ML052200481

From kanterella
Jump to navigation Jump to search
Environmental Non-Routine Event Report - LaSalle County Station Units 1 and 2
ML052200481
Person / Time
Site: LaSalle  
Issue date: 07/28/2005
From: Enright D
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RA05-61
Download: ML052200481 (2)


Text

ExekIn..

Exelon Generation Company. LLC www.exeloncorp.com NucleaT LaSalle County Station 2601 North 21" Road Marseilles, IL 61341-9757 RA05-61 Facility Operating License -Appendix B July 28, 2005 U. S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 LaSalle County Station, Units 1 and 2 Facility Operating.License Nos. NPF-1 1 and NPF-18 NRC Docket Nos. 50-373 and 50-374

Subject:

Environmental Non-Routine Event Report - LaSalle County Station In accordance with the 30-day notification requirements of Facility Operating Licenses NPF-1 1 and NPF-18, Appendix B, Environmental Protection Plan, Sections 4.1 and 5.4.2, LaSalle County Station is submitting this Environmental Non-Routine Event Report on a fish kill that occurred on the LaSalle Cooling Lake.

Event DescriDtion On June 28, 2005 at 1245 CST, a fish kill above normal mortality was identified on the station cooling lake. The initial estimate was reported as approximately 300 fish, mostly Striped Bass hybrids. The Illinois Department of Natural Resources (IDNR) was notified and an ENS notification was made pursuant to 10 CFR 50.72 (b)(2)(xi). The IDNR District Biologist arrived onsite and began an official fish count. The final count was 1515 dead fish, distributed amongst the various species as follows:

Species Number Species Number Striped Bass hybrids 1,439 Smallmouth Bass 36 Walleye 20 Channel Catfish 11 Blue Catfish 4

Yellow Bass 3

Sauger 2

Analysis and Evaluation During the period of June 27-28, 2005, Units 1 and 2 were operating at full power. Six circulating water pumps provided lake circulation (approximately 1.2 million gallons per minute).

Two lake makeup pumps (approximately 60,000 gallons per minute) provided makeup from the Illinois River with blowdown return to the Illinois River operating at approximately 32,500 gallons per minute.

June 27th was the fifth day in a row with air temperatures peaking above 900F. The circulating water inlet temperature peaked above 950F on the evening of June 27, reaching a maximum of 95.070F. This temperature peak was above the upper lethal temperature for most of the fish species listed above.

U.S. Nuclear Regulatory Commission July 28, 2005 Page 2 The cooling lake is classified as a treatment facility for the dissipation of waste heat per the station's NPDES Permit No. IL0048151 issued by the Illinois Environmental Protection Agency.

In accordance with the permit, no state or federal water quality standards are applicable to the lake itself. Effluent, thermal and chemical standards are applied to the lake blowdown effluents to the Illinois River. None of these standards were violated during this period.

Probable Cause of Event The apparent cause was that a combination of high air temperatures, low wind speeds, and high dew points, caused Cooling Lake temperatures to rise above 950F, which is the threshold at which species susceptible to increased temperatures begin to perish. A contributing cause was that the last two summers were relatively cool, which allowed cool water species and weaker fish to proliferate in the lake. When the thermal transient occurred, many of the cool water species and weaker fish succumbed to the heat distress.

Corrective Actions Dead fish were cleared from the public Recreation Area boat launches and Shad Net areas.

Inspections showed no dead fish were present in the Lake Screen House travelling screens.

Inspection of the blowdown canal to the Illinois River revealed no problems with dead fish or nuisance odors being discharged.

Actions to Prevent Recurrence There are no actions to prevent recurrence. These events are expected to periodically occur and are accounted for in the LaSalle Extreme Heat Implementation Plan.

Agencies Notified and Preliminary Responses The Illinois Department of Natural Resources was notified of the fish kill. Their preliminary response was to perform a fish count to determine the extent of the kill and the species affected.

If there are any questions or comments concerning this letter, please refer them to Terrence W. Simpkin, Regulatory Assurance Manager, at (815) 357-2800.

Respectfully, aniel End Plant Manager LaSalle County Station cc:

Regional Administrator - NRC Region IlIl NRC Senior Resident Inspector - LaSalle County Station