ML052130043
| ML052130043 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 07/19/2005 |
| From: | Gangluff R South Texas |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NOC-AE-05001911, STI 31905006 | |
| Download: ML052130043 (154) | |
Text
Nuclear Operating Company Sout rwas Pro*d Ekct Gcnm-amngsthi on 5
P ar 28d9 gWo.
7xh as 7m7483 July 19, 2005 NOC-AE-05001911 STI: 31905006 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 South Texas Project Units 1 and 2 Docket Nos. STN 50-498 and STN 50-499 TPDES Permit Renewal Application 01908 Please find attached a copy of the Renewal Application for the South Texas Project TPDES Permit No. 01908.
Appendix B of the South Texas Project Operating License requires the NRC be provided a copy of the application for renewal of the TPDES Permit at the same time the application is submitted to the permitting agency. Due to misinterpretation of Appendix B, this requirement was not fulfilled in a timely manner and is being tracked in the Corrective Action Program. The requirement to submit the wastewater discharge permit application is being evaluated for deletion from Appendix B.
There are no commitments in this letter.
If you should have any questions on this matter, please contact S. L. Dannhardt at (361) 972-8328 or myself at (361) 972-7879.
R. A. Gangluff/
Manager, Chemistry MKK
Attachment:
TPDES Permit Renewal Application for TPDES Permit No. 01908 Cal
NOC-AE-05001911 Page 2 cc:
(paper copy)
(electronic copy)
Bruce S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Richard A. Ratliff Bureau of Radiation Control Texas Department of State Health Services 1100 West 49th Street Austin, TX 78756-3189 Jeffrey Cruz U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN1 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP David H. Jaffe U. S. Nuclear Regulatory Commission Jack A. Fusco Michael A. Reed Texas Genco, LP C. Kirksey City of Austin Jon C. Wood Cox Smith Matthews J. J. Nesrsta R. K. Temple E. Alarcon City Public Service Above copies distributed without attachment.
SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION TPDES PERM IT RENEWAL APPLICATION TPIDES PERMIT NO. 01908 MAY, 2004
I 6
l w
A Nuclear Operating Company South T=s ProIed Ekdnc GcneiatfS Station PO. Boa 282 Wadswvrth, Tcxas 77483 Certified Mail May 26, 2004 NOC-TX-0401 0127 PFN: W02 STI No. 31751533 Water Quality Applications Team (MC 161)
Texas Commission on Environmental Quality 12100 Park 35 Circle Austin, Texas 78753 Re: TPDES Permit Renewal Application South Texas Project Electric Generating Station TPDES Permit No. 01908
Dear Sir/Madam:
STP Nuclear Operating Company (STPNOC) submits the enclosed TPDES permit renewal application (one original and three copies) for the South Texas Project Electric Generating Station (STPEGS). STPNOC is the authorized agent for the owners of the facility. The Texas Commission on Environmental Quality (TCEQ) transferred the permit to the STPNOC on September 18, 2003. Attached is the order transferring the permit to the STPNOC and a copy of the check for the permit renewal fee that has been sent to the Revenues Section of the TCEQ.
Although the STPEGS is a major power generating facility, it is not subject to the recently promulgated CWA §316(b) regulations. The facility employs recycle cooling water technology rather than the once through cooling systems affected by the Phase II regulations.
If you have any questions regarding this letter, or the enclosed application or attachments, please contact Doug Welch at (713) 945-7892 or by e-mail at dbwelchgtxgenco.com.
Sincerely, R. A. Gangl Manager, Chemistry RAG/sid Enclosures/Attachment
TEXAS COMMISSION ON ENVIRONMENTAL QUALITY TRANSFER OF TEXAS COMMISSION ON ENVIRONMENTAL QUALITY PERMIT NO. 01908 EPA I.D. No. TX0064947 FROM Reliant Energy, Incorporated, City of San Antonio, Central Power and Light Company, and City of Austin TO STP Nuclear Operating Company Ownership of the facilities covered by the above-referenced permit issued November 2, 2000, has changed.
That part of the signature page pertaining to the name and mailing address of the permit holder is hereby changed so that the same shall hereinafter be and read as follows:
"STP Nuclear Operating Company P.O. Box 289 Wadsworth, Texas 77483-0289" The transferee is financially responsible for the proper maintenance and operation of the facility so as to comply with the terms and conditions of the permit. The failure to operate the facility in accordance with the terms and conditions of the permit may be good cause for revocation of the permit.
This transfer is in accordance with 30 Texas Administrative Code Section 305.64.
This order is part of the permit and should be attached there to.
Issued Date: September 18, 2003.
For The Commission
TEXAS NATURAL RESOURCE CONSERVATION COMMISSION DISCHARGE MONITORING REPORT (DMR)
ADDRESS AND SIGNATORY AUTHORITY UPDATE FORM EPA ID NUMBER: TX nAh'Qa7 TPDES PERMIT NUMBER (if applicable):
n1 sea PERMITTEEAND/ORFACILITYNAME:
South Texas Project Flectric Generating Station DMR MAILING ADDRESS:
(If different from your primary mailing address stated on the permit)
P.
- 0. Box 289 (Street Address)
Wadsworth, Texas 77483 (City, State and Zip Code)
Note: If your primary mailing address has changed, please submit the revised address in writing to the Water Qu:ality Applications Team (MC 161). Please call (512) 239-5160 to request the form for this purpose.
INDIVIDUAL(S) AUTHORIZED TO SIGN DISCHARGE MONITORING REPORTS (DMRs):
(Other than Principal Executive Officer)
E. D. Halpin (Name)
R. A. Gangluff (Name)
Plant Manager (Title)
Chemistry Manager (Title)
PERSON TO CONTACT BY PHONE:
S
- l. Tfz Dnnh R rd t (Name) 361-972-8328 (Phone Number)
/Environmental Supervisor (Title)
PRINTED NAME OF PRINCIPAL EXECUTIVE OFFICER:
G. L. Parkey TITLE:
Vice President, Generation SIGNATURE:
h,4 4.A PHONE NO.:
DATE:
C 12 -r L-,
i t
361-972-7800 PLEASE RETURN COMPLETED FORMS TO:
TNRCC / WQCM Team (MC 224)
Enforcement Division Attn: Rosie Garza P.O. Box 13087 Austin, Texas 78711-3087 FOR QUESTIONS OR ASSISTANCE, PLEASE CALL THE COMPLIANCE MONITORING COORDINATOR ASSIGNED TO YOUR FACILITY.
(Rev. I ltO7,01)
TexasGenco Texas Genco P.O. Box 2846 Houston, TX 77252-2846 OVEItGIIi MAIL Ce 0T l re l*
May 21, 2004 Revenues Section (MC214)
Texas Commission on Environmental Quality P.O. Box 13088 Austin, TX 78711-3088 Re:
TPDES Permit Renewal Fee - Major Facility South Texas Project Electric Generating Station TPDES Permit No. 01908
Dear Sir/Madam:
On behalf of South Texas Project Nuclear Operating Company, Texas Genco submits the enclosed check in the amount of $2015.00, which is payment of the industrial Wastewater Application Fee applicable to a major facility subject to categorical standards promulgated by the EPA. This fee is for the South Texas Project Electric Generating Station (TPDES Permit No.
01908).
If you have any questions regarding this letter, please contact Doug Welch at (713) 945-7892.
Sincerely, Ted W. Long Supervising Engineer Texas Genco, LP Enclosure DBW/J:AEN'AWWPEKMI1TSTMTPDES 200'STP Fee Lktr doc Texas Genco, a subsidiary of CenterPoint Energy. Inc. is not the same company as CenterPoint Energy Houston, and you do not have to buy Texas P_,__J-__
S MPF-M.
vS.1-11ll am Vendor Number: 0000125347 RELIANT ENERGY WHOLESALE SERVICE COMPANY HOUSTON, TEXAS Mtl 16 433 Date:
04/07/2004 PAY Two thousandfifteen and O/10Dollars TO THE ORDER OF TEXAS COMMISSION ON EVIRONMENTAL QUALITY Box 13088 AUSTIN TX 78711 MELLON BANK WNA PITTSBURGH, PA. 15262 Sec1iTY FEATURES "CLNCWDE DETAIL ON BACK Check Number: 1005895
^'**SZs015.00 IZD SIGATURE VOID WITHOUT SIGNATURf VOID AFTER NINETY DAYS.
figS S
U 5
U 5lI
- w LIN10 S M' Sii'
':0 1.3 30 L, O0 L I. O L 2 '
1 191,10 S k 2111
TEXAS NATURAL RESOURCE CONSERVATION COMMISSION INDUSTRIAL WASTEWATER PERMIT APPLICATION SUBMISSION CHECKLIST - SUBMIT THIS WITH THE APPLICATION DO NOT SUBMIT THE INSTRUCTIONS WITH THE APPLICATION INDICATE IF THE FOLLOWING ARE INCLUDED IN THE APPLICATION.
WORKSHEET Y
N WORKSHEET Y
N ADMINISTRATIVE REPORT 1.0 WORKSHEET 6.0
=
1 ADMINISTRATIVE REPORT 1.1 WORKSHEET 7.0 SPIF WORKSHEET 9.0
/
TECHNICAL REPORT 1.0 USGS MAP WORKSHEET 1.0 1
AFFECTED LANDOWNER MAP I
WORKSHEET 2.0 F
FLOW DIAGRAM WORKSHEET 3.0 SITE DRAWING
/
WORKSHEET 4.0 ORIGINAL PHOTOGRAPHS I
WORKSHEET 4.1 1
SOLIDS MANAGEMENT PLAN WORKSHEET 5.0 WATER BALANCE It' Please indicate by a check mark the amount submitted for the application fee:
Major Minor EPA Classification New Amend.
Renewal AmendJMod.
Minor facility not subject to categorical standards promulgated by the EPA (40 CFR
$350
$350
$315
$150 Part 400-471)
Minor facility subject to categorical standards promulgated by the EPA (40 CFR
$1,250
$1,250
_$1,215
$150 Part 400-471)
Major faciliN/A
$2,050
$2,015
$450
A COPY OF THE CHIECK MUST BE SUBMITTED AS PART OF THE APPLICATION For Commission Use Only:
Segment Number County Expiration Date Region Proposed/Current Permit Number Page 1
ADMINISTRATIVE REPORT 1.0 - INDUSTRIAL THE FOLLOWING IS REOUIRED FOR ALL APPLICATIONS. RENEWAL NEW AND AMENDMENT.
The Instructions MUST BE FOLLOWED while completing the application. Failure to do so will result In significant delays in the processing of the application.
Type of application: (check all that apply)
New TPDES New TLAP Major amendment to existing pennit Minor modification to permit I
Renewal of existing permit Minor amendment to permit Storm water only discharges If applying for an amendment/modification to a permit, briefly describe the reason for the proposed amendment.
- 1.
APPLICANT INFORMATION (Instructions, Page 13)
- a. Facility owner* STP Nuclear Operating Company Charter Number (issued by the Texas Secretary of State): 1459553-01 Mailing address for use on the permit and permit correspondence:
Street No.
Street name:
Street type P.O. Box 289 City: Wadsworth State: TX Zip code: 77483 Telephone number: (361)972-7879 Tax Identification Number issued by the State Comptroller. 1-760517597-9 Charter Number (issued by the Texas Secretary of State): 1459553401
- Owner of the acility must apply fr the pemit Check one:
The TNRCC has issued this Customer Reference Number to the owner. CN: 601658669 The owner has not yet received a Customer Reference Number. A completed Core Data Form (TNRCC-10400) listing the owner as a customer and this facility as the regulated entity is attached to this application.
- b. Co-Permittee information (complete only if the operator must be a co-permittee)
Facility operator. nla Mailing address for use on the permit and permit correspondence:
Street No.
Street name:
Street type P.O. Box City:
State:
Zip code:_
Telephone number-Date of Birth:
Tax Identification Number issued by the State Comptroller:
Charter Number (issued by the Texas Secretary of State):
Check one:
The TNRCC has issued this Customer Reference Number to the co-pernittee. CN_
-The co-pennittee has not yet received a Customer Reference Number. A completed Core Data Form (TNRCC-10400) listing the co-permittee as a customer and this facility as the regulated entity is attached to this application.
Industrial Administrative Report, TNRCC410411 (Revised 3102)
Page 2
Provide a brief description as to the need for a co-permittee.
nla
- c. Individual information (complete only if the facility owner or co-permittee is an individual)
Name: ln/a Check one: _
Male _
Female State Identification Number:
Date of Birth:
Assumed business or professional name:
Home address:
Street No.
Street name:
Street type P.O. Box City:
State:
Zip code:
Telephone number:
Business name:
Check one:
The TNRCC has issued this Customer Reference Number to this person. CN:
This person has not yet received a Customer Reference Number. A completed Core Data Form (TNRCC-10400) listing this person as a customer and this facility as the regulated entity is attached to this application.
- 2.
CONTACT INFORMATION (Instructions, Pages 14)
Name: Doug Welch Company: Texas Genco, LP Telephone number 713-945-7892 Fax number 713-945-069 E-Mail: dbwelch@txgenco.com Street No. 12301 Street name: Kurland Street type: Dr.
P.O. Box City: Houston State: TX Zip code 77034 Check one or more:
V Administrative contact
/
Technical contact Name: Ted Long Company: Texas Genco, LP Telephone number. 713-945-7178 Fax number: 713-945-8069 E-Mail: tlong~txgenco.com Street No. 12301 Street name: Kurland Street type: Dr.
P.O. Box City: Houston State: TX Zip code: 77034 Check one or more:
/
Administrative contact
/
Technical contact
- 3.
NOTICE INFORMATION (Instructions, Page 14)
- a. Individual publishing the notices Name: Doug Welch Telephone number: 713-945-7892 Company: Texas Genco, LP Fax number: 713-945-8069 Street No. 12301 Street name: Kurland Street type:_Dr.
P.O. Box City: Houston State: TX Zip code: 77034 Industrial Administrative Report, TNRCC-40411 (Revised 3102)
Page 3
- b. Method of receiving Notice of Receipt and Intent to Obtain a Water Quality Permit Package and Instructions (Check one)
E-mail: E-mail address: dbwelch@txgenco.com Fax: Fax number Overnight/Priority mail: (self addressed, prepaid envelope required)
Regular Mail: Street No.
Street name:
Street type:
P.O. Box City:
State:__
_Zip:
- c. Contact in the notice Name: Doug Welch Telephone number 713-945-7892 Company: Texas Genco, LP Fax number_
Street No. 12301 Street name: Kurland Street type: Dr.
P.O. Box City: Houston State: TX Zip code: 77034
- d. Public place information Location of public building:
Public building name: Bay City Public Library - & - Matagorda Branch Library (two locations)
Name:
Telephone number 979.245-6931 1979-863-7925 Street No. _ 1001 800 Street name: 7th Street I Fisher Street Street type:____
City. Bay City I Matagorda County: Matagorda State: TX Zip code: 77414 / 77457
- 4.
FACILITY INFORMATION (Instructions, Pages 14-15) a State/TPDES Permit No. 01908 Expiration date: Dec. 1, 2004 NPDES Permit No. nla Expiration date: nla Check one:
/
The TNRCC has issued this Regulated Entity Reference Number for this facility. RN: 102395654 No RegulatoryEntityReference Numberhas been received for this facility. One or more completed Core Data Forms (TNRCC-10400) listing this facility as the regulated entity is attached to this application.
- b. Plant Name: South Texas Project Electric Generating Station County in which the facility is located: Matagorda County in which the outfall is located: Matagorda
- c. Owner of the facility: STP Nuclear Operating Company
- d. Owner of land where the facility is/will be: STP Nuclear Operating Company Iftiot the.me as the facility owner, there must be a beg tem lease agreement in effect for at least six veas. in some cases. a lease may not suffice - we instructions Street No.
Street name:
Street type:_
City:
State:
Zip code:
Industrial Administrative Report, TNRCC410411 (Revised 3102)
Page 4
- e. Ownership of effluent disposal site: nIa If Dot die sum as the f&ility owner, thee must be a kng tam lease agreemnt in effect for at kat six years Street No.
Street name:
City:
State: _____Zip code:_
Q+tt
+-.
ha..
L em-..
- f. Owner of sewage sludge disposal site: nla only iequired ifauthorizatio is being btought is the permit for sludge dispoa an property owned/coatrolled by the applicant Street No.
Street name: __
Street I City State: ____ Zip code:
- 5.
LOCATION INFORMATION (Instructions, Pages 16-17)
- a. Is the location of the facility used in the existing permit correct: __
Yes No If no, or a new permit application, please give an accurate description:
tvDe:
l r,-
n/a
- b. Is the point of discharge and discharge route in the existing permit correct:
/_Yes No If no, or a new or amendment permit application, please give an accurate description:
ril/a c.a If a TLAP, is the location of the effluent disposal in the existing permit accurate:
Yes No If no, or a new or amendment permit application, please give an accurate description:
nla Is I
- d. If a TLAP, provide the flow of effluent from the treatment facility to the effluent disposal site.
nia I
- e. For TLAP applications, please identify the nearest watercourse to the disposal site to which rainfall runoff might flow if not contained: nla Industrial Administrative Report, TNRCC-10411 (Revised 3102)
Page 5
- f. Is the location of the sewage sludge disposal site in the existing permit accurate: __
Yes If no, or a new permit application, please give an accurate description:
No N/A nla
- g. Provide a USGS Map with all required information. Indicate by a check mark that the information is provided.
V Applicant's property boundary i/
Treatment plant boundaries Point of discharge and highlighted discharge route V
Effluent disposal site boundaries I
All ponds
_ Sewage sludge disposal site V
1 mile radius and I mile downstream information
/
New and future construction See Appendix AR-5g
- h. Is the facility located in Bexar, Comal, Hays, Kinney, Medina, Travis, Uvalde, or Williamson County?
Yes i/
No If yes, additional information concerning protection of the Edwards Aquifer may be required.
- i. Identify the name and distance to the nearest city from the facility: Wadsworth, 8 Miles J. Is/will the treated wastewater discharge to a city, county, or state highway right-of-way, or a flood control district drainage ditch?
Yes
/
No If yes, indicate by a check mark if:
Authorization granted Authorization pending For new and amendment permit applications, provide copies of letters that show proof of contact and upon receipt, the approval letter.
L Is the facility located on or does the treated effluent cross Indian Land?
Yes _
No
- 6.
MISCELLANEOUS INFORMATION (Instructions, Page 17-18)
- a. Provide two names of individuals that can be contacted during the permit term.
Name: G. L. Parkey Telephone number. 361-972-7800 Company: STP Nuclear Operating Company Fax number. 361-97248577 Street No.
Street name: PO Box 289 Street City: Wadsworth State: TX Zip code: 77483 type:
Name: T. J. Jordon Telephone number: 361-972-7902 Company. STP Nuclear Operating Company Fax number: 361-972-8577 Street No.
Street name: PO Box 289 Stn City. Wadsworth State: TX Zip code: 77483
.et type:
Industrial Administrative Report, TNRCC-10411 (Revised 3102)
Page 6
- b. List each person formerly employed by the TNRCC who represented your company and was paid for service regarding the application. fla
- c. For all applications involving an average daily discharge of 5 million gallons per day or more, provide the names of all counties located within 100 statute miles downstream of the point(s) of discharge.
Matagorda
- d. Please provide the address for receiving self-reporting/DMR forms:
Company_ STP Nuclear Operating Company Chemistry Division Name:
R. A. Gangluff Street No.
Street Name:
Street Type:
P.O. BOX 289 Wadsworth
_____BoxCity:_____
TX 77483
-State: ____Zip code:________
Please provide the address for receiving Annual Billing Invoices:
Company: STP Nuclear Operating Company Department:
Chemistry Division R. A. Gangluff Name:
Street No.
Street Name:
Street Tvre:
-Jr-289 P.O. Box Wadsworth City:
TX 77483 State:
Zip code:_
Industrial Administrative Report, TNRCC-10411 (Revised 3102)
Page 7
- 7.
SIGNATURE PAGE (Instructions, Page 18)
I R. A. Gangluff Manager, Chemistry Division Typed or printed name Title certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware there are significant penalties for submitting false information, including the possibility of fine and imprisonment for known violations.
Signature:
/6 Date: ___ ___ _
Subscribed and Sworn to before me by the said _
A on this 60 dayof
/Ic n A,20 o
My commission expires on the dayof
,+
L n P r
,20 O*
° s[SEAL]
Notary Public a
o^i l"Al I 9);bn County, Texas NOTE: If co-permittees are necessary, both entities must submit separate Signature Pages.
Industrial Administrative Report, TNRCC-10411 (Revised 3102)
Page 8
TNRCC USE ONLY:
Application type:
Renewal Major Amendment Minor Amendment New County:
Admin Complete Date:
Agency Receiving SPIF:
Texas Historical Commission U.S. Fish and Wildlife I---
Texas Parks and Wildlife Army Corps of Engineers 8
SUPPLEMENTAL PERMIT INFORMATION FORM (SPIF) (Instructions, Page 18)
This form applies to TPDES permit applications only. The SPIF must be completed as a separate document. The TNRCC will mail a copy of the SPIF to each agency as required by the TNRCC agreement with EPA. If any of the items are not completely addressed and/or further information is needed, you will be contacted to provide the information before the permit is issued. Each item must be completely addressed. DO NOT REFER TO A RESPONSE OF ANY ITEM IN THE PERMIT APPLICATION FORM. Each attachment must be provided with this form, separately from the administrative report of the application.
The application will not be declared administratively complete without this form being completed in its entirety including all attachments The following applies to ali applications:
- 1. Permittee: STP Nuclear Operating Company
- 2. PermitNo. 01908 (NPDES Permit No./EPA ID No.) _la
- 3. Address of the project (location description that includes street/highway, city/vicinity, county:
8 miles west of Wadsworth, TX on FM 521
- 4. Provide the name, address, telephone and fax number of an individual who can be contacted to answer specific questions about the property:
Name: Doug Welch Telephone number 713-945-7892 Company: Texas Genco, LP Fax number: 713-945-8069 Street No. 12301 Street name: Kurland Street type: Dr.
City: Houston State: TX Zip code: 77034
- 5. List the county in which the facility is located: Matagorda
- 6. If the property is publicly owned and the owner is different than the permittee/applicant, please identify the owner of the property: nla Industrial Administrative Report, TNRCC-10411 (Revised 3102)
Page 9
TNRCC USE ONLY:
Application type:
Renewal Major Amendment Minor Amendment New County,..
Admin Complete Date:
Agency Receiving SPIF:
Texas Historical Commission U.S. Fish and Wildlife Texas Parks and Wildlife Army Corps of Engineers
- 8.
SUPPLEMENTAL PERMIT INFORMATION FORM (SPIF) (Instructions, Page 18)
This form applies to TPDES permit applicatlons onll. The SPIF must be completed as a separate document. The TNRCC will mail a copy of the SPIF to each agency as required by the TNRCC agreement with EPA. If any of the items are not completely addressed and/or further information is needed, you will be contacted to provide the information before the permit is issued. Each item must be completely addressed. DO NOT REFER TO A RESPONSE OF ANY ITEM IN THE PERMiT APPLICATION FORM. Each attachment must be provided with this form, separately from the administrative report of the application. The application will not be declared administratively complete without this form being completed in its entirety including all attachments The following applies to all applications:
- 1. Permittee: STP Nuclear Operating Company
- 2. Permit No. 01908 (NPDES Permit No./EPA ID No.) _na
- 3. Address of the project (location description that includes street/highway, city/vicinity, county:
8 miles west of Wadsworth, TX on FM 521
- 4. Provide the name, address, telephone and fax number of an individual who can be contacted to answer specific questions about the property:
Name Doug Welch Telephone number 713-945-7892 Company: Texas Genco, LP Fax number 713-94548069 Street No. 12301 Street name: Kurland Street type: Dr.
City: Houston State: TX Zip code: 77034
- 5. List the county in which the facility is located: Matagorda
- 6. If the property is publicly owned and the owner is different than the permittee/applicant, please identify the own' of the property: nla Industrial Administrative Report, TNRCC.10411 (Revised 3102)
Pag
TECHNICAL REPORT 1.0 - INDUSTRIAL THE FOLLOWING IS REQUIRED FORALL APPLICATIONS, RENEWAL, NEW,ANDAMENDMENT
- 1. FACILITY/SITE INFORMATION (Instructions, page 22)
- a. Describe the type of activity and general nature of your business.
South Texas Project Electric Generating Station is a nuclear fueled, steam-electric generating facility.
Electricity is generated from steam driven turbines.
- b. SIC Code(s) 4911
- c. Describe the wastewater generating processes.
See Appendix TR-1c.
- d. Provide a list of raw materials, major intermediates, and products handled at your facility.
