I *-

'-

XcelEnergysM April 1, 2002 414 Nicollet Malt Minneapolis, Minnesota 55401-1993 Mr. Paul Kim Environmental Pollution Control Agency Integrated Data Management Unit 520 Lafayette Road N.

St. Paul, MN 55155-4194 Re:

Air Pollutant Emissions Inventory Report for 2001 Enclosed are Northern States Po6'er d/b/a Xcel Energy's 2001 Air Pollutant Emissions Inventory Report completed and signed for the following facilities owned and operated by Northern States Power Company d/b/a Xcel Energy:

Facility Name Allen S. King Alliant Techsystems Black Dog Blue Lake General Office Granite City High Bridge Inver Hills Key City Maple Grove Facility I.D. #

16300005 05300697 03700003 13900010 05300855 00900021 12300012 03700015 01300015 05300898 Facility Name Minnesota Valley Monticello Prairie Island Red Wing Riverside Sherbume County United Healthcare Wescott West Faribault Wilmarth Facility l.D. #

02300012 17100019 04900030 04900005 05300015 14100004 05300698 03700064 13100003 01300015 Northern States Power d/b/a Xcel Energy also owns and operates three (3) oil-fired generators located at the United Hospital Facility in St. Paul.

These units are included in the facility Emission Inventory Report which is signed and submitted by United Hospital; The NSP-Compost & Wood Proicessing Facility located in Burnsville, MN is longer owned and operated by Northern States Power d/b/a Xcel Energy and is not included in this submittal.

The Additional Data Summary is also enclosed.

If you have any questions, please call me at 612/330-5956.

Sincerely,

/

&L -L)W, I

Alma Allen-Webb Sr. Environmental Scientist Enclosures

I Page 2 Air Pollutant Emissions Inventory Report for 2001 cc:

ES Record Center Rick Rosvold w/attachments Nancy Stafki w/attachments John Chelstrom w/attachments Lee Eberley w/o attachments Mike Miser - King Plant Brian Anderson-Alliant Techsystems, Granite City, United Healthcare Jim Paris - Black Dog Plant Steve Chapman - West Faribault, Blue Lake, Key City, Inver Hills Scott Anton - High Bridge Plant Karen Olson.- Maple Grove Gloria Tieszen - Minneosta Valley Nick Gamble - Prairie Island Gary Kolle -. PrairieIlscn..

Arthur Zimmerman - Red Wing Plant Loretta Smith - Riverside Plant Bob Catron - Sherco Plant Jim Goodchild - Wescott Plant Nathan Svoboda - Wilmarth Plant

,^ " Minnesota Pollution Control Agency

.1 Air Pollutant Emissions Inventory Report Facility ID:

17100019 Inventory Year. 2001 Page 1 of 3

Contact:

Ebedley, Lee W( 120)

Facility Name:

Location Street Address City/ZIP:

County:

NSP - Monticello Nuclear Plant 2807 W County Road 75 Monticello 55362-9637 Wright Inventory

Contact:

Job TitMe:

Mail Address:

City/St/ZoP:

Eberley, Lee W Air Quality Manager 414 Nicollet Mall Minneapolis, MN 55401-1993

! r &->4 Contact Phone:

Contact Fax:

Contact E-Mail:

(612) 330-5596 (612) 330-6357

-I../

I certify under penalty of law that this document and all attachments were prepared under my direction or supervised by qualified personnel. The Information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I understand that the data provided in this document will be used by the MPCA to calculate a fee, which my facility will be required to pay under Minnesota Rules, part 7002.0025, based on tons of pollutants emitted by the facility.

Signature and Title of Company Official (please write):

4*/'<1

/

/er'zi Date: 3/Z%/::>

Jack' 'Purkis, Plant Manager Name and Title of Company Official (please print):

Return To: Paul Kim (651) 296-7320 or Dana Vanderbosch (651) 282-5849 Minnesota Pollution Control Agency Environmental Outcomes Division Integrated Data Management Unit 520 Lafayette Road N St. Paul, MN 55155-4194

I

.S -

Minnesota Pollution Control Agency Air Pollutant Emissions Inventory Report Facility ID: 17100019 Inventory Year 2001 Operating Schedule Monticello Average Working Schedule

% Annual Throughput l

Percent Hours Days Hours Dec-Mar-Jun-Sep-Heating Per Per Per Feb May Aug Nov Day Week Year EU 001 Boiler 100 11.17 3.26 4078.1 52.2 27.9 0.1 19.8 EU 002 Diesel Generator 11 0

