Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 1 of 48 4/15/05 Table 3.4.2-1 Steam and Power Conversion System - Condensate and Condenser System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Atmosphere/
Weather (Ext)
Loss of Material One-Time Inspection Program VIII.E.5-c 3.4.1-11
- 418, 420, B System Monitoring Program VIII.E.5-c 3.4.1-11
- 418, 420, A Treated Water (Int)
Loss of Material Water Chemistry Program VIII.E.5-a 3.4.1-02 411, A One-Time Inspection Program VIII.E.5-a 3.4.1-02 411, B CST Heater Shell Fluid Pressure Boundary Carbon Steel Steam (Int)
Loss of Material Water Chemistry Program VIII.A.2-b 3.4.1-02 413, C One-Time Inspection Program VIII.A.2-b 3.4.1-02 413, D CST Heater Tubes Fluid Pressure Boundary Carbon Steel Steam (Ext)
Loss of Material Water Chemistry Program VIII.A.2-b 3.4.1-02 413, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 2 of 48 4/15/05 Table 3.4.2-1 Steam and Power Conversion System - Condensate and Condenser System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes One-Time Inspection Program VIII.A.2-b 3.4.1-02 413, D Loss of Material -
Fretting One-Time Inspection Program VIII.A.2-b 3.4.1-02 413, D Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.2-b 3.4.1-02
- 411, 413, D Water Chemistry Program VIII.E.2-b 3.4.1-02
- 411, 413, C Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Loss of Material Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Filters/Strainers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.2-b 3.4.1-02 411, D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 3 of 48 4/15/05 Table 3.4.2-1 Steam and Power Conversion System - Condensate and Condenser System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.E.2-b 3.4.1-02 411, C FW Heater Shell and Channel Head Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.2-b 3.4.1-02
- 411, 413, D Water Chemistry Program VIII.E.2-b 3.4.1-02
- 411, 413, C Heat Exchangers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material One-Time Inspection Program VIII.A.1-b 3.4.1-02 D
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.4-a 3.4.1-02 A
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H1-b 3.4.1-05 A
Soil (Ext)
Loss of Material Buried Services Corrosion Monitoring Program VIII.G1-e 3.4.1-12 408, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 4 of 48 4/15/05 Table 3.4.2-1 Steam and Power Conversion System - Condensate and Condenser System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Pipe & Fittings Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.E.1-a 3.4.1-06 423, A One-Time Inspection Program VIII.E.1-b 3.4.1-02 411, B Water Chemistry Program VIII.E.1-b 3.4.1-02 411, A Stainless Steel Soil (Ext)
Loss of Material Buried Services Corrosion Monitoring Program 407, F VIII.E-22 4-11 A, 4002 Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 405, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 405, 419, C Pumps Fluid Pressure Boundary Cast Iron Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 422, A Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.3-a 3.4.1-02
- 411, 422, B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 5 of 48 4/15/05 Table 3.4.2-1 Steam and Power Conversion System - Condensate and Condenser System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.E.3-a 3.4.1-02
- 411, 422, A Loss of Material -
Selective Leaching One-Time Inspection Program
- 412, 422, F VIII.E-18 4-16 C
Valves &
Dampers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material Water Chemistry Program VIII.E.2-b 3.4.1-02 411, A One-Time Inspection Program VIII.E.2-b 3.4.1-02 411, B Flow Accelerated Corrosion Program VIII.E.2-a 3.4.1-06 423, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 6 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 7 of 48 4/15/05 Table 3.4.2-2 Steam and Power Conversion System - Demineralized Makeup Water System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program VII.H2.3-a 3.3.1-05 416, E Atmosphere/
Weather (Ext)
Loss of Material One-Time Inspection Program VIII.G.4-c 3.4.1-11
- 417, 418, 420, D System Monitoring Program VIII.G.4-c 3.4.1-11
- 417, 418, 420, C Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material Water Chemistry Program VIII.G.4-a 3.4.1-02
- 411, 417, C One-Time Inspection Program VIII.G.4-a 3.4.1-02