Raw Materials Intermediate Products Final Products Nuclear Fuel (CAS No. 7440-61-1)
Steam Electricity See Appendix TR-Sc for the following:
Nalco 9226,19-1, 9353, 7334, 1359 plus, and H-130M.
Varichem SC 2312 Sulfuric Acid (CAS 7664-93-9)
Sodium Hypochlorite (CAS 7681-52-9)
Sodium Hydroxide (CAS 1310-73-2)
Technical Report 1.0, TNRCC-10055 (Revised 12101)
Page I
- e. Indicate by a check mark that an attached facility map with the following information was provided with the application:
Production areas, maintenance areas, materials handling areas, and waste disposal areas.
I The location of each unit of the wastewater treatment plant including the location of wastewater collection sumps and impoundments.
Attachment:
TR-1e
- f.
Is this a new permit application for an existing facility?
Yes _Z -No If yes, provide background discussion below.
n/a
- g. Is the treatment facility/disposal site located above the 100-year frequency flood level?
of-Yes No List source(s) used to determine 100-year frequency flood plain-FIRM 4854890375C March 18, 1985 If no, provide the elevation of the I 00-year frequency flood plain and describe what protective measures are in use or planned to be used to prevent flooding of the treatment facility/disposal area.
n/a
- h. For new or amendment permit applications, will there be discharge of fill material into a water in the state for construction of the proposed outfall structure?
Yes No n/a If no, proceed to Item No. 2. If yes, has the applicant applied for a U.S. Corps of Engineers 404 Dredge and Fill permit?
Yes No nia If yes, provide the permit number: n/a If no, provide the approximate date you anticipate submitting your application to the Corps.
n/a Technical Report 1.0, TNRCC-10055 (Revised 12/01)
Page 2
- 2. TREATMENT SYSTEM (Instructions, page 23)
- a. List any physical, chemical, and/or biological treatment process that you use for the treatment of wastewater at your facility. Include a description of each treatment process starting with initial treatment and finishing with the discharge point.
See Appendix TR-2a.
- b.
Indicate by a check mark that an attached flow schematic with a water balance was provided with the application showing each treatment unit and all sources of wastewater flow into the treatment plant and to each outfall/point of disposal.
Attachment:
TR-2b Flaures 1 -6
- 3. IMPOUNDMENTS (Instructions, page 23)
Do you use or plan to use any wastewater lagoons, ponds, or impoundments? /
Yes
-No If yes, complete item 3(a) for existing impoundments and items 3(a)-3(f) for new or proposed impoundments.
If no, proceed to Item No. 4.
- a. Provide the following information in the table provided:
Designation: Indicate the appropriate use designation for each pond [Treatment (I), Disposal (D), Containment (C), or Evaporation (E)]
Discharge Point: If a discharge occurs from the impoundments, designate the outfall associated with the impoundment.
Liner Information: Ifthe impoundments are lined to comply with specifications outlined for 1) a compacted clay liner (C), 2) an In-situ clay liner (1), or 3) a synthetic/plastic/rubber liner (S), indicate the liner type with the appropriate letter designation (see Instructions for further detail on liner specifications). If not, provide a reference to the attachmentthat provides a description ofthe alternate liner and any additional technical information necessary for an evaluation.
Dimensions:
Provide the dimensions(s), freeboard, surface area, and storage volume capacity of the impoundments. For impoundments with irregular shapes, submit surface area (instead of length and width), the average depth, and the maximum depth below natural ground level.
Technical Report 1.0, TNRCC-10055 (Roavsed 12101)
Page 3
Impoundment Infonnation Table
-Pond#
Pond# 2nd#
d# 3 Pond# 4 Pond# 5 Designation (T)(D)(C)or(E)
T T
T TT C
Discharge Point Outfall Number 501 i 501 I 101 l001 None Liner Information Liner Type (C) (1) or (S) iNone Alt. Liner Attachment Reference n/a n/a nla nla n/a Dimensions Length (feet) t00 ft 25 ft 136 ft ft 1so ft Width (feet) 80 ft 25 ft 42 ft ft 70 ft Depth from Water Surface 17.5 ft 13.3 ft 16 ft 25 ft 4
ft Depth from Nat. Ground Level avg 0 max 0avg 0 max 0avg 0 max
_0avg Qmax svg 0 max Freeboard (feet)
) 2 ft 2
ft 22 ft 2.5 ft
- 2 ft SurfaceArea(acres) 0.18 acres 0.01 acres 0.13 acres 7.000 acres 0.24 acres Storage Capacity (gallons) 1.eo0,00 gal.
0000o gal.
jo0e0g 202.O ac4L
'iuO gal.
- Reinforced concrete
^
Soil and Concrete Pond # 6 Pond Pond# Pd_
Pond#
Designation (T)(D)(C)or(E)
C Discharge Point Outfall Number None Liner Information Z,
Liner Type (C) (I) or (S)
T I
Alt. Liner Attachment Reference 1n/a T I_
II Dimensions Length (feet) 2,000 ft ft ft ft ft Width (feet) 1,000 ft ft It ft ft DepthfromWaterSurface 8
ft ft ft ft ft Depth from Nat. Ground Level
°avg 0 max avg _max
_avg
_max
_avg
_max
_avg
_max Freeboard (feet)
- 2 ft ft Rft ft ft Surface Area (acres) 47 acres acres acres acres acres Storage Capacity (gallons) 388 ac-t gal.
gal.
gal.
gal.
Technical Report 1.0, TNRCC-10055 (Revised 12MI)
Page 4
THE FOLLOWING ITEMS ARE REQUIRED ONLY FOR NEW OR PROPOSED IMPOUNDMENTS.
- b. Indicate by a check mark if any of the following data was provided with the application:
nla (1)
Synthetic/plastic/rubber liner data (2)
In-situ clay liner data
Attachment:
nja
- c. Are there any leak detection systems or ground water monitoring wells in place or planned?
Yes No n/a If yes, indicate by a check mark that a separate attachment was provided with the leak detection system information for each pond and/or ground water monitoring well data.
Attachment:
nfa
- d. Is the bottom of the vond above the seasonal high water table in the most shallow water bearing zone?
Yes No nta If no, indicate by a check mark that additional information was provided describing the depth of the seasonal high water table in the most shallow water bearing zone in relation to the depth of the bottom of the new or proposed impoundment and how this may or may not impact groundwater.
- e. Indicate by a check mark that the following information was provided:
Wei A USGS quadrangle map or a color copy of original quality and scale which accurately locates and identifies water supply wells and/or monitor wells within 'A mile radius of the impoundments.
Copies of State Water Well Reports (driller's logs, completion data), and data on depths to ground water for water supply wells including a description of how the depths to ground water were obtained.
For TLAP permit applications:
Indicate by a check mark that the new or proposed impoundment(s) and the land application disposal area are located in the same general area and the information for this item is provided in Worksheet 3.0 (item 8).
- f.
Indicate by a check mark if any data was provided with the application pertaining to the ground water, soils, geology, etc. used to assess the potential for migration of wastes from the impoundments and/or the potential for contamination of ground water or surface water.
Wae
- 4. OUTFALL/DISPOSAL METHOD INFORMATION (Instructions, page 25)
Complete the following tables to describe the location and wastewater discharge or disposal operations for each outfall for discharge operations and for each point of disposal for TLAP operations.
For TLAP permit applications: Indicate the disposal method and each individual irrigation area (1), evaporation pond (E), or subsurface drainage system (S) by providing the appropriate letter designation for the disposal method followed by a numerical designation for each disposal area (e.g. evaporation pond, application area) in the space provided for "Outfall" designation (e.g. "El" for evaporation pond 1, "12" for irrigation area No. 2, etc.).
Technical Report 1.0, TNRCC-10055 (Revised 12101)
-Pag e 5
OUTFALL: 001 LAtitude Longitude Location Description 28 l44 1 74 96 l 00 l 04 Discharge point at Colorado River Permitted Flow (MGD)
Proposed Flow (MGD)
Dly Avg Dly Max Dly Avg Dly Max Discharge Duration 144 200 same same (hrsJday)
(days/mo.)
(mo.fycar)
Pumped /
Gravity Measurement Device Estimate Intermittent Seasonal Continuous Contributing Wastestreams:
Volume (MGD)
% of Total Flow Recirculated cooling water
- nta
- nla Previously monitored effluent from Outfalls 101, 201, 401,
- n/a
- n/a 501 and 601.
- No discharge frorn this outfall has occurred since March 4,1997 (See Appendix TR-1c)
OUTFALL: 101 LAtitude Longitude Location Description 28 47 60 96 02 87 Approximate location of point where effluent enters Permitted Flow (MGD)
Proposed Flow (MGD) main cooling reservoir.
Dly Avg Dly Max Dly Avg Dly Max Discharge Duration report sreport same ame (hrs./day)*
(days/mo.)
(mo.year)
( Pumped Gravity Measurement Device: totalizer Intermittent Seasonal Continuous Contributing Wastestreams:
Volume (MGD)
% of Total Flow Low volume wastewater
- 0280
> 9 Previously monitored effluent from Ouffall 501 no discharge no discharge Stormwater Variable I1 Variable flow from this outfall year average of daily average flow (Jan '02 - Dec '03)
Technical Report 1.0, TNRCC-10055 (Revised 12101)
Page 6
OUTFALL: 201 Latitude Longitude Location Description 28 47 60 96 02 87 Approximate location of point where effluent enters main Permitted Flow (MGD)
Proposed Flow (MGD) cooling reservoir.
Dly Avg Dly Max Dly Avg Dly Max Discharge Duration report report same same (hrsJday)
(days/mo.) *
(moJyear)
-L Pumped -
Gravity Measurement Device: Totalizer Intermittent Seasonal Continuous Contributing Wastestreams:
Volume (MGD)
% of Total Flow Low volume wastewater.
0.025"
> 95 Stormwater Variable 5
- Variable flow from this outfall
- Two year average of Daily Average flow (Jan '02 - Dec '03)
OUTFALL: 401 Lattude Longitude Location Description 28 47 60 96 03 29 Approximate location of point where effluent enters Permitted Flow (MGD)
Proposed Flw (MGD) main cooling reseroir.
Dly Avg Dly Max Dly Avg DIS Max Discharge Duration report report same same (hrsJday) 1 (days/mo.)
(mo./year)
/
Pumped
_ Gravity Measurement Device: ultrasonic
/ Intermittent _
Seasonal _
ontinuous Contributing Wastestreans:
Volume (MGD)
% of Total Flow Treated Domestic Wastewater 0.022**
> 99 Low Volume Wastewater (air conditioning condensate, Variable c I car wash water)
Stormwater Variable c I Variable flow from this outfall
- Two year average of Daily Average flow. (Jan '02-Dec '03)
Technical Report 1.0, TNRCC-10055 (Revised 12J01)
Page 7a
OUTFALL: 501 Latitude Longitude Location Description 28 47 37 9I 02 51 Approximate location of point where effluent enters Permitted Flow (MGD)
Proposed Flow (MGD)
Outfall 101 wastestream priorto neutralization basins.
Dly Avg Dly Max Dly Avg' Dly Max Discharge Duration report pot same same 0
(hrs Jday) ° (days/mo.) 0 (mo.year)
V1 Pumped Gravity Measurement Device: Estimate I Intermittent Seasonal Continuous Contributing Wastestreams:
Volume (MGD)
% of Total Flow Metal cleaning waste
'no discharge
- no discharge Outfall has not discharge since December 1992.
OUTFALL: 601 LAtitude Longitude Location Description 28 47 33 96 l 02 30 Approximate location of point where effluent enters Permitted Flow (MGD)
Proposed Flow (MGD) main cooling reservoir.
Dly Avg Dly Max Dly Avg Dly Max Discharge Duration report report same same (hrsiday)
(days/mo.)
(moJyear)
_L_ Pumped -
Gravity Measurement Device: ultrasonic I Intermittent Seasonal Continuous Contributing Wastestreams:
Volume (MGD)
% of Total Flow Treated Domestic Wastewater 0.04**
> 99 Low Volume Wastewater (HVAC cooling tower blowdown, Variable
' I air conditioning condensate)
Stormwater Variable
' I
'Variable flow from this outfall "Two year average of Daily Average flow.
Technical Report 1.0, TNRCC.10055 (Revised 12101)
Page 7b
So BLOWDOWN AND ONCE-THROUGH COOLING WATER DISCHARGES (Instructions, page 26)
- a. Does your facility use any cooling towers or boilers that discharge blowddwn or other wastestreams to the outfall(s)?
y Yes No
- b. Does your facility discharge once-through cooling water to the outfall(s)? _Yes V' No
- c. If yes to either item a or b, indicate with a check mark that the appropriate MSDS with the following information for each chemical additive was submitted with the application.
Manufacturers Product Identification Number.
Product use. (e.g., biocide, fungicide, corrosion inhibitor, etc.)
Chemical Composition including Chemical Abstracts System (CAS) number for each ingredient.
Classify product as non-persistent, persistent, or bioaccumulative.
Product or active ingredient half-life.
Frequency of product use (e.g., 2 hr/day once every two weeks).
Product toxicity data specific to fish and aquatic invertebrate organisms.
Concentration of whole product in wastestream (if above item is for whole product)
Concentration of active ingredient in wastestream (if above item is for active ingredient)
Please provide a summary of this information in addition to the submittal of the MSDS for each specific wastestream and the associated chemical additives and specify which outfalls are affected.
Attachment:
TR-5c
- d. Cooling Towers and Boilers Number of Units Daily Avg. Blowdown f
Daily Max Blowdown Cooling Towers I
cooling towers Daily Avg: 7200 gallons/day Daily Max: 17,280 gallons/day Boilers 1
boilers Daily Avg: *_
gallons/day Daily Max:
- gallons/day 4022 gal/day for approximately 5 days/year.
(See Appendix TR-1c for more detail)
- 6. STORM WATER MANAGEMENT (Instructions, page 26)
Are there any existing or proposed outfalls which discharge storm water runoff commingled with other wastestreams?.. L.Yes _
No. If yes, provide the following information. If no, proceed to Item No. 7.
- a. Provide a brief narrative description of the industrial processes and activities that occur outdoors or in some manner that may result in exposure of the materials to precipitation or runoff in areas where runoff is generated.
Some storm water drainage from production and non-production areas Is discharged through permitted outfalls. Some storm water drainage from production and non-production areas is discharged under a TPDES Storm Water General Permit. For production areas, at least the first flush of storm water runoff from SPCC sources and production equipment areas Is collected and treated by the Oily Waste Treatment Systems (Outfall 201). Oil storage procedures are detailed In the facility's Integrated Contingency Plan. Large storage tanks are located within secondary containment. Tanks of acid and caustic are located within secondary containment or curbed areas for spill control.
Outdoor storage of equipment is limited to Items that will not significantly affect storm water quality.
Potential storm water contamination sources and best management practices for storm water runoff are addressed In the facility's Industrial Storm Water Pollution Prevention Plan.
Technical Ropon 1.0, TNRCC-10055 (RevIsed 12101)
Page 8 Technical Report 1.0, TNRCC-10055 JR&vlsed 12101)
Page 8
- 7. DOMESTIC SEWAGE, SEWAGE SLUDGE, AND/OR SEPTAGE MANAGEMENT AND DISPOSAL (Instructions, page 27)
- a. Please checkthe appropriate method(s) of domestic sewage and domestic sewage sludge treatment/disposal and complete Attachment F if directed.
Domestic sewage is not generated on-site. PROCEED TO ITEM NO. &
Both domestic and industrial treatment sludge ARE commingled prior to use or disposal. PROCEED TO ITEM NO. 8 Industrial wastewater and domestic sewage are treated separately and the respective sludge IS NOT commingled prior to sludge use or disposal.
COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
If your facility is a POTW, COMPLETE WORKSHEET 5.0 OF THIS APPLICATION.
Facility is connected to a wastewater treatment plant permitted to receive domestic sewage, or the domestic sewage is transported off-site to a permitted facility for treatment and/or disposal. COMPLETE ITEM NO. 7.B.
Domestic sewage is disposed of by an on-site septic tank. COMPLETE ITEM 7.B.
Other. Please provide a detailed description below.
nla
- b. Provide the name and TNRCC, NPDES, and/or TPDES Permit No. ofthe waste disposal facility which receives the domestic sewage/septage. If hauled by motorized vehicle, provide the name and TNRCC Registration No.
of the hauler.
Plant/Hauler Name Permit/Registration No.
STP Nuclear Operating Company Beneficial Land Use Site TCEQ Permit No. 04523 Sewage sludge does not leave STP Nuclear Operating Co. property.
I_--------_-_-_
- 8. IMPROVEMENTS OR COMPLIANCE/ENFORCEMENT REQUIREMENTS (Instructions, page 27)
Is the permittee currently required to meet any implementation schedule for compliance or enforcement?
If Yes
,o No If yes, provide a brief summary of thie requirements and a status update.
nla Technical Report 1.0. TNRCC-1 0055 (RevIsed 12101)
Page 9 Technical Report 1.0, TNRCC-10055 (Revised 12M1}
Page 9
- 9. TOXICITY TESTING (Instructions, page 27)
Have any biological tests for acute or chronic toxicity been made on any of your discharges or on a receiving water in relation to your discharge within the last three (3) years?
Yes I
No See Appendix TR-1c If yes, identify the tests and describe their purposes below. Please attach a copy of all tests performed that have not been previously sent to the TNRCC and/or EPA.
nla
- 10. OFF-SITEITHIRD PARTY WASTES (Instructions, page 28)
Do you receive wastes from off-site sources for treatment in your facility, disposal on-site via land application, and/or discharge via a permitted outfall?
Yes i/
No If no, proceed to Item No. 11. If yes, proceed as directed.
- a. Indicate with a check mark that a detailed attachment with the following information was provided with the application:
Attachment:
n/a List of wastes received Identified sources of wastes received Characterization of wastes received Name and addresses of generators Volumes of each waste received Description of the relationship of waste
=
Info. on compatibility with on-site wastes source(s) with your facility's activities.
- b. Is wastewater from a TNRCC, NPDES, and/or TPDES permitted facility commingled with your wastewater afteryourfinaltreatmentandpriortodischargeviayourfinal outfall/point of disposal?_
Yes i/ No If yes, provide the name, address, and TNRCC, NPDES, and/or TPDES permit number of the contributing facility and a copy of any agreements and/or contracts relating to this activity.
- c. Is your facility a Publicly Owned Treatment Works (POTW) that accepts process wastewater from any Significant Industrial User (SIU) and has or is required to have an approved pretreatment program under the NPDES/TPDES program?
Yes
/
No If yes, complete Worksheet 6.0 of this application.
- 11. RADIOACTIVE MATERIALS (Instructions, page 28)
Are radioactive materials mined, used, stored, or processed at this facility?
/
Yes No If yes, Provide a list of the materials and the results of one analysis of your effluent in picocuries per liter (pCi/L) for all radioactive parameters which may be present.
Radioactive Materials Cone. (pCiJL)
Nuclear Fuel (CAS No. 7440-611) 11,000 pCi/L of tritium Technical Report 1.0, TNRCC-100s5 (Revised 12101)
Page IO
THE FOLLOWING ITEMS ARE ONLY REOUIRED FOR EXISTING PERMITTED FACILITIES.
- 12. MAJOR AMENDMENT REQUESTS (Instructions, page 28)
Are you requesting a major amendment of an existing permit?
Yes
/
No If yes, list each specific request and provide discussion on the scope of any requested permit changes.
n/a If necessary, provide supplemental information or additional data that will support the request.
- 13. MINOR MODIFICATION REQUESTS (Instructions, page 29)
Are you requesting any minor modifications to the permit? __Yes /
No Note: see the instructions for an exclusive list of changes considered as minor modifications.
If yes, list and discuss the requested changes.
n/a
- 14. MINOR AMENDMENT REQUESTS (Instructions, page 29)
Are you requesting any minor amendments to the permit? ___Yes
/
No If yes, list and discuss the requested changes.
n/a Technical Report 1.0, TNRCC-10055 (Revised 12101)
Page I I
WORKSHEETS TO THE INDUSTRIAL WASTEWATER PERMIT APPLICATION TECHNICAL REPORT Please review the worksheet requirements in the instructions and indicate by checking either yes or no which worksheets are required, completed, and submitted with the technical report. Worksheets that are not applicable do not need to be submitted with the technical report.
WORKSHEET COMPLETED AND SUBMITTED WITH THE TECHNICAL REPORT:
YES NO 1.0: EPA EFFLUENT CATEGORICAL GUIDELINES 2.0: POLLUTANT ANALYSES REQUIREMENTS
/
3.0: LAND DISPOSAL OF EFFLUENT 4.0: RECEIVING WATERS 4.1: STREAM PHYSICAL CHARACTERISTICS WORKSHEET 5.0: SEWAGE SLUDGE MANAGEMENT AND DISPOSAL
/
6.0: INDUSTRIAL WASTE CONTRIBUTION 7.0: STORM WATER RUNOFF 8.0: AQUACULTURE (Reserved)
N/A N/A 9.0: CLASS V INJECTION WELL
/
Technical Raport 1.0, TNRCC-10056 (Revised 12101)
-Pa-ge 12
WORKSHEET 1.0 - EPA EFFLUENT CATEGORICAL GUIDELINES REQUIRED FOR ALL APPLICATIONS FOR TPDES PERMITS FOR DISCHARGES OF WASTEWATERS SUBJECT TO EPA EFFLUENT LIMITATION GUIDELINES.
- 1.
CATEGORICAL INDUSTRIES (Instructions, page 31)
Is your facility subject to any of the 40 CFR effluent guidelines outlined in Table 1? L.
Yes No If yes, provide the appropriate information in the table below. If no, this worksheet is not required.
Industry CFR Steam Electric Power Generating 423
- 2.
PRODUCTION/PROCESS DATA (Instructions, page 32)
- a.
Production data: Provide the appropriate data for effluent guidelines with production based effluent limitations.
Subcategory Actual Quantity/Day Design Quantity/Day Units WA i
- b.
Organic Chemicals, Plastics, and Synthetic Fibers Manufacturing Data (40 CFR Part 414): Provide each appropriate subpart and the percent of total production. Also provide the appropriate data for metal bearing wastestreams as required in 40 CFR Part 414, Appendices A and B.
Subcategory
% of total Appendix A and B I
-Metal Process nla
- I I
I I
Worksheet 1.0, TNRCC410065 (Revised 12101)
Page 1-1
- c.
Refineries (40 CFR Part 419): Provide the applicable subcategory and a briefjustification for each.
- 3.
PROCESSINON-PROCESS WASTEWATER FLOWS: Provide a breakdown of process wastewater flow(s) and non-process wastewater flow(s) as directed. (Instructions, page 32)
See Appendix WS 1.0-3
- 4.
NEW SOURCE DETERMINATION: Provide a list of wastewater generating processes subject to effluent guidelines and the appropriate information. (Instructions, page 32)
Process EPA Guideline Date Process/Construction Commenced Part Subpart Metal Cleaning Waste Treatment 423 13 e 0812411988 Low Volume Waste Sources 423 15 c 08124/1988 Woksee
.0 TN C.105 Reie 111)P g 1-Workshest 1.0, TNRCC-10055 (Revised 12101)
Page 1-2
WORKSHEET 2.0 - POLLUTANT ANALYSES REQUIREMENTS REQUIRED FOR APPLICATIONS SUBMITTED FOR A TPDES PERMIT. NOT REQUIRED FOR APPLICATIONS FOR A PERMIT TO DISPOSE OF ALL WASTEWATER BY LAND DISPOSAL OR FOR DISCHARGES SOLELY OF STORM WATER RUNOFF. (General Requirements: Instructions, Page 33) cc No Data - See Appendix TR-1c) >>
- 1.
TABLE 1:
Complete table required for all external outfalls. (Instructions, Page 34) l.fuait w-
- nn1 Irn,.n vC#1.wn l
- n.
e,*ot irnn fl~+.n
~"V Pollutants Samp. 1 Samp. 2 Samp. 3 Samp. 4 Averamge BOD (5-day)
CBOD (5-day)
Chemical Oxvyen Demand Total Oreanic Carbon A ni,',¶In; tiu.vt.r.pn A^.
V§ Dst Tntit V.VcrndAAd RoidAc
.1.
- 4.
4.-.4 4
Nitrate Nitrogen 4
- 4.
- 4.
4 T-tlm r-.1 Ntr_-
- 4' 4,
IUf I
I
- 4.
4.I.4 Tat+.l hn-c 3 V03 I UwavOlwJ I
I I
I I
Oil anti Grease I
I.
4 Total gRemidgg rdhinrinoe Total Dissolved Solidslid Sulfate Chloride Fluoride Fecal Coliform Temperature( 0F)
H4 (StandiardA I Inits min/n/rmna r
a-v..
