ML052290252
| ML052290252 | |
| Person / Time | |
|---|---|
| Site: | Perry (NPF-058) |
| Issue date: | 08/16/2005 |
| From: | NRC/NRR/DLPM |
| To: | |
| Macon W, NRR/DLPM,415-3965 | |
| Shared Package | |
| ML051960119 | List: |
| References | |
| TAC MC6179 | |
| Download: ML052290252 (2) | |
Text
Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.
5.6.1 Occupational Radiation Exposure Report Deleted 5.6.2 Annual Radiological Environmental Operating Report The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous year shall be submitted by May 1 of each year.
The report shall include summaries, interpretations, and analyses of trends of the results of the Radiological Environmental Monitoring Program for the reporting period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual (ODCM), and in 10 CFR 50. Appendix I. Sections IV.B.2, IV.B.3, and IV.C.
The Annual Radiological Envirbnmental Operating Report shall include the results of.analyses of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the ODCM. as well as summarized and tabulated (continued)
PERRY - UNIT I 5.0-16 Amendment No.136
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.2 Annual Radiological Environmental Operating Report (continued) results of these analyses and measurements in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979.
In the event that some individual results are not available for inclusion with the report. the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted in a supplementary report as soon as possible.
5.6.3 Radioactive Effluent Release Report The Radioactive Effluent Release Re ort covering the operation of the unit during the previous year shall be submitted by May 1 of each year.
The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and process control program and in conformance with 10 CFR 50.36a and 10 CFR 50.
Appendix I,Section IV.B.1.
5.6.4 Monthly Operating Reports Deleted 5.6.5 Core Operating Limits Report (COLR)
- a. Core operating limits shall be established prior to each reload cycle. or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
- 3. LCD 3.2.3. Linear Heat Generation Rate (LHGR).
(continued)
PERRY - UNIT 1 5.0-17 Amendment No. 136