- 411, 417, D Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 8 of 48 4/15/05 Table 3.4.2-2 Steam and Power Conversion System - Demineralized Makeup Water System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Loss of Material Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Filters Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02 417, E Heat Exchangers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material One-Time Inspection Program VIII.C.1-a 3.4.1-02 E
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.1-b 3.4.1-02 E
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.1-b 3.4.1-02
- 411, 417, D Water Chemistry Program VIII.E.1-b 3.4.1-02
- 411, 417, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 9 of 48 4/15/05 Table 3.4.2-2 Steam and Power Conversion System - Demineralized Makeup Water System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Stainless Steel Soil (Ext)
Loss of Material Buried Services Corrosion Monitoring Program 407, F VIII.G-22 4-22 E, 6 Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 417, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 417, 419, C Pumps Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02 417, E Transmitter/
Element Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 417, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 417, 419, C Valves &
Dampers Fluid Pressure Boundary Cast Austenitic SS Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 417, 419, D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 10 of 48 4/15/05 Table 3.4.2-2 Steam and Power Conversion System - Demineralized Makeup Water System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.E.5-b 3.4.1-02
- 417, 419, C Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 417, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 417, 419, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 11 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 12 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Air/Gas (Int)
Loss of Material One-Time Inspection Program VII.H2.3-a 3.3.1-05 409, E Oil (Int)
Loss of Material One-Time Inspection Program VIII.G.5-d 3.3.1-06 C
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Filters/Strainers Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VIII.G.5-d 3.3.1-06 C
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.1-c 3.4.1-02
- 408, 411, D Water Chemistry Program VIII.D1.1-c 3.4.1-02
- 408, 411, C Heat Exchangers Fluid Pressure Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-b 3.3.1-06 C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 13 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Boundary Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Raw Water (Int)
Loss of Material One-Time Inspection Program VIII.G.5-b 3.4.1-03
- 411, 421, E Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.1-c 3.4.1-02
- 408, 411, D Water Chemistry Program VIII.D1.1-c 3.4.1-02
- 408, 411, C Indicators/
Recorders Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.1-c 3.4.1-02
- 408, 411, D Water Chemistry Program VIII.D1.1-c 3.4.1-02
- 408, 411, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 14 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext Containment Air (Ext))
Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Pipe & Fittings Flow Restriction Carbon Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.1-c 3.4.1-02 411, B VIII.D1.3-a 3.4.1-02 411, B VIII.G.1-c 3.4.1-02 411, B VIII.G.2-a 3.4.1-02 411, B Water Chemistry Program VIII.D1.1-c 3.4.1-02 411, A VIII.D1.3-a 3.4.1-02 411, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 15 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes VIII.G.1-c 3.4.1-02 411, A VIII.G.2-a 3.4.1-02 411, A Fluid Pressure Boundary Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
System Monitoring Program VIII.H.1-b 3.4.1-05 A
Oil (Int)
Loss of Material One-Time Inspection Program VIII.G.5-d C
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.D1.1-a 3.4.1-06 A
VIII.D1.3-b 3.4.1-06 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 16 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes VIII.G.1-a 3.4.1-06 A
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.1-c 3.4.1-02 411, B VIII.D1.3-a 3.4.1-02 411, B VIII.G.1-c 3.4.1-02 411, B VIII.G.2-a 3.4.1-02 411, B Water Chemistry Program VIII.D1.1-c 3.4.1-02 411, A VIII.D1.3-a 3.4.1-02 411, A VIII.G.1-c 3.4.1-02 411, A VIII.G.2-a 3.4.1-02 411, A Stainless Steel Air (Int)