- -La
_m ncentt MAl, (ugaL Total Aluminum 30 Total Antimony 30 Total Arsenic 10 Total Barium 10 Total Beryllium 5
Total Cadmium I
Total Chromium 10 Trivalent Chromium N/A Hexavalent Chromium
__=__Ijn Total Coooer I n Cyanide 20 Total Lead 5
Total Mercury 0.2 Total Nickel 10 Total Selenium 10 Total Silver 2.0 Total Thallium 10 Total 7inc S5 Workshtet 20, TNRCC-10055 (Revised 12101)
Page 2-1
- 2.
TABLE 2:
Complete table required for all external outfalls which discharge process wastewater. Partial table required for all external outfalls with nonprocess wastewater discharges. Storm water NOT REQUIRED runoffdischarges commingled with other wastestreams shall complete the table as instructed (Instructions, Page 34).
Ouffall No.:
_ Effluent Concentration (ua/1) (* 1 )
- --e Pollutants SamP. 1 Samp.2 l Samp. 3 Samp.4 Averaze MAL (g/L Benzene
______10 Benzidine so Benzo(a)anthracene I10 Benzo(a)vvrene 10 Carbon Tetrachloride I10 Chlorobenzene I10 Chloroformn I 0 1 Chrvsene I10 Cresols
(*2)
Dibrorochloromethane 10 I 2-Dibromoethane 2
1.4-Dichlorobenzene 1 0 I.2-Dichloroethane I10 I.l-Dichloroethvlene X
<10 Fluoride 500 Hexachlorobenzene I n Hexachlorobutadiene I10 Hexachloroethane 20 Methvl Ethyl Ketone 50 Nitrobenzene 1 n n-Nitrosodiethvlamine 20 n-Nitroso-di-n-Butvlamine 20 PCB's. Total (3)
I Pentachlorobenzene 20 PentachloroDhenol 50 Phenanthrene Pvridine 20 1.2,4.5-Tetrachlorobenzene 20 Tetrachloroethvlene 10 Trichloroethylene 10 1,. I -Trichloroethane 10 2,4,5-Trichlorophenol
____50 TTHM (Total Trihalomethanes) 10 Vinyl Chloride 10
(*1)
Indicate units if different from Itg/l.
1
(*2)
MAL's for Cresols: p-Chloro-m-Cresol 10 gg/l; 4,6-Dinitro-o-Cresol 50 pgfl; p-Cresol 10 jtg/l
(*3)
Total of PCB-1242, PCB-1254, PCB-122 1, PCB-1232, PCB-1248, PCB-1260, PCB-10 1 6.
Worksheet 2.0, TNRCC-10055 (Revised 12101)
Page 2-2
- 3.
TABLE 3:
Partial table (only those pollutants which are required by the conditions specified) required for each external outfall. Not required for internal outfalls. (Instructions, Page 34)
- a.
TRIBUTYLTIN:
Is your facility or will your proposed facility be an industrial/commercial facilities which directly disposes of wastewater from the types of operations listed below or a domestic facilities which receive wastewater from the types of industrial/commercial operations listed below?
Yes _
No If yes, indicate with a check mark all of the following criteria which apply and provide the appropriate testing results in the table below.
n~a Manufacturers and formulators of tributyltin or related compounds.
Painting of ships, boats and marine structures.
Ship and boat building and repairing.
Ship and boat cleaning, salvage, wrecking and scaling.
Operation and maintenance of marine cargo handling facilities and marinas Facilities engaged in wood preserving Any other industriallcommercial facility for which tributyltin is known to be present, or for which there is any reason to believe that tributyltin may be present in the effluent.
- b.
ENTEROCOCCI Does your facility or will your proposed facility discharge directly into saltwater receiving waters?
Yes
_No If yes, provide the appropriate testing results in the table below.
TABLE 3 Outfall No.: 001 OC EfG fluent Concentrat on (ue____ll_
Pollutants Samp. 1 Samp. 2 Samp. 3 Samn. 4 Average MAL (unil)
Tributyltin 0.010 Enterococci See Appendix TR-1 c N/A Worksheet 2.0, TNRCC-10055 (Revised 12101)
Page 2-3
- 4.
TABLE 4:
Complete table required for all external outfalls which discharge process wastewater and other wastewaters, which may contain pesticides or herbicides, from a facility which manufactures or formulates pesticides or herbicides. Not required for internal outfalls.
(Instructions, Page 35)
Does your facility manufacture or formulate pesticides or herbicides? _Y es No If yes, provide the appropriate testing results.
NOT REQUIRED TABLE 4 Outfall No.:
[
M
]EfMuent Concentration (ua/l) (* 1)
MAL Pollutants Samp. I Samp. 2 Samp. 3 Samp. 4 Av Wgh)
Beta-hexachlorocyclohexane 0.05 Carbaryl 5
Chlordane 0.15 Chlorpyrifos 0.05 2.4-D 10 Danitol 4,4'-DDD 0.1 4,4'-DDE 0.1 4,4'-DDT 0.1 Demeton 0.2 Diazinon 0.5 Dicofol 20 Dieldrin 0.1 Diuron Endosulfan I (alpha) 0.1 Endosulfan 11 (beta)
_0.1 Endosulfan Sulfate 0.1 Endrin 0.1 Gamma - Hexachlorocyclohexane (Lindane) 0.05 Guthion 0.10 Heptachlor 0.05 Heptachlor Epoxide 1.0 Hexachlorophene 10 Malathion 0.10 Methoxychlor 2.0 Mirex 0.2 Parathion 0.1 Toxaphene 5
2A.5-TP (Silvex) 2
- Indicate units if different from mgQL.
Workshet 2L0, TNRCC-1 0055 (Revised 12101)
Page 2-4
- 5.
TABLE 5:
Complete table required for all external outfalls. Not required for internal outfalls.
(Instructions, Page 35)
<< No Data - See Appendix TR-1c >>
TABLE S Outfall No.:
10C EG Believed Believed Effluent Concentrgtion(m/l)
____hi__
Pollutants l
_Present Absent Average Maximum No. of Samples Bromide X
s0 ColorhPCLJX X
- 0 Nitrate-Nitrite(as N)
X Sulfide(as S)
X Sulfite(as SOJ)_
X Surfactants X
Total Antimony X
Total Bervilium X
Total Boron X
0 Total Cobalt X
Total Iron X
- 0 Total Magnesium X
- 0 Total Molybdenum enX u
Total Manganese X
- 0 Total Thallium X
Total Tin X
Total Titanium X
- Constituent previous identified through sampling.
Worksheht 2.0, TNRCC-10055 (Revised 121011 Page 2-5
- 6.
TABLE 6: Indicate with a check mark any of the industrial categories applicable to your facility. If testing is required, indicate with a check mark in the box provided that the testing results for the appropriate parameters in Table B-7 are provided with the application. (Instructions, Page 35)
N/A GC/MS Testing Required Adhesives and Sealants Aluminum Forming Auto and Other Laundries Battery Manufacturing Coal Mining Coil Coating Copper Forming Electric and Electronic Components Electroplating Explosives Manufacturing Foundries Gum and Wood Chemicals
..ubparts A,B,C,E Subparts DF Inorganic Chemicals Iron and Steel Manufacturing Leather Tanning/Finishing Mechanical Products Manufacturing Nonferrous Metals Mfg.
Ore Mining(Subpart B)
Organic Chemicals, Plastics, and Synthetic Fibers Paint and Ink Formulation Pesticides Petroleum Refining Pharmaceutical Preparations Photographic Equipment and Supplies Plastic and Synthetic Materials Manufacturing Plastic Processing Porcelain Enameling Printing and Publishing Pulp and Paperboard Mills Subparts A Subprts BC,DR Subparts FGH,I,KL,MN,O,P Subparts E,Q,ST Subparts J,U
____Rubber Processing Soap and Detergent Manufacturing
_Steam Electric Power Plants See Appendix TR-lc
_Textile Mills (Not Subpart C)
Timber Products Processing Volatile Yesl Yes[:
YesmE YesE No YesE]
YesEl YesEl Yes[--
No D Yes El Yes[-L YesEl YesFl Yes El Yes LI Yes[:l Yes[E No Yes El YesE YesFl Yes El Yes[El Yesl Yes El Yes El No YesE]
Acid Yes El Yes El Yes E No No Yesl Yes[El YesE YesEl YesE YesE Yesl Yesl Yes[El Yes[E YesE Yes El Yesl Yesml YesEl Yes El YesCl No YesEl YesEl Yes El No No YesFl Base/Neutral Yesl Yesl Yes E YesE No Yes[
YesE:l YesE Yes[El YesE YesE No YesEl Yes[El YesE]
Yes El Yes[E YesE No YesEl YesE YesE No YesE]
Yes[El YesE No No Yes E Pesticides No No Yes[:
No No No No Yes E No No No No No No No No No Yeszl No Yes[l No YesE No No No Yesl No No YesEl
- [E Yes l
- E Yesl
- El Yesl El
- El YesEl Yesl
- El
- El YesFl Yes :l
- [E Yes[l Yes[l Yes l Yes[l
- EC YesF l Yes Yes[l No Yes[l Yes l YesFl No Yes[l Yes l No No YesFl YesEl YesFl No YesFl Yes l YesMl Yesl
- Test if "believed present" Worksheet 2.0, TNRCC-10055 (Revised 12101)
P-age 2-6
- 7.
TABLE 7:
Please complete as directed and only for those parameters specified in Table 6. Required for all external outfalls which contain process wastewater. Not required for internal outfalls.
Testing may be required for types of industry not specified in Table 6 for specific parameters if believed present (Instructions, Page 36).
<c No Data - See Appendix TR-1c >>
TABLE 7 Outfall No.:
l o
c I;G Efuent Concentration (UIl)
- l}
Pollutants Average Maximum l No.ofSamples MAL(g4)
VOLATILE COMPOUNDS Acrolein SO Acrylonitrile 50 Benzene 10 Bromoform 10 Carbon Tetrachloride 10 Chlorobenzene I
10 Chlorodibromomethane 10 Chloroethane 50 2-Chloroethylvinyl Ether 10 Chloroform 10 Dichlorobromomethane 10 1,1 -Dichloroethane 10 1,2,-Dichloroethane 10 1, I-Dichloroethylene 10 1,2-Dichloropropane 10 I,3-Dichloropropylene 10 Ethylbenzene 10 Methyl Bromide 20 Methyl Chloride 50 Methylene Chloride 20 1,1,2,2-Tetrachloroethane 10 Tetrachloroethylene 50 Toluene 10 1,2-Trans-Dichloroethylene 10 1,1, I -Trichloroethane 10 1,1,2-Trichloroethane 10 Trichloroethylene 10 Vinyl Chloride
_10 Worksheet L0, TNRCC-10055 (Revised 12101)
Page 2-7
Effluent Concentration futA)
- Pollutants Averane l
Maximum N-o. of Samples MAL (ugl)
ACID COMPOUNDS 2-Chlorophenol 10 2,4-Dichlorophenol 1O 2,4-Dimethylphenol 10 4,6-Dnitro-o-Cresol 50 2,4-Dinitrophenol 50 2-Nitrophenol 20 4-Nitrophenol 50 P-Chloro-m-Cresol 10 Pentachlorophenol 50 Phenol 10 2,4,6-Trichlorophenol 10 BASEJNEUTRAL COMPOUNDS Not Required -
- _:^.._-___
Acenaphthene T
10 Acenaphthylene 10 Anthracene l 10 Benzidine
_50 Benzo(a)Anthracene 10 Benzo(a)Pyrene 10 3,4-Benzofluoranthene 10 Benzo(ghi)Perylene 20 Benzo(k)Fluoranthene 10 Bis(2-Chloroethoxy)Methane 10 Bis(2-Chlorocthyl)Ether 10 Bis(2-Chloroisopropyl)Ether 10 Bis(2-Ethylhexyl)Phthalatc 10 4-Bromophenyl Phenyl Ether 10 Chrysene 10 Dibenzo(a,h)Anthracenc 20 1,2-Dichlorobenzene 10 1,3-Dichlorobenzene 10 1,4-Dichlorobenzene 10 3,3-Dichlorobenzidine 50 Diethyl Phthalate 10 Dimethyl Phthalate 10 Di-n-Butyl Phthalate 10 2,4-Dinitrotoluene 10 Worksheat 2L0, TNRCC-1005S (Revised 12101)
Page 2-8
-__ Pd:_ EffluentConcentration(uy )*
Pollutants Not Required Average Maximum No. of Samples MAL ug/l)
BASE/NEUTRAL COMPOUNDS (cont.)
2,6-Dinitrotoluene TIT_10 Di-n-Octyl Phthalate T
_IT_10 1,2-Diphenyl Hydrazine (as Azobenzene) 20 Fluoranthene 10 Fluorene 10 Hexachlorobenzene 10 Hexachlorobutadiene 10 Hexachlorocyclopentadiene 10 Hexachloroethane 20 Indeno( 1,2,3-cd)pyrene 20 Isophorone 10 Naphthalene 10 Nitrobenzene 10 N-Nitrosodimethylamin e 50 N-Nitrosodi-n-Propylamine 20 N-Nitrosodiphenylamnine 20 Phenanthrene 10 Pyrene 10 1,2,4-Trichlorobenzene 10 PESTICIDES Not Required Aldrin T
IT 0.05 alpha-BHC T
I T 0.05 beta-BHC 0.05 gamma-BHC 0.05 delta-BHC 0.05 Chlordane 0.15 4,4,-DDT 0.1 4,4,-DDE 0.1 4,4,-DDE 0.1 Dieldrin 0.1 alpha-Endosulfan 0.1 beta-Endosulfan 0.1 Endosulfan Sulfate 0.1 Endrin 0.1 Endrin Aldehyde 0.1 Heptachlor 0.05 Worksheot 2.0, TNRCC-10055 (Revised 12101)
Page 2-9
-__________X_-____________.____
_dm-_;_
E ffluent Concentration (u) -
1 Pollutants Not Required Average Maximum No. of Samples MAL (pg/l)
PESTICIDES (cont.)
-__C____._..:
PCB-1254 1.0 PCB-1221 1.0 PCB-1232 1.0 PCB-1248 1.0 PCB-1260 1.0 PCB-1016 1.0 Toxaphene 5.0 Indicate units if different from Rg/1 Worksheet 2L0, TNRCC-10055 {Revised 12I01)
Page 2-10
- 8.
TABLE 8 (DIOXINS/FURAN COMPOUNDS): Please complete as directed. Not required for internal outfalls.
(Instructions, Page 36)
- a.
Are any of the following compounds manufactured and/or used in a process at the facility?
Yes V/ No If yes, indicate with a check mark the compound(s) which apply and provide a brief description of the conditions of its/their presence at the facility.
2,4,5-trichlorophenoxy acetic acid (2,4,5-T) CAS #93-76-5 2-(2,4,5-trichlorophenoxy) propanoic acid (Silvex, 2,4,5-TP) CAS #93-72-1 2-(2,4,5-trichlorophenoxy) ethyl 2,2-dichloropropionate (Erbon) CAS #136-25-4 0,0-dirnethyl 0-(2,4,5-trichlorophenyl) phosphorothioate (Ronnel) CAS #299-84-3 2,4,5-trichlorophenol (TCP) CAS #95-95-4 Hexachlorophene (HCP) CAS #70-30-4 b
Do you know or have any reason to believe that 2,3,7,8 Tetrachlorodibenzo-P-Dioxin (TCDD) or any congeners of TCDD may be present in your effluent?
Yes
/
No If yes, provide a brief description of the conditions for its presence.
- c.
If your responded yes to either item a or b. complete Table 8 as instructed.
rla TABLE 8 Outfall DC OG Wastewater Sludge Equivalent Concentration Equivalents Concentration Equivalents Compound Factors (ppq)
(ppq)
(pPt)
(pPt)
MAL (ppq) 2,3,7,8-TCDD 1
10.0 I,2,3,7,8-PeCDD 0.5 50.0 2,3,7,8-HxCDDs 0.1 50.0 2,3,7,8-TCDF 0.1 10.0 I,2,3,7,8-PeCDF 0.05 50.0 2,3,4,7,8-PeCDF 0.5 50.0 2,3,7,8-HxCDFs 0.1 50.0 Total Worksheet2.0, TNRCC-10055 (Revised 12101)
Page 2-1 1
- 9.
TABLE 9 (HAZARDOUS SUBSTANCES): Proceed complete as directed. Not required for internal outfalls.
(Instructions, Page 37)
- a.
Are there any pollutants listed in the instructions (page 37) believed present in the discharge?
Yes V
No b
Are there pollutants listed in Item No. I.d. on Page No. 1 of this technical report which are believed present in the discharge and have not been analytically quantified elsewhere in this application?
Yes VI No If your responded yes to either item, complete Table 9 as instructed.
TABLE 9 Worksheet 2.0, TNRCC-10055 (Revised 12101)
Page 2-12
WORKSHEET 4.0 - RECEIVING WATERS THE FOLLOWING IS REQUIRED FOR ALL TPDES PERMIT APPLICATIONS
- 1.
DOMESTIC DRINKING WATER SUPPLY (Instructions, Page 46)
Is there a surface water intake for domestic drinking water supply located within 5 (five) miles downstream from the point/proposed point of discharge?
Yes V' No If yes, identify owner of the drinking water supply, the distance and direction to the intake, and locate and identify the intake on the USGS map. Indicate by a check mark that the requested information is provided:-
- 2.
DISCHARGE INTO TIDALLY INFLUENCED WATERS (Instructions, Page 46)
- a. Width of the receiving water at the outfall?
300 feet
- b. Are there oyster reefs in the vicinity of the discharge?
Yes
/
No If yes, indicate approximate distance and direction from outfall(s): nla
- c. Are there any sea grasses within the vicinity of the point of discharge?
-Yes
/
No If yes, provide the distance and direction to the grasses: nla
- 3.
CLASSIFIED SEGMENT (Instructions, Page 46)
Is the discharge directly into (or within 300 feet of) a classified segment?
I Yes No If yes, stop here. It is not necessary to complete items 4 and 5 and it is not necessary to complete Worksheet 2. 1.
If no, complete items 4 and 5.
- 4.
DESCRIPTION OF IMMEDIATE RECEIVING WATERS (Instructions, Pages 46)
Name ofthe immediate receiving waters: nla
- a. Check the appropriate description of the receiving waters Open Bay Tidal Stream, Bayou, or Marsh Lake or Pond Surface area acres.
Average depth of the entire water body feet Average depth of water body within a 500-foot radius or the discharge point feet Freshwater Swamp or Marsh Other:
Man-made Channel or Ditch Stream If a man-made channel, ditch or stream was checked above, provide the following:
- b. Check one of the following that best characterizes the area upstream of the discharge. For new discharges, characterize the area downstream or discharge (check one).
Intermittent (dry for at least one week during most years)
Intermittent with Perennial Pools (enduring pools containing sufficient habitat to maintain significant aquatic life uses)
Perennial (normally flowing)
Worksheet 4.0, TNRCC-10055 {Revised 12101)
Page 4-1
Check the method used to characterize the area upstream (or downstream for new dischargers):
USGS flow
- records, personal observation, historical observation by adjacent landowner(s),
others, specify:
- c. List the name(s) of all perennial streams that join the receiving water within three miles downstream of the discharge point:
- d. Do the receiving water characteristics change within three miles downstream of the discharge? (e.g., natural or man-made dams, ponds, reservoirs, etc.)
Yes No If yes, discuss how:
n/a
- e. Provide general observations of the water body during normal dry weather conditions:
n/a Date and time of observation:
Was water body influenced by storm water runoff during observations?
Yes No
- 5.
GENERAL CHARACTERISTICS OF WATER BODY (Instructions, Page 47)
- a. Is the receiving water upstream of the discharges or proposed discharge site influenced by (check as appropriate):
oil field activities agricultural runoff upstream discharges urban runoff septic tanks others, specify below
- b. Uses of water body, observed or evidences of (check as appropriate):
livestock watering contact recreation irrigation withdrawal non contact recreation fishing navigation domestic water supply industrial water supply picnic park activities others, specify below n/a
- c. Check one of the following to best describe the aesthetics of the receiving water and the surrounding area:
Wilderness: outstanding natural beauty: usually wooded or unpastured area: water clarity exceptional Natural Area trees and/or native vegetation common; some development evident (from fields, pastures, dwellings); water clarity discolored Common Setting: not offensive, developed but uncluttered; water may be colored or turbid Offensive: stream does not enhance aesthetics: cluttered; highly developed; dumping areas; water discolored Worksheet4.0, TNRCC-10055 (Revised 12101)
Page 4-2
WORKSHEET 5.0 - SEWAGE SLUDGE MANAGEMENT AND DISPOSAL THE FOLLOWING IS REQUIRED FOR ALL TPDES PERMIT APPLICATIONS THAT MEET THE CONDITIONS AS OUTLINED IN TECHNICAL REPORT 1.0, ITEM NO. 7.
- 1.
SEWAGE SLUDGE SOLIDS MANAGEMENT PLAN (Instructions, Page 50)
- a.
Is this a new permit application or an amendment permit application?
Yes I
No
- b.
Does the facility discharge in the Lake Houston watershed?
Yes v/
No If yes to either item a or b, indicate by a check mark that a solids management plan was provided with the application.
- 2.
SEWAGE SLUDGE MANAGEMENT AND DISPOSAL (Instruction, Page 50)
- a.
Please check the current sludge disposal method(s). More than one method can be checked.
Permitted landfill Marketing and distribution by the permittee v! Registered land application site
___Composted by the permittee Surface disposal site (sludge monofill)
Transported to another WWTP (written statement or contractual agreement required)
Beneficial land application as authorized in the existing permit
- b.
Disposal site name, TNRCC Permit/Registration Number and County where disposal site is located:
STP Nuclear Operating Company Beneficial Land Use Site, No. 04523. Matanorda C.
Method of Transportation (truck, train, pipe, other) and hauler Registration Number:
Vacuum trucic Sewage sludge does not leave the STP Nuclear Operating Company property.
Transported in:
liquid i/
semi-liquid semi-solid solid state Land application for:
Reclamation
_Soil Conditioning
- d.
If the existing permit contains authorization for sludge land application, composting, marketing and distribution of sludge, and/or sludge lagoons and authorization to renew the activity is being sought in the application, the appropriate sections of the Sludge Technical Renort must be provided.
- 3.
PERMIT AUTHORIZATION FOR SEWAGE SLUDGE DISPOSAL (Instructions, Page 51)
Are you requesting new authorization to beneficially land apply sewage sludge at this site or a site under your direct control?
Yes V
No Are you requesting new authorization to market and distribute sewage sludge at this facility or a facility under your direct control?
Yes
/
No Are you requesting new authorization to compost sewage sludge?
Yes of No Are you requesting new authorization to surface dispose sewage sludge at this site or site under your direct control?
Yes I
No Are you requesting new authorization to incinerate sewage sludge at this site or site under your direct control?
Yes I
No If yes to any of the above items, provide the information required in the SLUDGE TECHNICAL REPORT.
New authorization for beneficial land application, incineration, and sludge lagoons in the TPDES or TLAP permits requires a maior amendment to the permit. New authorization for composting may require a major amendment to the permit. See the instructions for an explanation whether a major amendment is required or if authorization for composting can be added through the renewal process.
Worksheet 6.0, TNRCC-10055 (Revised 12101)
Page 5-1
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX AR-5g FIGURE 1 OF 6 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-01
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX AR-5g FIGURE 2 OF 6 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-02
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX AR-5g FIGURE 3 OF 6 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-03
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX AR-5g FIGURE 4 OF 6 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-04
Banks Water Well Repo rt gi Information Solutions, Inc.
DETAILS State ID Banks ID Ii Owner Of Well i
Type Of Well Depth Drilled Completion Date Longitude 80-16-801 4832100373 H. A. Norris Stock 130' 1/1/1962
-96.04194 28.78806 MAP ID
,-I Latitude State ID 80-16-6B Banks ID 4832101141 Owner Of Well Spaw Glass Type Of Well Domestic Depth Drilled 660' Completion Date 2/21/1985 Longitude
-96.03729._
Latitude 28.79428 State ID G1 610103B Banks ID 4832100721 Owner Of Well H L & P-SOUTH TEXAS PROJECT - NTF Type Of Well Inactive Depth Drilled N/A' Completion Date 3/22/1991 Longitude
-96.03889 Latitude 28.78917 P.O. Box 12851, Capitol Station, Austin, TX 78711 700 N. Lamar, Suite 200 Austin, TX 78703 512.478.0059 FAX 512.478.1433 e-mail banks@banksinfo.com Copyright 1998 by Banks Information Solutions, Inc.
c -of
Banks Water Well Repo rt Information Solutions, Inc.
DETAILS State ID Banks ID
--Owner Of Well Type Of Well Depth Drilled Completion Date Longitude 80-24-302 4832100424 Southern Minerals Corp Other N/A' 1/l/1 962
-96.00722 28.74472 I MAP ID I MAP ID 2
Latitude State ID Banks ID Owner Of Well Type Of Well Depth Drilled Completion Date Longitude Latitude 80-16-9 4832101152 Two River Cattle Co.
