:;

Maximum instantaneous concentration of noble gas radionuclides released during

.' special operations, tests, or experiments.

4.

Percent of diluted, 10CFR20, Appendix B, Table 2,

Column 1,

air effluent concentration limit.

b.

lodirie Releases (Required. if iodine-131 is identified in primary

'!coolant' samples, or if fueled experiments are conducted at the facility.)

1.

Total iodine radioactivity in curies released by isotope, based on representative isotopic

..analyses.

2.

Percent of diluted, 10CFR20, Appendix B, Table 2,

Column 1,

air effluent concentration limit.

c.

Particulate Releases 1

'Total "particulate gross beta and gamma

radioactivity -released in curies excluding background radioactivity.
2.

Gross alpha radioactivity released in curies excluding

- background radioactivity.

(Re'quired if the operational or experimental program could result in the release of alpha emitters.)

3.

Total gross radioactivity in curies of nuclides with half lives greater than eight days.

"- :4. Percent of diluted, 10CFR20, Appendix B, Table 2,

Column 1,

air effluent concentration

limit, for particulate Page,23

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY radioactivity with half lives greater than eight days.

2.

Liquid Effluents

a.

Total gross beta and gamma radioactivity released in curies excluding tritium and average concentration released to unrestricted areas or sanitary sewer averaged over period of release.

b.

The maximum concentration of beta and gamma radioactivity released to unrestricted areas.

c.

Total alpha radioactivity in curies released and average concentration released to unrestricted areas averaged over the period of release.

(Required if the operational or experimental program could result in the release of alpha emitters.)

d.

Total volume in ml of liquid waste released.

e.

Total volume in ml of water used to dilute the liquid waste during the period of release prior to release from the building to the sanitary sewer system.

f.

Total radioactivity in curies, and concentration averaged over the period of release by nuclide

released, based on representative isotopic analyses performed for any release from a waste storage tank.
9.

Percent of diluted, 10CFR20, Appendix B, Table 3, Releases to Sewers

9.

Environmental Monitoring For each medium sampled:

1.

Number of sampling locations and a description of their location relative to the reactor.

2.

Total number of samples.

3.

Number of locations at which levels are found to be significantly higher than the remaining locations.

4.

Average annual concentrations or levels of radiation for the sampling point with the highest average concentration or level and the location of that point with respect to the site.

5.

The maximum cumulative radiation dose which could have been received by an individual continuously present in an unrestricted area during reactor operation from:

a.

Direct radiation and gaseous effluent;

b.

Liquid effluent.

Page 24

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY

6.

If levels of radioactive materials in environmental media, as determined by an environmental monitoring program, indicate the likelihood of public intakes in excess of 10% of those'that could result from continuous exposure to the concentration values listed in 10CFR20, Appendix B, Table 2, Columns. 1 and 2, estimates of the likely resultant exposure to individuals and to population groups and assumptions upon which estimates are based.

7.

If significant variations of off site environmental concentrations with time are observed, correlation of these results with effluent release shall be provided.

h.

Occupational Personnel Radiation Exposure A summary of annual whole body radiation exposures greater than 500 mrem (50 mrem for persons under 18 years of age)

received during the reporting period by facility personnel including faculty, students, or experimenters.

2.

Non-Routine Reports

a.

Reportable Occurrence Reports In the event of a reportable occurrence as defined in section 1.0, notification shall be made within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> by telephone and FAX to the Reactor 'Project Manager, Headquarters, U.S. Nuclear Regulatory Commission and to the Administrator, Region Ill, followed by a 'written report within 14 days to the U. S. Nuclear Regulatory Commission, Attn:

Document Control

Desk, Washington, D.*C220555, and to the Administrator, Region Ill.

FAX notification may be sent on the next working day in the event of a reportable occurrence during a weekend or holiday period.

The written report of a reportable occurrence, and, to the extent possible, the preliminary telephone and FAX notification shall:

1.

Describe,"analyze, and evaluate safety implications;

2.

Outline the hmeasures taken to assure that the cause of the condition is determined;

3.

Indicate the corrective action including any changes made

  • to the procedures and to the quality assurance program taken to prevent repetition of the occurrence and of similar occurrences involving similar components or systems;
4.

Evaluate the safety implications of the incident in light of

-the cumtulative experience obtained from the record of previ6us failure and malfunctions of similar systems and components.

b.

Technical Specification, Safety Analysis, and System Deficiencies A -written report shall be forwarded within 30 days to the U. S.

Nuclear. Regulatory Commission, Attn: Document Control Desk, Washington D. C. 20555, and to the Administrator, Region l1l, in the event of:

  • 6

.Page.25 11

I ll.

OPERATING LICENSE AND TECHNICAL SPECIFICATIONS Ford Nuclear Reactor Docket 50-2, License R-28 Amendment XX: XX MMM YYYY

1.

Discovery of any substantial errors in the transient or accident analyses or in the methods used for such analyses, as described in the safety analysis or in the bases for the technical specifications;

2.

Discovery of any substantial variance from performance specifications contained in the technical specifications and safety analysis.

3.

Discovery of any condition involving a possible single failure which, for a system designed against assumed failures, could result in a loss of the capability of the system to perform its safety function.

Page 26