TABLE 4.2-1 SECTION A. MISCELLANEOUS INSPECTIONS Required Examination Area Required Examination Methods 10-Year Interval Inspection Item No.
1.1 Remarks Deleted 1.2 Low Head SIS piping located in valve pit Visual Non-applicable This pipe shall be visually inspected once per 18 months.
1.3 Primary Pump Flywheel Low Pressure Turbine Rotor
- See remarks Visual and Magnetic Particle or Dye Penetrant See remarks See remarks Inspect once every 20 years by a qualified in-place UT examination over the volume from the inner bore of the flywheel to the circle of one-half the outer radius or a surface examination (MT and/or PT) of exposed surfaces defined by the volume of the disassembled flywheels.
The provisions of Specification 4.0.2 are not applicable.
100% of blades every six operating years. Inspections are normally performed concurrent with LP turbine rotor disk and hub inspections.