Loss of Material One-Time Inspection Program 409, J VIII.I-11 4-32 B, 4001
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 17 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Atmosphere/
Weather (Ext)
Loss of Material System Monitoring Program G
VIII.F1-5 3-23 A
Oil (Int)
Loss of Material One-Time Inspection Program F
VIII.A-2 4-12 B
Soil (Ext)
Loss of Material Buried Services Corrosion Monitoring Program 407, F VIII.E-21 4-22 E, 4006 Treated Water (Int)
Cracking Water Chemistry Program 410, F VIII.F-5 4-8 A
One-Time Inspection Program 410, F VIII.F-5 4-8 B
Pipe & Fittings Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 405, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 405, 419, C Pumps Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VIII.G.5-d 3.3.1-06 C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 18 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.D1.3-b 3.4.1-06 A
One-Time Inspection Program VIII.D1.3-a 3.4.1-02 411, B VIII.G.2-a 3.4.1-02 411, B Water Chemistry Program VIII.D1.3-a 3.4.1-02 411, A VIII.G.2-a 3.4.1-02 411, A Stainless Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 405, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 405, 419, C Traps (Steam)
Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 409, J VIII.I-15 4-33 D, 4001
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 19 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Turbines Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 409, J VIII.I-15 4-33 D, 4001 Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Valves &
Dampers Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 409, G VIII.I-15 4-33 D, 4001 Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Raw Water (Int)
Loss of Material One-Time Inspection Program VIII.G.1-d 3.4.1-03
- 411, 421, D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 20 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Steam (Int)
Loss of Material Water Chemistry Program VIII.A.2-b 3.4.1-02 A
One-Time Inspection Program VIII.A.2-b 3.4.1-02 411, B Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.D1.2-a 3.4.1-06 A
One-Time Inspection Program VIII.D1.2-b 3.4.1-02 411, B VIII.G.3-a 3.4.1-02 411, B Water Chemistry Program VIII.D1.2-b 3.4.1-02 411, A VIII.G.3-a 3.4.1-02 411, A Valves &
Dampers Fluid Pressure Boundary Cast Austenitic SS Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 405, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 405, 419, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 21 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Cast Iron Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 422, A Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.G.3-a 3.4.1-02
- 411, 422, B Water Chemistry Program VIII.G.3-a 3.4.1-02
- 411, 422, A Loss of Material -
Selective Leaching One-Time Inspection Program
- 412, 422, F VIII.E-18 4-16 D
Stainless Steel Air (Int)
Loss of Material One-Time Inspection Program 409, F VIII.I-11 4-32 D, 4001 Steam (Int)
Cracking Water Chemistry Program 404, F VIII.B1-2 4-20 A
One-Time Inspection Program 404, F VIII.B1-2 4-20 B
Loss of Material Water Chemistry Program 404, F VIII.B1-3 4-29 A
One-Time Inspection Program 404, F VIII.B1-3 4-29 B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 22 of 48 4/15/05 Table 3.4.2-3 Steam and Power Conversion System - Feedwater System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Valves &
Dampers Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Cracking Water Chemistry Program F
VIII.D1-5 4-8 A
One-Time Inspection Program F
VIII.D1-5 4-8 B
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 405, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 405, 419, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 23 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 24 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 25 of 48 4/15/05 Table 3.4.2-4 Steam and Power Conversion System - Heater Extraction and Drain System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-08 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.1-a 3.4.1-02 E
Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Heat Exchangers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-08 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.1-a 3.4.1-02 E