Domestic 130' 11/21/2001
-96.00105 28.7547 State ID Banks ID Owner Of Well Type Of Well Depth Drilled Completion Date Longitude 80-16-9 4832101153 Two River Cattle Co.
Domestic 130' 11/21/2001
-96.00101 28.75478
-- 4 I-Latitude P.O. Box 12851, Capitol Station, Austin, TX 78711 700 N. Lamar, Suite 200 Austin, TX 78703 512.478.0059 FAX 512.478.1433 e-mail banks@banksinfo.com Copyright 1998 by Banks Information Solutions, Inc.
BanksTM
\\ -Banks Water Well Report Information Solutions, Inc.
DETAILS State ID Banks ID Owner Of Well Type Of Well Depth Drilled Completion Date Longitude Latitude 80-16-9 4832101154 Two River Cattle Co.
Domestic 130' 11/21/2001
-96.00113 28.75478 MAP ID 2
State ID Banks ID Owner Of Well Type Of Well 81-17-1 4832101171 Jane Cox Domestic 140' 8/1 5/1 999___
-95.99007 28.74351 Depth Drilled Comnletion Date Longite-Latitude In State ID Banks ID X
Owner Of Well Type Of Well Depth Drilled Completion Date Longitude 80-16-903 4832100621 Exotic Isle Subd.
Public Supply 548_
9/5/1984
-96.00111 28.75917 MAP ID I
Latitude
'a P.O. Box 12851, Capitol Station, Austin, TX 78711 700 N. Lamar, Suite 200 Austin, TX 78703 512.478.0059 FAX 512.478.1433 e-mail banks@banksinfo.com Copyright 1998 by Banks Information Solutions, Inc.
BanksTM D
Banks Water Well Report Information Inc._
DETAILS i_ XSolutions, Inc.
DETAILS State ID Banks ID Owner Of Well Type Of Well Depth Drilled Completion Date Longitude Latitude State ID Banks ID Owner Of Well Type Of Well Depth Drilled Completion Date Longitude Latitude 8950 4832101176-Exotic Isle Home Owners Association Public Supply 430' '___
3/20/2002
-96.0014 28.75982 MAP ID
_4 G1610027B 4832100669 SELKIRK WATER Public Supply 800' 1/1/1971 MAP ID
.,I
-95.99861 28.76111 P.O. Box 12851, Capitol Station, Austin, TX 78711 700 N. Lamar, Suite 200 Austin, TX 78703 512.478.0059 FAX 512.478.1433 e-mail banks@banksinfo.com Copyright 1998 by Banks Information Solutions, Inc.
BanksTM Bormationk Water Well Report Solutions, Inc.
SUMMARY
Water Well Report Tiesearch Mapping Protocol The Banks Information Solutions, Inc. Water Well Report is prepared from existing state water well databases and additional file datalrecords research conducted at Texas' regulatory authorities. Submission of drilleres log records upon completion of a drilled water well became mandatory In 1985. The state of Texas has processed these records Into several different filing systems within two state regulatory authorities. The water well files, records and map locations are maintained by the Texas Commission on Environmental Quality (TCEQ) and the Texas Water Development Board (TWDB). Actual water well site locations of this report are geocoded and geoplotted directly from the drilling records, drilling schedules, and driller's logs and maps submitted by the water well driller and maintained at these two primary water well regulatory authorities. Below Is a description of the four filing systems utilized for well drilling records.
Texas Water Development Board (TWDB)
Texas Water Development Board maintains a file system of located water well locations. These well files are water well site locations that have been verified with a field Inventory Inspection by TWDB personnel. The wells are assigned a State Identification Number unique to that well and plotted on county base maps, U.S.G.S. 7.5 minute topographical quadrangle maps, and in-house geographic Information system. Records will also Include analytical data attached with each drilling record. This Is the current protocol for maintaining water well records within the TWDB.
Texas Commission on Environmental Quality (TCEQ)
The Texas Commission on Environmental Quality maintains a file system of plotted, partially numbered, and un-numbered water well locations. Plotted water well files are water well site locations that have been determined from map Information submitted on water well logs and subsequently plotted on TWDB county highway base maps. This type of mapping and filing procedure ceased In June 1986. Partially numbered water well files are water well site locations processed from 1986 through 1990. These wells are provided a State Identification Number which establishes the well location somewhere within a 2.5 minute quadrant of a 7.5 minute quadrangle map, but the site location has never been precisely mapped or verified by a State of Texas staff member. Un-numbered water well files are water well site locations that have been processed since June 1990. These well records are filed solely on their county location and are not provided a State Identiflation Number nor are they mapped. This Is the current protocol for maintaining water well records within the TCEQ.
Disclaimer Banks Information Solutions, Inc. has performed a thorough and diligent search of all wells recorded with the Texas Water Development Board and the Texas Commission on Environmental Quality. All mapped locations are based on Information obtained from the TWDB and the TCEQ. Although Banks performs quality assurance and quality control on all research projects, we recognize that any Inaccuracies of the records and mapped well locations could possibly be traced to the appropriate regulatory authority or the water well driller. Many water well schedules may have never been submitted to the regulatory authority by the water well driller and, thus, may explain the possible unaccountability of private drilled wells. It Is uncertain If the above listing provides 100% of the existing well locations within the area of review. Therefore, Banks Information Solutions, Inc. cannot gaurantee the accuracy of the data or well location(s) of those maps and records maintained by Texas' regulatory authorities.
P.O. Box 12851, Capitol Station, Austin, TX 78711 700 N. Lamar, Suite 200 Austin, TX 78703 512.478.0059 FAX 512.478.1433 e-mail banks@banksinfo.com Copyright 1998 by Banks Information Solutions, Inc.
APPENDIX TR-lc Cross Reference-Technical Report, Page 1, Part 1.c.
l.e. Describe the wastewater generating process.
Wastewater is produced at the South Texas Project Electric Generating Station through several processes necessary for electricity generation.
Main Cooling Reservoir (Outfall 001)
Outfall 001 has not discharged since March 1997 other than minor permitted leakage through the closed spillway gates.
Blowdown from the 7,000-acre main cooling reservoir would make up the largest percentage of wastewater if a reservoir discharge were to occur. This reservoir is part of the main recirculating cooling water loop used to remove heat from the two steam-electric generating units. Water from the reservoir would be discharged through Outfall 001 to Colorado River Tidal - Stream Segment 1401. Again, Outfall 001 has not discharged since March 1997. Because no discharge has occurred since then, no sampling data was provided with this application. Reference Appendix TR-2b Figure 1 of 6 for a simplified flow diagram.
All internal outfalls (Outfall 101, 201, 401, and 601) discharge to the main cooling reservoir. Outfall 501 would also discharge to the reservoir via Outfall 101, but has not discharged since 1992. These internal outfalls discharge from the various systems described below and within this permit application.
Reference Appendix TR-2b Figures 1 through 6.
Low Volume Wastewater (Outfalls 101 and 201)
Low volume wastewater results from water treatment operations, boiler blowdown, HVAC blowdown, floor drains and SPCC sources and their associated oily water treatment system discharges, and other miscellaneous sources. Boiler blowdown is water from the one-auxiliary steam boiler that is released to reduce concentrations of impurities in the water that would cause corrosion and boiler tube failure.
Demineralizer regeneration wastewater results from demineralizing service water to purify and treat it before being used in plant systems. Regeneration of the demineralizer resin beds produces an acidic and caustic wastewater that is treated at the neutralization basins along with boiler blowdown. The floor drain system captures condensate and water from production and maintenance areas that have the potential to have oil or grease contamination. The water is then transported to the oily waste treatment system where the oil is separated from the water. The first flush of stormwater from some production and storage areas is also treated in the oily waste system with other non-process stormwater flow directed through the designated stormwater outfills. Reference Appendix TR-2b Figures 2 and 3 of 6.
Treated Domestic Wastewater (Outfalls 401 and 601)
Domestic wastewater is treated on-site in two package treatment systems consisting of aeration, clarification, and disinfection. Car wash water, air conditioning condensate, and HVAC cooling tower blowdown are commingled with the domestic wastewater prior to treatment. Reference Appendix TR-2b Figures 4 and 5 of 6.
Metal Cleaning Waste (Outfalls 501)
Metal cleaning waste has not been discharged since 1992. Cleaning of metal using chemical or non-chemical liquids produces a waste that would be discharged through Outfall 501 to the neutralization basins (Outfall 101). Reference Appendix TR-2b Figure 2 of 6.
Page 1 of 1
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX SPIF-8.8 FIGURE 1 OF 3 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-05
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX SPIF-8.8 FIGURE 2 OF 3 "USGS TOPOGRAPHIC MAP" WITHIN THIS PACKAGE D-06 ta
THIS PAGE IS AN OVERSIZED DRAWING OR
- FIGURE, THAT CAN BE VIEWED AT THE RECORD TITLED:
APPENDIX TR-le FIGURE 2 OF 2 "FACILITY MAP" WITHIN THIS PACKAGE D-07
APPENDIX TR-2a Cross Reference Technical Report - Page 3, Part 2.a.
2.a.
List any physical, chemical, and/or biological treatment processes that you use for the treatment of wastewater at your facility. Include a description of each treatment process starting with initial treatment and finishing with the discharge point.
System and Outfall Unit Dimensions Processes Main Cooling Reservoir Heat Dissipation Outfall 001 7,000 acre pond (irregular)
Reuse/Recycle Low Volume Waste 2-Neutralization Basins Neutralization*
Neutralization Basin (300,000 gallons each)
Mixing*
Outfall 101 68' x 42' x 16' Sedimentation Metal Cleaning Waste Organic Basin Equalization Routed to Outfall 101 Approx. 1,000,000 gallons Mixing*
100' x 80' x 17'6" Aeration*
Inorganic Basin Coagulation*
Approx. 40,000 gallons Chemical Precipitation*
25' x 25' x 13'3" Sedimentation Gross Oil Separator (API)
Equalization Low Volume Waste 13,000 gallons Flotatio Oily Waste Treatment System 24" x 8' x 7' Skimnming*
Outfall 201 Sedimnentation Tricellerator (DAF) 3,800 gallons Dissolved air flotation 9' dia x 8' Coagulation*
Effluent Tank 850 gallons Mul-media Filtration 5' dia x 6' Sanitary Waste Treatment System**
2-Aeration Basn Screening Outfall 401 63" x 12" xl 1 '6" Activated Sludge 2 Clarifiers 16' dia x 11 '6" Sedimentation Primary Chlorine Contact Chamber Disinfection 6" x 12' x 1 I'6" Secondary Chlorine Contact Chamber Disinfection 4' dia x 4'3" Note: Chlorine may be used intermittently to control algae growth in treatment units.
Treatment process may be used based on influent characteristics.
Chlorine is used to treat domestic sewage prior to discharge.
TR-2a Page I of 2
System and Outfall Unit Dimensions Processes Metal Cleaning Waste rganic Basin Equalization OetfalClea501 WseApprox.
1,000,000 gallons Mixing*
100'x 80'x 17'6" Aeration*
Inorganic Basin Coagulation*
Approx. 40,000 gallons Chemical Precipitation*
25' x 25' x 13'3" Sedimentation Sanitary Waste Treatment Systemn" 2-Aeration Basins Screening Outfall 601 54'6" x 12' x 13'3" Activated Sludge 1-ClarifierSeintio 20' dia x 13'3" Sedimentation Chlorine Contact Chamber Disinfection Note: Chlorine may be used intermittently to control algae growth in treatment units.
Treatment process may be used based on influent characteristics.
Chlorine is used to treat domestic sewage prior to discharge.
TR-2a Page 2 of 2
(
(
(
Recirculated Main Condenser Cooling Water Previously Monitored Effluent from Outfalls 101. 201, 401, 501,** and 601 NRC Regulated Flows h
MAIN COOLING RESERVOIR Heat Dissipation
- Reuse/Recycle
' "X 0' ' u','', ",'
To Colorado River Outfall 001 Flowv. Temp, TRC, pH 0.000 MGD ^
Blowdown from Essential Cooling Reservoir APPENDIX TR - 2b Figure 1 of 6 SkirplHed Process Flow Diagram.
Oufall 001 Previously Monflwed Efiuents and Sbofmwater Notes:
Ouffall has not discharged since March 4, 1997.
Outfall has not discharged since Decemrber 1992.
SouhToms P,*
Eed,4 O.MuW0q 9tw J1~VVPFfPTWM 200COM MW2*
1cEO Po"~ N& 0108 mew 200 i0
(
(
(
Low Volume Wastewater including wastewater from the following operations and sources:
demineralizer regenerant wastewater, condenser polishing regenerant wastewater; boiler blowdown; boiler drainage; laboratory, instrument, and sampling sources; well water filter backwash; water softener regenerate; floor drains In chemical storage containment areas; rinse water from triple rinsing empty chemical drums; Fuel handling building HVAC blowdown and miscellaneous low volume wastewater.
recirculation line I-I NEUTRALIZATION BASINS 7
I 4&
P Natitallmatinn"*
I Outfall 101 Monk Point for I
Flow -. TSS, O&G, pH 1
0.28 MGD*
I to Main Cooling Reservoir Mixing*
Sedimentation sludge to landfill I
Metal Cleaning Waste Effluent from Organic and Inorganic Basins 1-Notes:
Intermittent discharge Two Year Average of the Daily Average Flows (1/102 to 12131/03)
Treatment may be used based on Influent quality APPENDIX TR -3 Figure Figure 2 of 6 SiWmlied P ss Flow Diagram Oufall 101 Low Voolume Wastewater Neutrelzaion Basin Treatnent System Saoi TM Pmod eftelut Ewe o
a t"
MPn S 20a0m TV Tems D.-
-- ess
(
(
Low Volume Wastewater Including wastewater from the following operations or sources:
wash down water; pump seal water; equipment leaks; and miscellaneous low volume wastewater SURGE TANK Equalization P.-
JA k
I Stormwater GROSS OIL SEPARATOR Flotation Skimming~
Sedimentallon Vacuum Fftloatlon 4
II sludge to incineration and/or landfill TRICELLERATOR Dissolved Air Floatation Coagulation***
Outfall 201 Flow *, TSS. 0&G 0.025 MGD-4-
To Main Cooling Reservoir FILTERS Multimedia Filtration filter media to landfill Notes:
APPENDIX TR -.3 5Im TCE0 PUIOMm 0190tsr Fgu 3 of 0
~bd Process Flow Dagrafm Out 201 LOw Vohwm Waster y Waste Tresatent System I
Wf 2O1P TN-b Muli2OO4 Inmi aent Flow Two Year Avera" of te Daily Averge Flows (1/1102 to 12/31/03)
Treatment piocess my be used based on kiued derecttrlstics
(
(
(
UEEEMNEN
-I Domestic I
Car Wash Water s r r
LIFT STATION Grinding [ I AERATION TANKS Activated Sludge Foam Suppression Screening 10 CLARIFIER Sedimentation 10 a
l I
I I _ - - -
I I
.4------
-a Ouffall 401 FIow*, TSS, BOD 0.022 MGD**
Sludge to landfill or land application
.4 - -
To Main Cooling Reservoir APPENDIX TR - 3 Figure 4 of 6 Notes:
Intemnitient Disdwrge Two Year Average of the Daily Average Flows (1/1/02 to 12/31/03)
Sui
!ed Pwcess Flow Diaram Outfall 401 Santary Wasts West Pnt Santary Wae Treatment System SibM TVm Eled0i emw" Sty I
t 200oes T raoPwON.t ewes 2m04 i
(
(
(
AERATION TANKS bCLAR A
Activaled Sludge Foam I
Suppression Screening Sedimer I
I I
I II I- -
I Outfall 601 Flow*, TSS, BOD 0.039MGD**
I To Main Cooling Reservoir APPENDIX TR - 3 Figure 5 of 6 Notes:
Intermitent Discharge Two Year Average of the Daily Aveage Flows (1/1102 to 12/31103)
Sh"ed Pmce Flow Dram outfall 601 Low Voue Wastewater NTFINSC Santary Waste Treatken System S8" To= EMOl Oww OMI j.Wrf#eNnIprMM pees 20OMSP T.t2 TCEa Pon*i wh Clow eat I
C
((
Evaporation from cooling reservoir & Impoundments Boiler Injection
-V/ /
Surface Water from the Colorado River 18.8 MGD Groundwater 1.03 MGD
- South Texas Project E.ectnc Generating Station.
Outfall 001 0.000 MGD '
I-Evaporation To Cooling Reservoir/
Colorado River
.[
Stormwater (volume unknown)
APPENDIX TR.3 Figue 6 of 6 Simpliied Water Balance Notes:
No discharge from this outfall ince March 4.1997 Two year average SCLtIhTWin E~edv Gw m "iu taft m J-t.
.,16oe T ~ 4 TVEO POOR Oft. 01506 MW 2006 I
Appendix TR-5c Cross Reference Technical Report, Part S.c., Page 8 Boiler Chemicals Additives These are products used as of May 2004 and are typical of the products anticipated to be used in the future. Products may be changed based on availability, cost, and effectiveness.
TR-5c Questions Product Code# 9226 Manufacture Product Number alco Chemical Inc Product Use ondensate corrosion Inhibitor Chemical Composition wI CAS #
thanolamine Product Classification Product Half-life Frequencv of Product Use Continuous to operating units condensate Toxict Data Product Concentration 1 ppM as product to the Feedwater TR-5cCuesionsProduct Code # 19-H Manufacture Product Number alco Chemical Product Use Oxvqen scavenger emical Composition w/ CAS #
ydrazine Product Classification Product Half-life Frequency of Product Use Continuous to operating unit's Feedwater Toxiity Data_
Product Concentration
.5 ppm to Feedwater Page 1 of 3
Appendix TR-Sc Cross Reference Technical Report, Part S.c., Page 8 Cooling Tower Chemical Additives These are products used as of May 2004 and are typical of the products anticipated to be used in the future. Products may be changed based on availability, cost, and effectiveness.
TR-Sc Ouestions lProduct Code# 9353 Manufacture Product Number alco Chemical urd:* Use Scle Inhibitor Ceical Composition w/ CAS #
olyacrvlate Pout Classification Pruct Half-life
__=
requency of Product Use Continuous to cooling water while unit in operation oxicity Data Lroduct Concentration e
rate is.25 ppm as product TR-5c Ouestions Product Code #7334 Manufacture Product Number alco Chemical Produc Use locide mical Composition w/ CAS #
ium Bromide Product Classification Product Half-life Frequency of Product Use Three times per day for 20 minutes to unit's cooling water oxicity Data Product Concentration 42 % solution added to sodium hypochlorite Injection stream TR-Sc Ouestions Product Code # 1359 plus Manufacture Product Number alco Chemical Product Use osed cooling system corrosion inhibitor emical Composition wI CAS b
itrite, borate, Tr Product Classification Product Half-life Frequency of Product Use Toxicity Data Product Concentration 0.25 oz. per gallon of dosed cooling system water Page 2 of 3
Appendix TR-5c Cross Reference Technical Report, Part 5.c., Page 8 Cooling Tower Chemical Additives (cont)
TR-Sc Ouestions Product Code # H-130M Manufacture Product Number alco Chemical Product Use nolluscidde mical Composition w/ CAS #
uatemary amine Product Classification Product Half-ife Frequency of Product Use Toxidity Data Product Concentration ppm as product (2.5 ppm as active) to auxiliary cooling system for B hours twice per year T iC-5-c Ouestions Manufacture Product Number
- via Product Use iodde Chemical Composition w/CAS#
ium Hypochlorite (7681-52-9), Sodium Hydroxide (1310-73-2) uct Classification uct Hallife Frequency of Product Use Three times per day for 20 minutes to units cooling water oxicity Data Product Concentration 10-120%
TR-5c Ouestions Manufacture Product Number arichem SC 2312 Product Use le and corrosion inhibitor mical Composition w/ CAS #
hoshonate/acrylate polymers Product Classification Product Half-life Frequency of Product Use nffnuous to office building cooling tower Toxicty Data Product Concentration 120 ppm TIR-Sc Questions Manufacture Product Number larichem Product Use
)H adjustment Chemical Composition w/ CAS S ulfuric acid (7664-93-9)
Product Classification Product Half-life Frequency of Product Use ontinuous to office building cooling tower Toxidty Data Product Concentratfon to maintain pH at approximatel 8.
Page 3 of 3
DNDEO Nalco MATERIAL SAFETY DATA SHEET, PRODUCT NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
- 1.
I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:
NALCO 9226 APPLICATION:
CORROSION INHIBITOR COMPANY IDENTIFICATION:
Ondeo Nalco Company Ondeo Nalco Center Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):
(800) 424-9300 (24 Hours)
CHEMTREC NFPA 704MWHMIS RATING HEALTH:
3 1 3 FLAMMABILITY:
1/1 INSTABILITY:
0/0 OTHER:
0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme
- 2.
l COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Monoethanolamine Hazardous Substance(s)
CAS NO 141-43-5
% (w/W) 60.0 - 100.0
- 3.
HAZARDS IDENTIFICATION
- EMERGENCY OVERVIEWS DANGER Corrosive. May cause tissue damage. Harmful if absorbed through skin. Large quantities may cause kidney and liver damage. Vapors may have a strong offensive odor which may cause sensory response including headache, nausea and vomiting.
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Keep container tightly closed and in a well-ventilated place. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.
Wear a face shield. Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.
May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin, Inhalation Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 1/10
Q MAItKIAL bAlt I I
UA I A brlt I
o<IIONDEO PRODUCT
- Nalco NALCO 9226 EMVERGENCY TELEPHONE NUMBER(S)*
(800) 424-9300 (24 Hours)
CHEMTREC HUMAN HEALTH HAZARDS - ACUTE:
EYE CONTACT:
Corrosive. Will cause eye bums and permanent tissue damage. Exposure to low vapor concentrations can result in foggy or blurred vision, objects appearing bluish and appearance of a halo around lights. These symptoms are temporary.
SKIN CONTACT:
May cause severe irritation or tissue damage depending on the length of exposure and the type of first aid administered. Harmful if absorbed through skin.
INGESTION:
Not a likely route of exposure. Corrosive; causes chemical bums to the mouth, throat and stomach.
INHALATION:
Irritating, in high concentrations, to the eyes, nose, throat and lungs. Vapors may have a strong offensive odor which may cause sensory response including headache, nausea and vomiting.
SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
N review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
- 4.
l FIRST AID MEASURES l
EYE CONTACT:
PROMPT ACTION IS ESSENTIAL IN CASE OF CONTACT. Immediately flush eye with water for at least 15 minutes while holding eyelids open. Get immediate medical attention.
SKIN CONTACT:
Immediately flush with plenty of water for at least 15 minutes. For a large splash, flood body under a shower.
Remove contaminated clothing. Wash off affected area immediately with plenty of water. Get immediate medical attention. Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use.
INGESTION:
DO NOT INDUCE VOMITING. If conscious, washout mouth and give water to drink. Get immediate medical attention.
INHALATION:
Remove to fresh air, treat symptomatically. Get medical attention.
NOTE TO PHYSICIAN:
Probable mucosal damage may contraindicate the use of gastric lavage. Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 2/10
0 0
MATERIAL SAFETY DATA SHEET o
ON D E O PRODUCT a
Nalco NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
- 5.
I FIRE FIGHTING MEASURES FLASH POINT:
208 OF 1 97.8 `C EXTINGUISHING MEDIA:
This product would not be expected to bum unless all the water is boiled away. The remaining organics may be ignitable. Use extinguishing media appropriate for surrounding fire. Keep containers cool by spraying with water.
FIRE AND EXPLOSION HAZARD:
May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit
- 6.
1 ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities.
M-,fETHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.
- 7.
l HANDLING AND STORAGE HANDLING:
Do not get in eyes, on skin, on clothing. Do not take internally. Do not breathe vapors/gases/dust. Use with adequate ventilation. Avoid generating aerosols and mists. Keep away from acids and oxidizing agents. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available.
STORAGE CONDITIONS:
Store the containers tightly closed. Store separately from acids. Store separately from oxidizers. Amine and sulphite products should not be stored within close proximity or resulting vapors may form visible airborne particles.
- 8.
l EXPOSURE CONTROLSIPERSONAL PROTECTION I
OCCUPATIONAL EXPOSURE LIMITS:
exposure guidelines have not been established for this product Available exposure limits for the substance(s) are hown below.
1-1 Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 3/10
0 0
<- ONDEO J -
NaCco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC ACGIH/TLV:
Substance(s)
Monoethanolamine OSHA/PEL:
Substance(s)
Monoethanolamine TWA 3 ppmr, 7.5 mglm3 STEL: 6 ppm, 15 mg/m3 TWA 3 ppm, 8 mg/m3 STEL: 6 ppm, 15 mg/m3 ENGINEERING MEASURES:
General ventilation is recommended. Use local exhaust ventilation if necessary to control airborne mist and vapor.
