PPL Rev. 1 SLC SYSTEM 3.1.7 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.1.7.6 Verify each SLC subsystem manual and power 31 days operated valve in the flow path that is not locked, sealed, or otherwise secured in position is in the correct position, or can be aligned to the correct position.
SR 3.1.7.7 Verify each pump develops a flow rate 241.2 gpm In accordance with the at a discharge pressure Ž1395 psig.
Inservice Testing Program SR 3.1.7.8 Verify flow through one SLC subsystem pump into 24 months on a reactor pressure vessel.
STAGGERED TEST BASIS SR 3.1.7.9 Verify all heat traced piping between storage tank 24 months and pump suction is unblocked.
AND Once within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after solution temperature is restored within the limits of Figure 3.1.7-2 I
SUSQUEHANNA - UNIT 1 TS / 3.1-22 Amendment 4<8 221
PPL Rev. 1 SLC System 3.1.7 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY SR 3.1.7.6 Verify each SLC subsystem manual and power 31 days operated valve in the flow path that is not locked, sealed, or otherwise secured in position is in the correct position, or can be aligned to the correct position.
SR 3.1.7.7 Verify each pump develops a flow rate Ž 41.2 gpm In accordance with the at a discharge pressure> 1395 psig.
Inservice Testing Program SR 3.1.7.8 Verify flow through one SLC subsystem pump into 24 months on a reactor pressure vessel.
STAGGERED TEST BASIS SR 3.1.7.9 Verify all heat traced piping between storage tank 24 months and pump suction is unblocked.
AND Once within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after solution temperature is restored within the limits of Figure 3.1.7-2 SUSQUEHANNA - UNIT 2 TS / 3.1-22 AmendmentA1 198