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.C.1-a 3.4.1-06 423, A Water Chemistry Program VIII.C.1-b 3.4.1-02 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 26 of 48 4/15/05 Table 3.4.2-4 Steam and Power Conversion System - Heater Extraction and Drain System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes One-Time Inspection Program VIII.C.1-b 3.4.1-02 411, B Pipe & Fittings Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.E.1-a 3.4.1-06
- 414, 423, C One-Time Inspection Program VIII.E.1-b 3.4.1-02
- 411, 414, D Water Chemistry Program VIII.E.1-b 3.4.1-02
- 411, 414, C Stainless Steel Steam (Int)
Cracking Water Chemistry Program 404, F VIII.B1-2 4-20 A
One-Time Inspection Program 404, F VIII.B1-2 4-20 B
Loss of Material Water Chemistry Program 404, F VIII.B1-3 4-29 A
One-Time Inspection Program 404, F VIII.B1-3 4-29 B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 27 of 48 4/15/05 Table 3.4.2-4 Steam and Power Conversion System - Heater Extraction and Drain System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Pumps Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.3-a 3.4.1-02
- 411, 414, D Water Chemistry Program VIII.E.3-a 3.4.1-02
- 411, 414, C Transmitter/
Element Fluid Pressure Boundary Stainless Steel Treated Water (Int)
Cracking Water Chemistry Program 410, F VIII.F-18 4-8 C
One-Time Inspection Program 410, F VIII.F-18 4-8 D
Loss of Material Water Chemistry Program F
VIII.F-17 4-10 C
One-Time Inspection Program F
VIII.F-17 4-10 D
Traps (Steam)
Fluid Pressure Boundary Carbon Steel Steam (Int)
Loss of Material Water Chemistry Program VIII.C.2-b 3.4.1-02 C
One-Time Inspection Program VIII.C.2-b 3.4.1-02 D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 28 of 48 4/15/05 Table 3.4.2-4 Steam and Power Conversion System - Heater Extraction and Drain System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Valves &
Dampers Fluid Pressure Boundary Carbon Steel Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.C.2-a 3.4.1-06 423, A Water Chemistry Program VIII.C.2-b 3.4.1-02 A
One-Time Inspection Program VIII.C.2-b 3.4.1-02 B
Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.E.2-a 3.4.1-06
- 414, 423, C One-Time Inspection Program VIII.E.2-b 3.4.1-02
- 411, 414, D Water Chemistry Program VIII.E.2-b 3.4.1-02
- 411, 414, C Fluid Pressure Boundary Cast Iron Plant Indoor Air (Ext)
Loss of Material None Required VIII.H.1-b 3.4.1-05
- 401, 422, I VIII.I-15 4-33 A, 4001 Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.C.2-a 3.4.1-06
- 422, 423, A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 29 of 48 4/15/05 Table 3.4.2-4 Steam and Power Conversion System - Heater Extraction and Drain System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.C.2-b 3.4.1-02 422, A One-Time Inspection Program VIII.C.2-b 3.4.1-02 422, B Loss of Material -
Selective Leaching One-Time Inspection Program
- 412, 422, F VIII.F-14 4-16 A
Valves &
Dampers Fluid Pressure Boundary Stainless Steel Steam (Int)
Cracking Water Chemistry Program 404, F VIII.B1-2 4-20 A
One-Time Inspection Program 404, F VIII.B1-2 4-20 B, 4001 Loss of Material Water Chemistry Program 404, F VIII.B1-3 4-29 C
One-Time Inspection Program 404, F VIII.B1-3 4-29 D, 1
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 30 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 31 of 48 4/15/05 Table 3.4.2-5 Steam and Power Conversion System - Main Air Ejection and Gland Seal System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Blowers Fans Compressor Vacuum Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 415, J VIII.I-15 4-33 C, 4001 Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material Water Chemistry Program VIII.A.1-b 3.4.1-02 415, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 415, D Cast Iron Steam (Int)
Loss of Material Water Chemistry Program VIII.A.1-b 3.4.1-02
- 415, 422, C One-Time Inspection Program VIII.A.1-b 3.4.1-02
- 415, 422, D Loss of Material -
Selective Leaching One-Time Inspection Program
- 412, 415, J VIII.F-14 4-16 D
Filters/Strainers Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 415, J VIII.I-15 4-33 C, 4001
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 32 of 48 4/15/05 Table 3.4.2-5 Steam and Power Conversion System - Main Air Ejection and Gland Seal System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.1-a 3.4.1-06 415, C Water Chemistry Program VIII.A.1-b 3.4.1-02 415, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 415, D Heat Exchangers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material Water Chemistry Program VIII.A.1-b 3.4.1-02 415, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 415, D Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.2-b 3.4.1-02
