.2 i

j XcelEnergysM 414 Nicollet Mall Minneapolis, Minnesota 55401-1993 March 27, 2003 Mr. Paul Kim Minnesota Pollution Control Agency Environmental Outcomes Division Integrated Data Management Unit

.520 Lafayette Road N St. Paul, MN 55155 Re:

2002 Air Emission Inventory Reports Enclosed are Northern States Power d/b/a Xcel Energy's 2002 Air Emission Inventory Reports complet6d and signed for the following facilities owned and operated by Northern States Power Company d/b/a Xcel Energy:

Facility Name Allen S. King Alliant Techsystems Black Dog Blue Lake General Office Granite City High Bridge Inver Hills Key City Maple Grove

  • Facility ID #

16300005 05300697 03700003 13900010 05300855 00900021 12300012 03700015

  • 01300015 05300898 Facility Name Minnesota Valley Monticello Prairie Island Red Wing Riverside Sherburne County United Healthcare Wescott West Faribault Wilmarth Facility ID #

02300012 17100019 04900030 04900005 05300015 14100004 05300698 03700064 13100003 01300015 Northern States Power d/b/i Xcel Energy also owns and operates three (3) oil-fired generators located at the United Hospital Facility~in St. Paul. These units are included in the facility Emissions Inventory Report which is signed and submitted by United Hospital.

In addition, enclosed are supplemental information sheets for several facilities to assist in the calculations for the Emission Summaries.

If you have any questions, please call me at 612-330-7630.

Sincerely, Sarah A. Butrymowicz.

Environmental Analyst III Enclosures

Page 2 2002 Air Emission Inventory Reports cc:

Environmental Services Record Center Lee Eberley, w/o attachments Rick Rosvold, w/attachments Nancy Stafki, w/attachments John Chelstrom, w/attachments Alma Allen-Webb w/attachments Nancy Stafki - General Office Karen Olson - Maple Grove Mike Miser - Allen S.. King Jim Paris - Black Dog Scott Anton - High Bridge Carl Bayley -Riverside

' -r._

Mary Dieltz - Sherco Gloria Tieszen - Mn Valley Gary Kolle - Prairie Island Rick Latsch - Monticello Nathan Svoboda - Wilmarth Arthur Zimmerman - Red Wing Ron Shilts - Wescott Steve Chapman - West Faribault, Blue Lake, Key City, Inver Hills Brian Anderson - United Healthcare, Alliant Techsystems, Granite City

Minnesota Pollution Control Agency Air PoUutant Emissions Inventory Report Facility ID:

17100019 Inventory Year: 2002 Page 1 of 3

Contact:

Ebedey. LeeW( 110)

.Yo-m Eu/

fitiaeIIc VPiIcar Plaif Facility Name:

Location Street Address:

City/ZIP:

County:

NSp db rcc Enzrgy It:_

  • 2807 W Highway 75 Monticello 55362

.Wright Ilo4et~ear-Inventory

Contact:

Job

Title:

Mail Address:

.City/St/ZlP:

EbedeyLee W Air Quality Manager 414 Nicollet Mall Minneapolis, MN 55401-1993 Contact Phone:

Contact Fax:

Contact E-Mail:

(612) 330-5596 (612) 330-6357 I certify under penalty of lawi that this document and all attachments were prepared under my direction or supervised by qualified personnel. The Information submitted is, to the best of my knowledge and belief, true, accurate, and complete. l understand that the data provided in this document will be used by the MPCA to calculate a fee, which my facility will be required to pay under Minnesota Rules, part 7002:0025, based on tons of pollutants emitted by the facility.

Signature and Title of Company Official (please wnte):

Date:

.Name and Title of Company Official (please print):

Jac* f;-.iLr QI

  • i'* (y o NmLsM Return To: Paul Kim (651) 296-7320 or Michael Smith (651) 282-5849 Minnesota Pollution Control Agency Environmental Outcomes Division Integrated Data Mariagement Unit 520 Lafayette Road N

-St. Paul, MN 55155-4194

G 4 -

Minnesota Pollution Control Agency Air Pollutant Emissions Inventory Report Facility ID: 17100019 Inventory Year: 2002 Page 2 of 3 Contact Eberley, Lee W( 110)

Operating Schedule Average Working Schedule

  • % Annual Throughrput Percent Hours Days Heating Per Per Day Week Hours Dec-Mar-Jun-Per Feb.

May Aug Year Sep-.