0.096 0.028 35.1 23.9 15.1 15.4 45.6 EU 003 Diesel Generator 12 0

0.079 0.023 28.9 39.4 22.5 17.6 20.4 EU 004 Security Diesel Generator 0

0.023 0.007 8.2 13.4 41.5 12.2 32.9 EU 005 Fire Pump Diesel Engine 0

0.108 0.032 39.6 21.1 18.2 26.5 34.2 EU 006 Diesel Generator 13 0

0.055 0.016 20.0 30.0 25.0 30.0 15.0 EU 007 Temporary Engine > 600 Hp N/A N/A N/A N/A N/A N/A N/A N/A EU 008 Temporary Engine < 600 Hp N/A N/A NIA N/A N/A N/A N/A N/A Minnesota Pollution Control Agency Air Pollutant Emission Inventory Report Facility ID: 17100019 Inventory Year: 2001 Throughput Information Monticello unit unt Desciotion Se gment Desatction Inhrugnout I nougnput Units Quiiur Ash EU 001 EU 002 EU 003 EU 004 EU 005 EU 006 EU 007 EU 008 Boiler

  1. 2 fuel oil 252.18 1000 gallons burned

<0.50 N/A Diesel Generator 11 Diesel 5.97 1000 gallons burned N/A Diesel Generator 12 Diesel 4.91 1000 gallons burned N/A Security Diesel Generator Diesel 0.10 1000 gallons burned N/A Fire Pump Diesel Engine Diesel 0.32 1000 gallons burned N/A Diesel Generator 13 Diesel 2.22 1000 gallons burned N/A Temporary Engine > 600 Hp Diesel N/A 1000 gallons burned N/A I.

N/A Temporary Engine < 600 Hp Diesel N/AT1000 gallons burned N/A N/A



.. II Monticello - 2001 Unit ft Unit Segment SCC Pollutant Emission Calculation Control Control Capture Comb Emissions Descriptio Description Factor Method Equipment (in tons)

EUOO1 Boiler Fuel Oil NOx Test 3.30 TSP/PM AP-42 0.26 SOx AP-42 9.07 EU002; Generator Diesel NOx Test 2.84 003 & 006 TSP/PM AP-42 0.07 SOx AP-42 0.46 Note: NOx emissions from generators I, 12 &13 have been combined. See attached letter(s).

ADDITIONAL FUEL DATA RIU N~P EMISSIONIUNITIS N

MBU OcAUIMMI GBKO IMBU Black bog I I Black bog 2

Black bog 3

5,641,667 106,661 539 Black bog 4

6,046,479 1 f4,315 578 Blue Lake 55,950 Blue Lake 2

75,968 Blue Lake 3

75,984 Blue Lake 4

59,646 Granite City 1

22,859 979 Granite City 2

20,078 860 Granite City 3

24,322 1,042 Granite City 4

18,027 772 High Bridge 3

High Bridge 4

High Bridge 5

5,135,337 306,580 High Bridge 6

9,613,532 147,970 Inver Hills 1

261,147 Inver Hills 2

269,641 Inver Hills 3

250,512 Inver Hills 4

171,551 Inver Hills 5

215,412 Inver Hills 6

231,727 Key City 41 38,032 Key City 5

25,859

Air Pollutant Emissions Inventory Report 2001 Operating Schedule r

r F

F 7

7 I

Jan Feb Marl Apr May Jun Jul Aug Sep Oct Nov Dec Heating Boller 739.3 670.5 735.2 395.8 6.1 0.0 0.0 2.2 67.9 341.4 399.5 720.2 DG 11 2.4 3.4 1.7 2.1 1.5 1.8 1.9 1.7 1.5 3.5 11.0 2.6 DG 12 1.7 3.4 1.5 1.4 3.6 0.0 3.6 1.5 1.8 1.6 2.5 6.3 Security DG 0.4 0.3 0.3 0.3 2.8 0.3 0.4 0.3 0.4 2.0 0.3 0.4 Fire Pump DG 2.66 2.78 2.60 2.60 2.00 2.82 5.04 2.65 9.02 2.26 2.25 2.93 DG 13 1.0 2.0 2.0 2.0 1.0 2.0 2.0 2.0 1.0 2.0 0.0 3.0 Six Month Totals January - June July - December Heating Boiler 2546.9 1531.2 DG 11 12.9 22.2 DG 12 11.6 t_1 17.3 Security DG 4.4

',1_

3.8 Fire Pump DG 15.5

_l 24.2 DG 13 10.0

._i 10.0 Average Working Schedule Il

% Annual Throughput Hrs/Dayl Daysl~k Hrs[Yr Dec -Febl Mar --Mayl Jun -Augl Sep -Nov Heating Boiler 11.17 3.26 4078.1 52.2 27.9 0.1 19.8 LDG 11 0.0961 0.02801 35.1 23.9 15.1 15.4 45.6

[DG 12 0.0791 0.0231 28.9 39.4 22.5 17.61 20.4 LSecurity DG 0.0225 0.00651 8.2 13.4 41.5 12.21 32.9

[Fire Pump DG 0.10841 0.03161 39.6 21.11 18.21 26.51 34.2 lDG 13 l

0.05481 0.01601 20.01 30.01 25.01 30.01 15.0

Air Pollutant Emissions Inventory Report 2001 Throughput Information.