- 411, 415, D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 33 of 48 4/15/05 Table 3.4.2-5 Steam and Power Conversion System - Main Air Ejection and Gland Seal System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Pipe & Fittings Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 416, G VIII.I-15 4-33 A, 4001 Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material Water Chemistry Program VIII.A.1-b 3.4.1-02 415, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 415, D Traps (Steam)
Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Raw Water (Int)
Loss of Material One-Time Inspection Program VII.C1.2-a 3.3.1-17 E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 34 of 48 4/15/05 Table 3.4.2-5 Steam and Power Conversion System - Main Air Ejection and Gland Seal System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Steam (Int)
Loss of Material Water Chemistry Program VIII.A.2-b 3.4.1-02 415, C One-Time Inspection Program VIII.A.2-b 3.4.1-02 415, D Valves &
Dampers Fluid Pressure Boundary Carbon Steel Air (Int)
Loss of Material One-Time Inspection Program 416, G VIII.I-15 4-33 C, 1 Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.2-a 3.4.1-06 415, C One-Time Inspection Program VIII.A.2-b 3.4.1-02 415, D Water Chemistry Program VIII.A.2-b 3.4.1-02 415, C Valves &
Dampers Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.D1.2-b 3.4.1-02
- 411, 415, D
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 35 of 48 4/15/05 Table 3.4.2-5 Steam and Power Conversion System - Main Air Ejection and Gland Seal System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.D1.2-b 3.4.1-02
- 411, 415, C Cast Iron Steam (Int)
Loss of Material Water Chemistry Program VIII.A.2-b 3.4.1-02
- 415, 422, C One-Time Inspection Program VIII.A.2-b 3.4.1-02
- 411, 415, 422, D Loss of Material -
Selective Leaching One-Time Inspection Program
- 412, 422, F VIII.F-14 4-16 B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 36 of 48 4/15/05
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 37 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 C
Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.1-a 3.4.1-06
- 403, 423, C Water Chemistry Program VIII.A.1-b 3.4.1-02 403, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 403, D Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.F.1-b 3.4.1-02 E
Filters/Strainers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 401, A Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.2-a 3.4.1-06
- 403, 423, C Water Chemistry Program VIII.A.2-b 3.4.1-02 403, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 38 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes One-Time Inspection Program VIII.A.2-b 3.4.1-02 403, D Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E5-a 3.4.1-02 E
Indicators/
Recorders Fluid Pressure Boundary Stainless Steel Steam (Int)
Cracking Water Chemistry Program
- 403, 404, J VIII.B1-2 4-20 C
Loss of Material Water Chemistry Program
- 403, 404, J VIII.B1-3 4-29 C
Ejectors Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 401, A Steam (Int)
Loss of Material Water Chemistry Program VIII.A.1-b 3.4.1-02 403, C One-Time Inspection Program VIII.A.1-b 3.4.1-02 403, D Fasteners Fluid Pressure Boundary Carbon Steel Containment Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 39 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 401, A Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Heat Exchangers Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Steam (Int)
Loss of Material One-Time Inspection Program VIII.B1.1-a 3.4.1-07 E
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.F.1-b 3.4.1-02 E
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 40 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.1-a 3.4.1-06 423, A VIII.B1.1-c 3.4.1-06 423, A Water Chemistry Program VIII.A.1-b 3.4.1-02 424, A VIII.B1.1-a 3.4.1-07 424, A One-Time Inspection Program VIII.A.1-b 3.4.1-02 B
Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.F.1-a 3.4.1-06 423, A One-Time Inspection Program VIII.F.1-b 3.4.1-02 411, B Water Chemistry Program VIII.F.1-b 3.4.1-02 411, A Copper Alloys Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program 402, F VII.J-7 3-81 A, 4001 Stainless Steel Steam (Int)