Nov EU 001 Boiler EU 002 Diesel Generator 11 EU 003 Diesel Generator 12 EU 004 Security Diesel Generator EU 005 Fire Pump Diesel Engine EU 006 Diesel Generator 13 EU 007 Temporary Engine > 600 Hp EU 008 Temporary Engine < 600 Hp 100 13.390 3.900 4888.9 43.8 30.4 0.0 25.7 0

0.075 0.022 27.4 27.4 25.9 26.3 20.1 0

0.091 0.027 33.3 25.5 37.2 19.2 18.0 0

0.021 0.006 7.8 11.5 35.9 16.7 35.9 0

0.105 0.031 38.3 24.4 22.6

  • 31.4 21.6 0

0.058 0.017 21.0 23.8 23.8 28.6 23.8

-NIA N/A N/A N/A NIA N/A NIA N/A I

N/A N/A NMA NIA N/A IN/A N/A IN/A NJA N/A N/A N/A I N/A N/A N/A

1 Minnesota Pollution Control Agency Air Pollutant Emissions Inventory Report Facility ID: 17100019 Inventory Year: 2002 Page 3 of 3 Contact Eberley, Lee W( 110)

Throughput Information Unit Unit Segment Description Throughput Throughput Sulfur Ash Description Units EU 001 EU 002 EU 003 EU 004 EU 005 EU 006 EU 007 EU 008 Boiler Diesel 271.74 1000 gallons burned

<0.05 NIA Diesel Generator 11 Diesel 4.66 1000 gallons burned

<0.05 NIA Diesel Generator 12 Diesel 5.66 1000 gallons burned

<0.05 N/A Security Diesel Generator Diesel 0.12 1000 gallons burned

<0.05 N/A Fire Pump Diesel Engine Diesel 0.31 1000 gallons bumed

<0.05 NIA Diesel Generator 13 Diesel 2.34 1000 gallons burned

<0.5 N/A Temporary Engine > 600 Hp Diesel N/A

. 1000 gallons burned.

N/A Temporary Engine c 600 Hp Diesel NIA 1000 gallons burned NIA NIA Temporary Engine <600 Hp Diesel N/A 1000 gallons burned NIA N/A

Monticello Nuclear Plant 1117 100019 Units UnitDescription Seg Seg Description SCC Pollutant Emission Factor (Ib/AIMIBTU Calculation Throughput Throughput Control %

Capture % Combined%

Actual MIethod (gallons)

(fM13TU)

I (Tons)

I IAppvd Stack* I I

EU006 IDiesel Engine 13 l l1Diesel 201001021NOx l

2.57 (10/2000) 2,340001 320.581 l

l 0.41 l

1. Assume heat value of 137.000 IITU/Gallon
2. For other units and pollutants, use appropriate AP-42 equations.

I

Unit#

Unit Segment SCC Pollutant Emission Calculation Control Control Capture Comb Emissions Description Description Factor Method Equipment %

(in tons)

EU001 Boiler Fuel Oil NOx Test

._._3.56 TSP/PM AP-42 0.27 SOx AP-42 9.78

EU002, Generator Diesel NOx Test 2.73 003, &

0 0 6 TSP/PM AP-42 0.06 SOx AP-42 0.45 Note: NOx emissions from generators 11, 12 & 13 have been combined. See attached letter(s).

Air Pollutant Emissions Inventory Report 2002 Operating SchecI[ule 1_________

f I

.sB '

I

  • fk,..iJi-;k-AHP I

'ia-L--I-1 II TY.L frj

-I H

i-ts

[flJ-V.

fl Heatl Boil~ri 742.2 674.4 737.4 500.2 249.5 0.0 0.0 1.5 39.3 541.7 676.2 726.5 J-G 11 R

1.9 1.6 1.9 3.5 1.7 1.6 3.7 2.0 1.8 2.1 1.6 4.0 QG12.7.-.Mf 9

1.6 1.5 1.1 7.4 3.9 0.0 4.5 1.9 2.0 1.8 2.2 5.4 Sec0rity)DG 0.4 0.2 0.4 0.3 2.1 0.3 0.3 0.7 0.4 0.3 2.1 0.3 FireiPd'!mpIDG;S`

4.83 2.26 2.96 2.18 3.53 6.36 2.78 2.87 2.23 2.36 3.69 2.25 DG 13,1 1W 2.0 1.0 2.0 2.0 1.0 3.0 1.0 2.0

. 2.0 1.0 L

2.0 2.0 Htig;Boibei 2903.7 1985.2 PG Q1 '

12.2 15.2 DGi2z+/-Jk-t 15.5 1

17.8 Sb~iW0G:

3.7 4.1 Firfii ifPJDGP 22.1 16.2 D[G-3j11.0 10.0 WAY I ftqdiWdtk i FWSnhecd l1.&l h

U t

,,- WI)dVl ay WWWWy~RI Wle-HNIYt-Dc I

e IaldFbl.-Mr-a flk-Audc l!Seij1NbV I57,W4%

9tlj 1 1Bolj r16 13.39 3.90 4888.9 43.8 30.4 0.0 25.7 100.0 I

G-0.0750 0.0219 27.4 27.4 25.9 26.6 20.1 100.0 OGi,,l lwj 0.0912 0.0266 33.3 25.5 37.2 19.2 18.0 100.0 Se6 iri G 0.0214 0.0062 7.8 11.5 35.9 16.7 35.9 100.0 fit F4,4-10-m 0.10491 0.0306 38.3 24.4 22.6 31.4 21.6 100.0 DGP-1 31

-i 0.0575 0.0168 21.0 23.8 23.8 28.6 23.8 100.0

.e Air Pollutant Emissions Inventory Report 2002 Throughput Information

. ;. f r M~ ayl,.'&

-Jim k*

SJuI

,i-$Au0lI;

@:O'~t;<;EN6V~e De-cL.

