E-mail from Holmberg to Krohn Containment Penetration Elevated Temperature Readings (Point Beach)
ML051520262
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 12/23/2003
From: Mel Holmberg
NRC/RGN-III
To: Paul Krohn
NRC/RGN-III
References
FOIA/PA-2004-0282
Download: ML051520262 (1)


Text

I Patrick Louden - Containment Penetration Elevated Temperature Readings (Point Beach)

Pagel 1l From:

To:

Date:

Subject:

Melvin Holmberg Krohn, Paul 12/23/03 1:25PM Containment Penetration Elevated Temperature Readings (Point Beach)

Paul, Attached is my evaluation of the containment penetration elevated temperature readings at Point Beach.

(Reference-PB OPR 000096 (CAP051854)).

I agree with the licensee operability calculation, but I think they have a difficult challenge ahead to accept this condition as a permanent design change. See my attached technical evaluation. Also, you might check with Hans Ashar at NRR about how the licensee applies the ACI standards whenlif they implement a design change to accept this condition.

Mel CC:

Ross Landsman Hansraj Ashar; Hills, David; Kunowski, Michael; Louden, Patrick; Neurauter, James;