ML051470110

From kanterella
Jump to navigation Jump to search
Summary of End of Cycle Public Meeting with Entergy Operations, Inc. on Grand Gulf Nuclear Station Performance for Period of 01/01/2004 - 12/31/2004
ML051470110
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 05/25/2005
From: Johnson W
NRC/RGN-IV/DRP/RPB-A
To: Gerald Williams
Entergy Operations
References
Download: ML051470110 (13)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I V 611 RYAN PLAZA DRIVE, SUITE 400 ARLINGTON, TEXAS 76011-4005 May 25, 2005 Mr. George Williams Vice President, Nuclear Operations Grand Gulf Nuclear Station Entergy Operations, Inc.

P.O. Box 756 Port Gibson, Mississippi 39150

SUBJECT:

SUMMARY

OF GRAND GULF NUCLEAR STATION END-OF-CYCLE PUBLIC MEETING

Dear Mr. Williams:

This refers to the End-of Cycle public meeting conducted at Port Gibson, MS on May 12, 2005, between the NRC and your staff. The participants discussed performance at Grand Gulf for the period January 1 through December 31,2004.

The attendance list is enclosed with this summary (Enclosure 1). A copy of the presentation slides is also enclosed (Enclosure 2).

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.qov/readinq-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this matter, we will be pleased to discuss them with you.

Sincerely, William-D. Johnson, Chief Project Branch A Division of Reactor Projects Docket No:

50-416 License No:

NPF-29

Enclosures:

1. Attendance List
2. NRC Presentation Slides

Entergy Operations, Inc.

cc w/enclosures:

George A. Williams, Site Vice President Grand Gulf Nuclear Station Entergy Operations, Inc.

P.O. Box 756 Port Gibson, MS 39150 Michael Wells Supervisor, District 2 Claiborne County 102 Evergreen Street Port Gibson, MS 39150 Charles Shorts, President of Board Supervisor, District 5 Claiborne County 4007 Pine Grove Road Port Gibson, MS 39150 Martha Lott, Board Vice President District 4, Claiborne County P.O. Box 279 Port Gibson, MS 39150 Diane Davaul Claiborne County Tax Assessor/Collector P.O. Box 469 Port Gibson, MS 39150 The Honorable Amelda Arnold Mayor, Town of Port Gibson P.O. Box 607 Port Gibson, MS 39150 The Honorable Haley Barbour Governor, State of Mississippi P.O. Box 139 Jackson, MS 39205 Robert R. Latham, Jr., Director Mississippi Emergency Management Agency P.O. Box 4501, Fondren Station Jackson, MS 39296-4501 The Honorable Edward Brown Mayor, Town of St. Joseph P.O. Box 217 St. Joseph, LA 71366 The Honorable Alex Davis Mayor, Town of Newellton P.O. Box 477 Newellton, LA 71357 Rick Foster, Director Tensas Office of Emergency Preparedness P.O. Box 768 St. Joseph, LA 71366 Mike Henry State Liaison Officer Department of Environmental Quality P.O. Box 4313 Baton Rouge, LA 70821-4313 Federal Emergency Management ATTN: Kenneth 0. Burris, Jr.

3003 Chamblee Tucker Road Atlanta, GA 30341 Col. Jeff Smith, Acting Assistant Director Louisiana Office of Homeland Security and 7667 Independence Blvd.

Baton Rouge, LA 70806 Federal Emergency Management Agency ATTN: Gary Jones, Regional Director Region VI, Federal Center 800 North Loop 288 Denton, TX 76209-3698 Allen Burks, Supervisor, District 1 Claiborne County 2047 Woodvine Road Lorman. MS 39069 Agency, Region IV Regional Director Emergency Preparedness Mott Headley, Jr.

Supervisor, District 3 Claiborne County 1 154 Mott Headley Road Port Gibson, MS 39150 Eddie Walls, Jr.

