Supplement to Exemption Request from 10 CFR 50.68(b)(1)
ML052500293
Person / Time
Site: Palisades 
Issue date: 08/25/2005
From: Harden P
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RIS-05-005
Download: ML052500293 (2)


Text

'I Committed to Nu ar Palisades Nuclear Plant Operated by Nuclear Management Company, LLC August 25, 2005 10 CFR 50.12 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Palisades Nuclear Plant Docket 50-255 License No. DPR-20 Supplement To Exemption Request From 10 CFR 50.68(b)(1)

Nuclear Regulatory Commission (NRC) Regulatory Issue Summary (RIS) 2005-05, MRegulatory Issues Regarding Criticality Analyses for Spent Fuel Pools and Independent Spent Fuel Storage Installations," was issued on March 23, 2005.

Previous to RIS 2005-05, Nuclear Management Company, LLC, (NMC) believed that the criticality requirements associated with the loading of independent spent fuel storage installation casks had been satisfied. However, NMC's detailed review of RIS 2005-05, completed in May 2005, resulted in the conclusion that Palisades Nuclear Plant (PNP) cannot comply with all of the requirements of 10 CFR 50.68.

NMC performed the necessary analysis and submitted an exemption request to the NRC on June 21, 2005, for 10 CFR 50.68. During a subsequent teleconference with the NRC on June 30,. 2005, the NRC clarified that use of the license amendment process was the appropriate means to resolve the issue instead of the exemption request process. Therefore, NMC will complete supporting criticality analyses and submit a license amendment request to allow credit for burnup to meet the requirements of 10 CFR 50.68(b)(1) in July 2006 or earlier.

NMC recognizes that the license amendment process is one potential resolution strategy, as described in RIS 2005-05. However, a cask loading campaign is scheduled to begin at PNP on October 10, 2005, to re-establish full core off-load capability in the PNP spent fuel pool. To meet this goal, NMC plans to load seven Transnuclear (TN) NUHOMS-32PT cask systems (224 assemblies). NMC would incur a hardship in using the license amendment process in that there is insufficient time available to obtain the additional analyses required to submit a license amendment request before the scheduled fall 2005 cask loading campaign. Therefore, using the license amendment process would result in a delay of the scheduled cask loading campaign and a corresponding delay in re-establishing full core off-load capability.

-I Document Control Desk Page 2 To support the PNP fall 2005 cask loading schedule for seven TN NUHOMS-32PT cask systems, NMC is requesting a one-time exemption from 10 CFR 50.68(b)(1). This exemption would expire on July 31, 2006, unless a license amendment request is submitted to allow credit for burnup to meet the requirements of 10 CFR 50.68(b)(1).

Alternatively, the exemption would expire upon subsequent approval of a submitted license amendment request.

The reason for extending the exemption request's duration beyond the completion of the fall 2005 cask loading campaign is to afford the ability for unloading a previously loaded cask. Although there are no current plans for unloading a previously loaded cask, the exemption would be required if, for unforeseen reasons, fuel needed to be removed from a cask. This is consistent with the certificate of compliance requirement for the establishment of operating procedures for cask unloading.

Summary of Commitments This letter contains one new commitment and no revisions to existing commitments.

1. NMC will complete supporting criticality analyses and submit a license amendment request to allow credit for burnup to meet the requirements of 10 CFR 50.68(b)(1),

in July 2006 or earlier.

I declare under penalty of perjury that the foregoing is true and correct. Executed on August 25 2005.

Paul A. Harden Site Vice President, Palisades Nuclear Plant Nuclear Management Company, LLC CC Administrator, Region Ill, USNRC Project Manager, Palisades, USNRC Resident Inspector, Palisades, USNRC