Rick Ennis - SPLB RAI Followup Page 1 From:

Rick Ennis To:

Len Gucwa Date:

6/27/05 2:08PM

Subject:

SPLB RAI Followup

Len, Following the call, Devender came by and asked that I followup with you on SPLB-A-28 (which will be renumbered as SPLB-A-27). He wanted to make sure that the response addresses whether the discussion in the following two sentences in Supplement 28, Attachment 1, page 10, "Suction pressure trip setpoint" paragraph applies to with runback or without runback:

"The minimum calculated RFP suction pressure following the trip of one CP at EPU will be approximately 124 psig. There is sufficient margin between the minimum transient RFP suction pressure and the current RFP suction pressure trip setpoint to ensure RFP operation during normal operation and the loss of one CP transient."

thanks, Rick 301-415-1420 CC:

Craig Nichols; Devender Reddy; James Tatum; Jim DeVincentis; Ronda Daflucas

.1 Ic:\\temrAGW100001

.TMP Paae I1 I c:\\temD\\GWIOOOOI.TMP Paae I Mail Envelope Properties (42C040B4.483:15: 20516)

Subject:

Creation Date:

From:

Created By:

SPLB RAI Followup 6/27/05 2:08PM Rick Ennis RXE(nrc.gov Recipients TWGWPOOI.HQGWDOO1 DKR2 CC (Devender Reddy) owf2_po.OWFNDO JETI CC (James Tatum)

Action Delivered Opened Delivered Date & Time 06/27/05 02:08PM 06/27/05 02:08PM 06/27/05 02:08PM entergy.com cnichol CC (Craig Nichols) jdevinc CC (Jim DeVincentis)

LGUCW90 (Len Gucwa) rdafluc CC (Ronda Daflucas)

Transferred 06/27/05 02:09PM Post Office TWGWPOO1.HQGWDOOI oxvf2_po.OWFNDO Delivered 06/27/05 02:08PM 06/27/05 02:08PM Route entergy.com Files MESSAGE Options Auto Delete:

Expiration Date:

Notify Recipients:

Priority:

Reply Requested:

Return Notification:

Concealed

Subject:

Security:

To Be Delivered:

Status Tracking:

Size 1410 Date & Time 06/27/05 02:08PM No None Yes Standard No None No Standard Immediate Delivered & Opened