RESPIRATORY PROTECTION:
If significant mists, vapors or aerosols are generated an approved respirator is recommended. An organic vapor cartridge with dust/mist prefilter or supplied air may be used. In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.
HAND PROTECTION:
Butyl gloves, Most glove materials are of low chemical resistance. Replace gloves regularly.
SKIN PROTECTION:
Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended if gross exposure is possible.
EYE PROTECTION:
Wear a face shield with chemical splash goggles.
HYGIENE RECOMMENDATIONS:
Eye wash station and safety shower are necessary. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse.
HUMAN EXPOSURE CHARACTERIZATION:
Based on our recommended product application and personal protective equipment, the potential human exposure is: Low
- 9.
I PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE APPEARANCE ODOR Liquid Colorless Amine
'WPECIFIC GRAVITY I @ 77 F/25 °C Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 4/10
0 o,ONDEO OA *Nalco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC DENSITY 8.31 lb/gal SOLUBILITY IN WATER Complete pH (
13.8 VISCOSITY 42 SUS @ 100 0F / 37.8 °C POUR POINT
-30 0F I -34.3 °C BOILING POINT 266 OF / 130 0C Note: These physical properties are typical values for this product and are subject to change.
- 10.
I STABILITY AND REACTIVITY I
STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
None known MATERIALS TO AVOID:
Contact with strong acids (e.g. sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) may generate heat,
~,splattering or boiling and toxic vapors. Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Avoid contact with S02 or acidic bisulfite products, which may react to form visible airborne amine salt particles. Certain amines in contact with nitrous acid, organic or inorganic nitrites or atmospheres with high nitrous oxide concentrations may produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
Oxides of carbon, Oxides of nitrogen
- 11.
I TOXICOLOGICAL INFORMATION l
No toxicity studies have been conducted on this product SENSITIZATION:
This product is not expected to be a sensitizer.
CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
HUMAN HAZARD CHARACTERIZATION:
Based on our hazard characterization, the potential human hazard is: High Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 5/10
0 o :ONDEO eQ CA Nalco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
[12.
I ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
No toxicity studies have been conducted on this product ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: Moderate Based on our recommended product application and the product's characteristics, the potential environmental exposure is: Low If released into the environment, see CERCLA/SUPERFUND in Section 15.
113.
DISPOSAL CONSIDERATIONS I
If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, it should be determined if the waste meets the criteria of a hazardous waste.
Hazardous Waste: D002 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a
\\.properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements.
114.
1 TRANSPORT INFORMATION I
a The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
LAND TRANSPORT:
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
ETHANOLAMINE SOLUTION UN 2491 8
Ill Flash Point:
97.8 0C /208 0F AIR TRANSPORT (ICAO/IATA):
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
ETHANOLAMINE SOLUTION UN 2491 8
III Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 6/10
o MAITKIAL SAIEI Y DAIA bhI ON D E O
-PRODUCT aNao NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
I (800) 424-9300 (24 Hours)
CHEMTREC IATA Cargo Packing Instructions:
820 IATA Cargo Aircraft Limit:
60 L (Max net quantity per package)
MARINE TRANSPORT (IMDG/IMO):
Proper Shipping Name:
ETHANOLAMINE SOLUTION Technical Name(s):
UN/ID No:
UN 2491 Hazard Class - Primary:
8 Packing Group:
IlIl
- 15.
REGULATORY INFORMATION NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
Monoethanolamine: Corrosive, Combustible.
CERCLANSUPERFUND, 40 CFR 117, 302:
.otification of spills of this product is not required.
SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE l1l) - SECTIONS 302,311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
X Immediate (Acute) Health Hazard Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
'he substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 7/10
MATERIAL SAFETY DATA SHEET 0
0 o<'JONDEO PRODUCT Nalco NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC This product has been certified as KOSHER/PAREVE for year-round use INCLUDING THE PASSOVER SEASON by the CHICAGO RABBINICAL COUNCIL.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR / formerly Sec. 311:
None of the substances are specifically listed in the regulation.
CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
This product contains the following substances listed in the regulation:
Substance(s)
Citations Monoethanolamine Sec. 111 CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
MICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
K~-$TATE RIGHT TO KNOW LAWS:
The following substances are disclosed for compliance with State Right to Know Laws:
Monoethanolamine 141-43-5 NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
E - Corrosive Material CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
INTERNATIONAL CHEMICAL CONTROL LAWS AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS) and are listed on the Australian Inventory of Chemical Substances (AICS).
EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 8/10
MATERIAL SAFETY DATA SHEET ee DPRODUCT o*)2sONDEO NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Ministry of International Trade & industry List (MITI).
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
THE PHILIPPINES All substances in this product-comply with the Republic Act 6969 (RA 6969) and are listed on the Philippine Inventory of Chemicals & Chemical Substances (PICCS).
- 16.
OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product. Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:
'The human risk is: Low The environmental risk is: Low Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process.
This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insights CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 9/10
0 0
o a
DNDEO Nalco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9226 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Ariel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO.
Prepared By: Product Safety Department Date issued: 09/2512001 Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 10/10
)'NALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
X (800) 424-9300 (24 Hours)
CHEMTREC
- 1.
I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:
NALCO 19H APPLICATION:
OXYGEN SCAVENGER COMPANY IDENTIFICATION:
Ondeo Nalco Energy Services, L.P.
P.O. Box 87 Sugar Land, Texas 77487-0087 EMERGENCY TELEPHONE NUMBER(S):
(800) 424-9300 (24 Hours)
CHEMTREC NFPA 704MIHMIS RATING HEALTH:
2/2 FLAMMABILITY:
1/1 INSTABILITY:
0/0 OTHER:
0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme
- 2.
l COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)
Hydrazine CAS NO 302-01-2
% (wlw) 30.0 - 60.0
- 3.
l HAZARDS IDENTIFICATION
- EMERGENCY OVERVIEW**
DANGER This product contains hydrazine which is a suspect carcinogen. Extreme health hazard. May be absorbed through the skin. Risk of serious damage to eyes. Irritating to skin. May cause skin sensitization reaction in certain individuals. Harmful by inhalation, in contact with skin and if swallowed. This material or some of its substance(s) has been shown to cause cancer in laboratory animals. Toxic to aquatic organisms.
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Keep container tightly closed and in a well-ventilated place. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.
Wear a face shield. Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.
May evolve oxides of nitrogen (NOx) under fire conditions. May evolve toxic gases or fumes under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin, Inhalation HUMAN HEALTH HAZARDS -ACUTE:
EYE CONTACT:
Severely irritating. If not removed promptly, will injure eye tissue and may result in permanent eye damage.
Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 1/11
MATERIAL SAFETY DATA SHEET NALCO PRODUCT rNALCO NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC SKIN CONTACT:
Can cause moderate to severe irritation. May cause sensitization by skin contact INGESTION:
Not a likely route of exposure. There may be irritation to the gastrointestinal tract with nausea and vomiting.
INHALATION:
Vapors extremely irritating to eyes and respiratory tract. Can cause pulmonary edema. May cause liver and kidney disorder and/or damage.
SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
HUMAN HEALTH HAZARDS - CHRONIC:
Oral administration of hydrazine has produced lung and liver tumors in mice and rats and mammary tumors in mice.
Inhalation of hydrazine has produced nasal tumors in rats.
(4.
FIRST AID MEASURES EYE CONTACT:
Immediately flush eye with water for at least 15 minutes while holding eyelids open. Get immediate medical attention.
SKIN CONTACT:
Remove contaminated clothing. Wash off affected area immediately with plenty of water. Get immediate medical attention. Contaminated clothing, shoes, and leather goods must be discarded or cleaned before re-use.
INGESTION:
Induce vomiting if the patient is fully conscious. If conscious, washout mouth and give water to drink. Get immediate medical attention.
INHALATION:
Remove to fresh air, treat symptomatically. Get medical attention.
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
I5.
I FIRE FIGHTING MEASURES FLASH POINT:
> 230 OF I > 110 `C (PMCC)
Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 2/11
MATERIAL SAFETY DATA SHEET N ALCO-PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424.9300 (24 Hours)
CHEMTREC EXTINGUISHING MEDIA:
Not expected to bum. Use extinguishing media appropriate for surrounding fire.
FIRE AND EXPLOSION HAZARD:
May evolve oxides of nitrogen (NOx) under fire conditions. May evolve toxic gases or fumes under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit A_6.
ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS: LARGE SPILLS: Dike to prevent further movement. Reclaim into recovery or salvage drums.
Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal
'Considerations).
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.
- 7.
l HANDLING AND STORAGE l
HANDLING:
Do not get in eyes, on skin, on clothing. Do not take intemally. Use with adequate ventilation. Avoid generating aerosols and mists. Keep the containers closed when not in use. Have emergency equipment (for fires, spills, leaks, etc.) readily available.
STORAGE CONDITIONS:
Store the containers tightly closed. Store separately from oxidizers. Store in suitable labelled containers.
SUITABLE CONSTRUCTION MATERIAL:
Polypropylene, Polyethylene, Stainless Steel 304, Stainless Steel 316L, Compatibility with Plastic Materials can vary; we therefore recommend that compatibility is tested prior to use.
UNSUITABLE CONSTRUCTION MATERIAL:
- 8.
l EXPOSURE CONTROLSIPERSONAL PROTECTION I
OCCUPATIONAL EXPOSURE LIMITS:
Exposure guidelines have not been established for this product Available exposure limits for the substance(s) are iown below.
Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 3/11
PNALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hours)
CHEMTREC ACGIH/TLV:
Substance(s)
Hydrazine OSHANPEL:
Substance(s)
Hydrazine TWA 0.01 ppm, 0.013 mg/m3 (Skin)
TWA: 0.1 ppm, 0.1 mg/m3 (Skin)
ENGINEERING MEASURES:
General ventilation is recommended. Use local exhaust ventilation if necessary to control airborne mist and vapor.
RESPIRATORY PROTECTION:
Where concentrations in air may exceed the limits given in this section, the use of a half face filter mask or air supplied breathing apparatus is recommended. A suitable filter material depends on the amount and type of chemicals being handled. Consider the use of filter type: Ammonia / amine cartridge (Green) with a Particulate pre-filter (Purple). In event of emergency or planned entry into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.
HAND PROTECTION:
mpervious gloves SKIN PROTECTION:
Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots. A full slicker suit is recommended if gross exposure is possible.
EYE PROTECTION:
Wear a face shield with chemical splash goggles.
HYGIENE RECOMMENDATIONS:
Eye wash station and safety shower are necessary. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse.
- 9.
l PHYSICAL AND CHEMICAL PROPERTIES l
PHYSICAL STATE APPEARANCE ODOR Liquid Colorless Ammoniacal SPECIFIC GRAVITY DENSITY SOLUBILITY IN WATER pH (100 %)
pH (1 %)
'ISCOSITY 1.03 @ 60°F/15.6tC 8.56 lb/gal Complete 12.5 10.1 - 10.7 2.0 cps @ 60 °F 115.6 °C Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 4/11
^tNALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
_____I (800) 424-9300 (24 Hours)
CHEMTREC FREEZING POINT
-85 OF / -65 0C BOILING POINT 228 ¶F / 108.9 °C VAPOR PRESSURE 22 mm Hg @ 77 'F /25 0C Note: These physical properties are typical values for this product and are subject to change.
- 10.
I STABILITY AND REACTIVITY l
STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
Heat MATERIALS TO AVOID:
Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
<_Jnder fire conditions:
Oxides of nitrogen 111.
TOXICOLOGICAL INFORMATION
-1 a
The following results are for the product ACUTE ORAL TOXICITY:
Species LD50 Rat 185 mg/kg ACUTE DERMAL TOXICITY:
Species LD50 Rabbit 420 mglkg ACUTE INHALATION TOXICITY:
Species LC50 Rat 2.1 mgAI (4 hrs)
Test Descriptor Product Test Descriptor Product Test Descriptor Product SENSITIZATION:
May cause sensitization by skin contact. Repeated or prolonged contact may cause sensitization in some individuals.
CARCINOGENICITY:
This product contains hydrazine. The International Agency for Research on Cancer(IARC) has evaluated hydrazine, and found it to be a possible human carcinogen (Group 2B) based on sufficient animal data and inadequate human lata.
Ondeo Nalco Energy Services, LP. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 5/11
P"NALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC HUMAN HAZARD CHARACTERIZATION:
Based on our hazard characterization, the potential human hazard is: High
- 12.
l ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
The following results are for the product.
ACUTE FISH RESULTS:
Species Exposure l LC50 Test Descriptor Bluegill Sunfish 96 hrs 4.2 mg/I Product Rainbow Trout 96 hrs 4.3 mg/I Product Gold Orfe 96 hrs 0.75 mg/l Product Rating: Toxic ACUTE INVERTEBRATE RESULTS:
Species Exposure LC50 EC50 Test Descriptor Daphnia magna 48 hrs 0.46 mg/I Product Daphnia magna 48 hrs 0.81 mg/I Product Rating: Very toxic MOBILITY:
The environmental fate was estimated using a level IlIl fugacity model embedded in the EPI (estimation program interface) Suite TM, provided by the US EPA. The model assumes a steady state condition between the total input and output. The level IlIl model does not require equilibrium between the defined media. The information provided is intended to give the user a general estimate of the environmental fate of this product under the defined conditions of the models. If released into the environment this material is expected to distribute to the air, water and soil/sediment in the approximate respective percentages; I
Air I
Water I
Soil/Sediment I
l
<5%
l 30 - 50%
l 50 - 70%
l The portion in water is expected to be soluble or dispersible.
BIOACCUMULATION POTENTIAL This preparation or material is not expected to bioaccumulate.
ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: Moderate If released into the environment, see CERCAIASUPERFUND in Section 15.
Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 6/11
P"NALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H v
EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hour)
CHEMTREC 1 13.
l DISPOSAL CONSIDERATIONS I
If this product becomes a waste, it could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, it should be determined if the waste meets the criteria of a hazardous waste.
Hazardous Waste: D002, U133 Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements.
- 14.
l TRANSPORT INFORMATION I
The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
LAND TRANSPORT:
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
HYDRAZINE, AQUEOUS SOLUTION UN 3293 6.1 Ill Flash Point:
> 110°C/>230OF DOT Reportable Quantity (per package):
2 lbs HYDRAZINE AIR TRANSPORT (ICAOI1ATA):
Proper Shipping Name:
Technical Name(s):
UNIID No:
Hazard Class - Primary:
Packing Group:
IATA Cargo Packing Instructions:
IATA Cargo Aircraft Limit:
HYDRAZINE, AQUEOUS SOLUTION UN 3293 6.1 III 618 220 L (Max net quantity per package)
MARINE TRANSPORT (IMDGIIMO):
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
HYDRAZINE, AQUEOUS SOLUTION UN 3293 6.1 Ill Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 7 /11
MATERIAL SAFETY DATA SHEET VNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC
- 15.
I REGULATORY INFORMATION NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
Hydrazine: Cancer suspect agent (refer to Section 3), Corrosive, Dermal Sensitizer CERCLNSUPERFUND, 40 CFR 117, 302:
This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product RQ Substance RQ Hydrazine 2 lbs SARANSUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE 1II) - SECTIONS 302,311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product contains the following substance(s) which is listed in Appendix A and B as an Extremely Hazardous Substance. Listed below are the statutory Threshold Planning Quantity (TPQ) for the substance(s) and the Reportable Quantity (RQ) of the product. If a reportable quantity of product is released, it requires notification to your State Emergency Response Commission. You may also be required to notify the National Response Center -
See CERCLAISUPERFUND, above.
Extremely Hazardous Substance TPQ RO Hydrazine 1,000 lbs 2 lbs SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
X Immediate (Acute) Health Hazard X
Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product contains the following substance(s), (with CAS # and % range) which appear(s) on the List of Toxic Chemicals Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 8/11
AWNALCO MATERIAL SAFETY DATA SHEET PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)-
(800) 424-9300 (24 Hours)
CHEMTREC Hazardous Substance(s)
Hydrazine CAS NO 302-01-2
% (wvw) 30.0 - 60.0 TOXIC SUBSTANCES CONTROL ACT (TSCA):
The substances in this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
FOOD AND DRUG ADMINISTRATION (FDA) Federal Food, Drug and Cosmetic Act:
When use situations necessitate compliance with FDA regulations, this product is acceptable under: 21 CFR 173.310 Boiler Water Additives The following limitations apply:
Maximum dosage 0
Limitation in the steam.
Limitations: no more than required to produce intended technical effect NSF NON-FOOD COMPOUNDS REGISTRATION PROGRAM (former USDA List of Proprietary Substances & Non-Food Compounds)::
NSF Registration number for this product is: 062465 This product is acceptable for use in meat, poultry, and other food processing areas as a Boiler Treatment Product (G6), for treating boiler and steam lines where the steam produced may contact edible products. Acceptable usage
,hall be in accordance with the dosage limitations specified on the product label.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4 / formerly Sec. 311:
None of the substances are specifically listed in the regulation.
CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
This product contains the following substances listed in the regulation:
Substance(s)
Citations
- Hydrazine lSec. 112 CALIFORNIA PROPOSITION 65:
This product contains the following substances which require warning under California Proposition 65.
Substance(s)
Concentration EFFECTS Hydrazine 60 %
Causes Cancer MICHIGAN CRITICAL MATERIALS:
This product contains the following substances listed in the regulation:
Hydrazine Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 9/11
MATERIAL SAFETY DATA SHEET WNALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC STATE RIGHT TO KNOW LAWS:
The following substances are disclosed for compliance with State Right to Know Laws:
Hydrazine 302-01-2 NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
D2B - Materials Causing Other Toxic Effects -Toxic Material CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
INTERNATIONAL CHEMICAL CONTROL LAWS AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme
'NICNAS) and are listed on the Australian Inventory of Chemical Substances (AICS).
EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Ministry of International Trade & industry List (MITI).
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
THE PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippine Inventory of Chemicals & Chemical Substances (PICCS).
- 16.
l OTHER INFORMATION This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Ondeo Nalco Energy Services, L.P. P.O. Box 87
- Sugar Land, Texas 77487-0087 (281)263-7000 10/11
MATERIAL SAFETY DATA SHEET.
)0 NALCO PRODUCT NALCO 19H EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hour)
CHEMTREC Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
riel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
Asorth American Module, Westem European Module, Chemical Inventories Module and the Generics Module (Ariel Insightff CD-ROM Version), Ariel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO.
Prepared By: Product Safety Department Date issued: 0512712003 Replaces: 05116/2002 Ondeo Nalco Energy Services, L.P. P.O. Box 87 - Sugar Land, Texas 77487-0087 (281)263-7000 11 1 11
0 of< ONDEO a
Natco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC l 1.
I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION I
PRODUCT NAME:
APPLICATION:
CHEMICAL DESCRIPTION:
COMPANY IDENTIFICATION:
EMERGENCY TELEPHONE NUMBER:
NFPA 704M/HMIS RATING HEALTH:
0/1 FLAMMABILITY:
1 11 0 = Insignificant I = Slight 2 = Moderate 3 =
NALCO 9353 SCALE INHIBITOR/DISPERSANT Water, Acrylate polymer(s)
ONDEO Nalco Company ONDEO Nalco Center Naperville, Illinois 60563-1198 (800) 424-9300 (24 Hours)
CHEMTREC REACTIVITY:
High 4 = Extreme 0/0 OTHER:
- 12.
1 COMPOSITIONIINFORMATION ON INGREDIENTS l
Based on our hazard evaluation, none of the substances in this product are hazardous.
13-l HAZARDS IDENTIFICATION i
I
- EMERGENCY OVERVIEW*
CAUTION May cause irritation with prolonged contact Do not get in eyes, on skin, on clothing. Do not take internally. Wear suitable protective clothing. Keep container tightly closed. Flush affected area with water.
May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) and sulfur (SOx) under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:
EYE CONTACT:
May cause irritation with prolonged contact SKIN CONTACT:
May cause irritation with prolonged contact INGESTION:
lot a likely route of exposure. No adverse effects expected.
ONDEO Nalco Company ONDEO Nalco Center-Naperville, Illinois 60563-1198 (630)305-1000 1/8
0 0
o<AONDEO C
Natco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hour)
CHEMTREC INHALATION:
Not a likely route of exposure. No adverse effects expected.
SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not Identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
- 4.
FIRST AID MEASURES EYE CONTACT:
Flush affected area with water. If symptoms develop, seek medical advice.
SKIN CONTACT:
Flush affected area with water. If symptoms develop, seek medical advice.
INGESTION:
)o not induce vomiting without medical advice. If conscious, washout mouth and give water to drink. If symptoms develop, seek medical advice.
INHALATION:
Remove to fresh air, treat symptomatically. If symptoms develop, seek medical advice.
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
- 5.
l FIRE FIGHTING MEASURES FLASH POINT:
> 212 0F / > 100 eC ( PMCC)
EXTINGUISHING MEDIA:
This product would not be expected to bum unless all the water is boiled away. The remaining organics may be ignitable. Use extinguishing media appropriate for surrounding fire.
FIRE AND EXPLOSION HAZARD:
May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) and sulfur (SOx) under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 2/8
MATERIAL SAFETY DATA,5
.oe' qf O
D-PRODUCT O
- NDEO NALCO 9353 EMERGENCY TELEPHONE NUMBER MHEET (800) 424-9300 (24 Hous)
CHEMTREC
- 6.
l ACCIDENTAL RELEASE MEASURES I
PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Stop or reduce any leaks if it is safe to do so. Do not touch spilled material. Ventilate spill area if possible. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.
- 17.
l HANDLING AND STORAGE HANDLING:
Avoid eye and skin contact. Do not take internally. Ensure all containers are labelled. Keep the containers closed when not in use.
STORAGE CONDITIONS:
Store the containers tightly closed.
- 18.
l EXPOSURE CONTROLSIPERSONAL PROTECTION I
OCCUPATIONAL EXPOSURE LIMITS:
This product does not contain any substance that has an established exposure limit.
ENGINEERING MEASURES:
General ventilation is recommended.
RESPIRATORY PROTECTION:
Respiratory protection is not normally needed.
HAND PROTECTION:
Neoprene gloves, Nitrile gloves, Butyl gloves, PVC gloves SKIN PROTECTION:
Wear standard protective clothing.
EYE PROTECTION:
Wear chemical splash goggles.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 3/8
0 o<
ONDEO j C Natco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC HYGIENE RECOMMENDATIONS:
Keep an eye wash fountain available. Keep a safety shower available. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse.
HUMAN EXPOSURE CHARACTERIZATION:
Based on our recommended product application and personal protective equipment, the potential human exposure is: Moderate
- 19.
l PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Colorless ODOR None SPECIFIC GRAVITY 1.23 - 1.29 @ 77 -F /25 0C SOLUBILITY IN WATER Complete pH (100 %)
3 VISCOSITY 275 cps FREEZING POINT
-50 0F 1 -45 °C T0.
I STABILITY AND REACTIVITY I
STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
Freezing temperatures.
MATERIALS TO AVOID:
Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Contact with strong alkalies (e.g. ammonia and its solutions, carbonates, sodium hydroxide (caustic), potassium hydroxide, calcium hydroxide (lime), cyanide, sulfide, hypochlorites, chlorites) may generate heat, splattering or boiling and toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
Oxides of carbon, Oxides of nitrogen, Oxides of sulfur I 11.
I TOXICOLOGICAL INFORMATION I
No toxicity studies have been conducted on this product ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 4/8
0 0 a
DNDEO Natco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMITREG CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
HUMAN HAZARD CHARACTERIZATION:
Based on our hazard characterization, the potential human hazard is: Low 112.
l ECOLOGICAL INFORMATION I
a ECOTOXICOLOGICAL EFFECTS:
No toxicity studies have been conducted on this product.
ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: Low Based on our recommended product application and the product's characteristics, the potential environmental exposure is: High If released into the environment, see CERCLAISUPERFUND in Section 15.
- 13.
I DISPOSAL CONSIDERATIONS I
If this product becomes a waste, it is not a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart D.
As a non-hazardous waste, it is not subject to federal regulation. Consult state or local regulation for any additional handling, treatment or disposal requirements. For disposal, contact a properly licensed waste treatment, storage, disposal or recycling facility.
114.
l TRANSPORT INFORMATION I
The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are:
LAND TRANSPORT:
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION AIR TRANSPORT (ICAOIIATA):
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 5/8
O MATERIAL SAFETY DATA S o
O N DEO PRODUCT a
Nalco NALCO 9353 EMERGENCY TELEPHONE NUMBER iHEET (800) 424-9300 (24 Hours)
CHEMTREC MARINE TRANSPORT (IMDGIIMO):
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION i 15.
i REGULATORY INFORMATION I
NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, none of the substances in this product are hazardous.
CERCLAISUPERFUND, 40 CFR 117, 302:
Notification of spills of this product is not required.
SARAJSUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE 1II) - SECTIONS 302, 311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
)ur hazard evaluation has found that this product is not hazardous under 29 CFR 1910.1200.
I/
Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
The chemical substances in this product are on the TSCA 8(b) Inventory (40 CFR 710).
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 I formerly Sec. 307,40 CFR I formerly Sec. 311:
None of the substances are specifically listed in the regulation.
CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
None of the substances are specifically listed in the regulation.
CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
MICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 6/8
o MATERIAL SAFETY DATA SHEET o<ON D EO PRODUCT 0
ONE* Nalco NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC STATE RIGHT TO KNOW LAWS:
None of the substances are specifically listed in the regulation.
NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
Not considered a WHMIS controlled product.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
All substances-in this product are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
- 16.
1 OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:
- The human risk is: Low
- The environmental risk is: Low Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process.
This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, Co.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 7/8
o MATERIAL SAFETY DATA SHEET o
O N D EO PRODUCT I
Nalco NALCO 9353 EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Ariel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO K.Prepared By: Product Safety Department Date issued: 0812312001 ONDEO Nalco Company ONDEO Nalco Center-Naperville, Illinois 60563-1198 (630)305-1000 8/8
0 o<
ONDEO a
- Nalco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROMM 7334 EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hour)
CHEMTREC l1.
1CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:
ACTI-BROM 7334 APPLICATION:
BIOCIDE COMPANY IDENTIFICATION:
Ondeo Nalco Company Ondeo Nalco Center Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER(S):
(800) 424-9300 (24 Hours)
CHEMTREC NFPA 704M/HMIS RATING HEALTH:
i/I FLAMMABILITY:
0/0 INSTABILITY:
0/0 OTHER:
0 = Insignificant I = Slight 2 = Moderate 3 = High 4 = Extreme
- 12.
1 COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)
CAS NO 7647-1 5-6
% (wlw) 30.0- 60.0 Sodium Bromide
- 3.
l HAZARDS IDENTIFICATION
- EMERGENCY OVERVIEW*
CAUTION Causes moderate eye irritation.
Avoid contact with eyes, skin and clothing. Wash with soap and water after handling. Remove contaminated clothing and wash before reuse.
May evolve hydrogen bromide and bromine under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin HUMAN HEALTH HAZARDS - ACUTE:
EYE CONTACT:
Can cause mild to moderate irritation.
SKIN CONTACT:
May cause irritation with prolonged contact.
INGESTION:
lot a likely route of exposure. No adverse effects expected.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 1/10
0
~ONDEO l
Nalco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROMW 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC INHALATION:
Not a likely route of exposure. Aerosols or product mist may irritate the upper respiratory tract.
SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
- 4.
.FIRST AID MEASURES IF SWALLOWED: Call poison control center or doctor immediately for treatment advice. Have person sip a glass of water if able to swallow. Do not induce vomiting unless told to do so by the poison control center or doctor. Do not give anything by mouth to an unconscious person.
IF IN EYES: Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye. Call a poison control center or doctor for treatment advice.
IF ON SKIN OR CLOTHING: Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20 minutes. Call a poison control center or doctor for treatment advice.
IF INHALED: Remove victim to fresh air. If not breathing, give artificial respiration, preferably, mouth-to-mouth. Get medical attentions
- 5.
FIRE FIGHTING MEASURES FLASH POINT:
None EXTINGUISHING MEDIA:
Not expected to bum. Keep containers cool by spraying with water. Use extinguishing media appropriate for surrounding fire.
FIRE AND EXPLOSION HAZARD:
May evolve hydrogen bromide and bromine under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
- 6.
l ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by ained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce any leaks if it is Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 2/10
MATERIAL SAFETY DATA SHEET oQiO N DaE O PRODUCT Natco ACTI-BROMW 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
This pesticide is toxic to fish and aquatic organisms. Do not discharge effluent containing this product into lakes, streams, ponds, estuaries, oceans or other waters, unless in accordance with the requirements of a National Pollutant Discharge Elimination System (NPDES) permit and the permitting authority has been notified in writing prior to discharge. Do not discharge effluent containing this product to sewer systems without previously notifying the local sewage treatment plant authority. For guidance contact your State Water Board or Regional Office of the EPA.
- 17.
HANDLING AND STORAGE HANDLING:
Avoid eye and skin contact. Do not take internally. Do not get in eyes, on skin, on clothing. Have emergency e,.quipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labelled. Keep the containers closed when not in use. Use with adequate ventilation.
STORAGE CONDITIONS:
Store the containers tightly closed. Store in suitable labelled containers.
- 8.
l EXPOSURE CONTROLSIPERSONAL PROTECTION l
OCCUPATIONAL EXPOSURE LIMITS:
This product does not contain any substance that has an established exposure limit.
ENGINEERING MEASURES:
General ventilation is recommended.
RESPIRATORY PROTECTION:
Respiratory protection is not normally needed.
HAND PROTECTION:
Neoprene gloves, Nitrile gloves, Butyl gloves, PVC gloves SKIN PROTECTION:
Wear standard protective clothing.
EYE PROTECTION:
Wear chemical splash goggles.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 3/10
0 o<,ONDEO
?
Natco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROMW 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC HYGIENE RECOMMENDATIONS:
If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Keep an eye wash fountain available. Keep a safety shower available.
HUMAN EXPOSURE CHARACTERIZATION:
Based on our recommended product application and personal protective equipment, the potential human exposure is: Moderate
- 19.
l PHYSICAL AND CHEMICAL PROPERTIES I
PHYSICAL STATE APPEARANCE ODOR Liquid Colorless None SPECIFIC GRAVITY DENSITY SOLUBILITY IN WATER pH (100%)
FREEZING POINT BOILING POINT
/APOR PRESSURE VOC6CONTENT 1.45 @ 770F/250C 12.1 lb/gal Complete 7.9 7 0 F / -14 OC 218 OF /103.5 0 C 5.6 mmHg @ 68 OF /20 0 C 0.00 %
Note: These physical properties are typical values for this product and are subject to change.
110.
I STABILITY AND REACTIVITY I
STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
Freezing temperatures.
MATERIALS TO AVOID:
Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
None known
- 11.
I TOXICOLOGICAL INFORMATION I
-he following results are for the product Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 4/10
0 o:A ONDEO 0O Natco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROMW 7334 EMERGENCY TELEPHONE NUMBER(S)
(500) 424-9300 (24 Hours) hhEMIKEU ACUTE ORAL TOXICITY:
Species LD50 Rat
> 5,000 mg/kg Rating: Non-Hazardous ACUTE DERMAL TOXICITY:
Species LD50 Rabbit
> 2,000 mg/kg Rating: Non-Hazardous PRIMARY SKIN IRRITATION:
Draize Score 0.4 /8.0 Rating: Essentially non-irritating PRIMARY EYE IRRITATION:
Draize Score 10.8 /110.0 Rating: Moderately irritating Test Descriptor Product Test Descriptor Product Test Descriptor Product Test Descriptor Product SENSITIZATION:
This product is not expected to be a sensitizer.
CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
HUMAN HAZARD CHARACTERIZATION:
Based on our hazard characterization, the potential human hazard is: Low
- 12.
ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
The following results are for the product. The following results are for the hypobromous acid (as Br2) generated from sodium bromide and hypochlorite.
ACUTE FISH RESULTS:
Species Exposure LC50 Test Descriptor Fathead Minnow 96 hrs
> 9,999 mg/I Active Substance ( Sodium Bromide)
Guppy 96 hrs 225 mg/l Active Substance (Sodium Bromide)
Bluegill Sunfish 96 hrs 0.52 mg/I HOBr (Generated from NaBr) ( Sodium Bromide)
Rainbow Trout 96 hrs 0.23 mg/I HOBr (Generated from NaBr)
Sheepshead Minnow 96 hrs 0.19 mg/I HOBr (Generated from NaBr)
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 5/10
0 s
o9 ONDEO s
Natco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROM) 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC Rating: Essentially non-toxic ACUTE INVERTEBRATE RESULTS:
Species Exposure LC50 EC50 Test Descriptor Daphnia magna 48 hrs 7,900 mg/I Active Substance Daphnia magna 48 hrs 0.71 mg/I HOBr (Generated from NaBr) (
Sodium Bromide)
American Oyster 96 hrs 0.54 mg/l HOBr (Generated from NaBr Mysid Shrimp (Mysidopsis 96 hrs 0.17 mg/I HOBr (Generated from NaBr) bahia)
Essentially non-toxic Rating : Essentially non-toxic PERSISTENCY AND DEGRADATION:
Biological Oxygen Demand (BOD):
This material is an oxidizing biocide and is not expected to persist in the environment ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: Low Based on our recommended product application and the product's characteristics, the potential environmental exposure is: Moderate f released into the environment, see CERCLAISUPERFUND in Section 15.
- 13.
DISPOSAL CONSIDERATIONS If this product becomes a waste, it is not a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart D.
Wastes resulting from the use of this product may be disposed of on site or at an approved waste disposal facility.
DO NOT REUSE EMPTY CONTAINER. Triple rinse the container (or equivalent). Then offer for recycling or reconditioning, or puncture and dispose of in a sanitary landfill, or incinerate. Bum only if allowed by state and local authorities. If burned, stay out of smoke.
114.
l TRANSPORT INFORMATION I
The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
LAND TRANSPORT:
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION AIR TRANSPORT (ICAO/IATA):
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 6/10
as
^
^
A
^
w -
^
^
l l -
Q 0
MATERIAL SAFETY DATA bHl o A/ O N Da E O PRODUCT E R Nalco ACTY-BROM N
7334 EMERGENCY TELEPHONE NUMBER(S) it:]
(800) 424-9300 (24 Hours)
CHEMTREC Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION MARINE TRANSPORT (IMDG/IMO):
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION
- 15.
I REGULATORY INFORMATION l
NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
Sodium Bromide: Eye irritant CERCLIASUPERFUND, 40 CFR 117,302:
Notification of spills of this product is not required.
SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE l1l) - SECTIONS 302,311,
`12, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
X Immediate (Acute) Health Hazard Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
This product is exempted under TSCA and regulated under FIFRA. The inerts are on the Inventory List.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 7 /10
o OMATERIAL SAFETY DATA SHEET o <>
N DE OPRODUCT
- Nalco ACTI-BROM 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC FOOD AND DRUG ADMINISTRATION (FDA) Federal Food, Drug and Cosmetic Act:
When use situations necessitate compliance with FDA regulations, this product is acceptable under: the following use conditions.
This product may be used to treat pulp and papermill water systems in situations requiring FDA sanction provided the bromide concentration in the water is kept below 22 ppm. The product must be used in conjunction with an oxidant such as bleach or gaseous chlorine. Follow instructions for use in pulp and papermill on the product label.
FEDERAL INSECTICIDE, FUNGICIDE AND RODENTICIDE ACT (FIFRA):
EPA Reg. No. 5185-467-1706 In all cases follow instructions on the product label.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307,40 CFR 116.4 / formerly Sec. 311:
None of the substances are specifically listed in the regulation.
CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
None of the substances are specifically listed in the regulation.
CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
sI-IVICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
STATE RIGHT TO KNOW LAWS:
This product is a registered biocide and is exempt from State Right to Know Labelling Laws.
NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
Pesticide controlled products are not regulated under WHMIS.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
INTERNATIONAL CHEMICAL CONTROL LAWS AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme
'NICNAS) and are listed on the Australian Inventory of Chemical Substances (AICS).
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 8/10
0o 0
MATERIAL SAFETY DATA SHEET se ONDEO
[PRODUCT f
Nalco ACTI-BROM& 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hour)
CHEMTREC EUROPE The substances in this preparation have been reviewed for compliance with the EINECS or ELINCS inventories.
JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Ministry of International Trade & industry List (MITI).
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
THE PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippine Inventory of Chemicals & Chemical Substances (PICCS).
- 16.
OTHER INFORMATION Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product. Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:
The human risk is: Low
- The environmental risk is: Low Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process.
This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 9110
0 ok06 ONDEO a
Natco MATERIAL SAFETY DATA SHEET PRODUCT ACTI-BROMD 7334 EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Ariel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO.
Prepared By: Product Safety Department 1-'Date issued: 11107/2001 Replaces: 01/19/2001 Ondeo Nalco Company Ondeo Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 10/10
0 ok ONDEO v
Na0co MATERIAL SAFETY DATASHEET PRODUCT N
NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hour)
CHEMTREC
- 1.
I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME:
NALCO 1359 PLUS APPLICATION:
CORROSION INHIBITOR COMPANY IDENTIFICATION:
ONDEO Nalco Company ONDEO Nalco Center Naperville, Illinois 60563-1198 EMERGENCY TELEPHONE NUMBER:
(800) 424-9300 (24 Hours)
CHEMTREC NFPA 704M/HMIS RATING HEALTH:
1/2 FLAMMABILITY:
1/1 REACTIVITY:
0/0 OTHER:
0 = Insignificant 1 = Slight 2 = Moderate 3 = High 4 = Extreme
- 12.
l COMPOSITIONIINFORMATION ON INGREDIENTS Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)
Sodium Nitrite Sodium Metaborate CAS NO 7632-00-0 7775-19-1
% (wlw) 10.0 - 30.0 5.0 - 10.0
- 3.
l HAZARDS IDENTIFICATION I
Do not get in eyes, on skin, on clothing. Do not take internally. Keep container tightly closed. In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water. If swallowed, seek medical advice immediately and show this container or label.
Wear suitable protective clothing, gloves and eyelface protection.
Not flammable or combustible. May evolve oxides of nitrogen (NOx) under fire conditions. If product is allowed to dry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials. May evolve oxides of carbon (COx) under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 1 /10
o MAThKIAL bAfthl DYATA ShttI I
of< ONDEO PRODUCT Nalco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC HUMAN HEALTH HAZARDS - ACUTE:
EYE CONTACT:
Can cause mild to moderate irritation.
SKIN CONTACT:
Can cause mild irritation.
INGESTION:-
Not a likely route of exposure. Large exposures may be fatal. Ingestion of sodium nitrite can cause methemoglobinemia which can lead to cyanosis and possible death. Pregnant women and their fetuses are particularly sensitive to the effects of methemoglobinemia.
INHALATION:
Not a likely route of exposure. Aerosols or product mist may irritate the upper respiratory tract SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
"-Sodium Nitrite. Pregnant women are particularly sensitive to methemoglobinemia.
HUMAN HEALTH HAZARDS - CHRONIC:
Repeated ingestion of small amounts of sodium nitrite causes drops in blood pressure, rapid pulse, headaches and visual disturbances. It may also react with organic amines in the body to form carcinogenic nitrosamines.
- 4.
l FIRST AID MEASURES EYE CONTACT:
Immediately flush eye with water for at least 15 minutes while holding eyelids open. If irritation persists, repeat flushing. Get immediate medical attention.
SKIN CONTACT:
Immediately flush with plenty of water for at least 15 minutes. If symptoms persist, call a physician.
INGESTION:
Induce vomiting if the patent is fully conscious. If conscious, washout mouth and give water to drink. Get immediate medical attention.
INHALATION:
Remove to fresh air, treat symptomatically. Get medical attention.
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. Measures against circulatory shock, respiratory depression and convulsions may be needed.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 2/10
o 0
MATERIAL SAFETY DATA S ON DEO PRODUCT Nalco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER HEET (800) 424-9300 (24 Hous)
CHEMTREC I 5.
FIRE FIGHTING MEASURES FLASH POINT:
None EXTINGUISHING MEDIA:
Not expected to bum. Use extinguishing media appropriate for surrounding fire.
FIRE AND EXPLOSION HAZARD:
Not flammable or combustible. May evolve oxides of nitrogen (NOx) under fire conditions. If product is allowed to dry, the sodium nitrite is an oxidizing agent and can initiate the combustion of other materials. May evolve oxides of carbon (COx) under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit
- 6.
l ACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
Restrict access to area as appropriate until clean-up operations are complete. Ensure clean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities.
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in compliance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
Do not contaminate surface water.
- 17.
i HANDLING AND STORAGE l
HANDLING:
Avoid eye and skin contact Do not take internally. Do not get in eyes, on skin, on clothing. Have emergency equipment (for fires, spills, leaks, etc.) readily available. Ensure all containers are labelled. Keep the containers closed when not in use. Use with adequate ventilation.
STORAGE CONDITIONS:
Store the containers tightly closed. Store in suitable labelled containers.
l8.
l EXPOSURE CONTROLS/PERSONAL PROTECTION l
OCCUPATIONAL EXPOSURE LIMITS:
This product does not contain any substance that has an established exposure limit ONDEO Nalco Company ONDEO Nalco Centers Naperville, Illinois 60563-1198 (630)305-1000 3110
O 0
MAItKIAL bAftIY UAIA btt I.
oI OONDEO PRODUCT
- Nalco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC ENGINEERING MEASURES:
General ventilation is recommended.
RESPIRATORY PROTECTION:
Respiratory protection is not normally needed.
HAND PROTECTION:
Neoprene gloves, Nitrile gloves, Butyl gloves, PVC gloves SKIN PROTECTION:
Wear standard protective clothing.
EYE PROTECTION:
Wear chemical splash goggles.
HYGIENE RECOMMENDATIONS:
If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Keep an eye wash fountain available. Keep a safety shower available.
HUMAN EXPOSURE CHARACTERIZATION:
Based on our recommended product application and personal protective equipment, the potential human exposure is: Moderate r9.-
PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Light yellow ODOR SPECIFIC GRAVITY 1.305 @ 72 F /22.2°C DENSITY 10.84 lb/gal SOLUBILITY IN WATER Complete pH (
11.1 -12.2 VISCOSITY Max 7 cps @ 73 OF 122.8 °C FREEZING POINT
< -50 °F / -45.5 OC VAPOR PRESSURE Same as water
- 10.
I STABILITY AND REACTIVITY STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 4/10
Q MATERIAL SAFETY DATA SHEET o<CIONDEO PRODUCT Natco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800)424-9300(24 Hous)
CHEMTREC CONDITIONS TO AVOID:
Freezing temperatures.
MATERIALS TO AVOID:
Contact with reducing agents (e.g. hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and toxic vapors. Do not mix with amines. Sodium nitrite can react with certain amines to produce N-nitrosamines, many of which are cancer-causing agents to laboratory animals.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
Oxides of nitrogen
- 11.
TOXICOLOGICAL INFORMATION, No toxicity studies have been conducted on this product.
SENSITIZATION:
This product is not expected to be a sensitizer.
CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
'-1-UMAN HAZARD CHARACTERIZATION:
Based on our hazard characterization, the potential human hazard is: High
- 12.
l ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
No toxicity studies have been conducted on this product.
ENVIRONMENTAL HAZARD AND EXPOSURE CHARACTERIZATION Based on our hazard characterization, the potential environmental hazard is: Moderate Based on our recommended product application and the product's characteristics, the potential environmental exposure is: High If released into the environment, see CERCLNSUPERFUND in Section 15.
- 13.
l DISPOSAL CONSIDERATIONS l
If this product becomes a waste, it is not a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, nor is it listed under Subpart D.
Hazardous Waste: D002 ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 5/10
0 0
o0 ONDEO a
Natco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC Hazardous wastes must be transported by a licensed hazardous waste transporter and disposed of or treated in a properly licensed hazardous waste treatment, storage, disposal or recycling facility. Consult local, state, and federal regulations for specific requirements.
- 14.
l TRANSPORT INFORMATION 8
l The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name / Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are:
LAND TRANSPORT:
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
Flash Point:
DOT Reportable Quantity (per package):
'AIR TRANSPORT (ICAO/IATA):
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
SODIUM NITRITE UN 3082 9
III None 430 lbs SODIUM NITRITE Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Packing Group:
IATA Cargo Packing Instructions:
IATA Cargo Aircraft Limit:
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
SODIUM NITRITE UN 3082 9
Ill 914 NO LIMIT (Max net quantity per package)
MARINE TRANSPORT (IMDG/IMO):
Proper Shipping Name:
PRODUCT IS NOT REGULATED DURING TRANSPORTATION I
I 15.
I REGULATORY INFORMATION I
NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
Sodium Nitrite: Target Organ Effect - Kidney, Target Organ Effect - Nervous system, Target Organ Effect - Blood ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 6 /10
0 0
MATERLIAL bAft:I TY DATIA SWl1tT I
PRODUCT oCONDEO Nalco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC Sodium Metaborate: Irritant CERCLAJSUPERFUND, 40 CFR 117, 302:
This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product.
RQ Substance RQ Sodium Nitrite 430 lbs SARA/SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE 1II) - SECTIONS 302,311, 312, AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following EPA hazard categories:
X Immediate (Acute) Health Hazard X
Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
The chemical substances in this product are on the TSCA 8(b) Inventory (40 CFR 710) or are sold commercially under the polymer exemption (40 CFR 723.250).
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307, 40 CFR I formerly Sec. 311:
This product contains the following substances listed in the regulation:
Substance(s)
Citations Sodium Nitrite:
Sec. 311 CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
None of the substances are specifically listed in the regulation.
CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 7/10
o 0
MATIKIAL SAFL ITY DA IA btlr= I oc7O N D EOPRODUCT
- Nako NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hours)
CHEMTREC MICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
STATE RIGHT TO KNOW LAWS:
The following substances are disclosed for compliance with State Right to Know Laws:
Sodium Nitrite 7632-00-0 NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
D2A - Materials Causing Other Toxic Effects -Very Toxic Material, D2B - Materials Causing Other Toxic Effects -
Toxic Material CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
All substances in this product are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
'..-INTERNATIONAL CHEMICAL CONTROL LAWS AUSTRALIA All substances in this product comply with the National Industrial Chemicals Notification & Assessment Scheme (NICNAS) and are listed on the Australian Inventory of Chemical Substances (AICS).
EUROPE All substances in this product comply with the notification requirements of the European Commission Directive 671548/EEC and amendments and are listed on the European Inventory of Existing Commercial Substances (EINECS).
JAPAN All substances in this product comply with the Law Regulating the Manufacture and Importation Of Chemical Substances and are listed on the Ministry of International Trade & industry List (MITI).
KOREA All substances in this product comply with the Toxic Chemical Control Law (TCCL) and are listed on the Existing Chemicals List (ECL)
THE PHILIPPINES All substances in this product comply with the Republic Act 6969 (RA 6969) and are listed on the Philippine Inventory of Chemicals & Chemical Substances (PICCS).
116.
l OTHER INFORMATION a
ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 8/10
o MATIERIAL SAtEI Y DAIA SHEEtI o<1ONDEO PRODUCT Nalco NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800) 424-9300 (24 Hour)
CHEMTREC Due to our commitment to Product Stewardship, we have evaluated the human and environmental hazards and exposures of this product Based on our recommended use of this product, we have characterized the product's general risk. This information should provide assistance for your own risk management practices. We have evaluated our product's risk as follows:
' The human risk is: Moderate
- The environmental risk is: Moderate Any use inconsistent with our recommendations may affect the risk characterization. Our sales representative will assist you to determine if your product application is consistent with our recommendations. Together we can implement an appropriate risk management process.
This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American oonference of Govemmental Industrial Hygienists, OH., (Ariel Insight# CD-ROM Version), Ariel Research Corp.,
.Bethesda, MD.
Hazardous Substances Data Bank, National Library of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, Co.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Adel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Ariel Insight# CD-ROM Version), AMel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
- icromedex, Inc., Englewood, CO ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 9/10
0 0 0 I"4 C.I a
ONDEO Nalco MATERIAL SAFETY DATA SHEET PRODUCT NALCO 1359 PLUS EMERGENCY TELEPHONE NUMBER (800)424-9300(24 Hours)
CHEMTREC Prepared By: Product Safety Department Date issued: 10/25/2001 Replaces: 09/25/1995 ONDEO Nalco Company ONDEO Nalco Center
- Naperville, Illinois 60563-1198 (630)305-1000 10/10
- NALCO MATERIAL SAFETY DATA SHEET PRODUCT H-1 30M EMERGENCY TELEPHONE NUMBEK(S)
(800) 424-9300 (24 Hours)
CHEMTREC l1.
I CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
. I PRODUCT NAME:
H-130M APPLICATION:
BIOCIDE COMPANY IDENTIFICATION:
EMERGENCY TELEPHONE NUMBER(S):
Nalco Company 1601 W. Diehl Road Naperville, Illinois 60563-1198 (800) 424-9300 (24 Hours)
CHEMTREC NFPA 704MWHMIS RATING HEALTh:
3/3 FLAMMABILITY:
2/2 INSTABILITY:
0/0 0 = Insignificant I = Slight 2 = Moderate 3 = High.4 = Extreme OTHER:
- 12.
l COMPOSITION/INFORMATION ON INGREDIENTS I
Our hazard evaluation has identified the following chemical substance(s) as hazardous. Consult Section 15 for the nature of the hazard(s).