. Janl Feb Mar Atir May Junl Jul Auq Sep Oct NoV1 Dec Total Heating Boller 48592.2 48769.0 43226.7 25258.9 654.2 0.0 0.0 205.9 3633.2 17461.8 20806.5 43569.2 252.18 1,000 Gallons Burned DG 11 408.0 578.0 289.0 357.0 255.0 306.0 323.0 289.0 255.0 595.0 1870.0 442.0 5.97 1,000 Gallons Burned DG 11 289.0 578.0 255.0 238.0 612.0 0.0 612.0 255.0 306.0 272.0 425.0 1071.0 4.91 1,000 Gallons Burned Security DG 5.1 3.8 3.8 3.8 35.8 3.8 5.1 3.8 5.1 25.6 3.8 5.1 0.10 1,000 Gallons Burned Fire Pump DG 21.5 22.5 21.1 21.1 16.2 22.8 40.8 21.5 73.1 183 18.2 23.7 0.32 1,000 Gallons Burned DG 13 111.2 222.4 222.4 222.4 111.2 222.4 222.4 222.4

.111.2 222.4 0.0 333.6 2.22 1,000 Gallons Burned I

Monticello Nuclear Generating Plant Fuel Usage Report Period Covered:

January 1 - June 30, 2001 MPCA Emission Unit Unit No.

Fuel Hours Consumption Operated Rate (gal/hr)I Fuel Amount Used (gal)

NOx Emission Rate 2.3,4,6 (lb/gal)

NOx Emissions (tons)

S02 Emission Rate 45,6 (lb/gal)

S02 Emissions (tons)

PM Emission

'Rate 4,6 (lb/gal)

PM Emissions (tons)

Boiler I EU001 208.6 166,501 DlIl EU002 12.9 170 2,193 D12 EU003 11.6 170 1,972 Security EU004 4.4 12.8 56 Fire Pump EU005 15.5 8.1 126 D13 EU006 10 111.2 1,112 0.0262 2.18 0.0720 5.99 0.0020 0.17 0.4480 0.49 0.0707 0.08 0.0098 0.01 0.4480 0.44 0.0707 0.07 0.0098 0.01 0.6174 0.02 0.0406 0.00 0.0434 0.00 1

0.6174 0.04 0.0406 0.00 0.0434 0.00 0.3602 0.20 0.0707 0.04 0.0098 0.01 Totals 171,960 3.37 f

6.18 0.20

1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
2. Boiler NOx emission rate from 1/1/1996 stack test.
3. D13 NOx emission rate from 10/18 2000 stack test.
4. Boiler emission rates from MPCA Table EC-02.1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to lbs/gal)
5. Assumes 0.5% S in fuel.
6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.

.~1 Monticello Nuclear Generating Plant Fuel Usage Report Period Covered:

July 1 - December 31, 2001 MPCA Emission Unit Unit No.

Fuel Hours Consumption Operated Rate (gallhr) I Fuel Amount Used (gal)

NOx Emission Rate 2,3,4.6 (lb/gal)

NOx Emissions (tons)

S02 Emission Rate 4.5,6 (lb/gal)

S02 Emissions (tons)

PM Emission Rate 4,6 (lb/gal)

PM Emissions (tons)

Boiler I EUOOI 208.6.

85,677 DII EU002 22.2 170 3,774 D12 EUOO3 17.3 170 2,941 Security EU004 3.8 12.8 49 Fire Pump EUOO5 24.2 8.1 196 D13 EUOO6 10 111.21 1,112 0.0262 1.12 0.0720 3.08 0.0020 0.09 0.4480 0.85 0.0707 0.13 0.0098 0.02 0.4480 0.66 0.0707 0.10 0.0098 0.01 0.6174 0.02 0.0406 0.00 0.0434 0.00 0.6174 0.06 0.0406 0.00 0.0434 0.00 0.3602 0.20 0.07071 0.04 0.0098 0.01 Totals 93,749 2.90 3.37 0.13

1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
2. Boiler NOx emission rate from 1/1/1996 stack test.
3. D 13 NOx emission rate from 10/18 2000 stack test.
4. Boiler emission rates from MPCA Table EC-02.1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to lbs/gal)
5. Assumes 0;5% S in fuel.
6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.