Ward 1 P.O. Box 239 Port Gibson, MS 39150

Entergy Operations, Inc Vera Johnson Ward 2 605 Greenwood St.

Port Gibson, MS 39150 Kenneth Davis Ward 3 305 Cedar St.

Port Gibson, MS 39150 Thomas Russum Ward 4 P.O. Box 400 Port Gibson, MS 39150 Leslie Case Ward 5 214 Claremont Drive Port Gibson, MS 39150 Michael A White Ward 6 206 Mimosa St.

Port Gibson, MS 39150 Vanessa Waters City Clerk P.O. Box 48 Pattison, MS 39144 Paul Winfield City Attorney 1129 Openwood Street Vicksburg, MS 39181 Roderick Devoual, Director Port GibsonlClaiborne County Civil Defense P.O. BOX 558 Port Gibson, MS 39150 James Jackson, Sr.

Claiborne County Election Commissioner, District # 1 338 Gordon Station Annex Port Gibson, MS 39150 James Gray Claiborne County Election Commissioner, District #2 P.O. Box 105 Port Gibson, MS 39150 Gary Knight Claiborne County Election Commissioner, District #3 116 Willows Lane Port Gibson, MS 39150 Corlean Hughes Claiborne County Election Commissioner, District #4 P.O. Box 161 Hermanville, MS 39086 A. E. Tindell Board of Alderpersons District A P.O. Box 164 St. Joseph, LA 71366 Jack Grace, Jr.

Board of Alderpersons District B P.O. Box 75 St. Joseph, LA 71366 Jimmy S. Clark Board of Alderpersons District C P.O. Box 467 St. Joseph, LA 71366 Telma Bradford Board of Alderpersons District D P.O. Box 127 St. Joseph, LA 71366 Herman Watson Board of Alderpersons District E P.O. Box 761 St. Joseph, LA 71366

Entergy Operations, Inc Madaline Gibbs Town Attorney 503 Hancock Street St. Joseph, LA 71366 Mercedes Williams Municipal Clerk P.O. Box 414 St. Joseph, LA 71366 Maria Cooper, Mayor Town of Waterproof P.O. Box 35 Waterproof, LA 71375 Robert Bethel, 111 Town Council Member P.O. Box 135 Waterproof, LA 71375 Bertha Brown Town Council Member P.O. Box 576 Waterproof, LA 71375 Clara Robinson Town Council Member P.O. Box 121 Waterproof, LA 71375 Herbert Williams Town Council Member P.O. Box 106 Waterproof, LA 71375 Caldwell A. Flood Town Council Member P.O. Box 338 Waterproof, LA 71375 Connie McKeel Town Council Member P.O. Box 139 Waterproof, LA 71375 Emmett Adams Tensas Parish Police Jurors District 1 P.O. Box 631 Newellton, LA 71357 Danny Clark Tensas Parish Police Jurors District 2 P.O. Box 262 Newellton, LA 71357 Jane Netterville, Vice President Tensas Parish Police Jurors District 3 St. Joseph, LA 71366 William Trevillion Tensas Parish Police Jurors District 4 Waterproof, LA 71375 Roderick Dale Webb Tensas Parish Police Jurors District 5 P.O. Box 516 St. Joseph, LA 71366 Roy K. Smith Tensas Parish Police Jurors District 6 P.O. Box 539 Waterproof, LA 71375 Woodrow W. Wiley, Jr., President Tensas Parish Police Jurors District 7 P.O. Box 33 Waterproof, LA 71375 Edwin Britt, Pro Tem Board of Alderpersons P.O. Box 398 Newellton, LA 71357 Clara Bass Board of Alderpersons P.O. Box 266 Newellton, LA 71357 Billy Mitchell Board of Alderpersons P.O. Box 632 Newellton, LA 71357 P.O. BOX 125-9 HC-61, BOX 276

Entergy Operations, Inc.