Total HetingCBoite'r 45432.7 39276.3 45441.7 25839.7 12327.6 82.6 0.0 89.5 2108.4 27322.3 34751.1 39072.3 271.74 1,000 Gallons Burned 323.0 272.0 323.0 595.0 289.0 272.0 629.0 340.0 306.0 357.0 272.0 680.0 4.66 1,000 Gallons Burned D

272.0 255.0 187.0 1258.0 663.0 0.0 765.0 323.0 340.0 306.0 374.0 918.0 5.66 1,000 Gallons Burned Sduty DGi 5.1 2.6 5.1 26.9 3.8 3.8 9.0 5.1 3.8 26.9 26.9 3.8 0.12 1,000 Gallons Burned lfiieiimp DG:'v 39.1 18.3 24.0 17.7 28.6 51.5 22.5 23.2 18.1 19.1 29.9 18.2 0.31 1,000 Gallons Burned DQ-222.4 111.2 222.4 222.4 111.2 333.6 111.2 222.4 222.4 111.2 222.4 222.4 2.341,000 Gallons Burned MW ifd~tleft;$ae Re HE F,-~'.

Qts..JaaOJei-:W il.*;'l R S

,Z S-

~

I FJAb U-6 J QU ber Annual Total Heati g. B l!e6 168.40 103.34 271.74 1,000 Gallons Burned DGl1 2.07 2.58 4.66 1,000 Gallons Burned DG 2z 2.64 3.03 5.66 1,000 Gallons Burned SbOufitWDG' Hill 0.05 0.08 0.12 1,000 Gallons Burned FjirPpff rim 0.18 0.13 0.31 1,000 Gallons Burned DGi,3-.

j4:,'

1.22 1.11 2.341,000 Gallons Burned

I Monticello Nuclear Generating Plant Fuel Usage Report Period Covered:
Ji~ai;R
>Z;>pn~doIq MPCA Emission Unit Unit No.

Fuel Hours Consumption Operated Rate (2al/hr) 1 Fuel Amount Used (gal)

NOx Emission Rate 2,3,4,6 (lb/aal)

NOx Emissions (tons)

S02 Emission Rate 4,5,6 (lb/Lan)

S02 Emissions (tons)

PM Emission Rate 4,6 (lb/aal)

PM Emissions (tons)

Boiler I EUOO1 208.6 1.^. 168,401 DII EU002 ;i;2.2 170 2,074 D12 EU003

15.5 170 2,635 Security EU004 a

12.8 47 Fire Pump EU005

/

22,.

8.1 179 D13 EU006 I; (t'j god.0 111.2 1,223 0.0262 2.20 0.0720 6.06 0.0020 0.17 0.4480 0.46 0:0707 0.07 0.0098 0.01 0.4480 0.59 0.0707 0.09 0.0098 0.01 0.6174 0.01 0.0406 0.00 0.0434 0.00 0.61741 0.06 0.0406 0.00 0.0434 0.00 0.3602 0.22 0.0707 0.041 0.0098 0.

Totals 174,559 3.55 6.28 0.20

1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
2. Boiler NOx emission rate from 1/1/1996 stack test.
3. D13 NOx emission rate from 10/18 2000 stack test.
4. Boiler emission rates from MPCA Table EC-02.1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to Ibs/gal)
5. Assumes 0.5% S in fuel.
6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.

I Monticello Nuclear Generating Plan-t Fuel Usage Report Period Covered:

MPCA Emission Unit Unit No.

. Fuel Fuel 11ours Consumption Amount Operated Rate (gal/hr) 1 Used (gal)

NOx Emission Rate 2,3,4,6 (lb/gal)

NOx Emissions (tons)

S02 Emission Rate 4l6 (Ilb/gal)

  • S02 Emissions (tons)

PM Emission Rate 4,6 (Mb/gal)

PM Emissions (tons)

Boiler I EUOOI-208.6

' 103;344 DIl EU002 15S2170 2,584 D12 EU003 Z:,,

17.8 170 3,026 Security EU004 4'1 12.8 52 Fire Pump EU005

-I7. 16.2 8.1 1 131 D13 EU006 1.'; ',10'.0 111.21 1,112 0.0262 1.35 0.0720 3.72 0.0020 0.10 0.4480 0.58 0.0707 0.09 0.0098 0.01 0.4480 0.68 0.0707 0.11 0.0098 '

0.01 0.6174 0.02 0.0406 0.00 0.0434 0.00 0.6174 0.04 0.0406 0.00 0.0434 0.00 0.3602 0.20 0.0707

'^

0.04 0.0098 0.01 Totals 110,249 2.87 3.96 0.14

1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
2. Boiler NOx emission rate from 1/1/1996 stack test.
3. D13 NOx emission rate from 10/18 2000 stack test.
4. Boiler emission rates from MPCA Table EC-02. 1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to lbs/gal)
5. Assumes 0.5% S in fuel.
6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.