Hazardous Substance(s)
Didecyl-Dimethyl-Ammonium chloride Ethanol CAS NO 7173-51-5 64-17-5
% (wlw) 50.0 5-10
- 13.
1HAZARDS IDENTIFICATION
- EMERGENCY OVERVIEW**
DANGER CORROSIVE. Causes severe eye and skin damage. Harmful or fatal if swallowed. Do not get in eyes, on skin, or on clothing. Wears goggles or face shield and rubber gloves when handling. Avoid contamination of food. Remove contaminated clothing and wash before reuse.
Do not get In eyes, on skin, on clothing. Do not take internally. Keep away from heat. Keep away from sources of ignition - No smoking. Use with adequate ventilation. Keep container tightly dosed and in a well-ventilated place.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. After contact with skin, wash immediately with plenty of water.
Wear chemical resistant apron, chemical splash goggles, impervious gloves and boots.
Combustible Liquid; may form combustible mixtures at or above the flash point. Empty product containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of Ignition. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve HCI under fire conditions. May evolve ammonia (NH4) under fire conditions.
PRIMARY ROUTES OF EXPOSURE:
Eye, Skin Nalco Company 1601 W. Diehl Road e Naperville, Illinois 60563-1198 (630)305-1000 1/9
MATERIAL SAFETY DATA SHEET PNALCO PRODUCT H-130M EMERGENCY TELEPHONE NUMBEFk(S)
(800) 424-9300 (24 Hours)
CHEMTREC HUMAN HEALTH HAZARDS -ACUTE:
EYE CONTACT:
May cause severe irritation or tissue damage depending on the length of exposure and the type of first aid administered.
SKIN CONTACT:
May cause severe Irritation or tissue damage depending on the length of exposure and the type of first aid administered.
INGESTION:
May cause bums to mouth and gastro-intestinal tract.
INHALATION:
Repeated or prolonged exposure may irritate the respiratory tract. Can cause central nervous system depression.
SYMPTOMS OF EXPOSURE:
Acute:
A review of available data does not identify any symptoms from exposure not previously mentioned.
Chronic:
A review of available data does not identify any symptoms from exposure not previously mentioned.
AGGRAVATION OF EXISTING CONDITIONS:
A review of available data does not identify any worsening of existing conditions.
- 14.
1 FIRST AID MEASURES For Eyes and Skin: Flush with plenty of water for at least 15 minutes. (Eyelids must be held open). Call a physician immediately. Remove contaminated clothing and wash before reuse.
If swallowed: Immediately give 3-4 glasses of milk; if unavailable, give water. Do not induce vomiting. Call a physician.
NOTE TO PHYSICIAN: Probable mucosal damage may contraindicate the use of gastric lavage.
NOTE TO PHYSICIAN:
Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition.
- 15.
l FIRE FIGHTING MEASURES FLASH POINT:
109 *F /43 °C (SETAFLASH)
EXTINGUISHING MEDIA:
Foam, Carbon dioxide, Dry powder, Other extinguishing agent suitable for Class B fires, For large fires, use water spray or fog, thoroughly drenching the burning material.
Water mist may be used to cool closed containers.
Nalco Company 1601 W. Diehl Road e Naperville, Illinois 60563-1198 (630)305-1000 2/9
P4NALCO MATERIAL SAFETY DATA SHEET PRODUCT H-130M EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hours)
CHEMTREC FIRE AND EXPLOSION HAZARD:
Combustible Liquid; may form combustible mixtures at or above the flash point. Empty product containers may contain product residue. Do not pressurize, cut, heat, weld, or expose containers to flame or other sources of ignition. May evolve oxides of carbon (COx) under fire conditions. May evolve oxides of nitrogen (NOx) under fire conditions. May evolve HCI under fire conditions. May evolve ammonia (NH4) under fire conditions.
SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING:
In case of fire, wear a full face positive-pressure self contained breathing apparatus and protective suit.
- 6.
lACCIDENTAL RELEASE MEASURES PERSONAL PRECAUTIONS:
'Notify appropriate government, occupational health and safety and environmental authorities. Restrict access to area as appropriate until clean-up operations are complete. Ensure dean-up is conducted by trained personnel only. Ventilate spill area if possible. Do not touch spilled material. Eliminate ignition sources. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection).
METHODS FOR CLEANING UP:
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. LARGE SPILLS: Contain liquid using absorbent material, by digging trenches or by diking. Reclaim into recovery or salvage drums or tank truck for proper disposal. Wash site of spillage thoroughly with water. Contact an approved waste hauler for disposal of contaminated recovered material. Dispose of material in complance with regulations indicated in Section 13 (Disposal Considerations).
ENVIRONMENTAL PRECAUTIONS:
This product is toxic to fish and other water organisms. Do not discharge directly into lakes, ponds, streams, waterways or public water supplies.
- 7.
HANDLING AND STORAGE HANDLING:
Do not get in eyes, on skin, on clothing. Do not take internally. Use with adequate ventilation. Avoid release of vapors or mists into workplace air. Keep the containers closed when not in use. Do not use in locations where vapor is likely to travel to welding flames or arcs or to other hot surfaces. Vapors are much heavier than air, this can result in uneven distribution. Have emergency equipment (for fires, spills, leaks, etc.) readily available.
STORAGE CONDITIONS:
Store away from heat and sources of ignition. Connections must be grounded to avoid electrical charges. Store the containers tightly dosed. Store separately from oxidizers. Store in suitable labelled containers.
8.-
EXPOSURE CONTROLSIPERSONAL PROTECTION OCCUPATIONAL EXPOSURE LIMITS:
Exposure guidelines have not been established for this product. Available exposure limits for the substance(s) are shown below.
ACGIHITLV:
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 (630)305-1000 3/9
P4NALCO MATERIAL SAFETY DATA SHEET PRODUCT H-1 30M EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hours)
CHEMTREC Substance(s)
Ethanol OSHA/PEL:
Substance(s)
Ethanol TWA: 1,000 ppm, 1,880 mglm3 TWA: 1,000 ppm, 1,900 mg/m3 ENGINEERING MEASURES:
Use general ventilation with local exhaust ventilation.
RESPIRATORY PROTECTION:
If significant mists, vapors or aerosols are generated an approved respirator is recommended. An organic vapor cartridge with dust/mist prefilter may be used. In event of emergency or planned entry Into unknown concentrations a positive pressure, full-facepiece SCBA should be used. If respiratory protection is required, institute a complete respiratory protection program including selection, fit testing, training, maintenance and inspection.
HAND PROTECTION:
Neoprene gloves, Viton# gloves SKIN PROTECTION:
Wear impervious apron and boots. A full slicker suit is recommended if gross exposure is possible.
EYE PROTECTION:
Wear chemical splash goggles.
HYGIENE RECOMMENDATIONS:
Eye wash station and safety shower are necessary. If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Use good work and personal hygiene practices to avoid exposure.
- 9.
l PHYSICAL AND CHEMICAL PROPERTIES PHYSICAL STATE Liquid APPEARANCE Light yellow ODOR Alcoholic SPECIFIC GRAVITY 0.93 @ 77 F /25 eC DENSITY 7.7 lb/gal SOLUBILITY IN WATER Complete pH (1 %)
7.0 -8.0 VISCOSITY
< 100 cps @ 77 F125tC FREEZING POINT 12 F /
VOC CONTENT 10 %
Note: These physical properties are typical values for this product and are subject to change.
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 (630)305-1000 4,9
0tNALCO MATERIAL SAFETY DATA SHEET PRODUCT H-130M EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC 1 10.
I STABILITY AND REACTIVITY I
STABILITY:
Stable under normal conditions.
HAZARDOUS POLYMERIZATION:
Hazardous polymerization will not occur.
CONDITIONS TO AVOID:
Heat and sources of ignition including static discharges.
MATERIALS TO AVOID:
Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid. perchlorate, concentrated oxygen, permanganate) may generate heat, fires, explosions and/or toxic vapors. Contact with reducing agents (e.g.
hydrazine, sulfites, sulfide, aluminum or magnesium dust) may generate heat, fires, explosions and toxic vapors.
HAZARDOUS DECOMPOSITION PRODUCTS:
Under fire conditions:
Oxides of carbon, Oxides of nitrogen, HCI I'11.
lTOXICOLOGICAL INFORMATION I
I The following results are for the product ACUTE DERMAL TOXICITY:
Species LD50 Rabbit
> 4 glkg Rating: Non-Hazardous Test Descriptor Product SENSITIZATION:
This product Is not expected to be a sensitizer.
CARCINOGENICITY:
None of the substances in this product are listed as carcinogens by the Intemational Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH).
l12.
1 ECOLOGICAL INFORMATION ECOTOXICOLOGICAL EFFECTS:
The following results are for the product.
ACUTE FISH RESULTS:
Species Exposure LC50 Test Descriptor Rainbow Trout 96 hrs 2.2 mg/i Bluegil Sunfish 96 hrs 0.92 fl Rating: Very toxic Nalco Company 1601 W. Diehl Road e Naperville, Illinois 60563-1198 (630)305-1000 519
AWNALCO MATERIAL SAFETY DATA SHEET PRODUCT H-130M EMERGENCY TELEPHONE NUMBER(S)
(800)424-9300(24 Hours)
CHEMTREC ACUTE INVERTEBRATE RESULTS:
Spedes Exposure LC50 EC50 Test Descriptor Daphnia magna 48 hrs 0.19 mg/i I Mysid Shrimp (Mysidopsis 96 hrs 0.14 mg/l bahia)
Rating: Very toxic If released Into the environment, see CERCLNSUPERFUND in Section 15.
113.
I DISPOSAL CONSIDERATIONS If this product becomes a waste, It could meet the criteria of a hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA) 40 CFR 261. Before disposal, It should be determined if the waste meets the criteria of a hazardous waste.
Hazardous Waste: D001 Pesticide wastes are acutely hazardous. Improper disposal of excess pesticide, spray mixture, or rinsate is a violation of Federal law. If these wastes cannot be disposed of by use according to label instructions, contact your State Pesticide or Environmental Control Agency, or the Hazardous Waste Representative at the nearest EPA Regional Office for guidance.
I 14.
I TRANSPORT INFORMATION I
The information in this section is for reference only and should not take the place of a shipping paper (bill of lading) specific to an order. Please note that the proper Shipping Name I Hazard Class may vary by packaging, properties, and mode of transportation. Typical Proper Shipping Names for this product are as follows.
LAND TRANSPORT:
Proper Shipping Name:
Technical Name(s):
UN/ID No:
Hazard Class - Primary:
Hazard Class - Secondary:
Packing Group:
CORROSIVE LIQUID, FLAMMABLE, N.O.S.
DIDECYLDIMETHYLAMMONIUM CHLORIDE, ETHANOL UN 2920 8
3 Il Flash Point:
43 eC / 109 °F AIR TRANSPORT (ICAO/IATA):
Proper Shipping Name:
Technical Name(s):
UNAID No:
Hazard Class - Primary:
Hazard Class - Secondary:
Packing Group:
IATA Cargo Packing Instructions:
CORROSIVE LIQUID, FLAMMABLE, N.O.S.
DIDECYLDIMETHYLAMMONIUM CHLORIDE, ETHANOL UN 2920 8
3 Il Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 (630)305-1000 6/9
j1NALCO MATERIAL SAFETY DATA SHEET PRODUCT H-130M EMERGENCY TELEPH-ONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC IATA Cargo Aircraft Umit:
(Max net quantity per package)
MARINE TRANSPORT (IMDGA1MO):
Proper Shipping Name:
CORROSIVE LIQUID, FLAMMABLE, N.O.S.
Technical Name(s):
DIDECYLDIMETHYLAMMONIUM CHLORIDE, ETHANOL UNAID No:
UN 2920 Hazard Class - Primary:
8 Hazard Class - Secondary:
3 Packing Group:
II
- 15.
REGULATORY INFORMATION NATIONAL REGULATIONS, USA:
OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
Didecyl-Dimethyl-Ammonium chloride: Corrosive Ethanol: Flammable CERCLA/SUPERFUND, 40 CFR 117,302:
This product contains the following Reportable Quantity (RQ) Substance. Also listed is the RQ for the product If a reportable quantity of product is released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D.C. (1-800-424-8802).
RO Substance Ethanol RQ 1,000 lbs SARAISUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 (TITLE 1II) - SECTIONS 302,311, 312. AND 313:
SECTION 302 - EXTREMELY HAZARDOUS SUBSTANCES (40 CFR 355):
This product does not contain substances listed in Appendix A and B as an Extremely Hazardous Substance.
SECTIONS 311 AND 312 - MATERIAL SAFETY DATA SHEET REQUIREMENTS (40 CFR 370):
Our hazard evaluation has found this product to be hazardous. The product should be reported under the following indicated EPA hazard categories:
X X
Immediate (Acute) Health Hazard Delayed (Chronic) Health Hazard Fire Hazard Sudden Release of Pressure Hazard Reactive Hazard Under SARA 311 and 312, the EPA has established threshold quantities for the reporting of hazardous chemicals.
The current thresholds are: 500 pounds or the threshold planning quantity (TPQ), whichever is lower, for extremely hazardous substances and 10,000 pounds for all other hazardous chemicals.
Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 (630)305-1000 7,9
MATERIAL SAFETY DATA SHEET PNALCO PRODUCT H-1 30M EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC SECTION 313 - LIST OF TOXIC CHEMICALS (40 CFR 372):
This product does not contain substances on the List of Toxic Chemicals.
TOXIC SUBSTANCES CONTROL ACT (TSCA):
The substances In this preparation are included on or exempted from the TSCA 8(b) Inventory (40 CFR 710)
FEDERAL INSECTICIDE, FUNGICIDE AND RODENTICIDE ACT (FIFRA):
EPA Reg. No. 6836-203-1706 In all cases follow instructions on the product label.
FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 / formerly Sec. 307.40
.CFR 116.4 / formerly Sec. 311:
None of the substances are specifically listed in the regulation.
CLEAN AIR ACT, Sec. 111 (40 CFR 60, Volatile Organic Compounds), Sec. 112 (40 CFR 61, Hazardous Air Pollutants), Sec. 602 (40 CFR 82, Class I and 11 Ozone Depleting Substances):
This product contains the following substances listed in the regulation:
Substance(s)
Citations Ethanol Sec. 111 CALIFORNIA PROPOSITION 65:
This product does not contain substances which require warning under California Proposition 65.
MICHIGAN CRITICAL MATERIALS:
None of the substances are specifically listed in the regulation.
STATE RIGHT TO KNOW LAWS:
This product is a registered biocide and is exempt from State Right to Know Labelling Laws.
NATIONAL REGULATIONS, CANADA:
WORKPLACE HAZARDOUS MATERIALS INFORMATION SYSTEM (WHMIS):
This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the MSDS contains all the information required by the CPR.
WHMIS CLASSIFICATION:
Pesticide controlled products are not regulated under WHMIS.
CANADIAN ENVIRONMENTAL PROTECTION ACT (CEPA):
The substances In this preparation are listed on the Domestic Substances List (DSL), are exempt, or have been reported in accordance with the New Substances Notification Regulations.
- 16.
l OTHER INFORMATION Nalco Company 1601 W. Diehl Road
- Naperville, Illinois 60563-1198 (630)305-1000 8/9
MATERIAL SAFETY DATA SHEET WNALCO PRODUCT H-130M EMERGENCY TELEPHONE NUMBER(S)
(800) 424-9300 (24 Hours)
CHEMTREC This product material safety data sheet provides health and safety Information. The product is to be used in applications consistent with our product literature. Individuals handling this product should be informed of the recommended safety precautions and should have access to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to insure safe workplace operations. Please consult your local sales representative for any further information.
REFERENCES Threshold Umit Values for Chemical Substances and Physical Agents and Biological Exposure Indices, American Conference of Governmental Industrial Hygienists, OH., (AMel Insight# CD-ROM Version), Ariel Research Corp.,
Bethesda, MD.
Hazardous Substances Data Bank, National Ubrary of Medicine, Bethesda, Maryland (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
IARC Monographs on the Evaluation of the Carcinogenic Risk of Chemicals to Man, Geneva: World Health Organization, International Agency for Research on Cancer.
Integrated Risk Information System, U.S. Environmental Protection Agency, Washington, D.C. (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Annual Report on Carcinogens, National Toxicology Program, U.S. Department of Health and Human Services, Public Health Service.
Title 29 Code of Federal Regulations, Part 1910, Subpart Z, Toxic and Hazardous Substances, Occupational Safety and Health Administration (OSHA), (Ariel Insight# CD-ROM Version), Ariel Research Corp., Bethesda, MD.
Registry of Toxic Effects of Chemical Substances, National Institute for Occupational Safety and Health, Cincinnati, OH, (TOMES CPS# CD-ROM Version), Micromedex, Inc., Englewood, CO.
Adel Insight# (An integrated guide to industrial chemicals covered under major regulatory and advisory programs),
North American Module, Western European Module, Chemical Inventories Module and the Generics Module (Adel Insight# CD-ROM Version), Adel Research Corp., Bethesda, MD.
The Teratogen Information System, University of Washington, Seattle, WA (TOMES CPS# CD-ROM Version),
Micromedex, Inc., Englewood, CO.
Prepared By: Product Safety Department Date Issued: 03104/2004 Version Number: 1.5 Nalco Company 1601 W. Diehl Road e Naperville, Illinois 60563-1198 (630)305-1000 9X9
Material Safety Data Sheet AQUACHLORTU Sodium Hypochlorite Solution Revised: 0311712003 ALTIVWA Corporation 1100 Louisiana, Sufte 3160 Houston, Texas 77002-5217
- a-LIV Emerency(Chemtrec): (800) 424-9300 Product Information:
(713) 658-9000 HAZARDOUS INGREDIENTSIIDENTIFY INFORMATION Hazardous Comoonents OSHA PEL ACGIH TLY CAS#
Other limits Sodium Hypochlorite N/E N/E 7681-52-9 None listed Sodium Hydroxide 2 mgrm3 2 mgfM 3 1310-73-2 None listed PHYSICAL I CHEMICAL CHARACTERISTICS Specific Gravity @ 80uF 1.13-1.27 Evaporation rate:
N/A Boiling Point Decomposes above Vapor Pressure (ml-mHg):
17.5 @ 200C 40"C (104 FJ Melting Point 7.5F (-13.6 C)
Vapor Density (Air =1):
NA Solubility hI Water Complete pH 11.5-13.5 AppearancelColor Clear, pale yellow or slightly green FIRE AND EXPLOSION HAZARDS Flash Point Non-Flammable LEL:
N/A Flammable imnits:
NWA UEL:
NIA Special Fire Fighting Use extinguishing media that Is appropriate for the surrounding fire. Use water spray to Procedure/Precaution:
cool fire exposed containers.
Use NIOSHJMSHA approved self-contained breathing apparatus and full protective clothing if involved in a fire. Protection is needed against corrosive fumes If liquid Is released.
Unusual Fire/Explosion Sodium hypochlorite is an oxidizing agent. Keep away from oxidizable materials In a fire Hazards:
situation. Decomposition can be caused by heat. if possible, remove containers from fire area to prevent over pressurization and rupture.
REACTMTY DATA Reactivity.
Reaction with adds. arnonlacal compounds, oxidizable materials, and metals.
Stability:
Stable under proper storage conditions.
Incompatibility.
Any acid metal, ammonia, urea, oxidizable materials, and metals (nickel, copper, tin, aluminum, and iron).
Hazardous Chlorine gas (CI2) rate of decomposition Increases with the concentration and with Decomposition/Byproducts:
temperatures above 85F.
Hazardous Polymerization:
Wifl not occur Condition to Avoid:
Keep away from high heat, and sunlight or ultraviolet light. Do not store above 85F.
HEALTH HAZARDS & MEDICAL PROCEDURES The common recognized injury from sodium hypochlorite Is tissue irritation.
ROUTES OF ENTRY Inhalation:
Irritation of the respiratory system. Mist or fumes may cause bronchial Irritation, coughing, difficutt breathing, nausea and pulmonary edema.
Ingestion:
Oral or gastrointestinal irritation.
Corrosion of mucous membranes, perforation of esophagus and stomach may follow.
Skin-Eye
Contact:
Lquid or mist contact can produce severe eye Irritation.
Uquid contact can cause blistering and eczema.
Inhalation:
Ingestion:
Skin-Eye Contact Carcinogenicy Toxicity:
MEDICAL PROCEDURES Remove victim from contaminated atmosphere. If breathing has stopped, give artificial respiration.
Weak breathing may be supplemented with a bag-mask respirator or a manually operated air supply that delivers at least 1 Liter/sec.
CALL PHYSICIAN IMMEDIATELY.
Rinse mouth with water.
Immediately dilute swallowed material by orally administering large amounts of water or milk. DO NOT INDUCE VOMmNG. Do not use acidic antidotes or sodium bicarbonate.
CALL PHYSICIAN IMMEDIATELY. For eyes, immediately flush victims eyes with running water for at least 15 minutes. For skin, Immediately remove contaminated clothing under a safety shower. Flush skin with running water for at least 15 minutes. Contact a physician for bumns. Launder clothing before reuse.
Sodium Hypochlorlte Is not listed as a carcinogen by NTP. IARC, ACGIH, or OSHA The acute oral LD50 (rat) is 12 g/kg.
CONTROL MEASURES PERSONAL SAFEIY EQUIPMENT Respiratory:
Cartridges must be NIOSHIMSHA approved against chlorine. In case of fire, use SCBA for rescue.
Hands-Body.
Rubber gloves (PVC), aprons, or slicker sult.
Face-Eyes:
Clear goggles Storage:
Spill or Leakl Disposal:
HANDLING AND STORAGE Stainless steel or fiberglass tanks are recommended.
Keep product away from heat sources and direct sunlight.
Do not reuse storage containers unless properly reconditioned.
Prevent liquid from entering sewers or waterways. Sodium hypochlorite can be neutralized with weak reducing agents. Adequate ventilation Is required when containing spills~leaks.
Contact state or federal agencies for disposal procedures hat are in accordance with environmental regulations for a large or uncontalned spill. Wear appropriate prtective gear.
OTHER INFORMATION TRANSPORTATION INFORMATION DOT Shipping Name: Hypochlorite Solution, Corrosive Class: 8 UN#: 1791 Packing Group: PG III RQ: 100 Ibs. (Sodium Hypochlorite)
REGULATORY INFORMATION TSCA (TOXIC SUBSTANCE CONTROL ACT):
Al components of this mixture are listed on the TSCA Chemical Inventory.
SARA TITLE Ill, SECTION 302:
Not listed as an Extremely Hazardous Substance.
CERCLA (COMPREHENSIVE RESPONSE COMPENSATION, AND LIABILITY ACT):
Subject to reporting requirements under CERCLA (40 CFR 302).
CERCLA REPORTABLE QUANTITY:
Releases of Sodium Hypochlorite in quantities equal to or greater than the reportable quantity (RQ) of 100 pounds are subject to reporting to the National Response Center under CERCLA, Section 304 SARA Title IlIl.
SARA TITLE Ill - HAZARD CLASSES:
Acute Health Hazard: Yes Chronic Health Hazard: No Fire Hazard: No Sudden Release of Pressure Hazard: No Reactivity Hazard: No
SARA TITLE liI - SECTION 313 SUPPUER NOTIFICATION:
This product contains the following toxic chenicals subject to the reporting requirements of Section 313 of the Emergency Planning and Community Right-To Know Act (EPCRA) of 1986 and of 40 CFR 372:
INGREDIENT NAME PERCENT BY VOLUME No No No This Infomation must be Included on all MSDS's that are copied and distributed for this material.
OTHER INFORMATION HAZARD CODES NFPA HMIS Rating System Health:
2 Health:
2 0= No Hazard Fiammabillty 0
Flammability:
0 1= Slight Hazard Reactivity:
2 Reactivity:
2 2= Moderate Hazard OXIDIZER 3= Serious Hazard 4= Severe Hazard Disclaimer of Warranty:
The kdomntion provided in this Material Safety Data Sheet has been obtained fron sources belleved ID be relable. ALTIViA provides no warrantes, efter expressed or Implied and assumes no responsily for Ie accuracy or completeness of the data contained herein. This kfonmaton Is offered for your Information, consideration, and kwesUgation. You should satisfy yourself at you have al current data relevant to your parlicular use. ALTIVA knows of no medical condtion. other than those noted on this rnaterial safety data sheet, which are generally ecogned as being aggravated by eposure to this product
Material Safety Data Sheet May be used to comply with OSHA'S Hazard Communication Standard 29 sCFR 1910, 1200. Standard Must be consulted for soecific requirements.
U.S. Department of Labor Occupational Safety and Health Administration (Non-Mandatory Form)*
Form Approved OMB No. 1218-0072 IDENTTY (s use on aw VWust)Note:
Blank sparces are not permitted. If any iRem Is not applicabb., or no Information Is SC-2312 Scale & Corrosion Inhibitor available. the space must be marked tb indicate that Section I Manufactre's Name VariChem International, Inc.
