Text

- -

I :

RTS Instrumentation 3.3.1 Table 3.3.1-1 (page 6 of 6)

Reactor Trip System Instrumentation Note 2: Overpower AT The Overpower AT Function Allowable Value shall not exceed the following nominal Trip Setpoint by more than 0.037% of AT span.

AT <AO K4S 1+ r S T-K 6 IT -T j-f 2 (AI)j Where: AT is measured RCS AT,0F.

ATo is the indicated AT at RTP,OF.

S is the Laplace transform operator, sec1 .

T is the measured RCS average temperature,0 F.

T" is the nominal Tavg at RTP, < [*]OF.

K4 * [*] K5 2 [*]/OF for increasing Tavg K62 [*]/OF when T > T"

[*]/OF for decreasing Tavg [*]/OF when T < T" 3 [*] sec f2(AI) = [*]

  • These values denoted with [*] are specified in the COLR.

Cook Nuclear Plant Unit 1 3.3.1 -16 Amendment No. 287

RTS Instrumentation 3.3.1 Table 3.3.1-1 (page 6 of 6)

Reactor Trip System Instrumentation Note 2: Overpower AT The Overpower AT Function Allowable Value shall not exceed the following nominal Trip Setpoint by more than 0.038% of AT span.

AT <ATo K4 -K5 1 T3 S T-Kr[T -T']-f2(AIl)

Where: AT is measured RCS AT,0F.

ATO is the indicated AT at RTP, 0F.

S is the Laplace transform operator, sec1 .

T is the measured RCS average temperature,0 F.

T" is the nominal Tavg at RTP, s [*]'F.

K4 s [*] K5 - [*]/OF for increasing Tavg K6 2 [*]/OF when T > T"

[*]/OF for decreasing Tav. [*]/OF when T s T" T3¶ ]sec f2(AI) = [*]

  • These values denoted with [*] are specified in the COLR.