June 9, 2005 Mr. M. R. Blevins Senior Vice President &
Chief Nuclear Officer TXU Power Attn: Regulatory Affairs Department P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES), UNIT 2 -
RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4811)
Dear Mr. Blevins:
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, "Requirements For Steam Generator Tube Inspections." The purpose of the GL 2004-01 was to obtain information that would enable the NRC staff to determine whether the licensees steam generator tube inspection programs comply with the existing tube inspection requirements (the plant Technical Specifications in conjunction with Appendix B to Part 50 of Title 10 of the Code of Federal Regulations).
By letter dated October 14, 2004, TXU Generation Company LP (the licensee), responded to GL 2004-01 for CPSES, Unit 2. The NRC staffs review of the licensees response to the GL did not identify any concerns with inspection practices employed at the CPSES, Unit 2. The NRC staff, therefore, concludes the CPSES, Unit 2 inspection practices are in compliance with the existing tube inspection requirements.
If you have any questions regarding this matter, please contact me at (301) 415-1476.
Sincerely,
/RA/
Mohan C. Thadani, Senior Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page
June 9, 2005 Mr. M. R. Blevins Senior Vice President &
Chief Nuclear Officer TXU Power Attn: Regulatory Affairs Department P. O. Box 1002 Glen Rose, TX 76043
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES), UNIT 2 -
RESPONSE TO GENERIC LETTER 2004-01, REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS (TAC NO. MC4811)
Dear Mr. Blevins:
On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, "Requirements For Steam Generator Tube Inspections." The purpose of the GL 2004-01 was to obtain information that would enable the NRC staff to determine whether the licensees steam generator tube inspection programs comply with the existing tube inspection requirements (the plant Technical Specifications in conjunction with Appendix B to Part 50 of Title 10 of the Code of Federal Regulations).
By letter dated October 14, 2004, TXU Generation Company LP (the licensee), responded to GL 2004-01 for CPSES, Unit 2. The NRC staffs review of the licensees response to the GL did not identify any concerns with inspection practices employed at the CPSES, Unit 2. The NRC staff, therefore, concludes the CPSES, Unit 2 inspection practices are in compliance with the existing tube inspection requirements.
If you have any questions regarding this matter, please contact me at (301) 415-1476.
Sincerely,
/RA/
Mohan C. Thadani, Senior Project Manager, Section 1 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-445 and 50-446 cc: See next page DISTRIBUTION PUBLIC PDIV-1 Reading RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDlpmLpdiv1 (DTerao)
RidsNrrPMMThadani RidsNrrLADBaxley RidsRgn4MailCenter (AHowell) Accession No. ML051520353 OFFICE PDIV-1/PM PDIV-1/LA PDIV-1/SC NAME MThadani DBaxley DTerao DATE 6/9/05 6/9/05 6/9/05 OFFICIAL RECORD COPY
Comanche Peak Steam Electric Station cc:
Senior Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 2159 Glen Rose, TX 76403-2159 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011 Mr. Fred W. Madden, Director Regulatory Affairs TXU Generation Company LP P. O. Box 1002 Glen Rose, TX 76043 George L. Edgar, Esq.
Morgan Lewis 1111 Pennsylvania Avenue, NW Washington, DC 20004 County Judge P. O. Box 851 Glen Rose, TX 76043 Environmental and Natural Resources Policy Director Office of the Governor P. O. Box 12428 Austin, TX 78711-3189 Mr. Richard A. Ratliff, Chief Bureau of Radiation Control Texas Department of Health 1100 West 49th Street Austin, TX 78756-3189 Mr. Brian Almon Public Utility Commission William B. Travis Building P. O. Box 13326 1701 North Congress Avenue Austin, TX 78701-3326 Ms. Susan M. Jablonski Office of Permitting, Remediation and Registration Texas Commission on Environmental Quality MC-122 P. O. Box 13087 Austin, TX 78711-3087 Terry Parks, Chief Inspector Texas Department of Licensing and Regulation Boiler Program P. O. Box 12157 Austin, TX 78711