Notification Response to GL 2004-01, Requirements for Steam Generator Tube Inspections (Tac. MC4821)
ML051920214
Person / Time
Site: Fort Calhoun 
Issue date: 07/12/2005
From: Wang A
NRC/NRR/DLPM/LPD4
To: Ridenoure R
Omaha Public Power District
Wang A, NRR/DLPM, 415-1445
References
GL-04-001, TAC MC4821
Download: ML051920214 (3)


Text

July 12, 2005 Mr. R. T. Ridenoure Vice President - Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

Post Office Box 550 Fort Calhoun, NE 68023-0550

SUBJECT:

FORT CALHOUN UNIT 1 - NOTIFICATION REGARDING THE RESPONSE TO GL 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4821)

Dear Mr. Ridenoure:

On August 30, 2004, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements for Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant Technical Specifications) in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50.

By letter dated October 29, 2004, Omaha Public Power District responded to GL 2004-01 for Fort Calhoun Station, Unit 1. The NRC staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Fort Calhoun Station, Unit 1. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

If you have any questions regarding this matter, please contact Alan B. Wang at (301) 415-1445.

Sincerely,

/RA/

Alan B. Wang, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-285 cc: See next page

July 12, 2005 Mr. R. T. Ridenoure Vice President - Chief Nuclear Officer Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

Post Office Box 550 Fort Calhoun, NE 68023-0550

SUBJECT:

FORT CALHOUN UNIT 1 - NOTIFICATION REGARDING THE RESPONSE TO GL 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4821)

Dear Mr. Ridenoure:

On August 30, 2004, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, Requirements for Steam Generator Tube Inspections. The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees steam generator (SG) tube inspection programs comply with the existing tube inspection requirements (the plant Technical Specifications) in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50.

By letter dated October 29, 2004, Omaha Public Power District responded to GL 2004-01 for Fort Calhoun Station, Unit 1. The NRC staffs review of your response to the GL did not identify any concerns with the inspection practices employed at Fort Calhoun Station, Unit 1. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

If you have any questions regarding this matter, please contact Alan B. Wang at (301) 415-1445.

Sincerely,

/RA/

Alan B. Wang, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-285 DISTRIBUTION:

PUBLIC PDIV-2 Reading PKlein RidsNrrDlpmLpdiv (HBerkow)

MYoder RidsNrrPMAWang JTerrell cc: See next page RidsNrrLALFeizollahi DCollins RidsOgcRp RidsAcrsAcnwMailCenter RidsRegion4MailCenter (KKennedy)

RidsNrrDlpmLpdiv2 ACCESSION NO.: ML051920214 NRR-106 OFFICE PDIV-2/PM PDIV-2/LA PDIV-2/(A)SC NAME AWang:sp LFeizollahi DCollins DATE 7/12/05 7/12/05 7/12/05 DOCUMENT NAME: E:\\Filenet\\ML051920214.wpd OFFICIAL RECORD COPY

June 2005 Ft. Calhoun Station, Unit 1 cc:

Winston & Strawn ATTN: James R. Curtiss, Esq.

1400 L Street, N.W.

Washington, DC 20005-3502 Chairman Washington County Board of Supervisors P.O. Box 466 Blair, NE 68008 Mr. John Hanna, Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 310 Fort Calhoun, NE 68023 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-4005 Ms. Sue Semerera, Section Administrator Nebraska Health and Human Services Systems Division of Public Health Assurance Consumer Services Section 301 Centential Mall, South P.O. Box 95007 Lincoln, NE 68509-5007 Mr. David J. Bannister, Manager Fort Calhoun Station Omaha Public Power District Fort Calhoun Station FC-1-1 Plant P.O. Box 550 Fort Calhoun, NE 68023-0550 Mr. John B. Herman Manager - Nuclear Licensing Omaha Public Power District Fort Calhoun Station FC-2-4 Adm.

P.O. Box 550 Fort Calhoun, NE 68023-0550 Mr. Daniel K. McGhee Bureau of Radiological Health Iowa Department of Public Health Lucas State Office Building, 5th Floor 321 East 12th Street Des Moines, IA 50319