Emergency Telephone Number 1-800-424-9300 Address (Number, Street City. State. and Zip Code)
Telephone Number for nformation 1-979-245-7278 P.O. Box 528 / Hwy 35 West Date Prepared February 02, 2004 Van Vleck, TX 77482 Signature of Preparer (optional)
Section II - Hazardous Ingredients I Identity Information Hazardous Components (Specific Chetrical Identty Comion Name(s))
OSHA PEL ACGIH TLV Other Urnits
% (Optional)
Recomnended None This product contains no hazardous components under current OSHA definitions.
DOT: Not Regulated product does not contain anV SARA Section 313 listed Chemicals **
Section III - Physical / Chemical Characteristics Boiling Point 212 0F Specific Gravity (H20 =1) 1.032 Vapor Pressure (mm Hg.)
16.6 Meing Point N/A Vapor Density (Al=1) 0.6 Evaporation Rate (Butyl Acetate =1)
N/A Soklbbity In Water Complete Appearance and Odor Dark brown liquid with no distinct odor.
Section IV - Fire and Explosion Hazard Data Flash Point (Method Used)
Above 200'F (PMCC)
Flammable Limits LEL NIDA UEL NIDA Extinguishing Media Water spray Special Fire Fighting Procedures Do not enter any enclosed fire space without proper protective equipment.
Unusual Fro and Explosion Hazards None (Reproduce Locaty)
OSHA 174. Sept. 1985 (Reproduce Locally)
OSHA 174. Sept 1985
Section V - Reactivity Data Stability Unstable l
Conditions to Avoid able lX I None nompatibility (Materials to Avoid) Strong acids, strong oxidizing agents.
Hazardous Decomposition orByproducts Incomplete combustion may result in oxides of Phosphorus, Sulfur, & Nitrogen.
Hazardous May Occur Conditions to Avoid Polyrnerizatim Not Occur X
None Section VI - Health Hazard Data Route(s) of Entryf Inhalation?
Yes Sun?
Yes Ingestion?
Yes Health Hazards (Act and Chroft)
This material may cause minor irritation upon contact with the eyes.
CarcinogenWit.
NTP? No IARC Monographs No OSHA Regulated? No Signs and Symptoms of Exposure This material may cause minor irritation upon contact with the eyes. This material is not expected to present a skin contact hazard.
Medical Conditions Aggravated by Exposure None Emergency and Frst Aid Procedures Eyes: Flush with water for 15 min. Seek medical attention if irritation persist.
Skin: Wash with soap & water. Ingestion: Seek medical attention.
Section Vil - Precautions for Safe Handling and Use Steps to Be Taken in case Material Is Released or Spilled Eliminate all open flames in the vicinity of the spill or released vapor. Contain by diking with a Non-Combustible absorbent and dispose of in a DOT approved container.
Waste Disposal Method Flush with water. Absorb large spills with an absorbent, and dispose of in a DOT approved container.
Precautions to Be Taken in Handling and Storing Keep out of reach of Children. Avoid splashing in your eyes.
Other Precautions None Section Vil - Control Measures RespiratoryProtection (Specify'Type) Not normally required.
Ventila0ion lLocal Exhaust Sufficient Special None
{Mechanical (General) None Oter None Protective Gloves es Eye protection Goggles, Safety Glasses Other Protective Clothing Equipment Not normally required.
Wodcygienic Practices Eyewash should be available and ready for use.
I VARICHEx Friday, Doeamber 05, 2003 MATERIAL SAFETY DATA SHEET
- 1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION PRODUCT IDENTITY:
Sulfuric acid 93%
COMPANY IDENTITY:
COMPANY ADDRESS:
COMPANY CITY:
COMPANY PHONE:
CHEMTREC PHONE:
1-800424-9300 MSDS DATE:
11113/03 Chemical Name or Synonym:
SULFURIC ACID Molecular Formula:
H2So 4
- 2. COMPOSITION/INFORMA TION ON INGREDIENTS OSHA Component CAS Reg Number Hazard Percentage SULFURIC ACID 7664-93-9 Y
65 -
100 WATER 7732-18-5 N
BALANCE
- 3. HAZARDS IDENTIFICATION A.
EMERGENCY OVERVIEW:
Physical Appearance and Odor:
colorless oily
- liquid, odorless.
Warning Statements:
IEnd,QfYzge. M.~v.
.,..Gnia~..Coz.trn.e.I
.eg.t.ae I
VARICmEm Frrday, December 05, 2003 Sulfuric Acid 93%
- 3. HAZARDS IDENTIFICATION (Continued)
DANGERI CAUSES SEVERE BURNS. REACTS VIOLENTLY WITH WATER. CONTENTS MAY BE UNDER PRESSURE OF EXPLOSIVE, FLAMMABLE HYDROGEN GAS. HIGHLY REACTIVE AND CAPABLE OF IGNITING COMBUSTIBLE MATERIAL ON CONTACT.
B. POTENTIAL HEALTH EFFECTS:
Acute Eye:
Corrosive. Causes burns, tissue destruction, Can cause blindness.
Acute Skin:
Corrosive. Causes redness, inflammation, burns.
Acute Inhalation:
Harmful if inhaled. Causes upper respiratory tract irritation, lung irritation, chest pain, wheezing, shortness of breath, a burning sensation, tickling of the nose and throat, sneezing.
Acute Ingestion:
Harmful if ingested. Can cause irritation, abdominal pain, corrosion, burns to mouth and esophagus, death.
Chronic Effects:
When mists are released from this product they are considered to be probable or suspected human carcinogens (see Section 11 -
Chronic).
- 4. FIRSTAID MEASURES FIRST AID MEASURES FOR ACCIDENTAL:
Eye Exposure:
Hold eyelids open and flush with a steady, gentle stream of water for at least 15 minutes. Seek immediate medical attention.
Skin Exposure:
In case of contact, immediately wash with plenty of water for at least 15 minutes. Seek medical attention if irritation developes or persists.
Remove contaminated clothing and shoes. Clean contaminated clothing and shoes before re-use.
Inhalation:
Remove victim from immediate source of exposure and assure that the victim is breathing. If breathing is difficult, administer oxygen, if
ZARICHEN Friday, Decenber 05, 2003 Sulfuric Acid 93%
- 4. FIRSTAID MEASURES (Continued) available. If victim is not breathing, administer CPR (cardio-pulmonary resuscitation). Seek medical attention.
Ingestion:
DO NOT INDUCE VOMITING.
If the person is conscious and has no trouble breathing a small (no more than one glass) amount of water may be given.
Do not leave victim unattended. To prevent aspiration of the swallowed product, lay victim on side with head lower than waist. If vomiting occurs do not re-administer water. Do not give anything by mouth to an unconscious person. IMMEDIATELY obtain medical attention.
MEDICAL CONDITIONS POSSIBLY AGGRAVATED BY EXPOSURE:
Inhalation of product may aggravate existing chronic respiratory problems such as asthma, emphysema or bronchitis. Skin contact may aggravate existing skin disease.
NOTES TO PHYSICIAN:
All treatments should be based on observed signs and symptoms of distress in the patient. Consideration should be given to the possibility that overexposure to materials other than this product may have occurred.
This material is an acid. The primary toxicity of this product is due to its irritant effects on mucous membranes.
INHALATION: If cough or shortness of breath occurs, evaluate the possibility of bronchitis or pneumonitis. Chest x-ray and arterial blood gases can be used to determine the presence of pulmonary edema.
In severe cases, use of humidified oxygen and assisted ventilation including positive end expiratory pressure (PEEP) may be needed.
Parenteral steroids may be useful in limiting the extent of pulmonary damage.
SKIN: Wash exposed area thoroughly with soap and water. Chemical burns from strong acids are generally treated the same as thermal burns.
EYES: Irrigate eyes for 15 minutes with sterile saline. If irritation, pain, swelling, photophobia or lacrimation persist, examination by an ophthalmologist is recommended.
INGESTION: If not already performed by first aid personnel, irrigate mouth with large amounts of water and dilute the acid by having victim drink 4 to 8 ounces of water or milk. DO NOT induce vomiting. Use of gastric lavage is controversial. The advantage of removal of acid must E~AndF P-qa P~~nt~
g%'ft VA-ID-en l-vw R
iI-V..
PVA.W.V&k6p$.;41 UoA X
-en W.
. A
-A;A" 4
g ~
v v
vv
7ARICHEM Friday, Deomaber 05, 2003 Sulfuric Acid 93%
- 4. FIRSTAID MEASURES (Continued) be weighted against the risk of perforation or bleeding. If a large amount of acid (> 1 ml/kg body weight) has been recently ingested, cautious gastric lavage is generally advised if the patient is alert and there is little risk of convulsions. Consultation with a gastroenterologist and/or surgeon is advised. Serious complications such as perforation or stricture of the esophagus may occur requiring care by specialists. Laryngeal edema may develop requiring intubation or tracheostomy.
- 5. FIRE FIGHTING MEASURES FIRE HAZARD DATA:
Flash Point:
Not Applicable Extinguishing Media:
Not combustible. Use extinguishing method suitable for surrounding fire.
Recommended (small fires): dry chemical.
Special Fire Fighting Procedures:
Firefighters should wear NIOSH/MSHA approved positive pressure breathing apparatus with full face-piece and full acid-resistant protective clothing. Fight fire from maximum distance.
Unusual Fire and Explosion Eazards:
Not combustible. Strong oxidizers can react with reducing agents or combustibles producing heat and causing ignition. Reacts violently with water releasing heat and corrosive material.
Hazardous Decomposition Materials (Under Fire conditions):
oxides of sulfur
- 6. ACCIDENTAL RELEASE MEASURES Evacuation Procedures and Safety:
Personnel handling this material should be thoroughly trained to handle enxatX.o
.Pge a
ZARICHED Friday, Decmmbmr 05, 2003 Sulfuric Acid 93%
- 6. ACCIDENTAL RELEASE MEASURES (Continued) spills and releases. Do not direct hose streams into an unignited transportation spill (tank truck or tank car).
Containment of Spill:
Stop leak if it can be done without risk. Dike spill using absorbent or impervious materials such as earth, sand or clay. Dike or retain dilution water or water from firefighting for later disposal.
Cleanup and Disposal of Spill:
Pump any free liquid into an appropriate closed container (see Section 7: Handling and Storage). Exercise caution during neutralization as considerable heat may be generated. Carefully neutralize spill with soda ash. Absorb neutralized spill with an inert absorbent. Scrape up and place in appropriate closed container (see Section 7: Handling and Storage).
Environmental and Regulatory Reporting:
Do not flush to drain. Runoff from fire control or dilution water may cause pollution. Dispose of as a hazardous waste. Spills may be reportable to the National Response Center (800-424-8802) and to state and/or local agencies. Large spills should be handled according to a predetermined plan. For assistance in developing a plan contact the Technical Service Department using the Product Information phone number in Section 1.
- 7. HANDLING AND STORAGE Minimum/Maximum Storage Temperatures:
Not Available Handling:
Do not breathe vapors and mists. Do not get on skin or in eyes. This product reacts violently with bases liberating heat and causing spattering.
When diluting an acid, ALWAYS add the acid slowly to water and stir well to avoid spattering. NEVER ADD WATER TO ACID.
Storage:
Store in tightly closed containers. Store in an area that is dry, well-ventilated, diked with impermeable material, Freezing point varies
- _Mww
VARICHED Friday, December 05, 2003 Sulfuric Acid 93%
- 7. HANDLING AND STORAGE (Continued) with concentration. Maximum recommended storage temperature 120F (49C).
- 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Introductory Remarks:
These recommendations provide general guidance for handling this product. Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. While developing safe handling procedures, do not overlook the need to clean equipment and piping systems for maintenance and repairs. Waste resulting from these procedures should be handled in accordance with Section 13: Disposal Considerations.
Assistance with selection, use and maintenance of worker protection equipment is generally available from equipment manufacturers.
Exposure Guidelines:
Exposure limits represent regulated or recommended worker breathing zone concentrations measured by validated sampling and analytical methods, meeting the regulatory requirements. The following limits apply to this material, where, if indicated, S=skin and C=ceiling limit:
SULFURIC ACID Notes TWA STEL ACGIH 1 mg/cu m 3 mg/cu m OSHA 1 mg/cu m RPI 0.3 mg/cu m Engineering Controls:
Where engineering controls are indicated by use conditions or a potential for excessive exposure exists, the following traditional exposure control techniques may be used to effectively minimize employee exposures: local exhaust ventilation at.the point of generation.
Respiratory Protection:
When respirators are required, select NIOSH/MSHA approved equipment based on actual or potential airborne concentrations and in accordance
VARICHEK FrIday, Decmber 05, 2003 Sulfuric Acid 93%
- 8. EXPOSURE CONTROLS/PERSONAL PROTECTION (Continued) with the appropriate regulatory standards and/or industrial recommendations.
Under normal conditions, in the absence of other airborne contaminants, the following devices should provide protection from this material up to the -conditions specified by the appropriate OSHA, WHMIS or ANSI standard(s): Air-purifying (half-mask/full-face) respirator with cartridges/canister approved for use against acid gases.
Eye/Face Protection:
Eye and face protection requirements will vary dependent upon work environment conditions and material handling practices. Appropriate ANSI 287 approved equipment should be selected for the particular use intended for this material.
Eye contact should be prevented through use of chemical safety glasses with side shields or splash proof goggles. An emergency eye wash must be readily accessible to the work area.
Skin Protection:
Skin contact must be prevented through the use of permeation resistant clothing, gloves and footwear, selected with regard for use conditions and exposure potential. An emergency shower must be readily accessible to the work area. Consideration must be given both to durability as well as permeation resistance.
Work Practice Controls:
Personal hygiene is an important work practice exposure control measure and the following general measures should be taken when working with or handling this material:
(1) Do not store, use, and/or consume foods, beverages, tobacco products, or cosmetics in areas where this material is stored.
(2) Wash hands and face carefully before eating, drinking, using tobacco, applying cosmetics, or using the toilet.
(3) Wash exposed skin promptly to remove accidental splashes or contact with this material.
- 9. PHYSICAL AND CHEMICAL PROPERTIES Physical and Chemical properties here represent typical properties of FE E d £;f
.a ge _A ^._79 9
z AA_
_A
,9nt
¢ 3
_A
.v..s w
A ft
'ARICHE2S Friday, Decwdbor 05, 2003 Sulfuric Acid 93%
- 9. PHYSICAL AND CHEMICAL PROPERTIES (Continued) this product. Contact the business area using the Product Information phone number in Section 1 for its exact specifications.
Physical Appearance:
colorless oily liquid.
Odor:
odorless.
pH:
1 at 1 wt/wtk.
Specific Gravity:
Not Available Water Solubility:
miscible Melting Point Range:
Not Available Boiling Point Range:
Not Available Vapor Pressure:
Not Available Vapor Density:
3.4 Molecular Weight:
98.08
- 10. STABILITY AND REACTIVITY Chemical Stablity:
This material is stable under normal handling and storage conditions described in Section 7.
Conditions To Be Avoided:
P..
I VARICHEM Friday, Docember 05, 2003 Sulfuric Acid 93%
- 10. STABILITYAND REACTIVITY (Continued) none known Materials/Chernlcals To Be Avoided:
water strong reducing agents halogens bases metals nitrogen compounds The Following Hazardous Decomposition Products Might Be Expected:
Decomposition Type: thermal oxides of sulfur Hazardous Polymerization Will Not Occur.
Avoid The Following To Inhibit Hazardous Polymerization:
not applicable
- 11. TOXICOLOGICAL INFORMATION Acute Eye Irritation:
Toxicological Information and Interpretation eye - eye irritation, 250 ug/24 hr, rabbit.
Severely irritating.
Acute Skin Irritation:
No test data found for product. This product was not tested because strong acids are known to be corrosive and to cause severe tissue destruction.
Acute Dermal Toxicity:
No test data found for product. This product was not tested because strong acids are known to be corrosive and to cause severe tissue destruction.
Acute Respiratory Irritation:
Toxicological Information and Interpretation lung -
lung irritation, c 5 mg/cu m, human.
Mildly irritating.
Acute Inhalation Toxicity:
I S
ARICHEM Friday, Decomber 05, 2003 Sulfuric Acid 93%
- 11. TOXICOLOGICAL INFOPMifATJON (Continued)
Toxicological Information and Interpretation LC50 -
lethal concentration 50k of test species, 510 mg/cu m/2 hr, rat.
LC50 -
lethal concentration 50k of test species, 347 ppm/1 hr. rat.
Acute Oral Toxicity:
Toxicological Information and Interpretation LD50 -
lethal dose 50% of test species, 2140 mg/kg, rat.
Chronic Toxicity:
This product contains the substances that are considered to be "probable" or "suspected" human carcinogens as follows:
The International Agency for Research on Cancer (IARC) and the National Toxicology Program (NTP) have classified "occupational exposure to strong inorganic acid mists containing sulfuric acid" as a known human carcinogen (IARC Category 1). This classification applies only to sulfuric acid when generated as a mist. There is still debate in the scientific community whether the studies reviewed by IARC and NTP adequately controlled for confounding occupational exposures and personal habits such as cigarette smoking and alcohol consumption. A few epidemiology studies have suggested a possible association between sulfuric acid exposure and laryngeal or lung cancer; however, in all these studies, workers were exposed to many other chemicals, some of which are recognized carcinogens, such as diethylsulfate and nickel.
Considering the multiple chemical exposures and other limitations of the studies, we disagree with IARC's conclusion that a cause and effect relationship between cancer and "occupational exposure to strong inorganic acid mist containing sulfuric acid" has been demonstrated.
Also more recent epidemiological studies have failed to find any association between "occupational exposure to strong inorganic acid mist containing sulfuric acid" and laryngeal or lung cancer. ACGIH has classified "sulfuric acid as contained in strong inorganic acid mists" as a suspect human carcinogen. This classification does not apply to sulfuric acid per se.
Lifetime animal studies in hamsters, rats and guinea pigs were conducted in the 1970's under sponsorship of the Environmental Protection Agency (EPA) or the National Institutes of Environmental Health Sciences (NIEHS). All three lifetime studies were negative for carcinogenic effects. These studies were not formally published by the government agencies because they were satisfied that sulfuric acid mist was not a carcinogenic problem. Because these studies were not published, IARC or NTP did not consider them in their deliberations.
Regulatory Agency Listing Carcinogen Ingredient Name OSHA zARC VTP ACGIN lDn.o~g..~~w~,oain~d~ns~~g
,wv~.,M.
I
I fARICHEHD Friday, Decamber 05, 2003 Sulfuric Acid 93%
- 11. TOXICOLOGICAL INFORMATION (Continued)
OCCUPATIONAL EXPOSURES TO STRONG-INORGANIC-AC No 1
Yes A2 ID MISTS CONTAINING
- 12. ECOLOGICAL INFORMATION Ecotoxicological Information:
Ecotoxicological Information and Interpretation:
The toxicity of sulfuric acid to fish is dependent on the resulting pH of the water. lethality at a pH of 5.0 or below. required to cause lethality varies depending on the hardness of the water (hard water has some buffering capacity) and the species of fish (some fish are more resistant to the effects of acidity). McKee, JE, and Wolf, HA (Editors),
Water Quality Criteria, 2nd ed., Publication No. 3-A, p. 279, California State Water Resources Control Board, Sacramento, CA (rev. 1963).
Chemical Fate Information:
No data found for product.
- 13. DISPOSAL CONSIDERATIONS Waste Disposal Method:
Chemical additions, processing or otherwise altering this material may make the waste management information presented in this MSDS incomplete, inaccurate or otherwise inappropriate.
Please be advised that state and local requirements for waste disposal may be more restrictive or otherwise different from federal laws and regulations.
Consult state and local regulations regarding the proper disposal of this material.
EPA Hazardous Waste - YES EPA RCRA EAZARDOUS WASTE CODES:
"C" Corrosive; "R" Reactive.
Finrl of Psae 11
^"t~nwe on Nt n
De
I0 rARICHEMl Friday, December 05, 2003 Sulfuric Acid 93%
- 14. TRANSPORTATIONINFORMATION Transportation Status: EWPORTANT! Statements below provide additional data on listed DOT classification.
The listed Transportation Classification does not address regulatory variations due to changes in package size, mode of shipment or other regulatory descriptors.
US Department of Tmasportation Hazard Class..... 8 Shipping Name:
SULFURIC ACID ID Number....... UN1830 Packing Group....
II Labels........... CORROSIVE Emergency Guide......
137
- 15. REGULATORY INFORMATION Inventory Status Inventory Status UNITED STATES (TSCA)
Y CANADA (DSL)
Y EUROPE (EINECS/ELINCS)
Y AUSTRALIA (AICS)
Y JAPAN (MITI)
Y SOUTH KOREA (KECL)
Y Y = All ingredients are on the inventory.
E = All ingredients are on the inventory or exempt from listing.
P - One or more ingredients fall under the polymer exemption or are on the no longer polymer list.
All other ingredients are on the inventory or exempt from listing.
N = Not determined or one or more ingredients are not on the inventory and are not exempt from listing.
FEDERAL REGULATIONS Inventory Issues:
All functional components of this product are listed on the TSCA Inventory.
1rA MdfPocw 12 rebti~nalv en es len
1ARICHEM Friday, Decwmbor 05, 2003 Sulfuric Acid 93%
- 15. REGULATORY INFORMATION (Continued)
SARA Title III Hazard Classes:
Fire Hazard
- NO Reactive Hazard
- YES Release of Pressure NO Acute Health Hazard
- YES Chronic Health Hazard - NO SARA 313 Chemicals SULFURIC ACID (65 - 100a)
SARA Extremely Hazardous Substances (EES)/CERCLA Hazardous Substances Ingredient CERCLA/SARA RQ SARA EBS TPQ SULFURIC ACID 1000 lbs 1000 lbs UNLISTED HAZARDOUS WASTES -
CHARACTERISTIC OF CORR 100 lbs OSIVITY UNLISTED HAZARDOUS WASTES - CHARACTERISTIC OF REAC 100 lbs TIVITY STATE REGULATIONS:
This product contains the following components that are regulated under California Proposition 65:
Ingredient Name Cancer List OCCUPATIONAL EXPOSURES TO STRONG-INORGANIC-AC Y
ID MISTS CONTAINING SULFU Reprod.
List N
No Sign. Risk Lv1 (ug/day)
California RPI ND ND
- 16. OTHER INFORMATION National Fire Protection Association Hazard Ratlngs-NTFA(R):
3 Health Hazard Rating--Serious O Flammability Rating--Minimal 2 Instability Rating--Moderate o
- NO WATER National Paint & Coating Hazardous Materials Identirication System--HMNS(R):
3 Health Hazard Rating--Serious o Flammability Rating--Minimal 2 Reactivity Rating--Moderate Reason for Revisions:
rnfi ndfPnop Pnf~nlnnND P"
ARICHEI Frrday, Dectaer 05, 2003 Sulfuric Acid 93%
- 16. OTHER INFORMATION (Continued)
Change and/or addition made to Section 4, Section 7, Section 9, Section 11, Regulatory Review and Update.
Key Legend Information:
ACGIH - American Conference of Governmental Industrial Hygienists OSHA - Occupational Safety and Health Administration TLV - Threshold Limit.Value PEL - Permissable Exposure Limit TWA - Time Weighted Average STEL - Short Term Exposure Limit NTP - National Toxicology Program IARC - International Agency for Research on Cancer ND - Not determined RPI - Rhodia Established Exposure Limits Disclaimer:
The information herein is given in good faith but no warranty, expressed or implied, is made.
VnA nF Pope 14 Enid nf M.QT'1 Innwirnmnf
APPENDIX WS 1.0-3 Cross Reference Technical Report, Worksheet 1.0, Page 1-2
- 3. Process/Non-Process Wastewater Flows: Provide a breakdown of process wastewater flow(s) and non-process wastewater flow(s) as directed.
For Steam Electric Generating Stations (*Not all waste streams are generated at this facility):
- 1.
Process Wastewater A. Chemical Metal Cleaning Wastewater B. Coal Pile Runoff*
C. Ash Management Area Runoff*
- 2.
Non-Process Wastewater A. Utility Wastewater
- 1) Once Through Cooling Water
- 2) Cooling Tower Blowdown
- 3) Non-Chemical Metal Cleaning Wastewater
- 4) Low Volume Wastewater, including flows from the following sources:
- a. Floor Drainage
- b. Boiler Blowdown
- c. Ion Exchange Water Treatment Systems
- d. Reverse Osmosis Water Treatment Systems*
- e. Recirculating Service Water Systems
- f. Wet Scrubber Air Pollution Control Systems*
- g. Laboratory and Sampling Streams
- h. Cooling Tower Basin Cleaning Wastes B. Domestic Sewage C. Air Conditioning Condensate