Kent Morgan Board of Alderpersons P.O. Box 684 Newellton, LA 71357 David Delaney Board of Alderpersons P.O. Box 621 Newellton, LA 71357 James Paxton Town Attorney P.O. Box 97 St. Joseph, LA 71366 Ronda King City Clerk P.O. Box 477 Newellton, LA 71357 Jim Hood, Attorney General State of Mississippi P.O. Box 220 Jackson, MS 39225 Phil Bass, Director Office of Pollution Control Department of Environmental Quality P.O. Box 10385 Jackson, MS 39209 The Honorable Kathleen Blanco Governor, State of Louisiana P.O. Box 94004 Baton Rouge, LA 70804-9004 Administrator Department of Environmental Quality P.O. Box 4313 Baton Rouge, LA 70821-4313 Coney Johnson Claiborne County Election Commissioner District 5 5088 Hwy 547 Port Gibson, MS 391 50 Senior Vice President Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Wise, Carter, Child & Caraway P.O. Box 651 Jackson, MS 39205 Winston & Strawn LLP 1700 K Street, N.W.

Washington, DC 20006-3817 Jay Barkley, Chief Energy & Transportation Branch Environmental Compliance and Enforcement Division Mississippi Department of Environmental Quality P.O. Box 10385 Jackson, MS 39289-0385 President, District 1 Claiborne County Board of Supervisors P.O. Box 339 Port Gibson, MS 39150 General Manager Grand Gulf Nuclear Station Entergy Operations, Inc.

P.O. Box 756 Port Gibson, MS 39150 The Honorable Charles C. Foti, Jr.

Attorney General Department of Justice State of Louisiana P.O. Box 94005 Baton Rouge, LA 70804-9005 Governor Haley Barbour Office of the Governor State of Mississippi Jackson, MS 39201 Jim Hood, Attorney General State of Mississippi P.O. Box 22947 Jackson, MS 39225 and Chief Operating Officer

Entergy Operations, Inc Dr. Brian W. Amy State Health Officer State Board of Health P.O. Box 1700 Jackson, MS 39215 Robert W. Goff, Program Director Division of Radiological Health Mississippi Dept. of Health P.O. Box 1700 Jackson, MS 39215-1700 Director Nuclear Safety 8, Licensing Entergy Operations, Inc.

1340 Echelon Parkway Jackson, MS 39213-0298 Director, Nuclear Safety and Regulatory Affairs Entergy Operations, Inc.

P.O. Box 756 Port Gibson, MS 39150

<-, i i 7 /[,.<

Meeting Attendance List Date:

Grand Gulf Annual Assessment Meeting Reactor Oversight Program - CY 2004 Nuclear Regulatory Commission -Region IV Port Gibson, MS May 12,2005 Agenda Inhoduction Review of Reactor Oversight Process National Summary of Plant Performance Discussion of Plant Performance Results Licensee Response and Remarks NRC Closing Remarks Break NRC available to address public questions Region IV Organization Purpose of Todays Meeting A public forum for discussion of Grand Gulf licensee performance m NRC will address the licensee performance issues identified in the annual assessment letter Licensee will respond to the information in the letter and inform the NRC of new or existing programs to maintain or improve their petfomce I

NRC Representatives Geoff Miller, Senior Resident Inspector

- (601) 437-4620 Andy Barrett, Resident Inspector

  • (601) 437-4620 Bill lohnson, Branch Chief

- (817)860-8148 NRC Performance Goals 0 Safety: Ensure protection of the public health and Security: Ensure the secure use and management oi Openness: Ensure openness in our regulatory process Effectiveness: Ensure that NRC actions are effective, 0 Management: Ensure excellence in agency safety and the environment radioactive materials efficient. realistic, and timely management to cany out the NRC strategic objective 1

I Reactor Oversight Process I

Simiibnce Threshold Performance Indicators Green:

Only Baseline inspection White:

May increase NRC oversight Yellow:

Requires more NRC oversight Red Requires more NRC oversight Inswction Findins Green:

Very Low safety issue White:

Yellow:

Substantial safety issue Red High safety issue Low to moderate safety issue National Summary of Plant Performance SIrNr hl End of CY Z w 4 Licensee Response 78 Regulatory Response 21 Degraded Cornerstone 0

MuItiplwRepetitive Degmded Cornerstone 3

Unacceptable 0

Total 102'

'Davis-Besse is in IMC0350 process Examples of Baseline Inspections Equipment Alignment

-92 h d y r Triennial Fire Protection operator Response

-125 hrs/yr Emergency Preparedness

-80 hrdy Rad Release Controls

-100 hrs every 2 yrs Worker Radiation Protection -100 Myr Corrective Action Program

-200 hrs every 2 yrs Corrective Action Case Reviews -60 Ius@

- Engineering Team Inspection -500 hrs every 2 yr!

-200 hrs every 3 yrs Action Matrix Concept Increasing Safety Significance Increasing NRC Inspection Effo~is Increasiog NRCnIcensee Management Involvement Increasing Regulatory Actions National Summary Performance Indicator Results (at end of CY 2004)

  • Green I834

,White 6

  • Yellow 0

F Red 0

Total Inspection Findings (CY 2004) b Green 778 White I 1

  • Yellow 0

t Red 0

2

Grand Gulf Inspection Activities I

I Grand Gulf Inspection Activities I

(Ian I -Dec31,2W4)

Resident Inspectors Expended Approximately ZOO0 Hours Inspecting Grand Gulf in 2M)4 0 Region Based Inspectors Expended Approximately 1100 Hours Inspecting Grand Gulf in 2M14 I

Grand Gulf Assessment Results (Jan 1 - Dec 31,2004) 0 Licensee Response Column of b e NRC Action Matrix 0 No Greater Than Green Inspection Findings 0 No Greater Than Green Performance Indicators 1

I Licensee Response and Remarks George Williams Vice President. Nuclear Operations Entergy Operations. Inc.

I (Ian I -DK 31.2W4)

Grand Gulf Completed a Scheduled Refueling Outage in 2M14 Safety System Design and Performance Capability Team Inspection Conducted at Grand Gulf in 2004 Grand Gulf Annual Assessment Summary January 1 -December 31.2004 Entergy Operations, Inc. operated Grand Gulf in a manner that preserved public health and safety 0 All cornerstone objectives were met NRC plans to conduct baseline inspections at Grand Gulf through September 30,2006 Contacting the NRC 0 Report an emergency m Report a safety concern:

t (301) 816-5100 (call collect)

(800) 695-7403 Allegation@Nc.gov w General information or questions www.Nc.eo" Select'What We Do" for Public Affairs 3

Reference Sources Reactor Oversight Process h l ~ J i w w w. ~. g o v l N O V ~ S l G ~ i A S S E S S l l e Public Electronic ReadinP: Room

  • hrtp.Nwww.m.gov/mding.mhunl Public Document Room 1-800-3974209 (Toll h e )

4

T 6 s a

9 2

b '

0 L) m m

a c

m Y

Entergy Operations, Inc.

Electronic distribution by RIV:

Regional Administrator (BSMI)

DRP Director (ATH)

DRS Director (DDC)

DRS Deputy Director (KSW)

Senior Resident Inspector (GBM)

Branch Chief, DRPlA (WDJ)

Senior Project Engineer, DRPlA (TRF)

Team Leader, DRPiTSS (RLNI)

RlTS Coordinator (KEG)

RidsNrrDipmlipb Initials: L.vh "3-SlSP Review Completed: mc ADAMS: &Yes dd Publicly Available 0 Non-Publicly Available 0 Sensitive

@" Non-Sensitive No S \\DRP\\DRPDIR\\EOC 04\\GG5-12-05MS EOC wpd

1) SRIV:C:DRP/A I I

I I