Cracking Water Chemistry Program 404, G VIII.B1-2 4-20 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 41 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Steam (Int)
Loss of Material Water Chemistry Program 404, G VIII.B1-3 4-29 A
Pumps Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-13 A
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-a 3.4.1-02 E
Traps (Steam)
Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.2-a 3.4.1-06
- 403, 423, C Water Chemistry Program VIII.A.2-b 3.4.1-02 403, C One-Time Inspection Program VIII.A.2-b 3.4.1-02 403, D Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.F.1-b 3.4.1-02 E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 42 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Valves &
Dampers Fluid Pressure Boundary Carbon Steel Containment Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Plant Indoor Air (Ext)
Loss of Material Boric Acid Corrosion Program VIII.H.1-a 3.4.1-13 A
Steam (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.A.2-a 3.4.1-06 423, A VIII.B1.2-b 3.4.1-06 423, A Water Chemistry Program VIII.A.2-b 3.4.1-02 424, A VIII.B1.2-a 3.4.1-07 424, A One-Time Inspection Program VIII.A.2-b 3.4.1-02 B
Valves &
Dampers Fluid Pressure Boundary Carbon Steel Treated Water (Int)
Loss of Material Flow Accelerated Corrosion Program VIII.F.2-a 3.4.1-06 423, A One-Time Inspection Program VIII.F.2-b 3.4.1-02 411, B
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 43 of 48 4/15/05 Table 3.4.2-6 Steam and Power Conversion System - Main Steam System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Water Chemistry Program VIII.F.2-b 3.4.1-02 411, A Stainless Steel Steam (Int)
Cracking Water Chemistry Program 404, F VIII.B1-2 4-20 C
Loss of Material Water Chemistry Program 404, F VIII.B1-3 4-29 C
Treated Water (Int)
Loss of Material One-Time Inspection Program VIII.E.5-b 3.4.1-02
- 417, 419, D Water Chemistry Program VIII.E.5-b 3.4.1-02
- 417, 419, C
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 1 of 48 4/15/05 Table 3.4.2-7 Steam and Power Conversion System - Turbine Generator System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Accumulators Fluid Pressure Boundary Carbon Steel Air/Gas (Int)
Loss of Material One-Time Inspection Program VII.H.2.3-a 3.3.1-05 E
Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-a 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Stainless Steel Oil (Int)
Loss of Material One-Time Inspection Program G
VIII.A-2 4-12 D
Fasteners Fluid Pressure Boundary Carbon Steel Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Loss of Preload Bolting Integrity Program VIII.H.2-a 3.4.1-08 406, C Filters/Strainers Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-a 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 2 of 48 4/15/05 Table 3.4.2-7 Steam and Power Conversion System - Turbine Generator System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Heat Exchangers Fluid Pressure Boundary Carbon Steel Air/Gas (Int)
Loss of Material One-Time Inspection Program VII.H.2.3-a 3.3.1-05 E
Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-a 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Raw Water (Int)
Loss of Material One-Time Inspection Program VII.C1.3-a 3.3.1-17 E
Pipe & Fittings Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-b 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Raw Water (Int)
Loss of Material One-Time Inspection Program VII.C1.1-a 3.3.1-17 E
Steam (Int)
Loss of Material One-Time Inspection Program VIII.B1.1-c 3.3.1-17 E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 3 of 48 4/15/05 Table 3.4.2-7 Steam and Power Conversion System - Turbine Generator System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Treated Water (Int)
Loss of Material One-Time Inspection Program VII.C2.1-a 3.3.1-17 E
Stainless Steel Oil (Int)
Loss of Material One-Time Inspection Program G
VIII.A-2 4-12 B
Pumps Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-a 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Cast Iron Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-a 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Valves &
Dampers Fluid Pressure Boundary Carbon Steel Oil (Int)
Loss of Material One-Time Inspection Program VII.G.7-b 3.3.1-06 E
Plant Indoor Air (Ext)
Loss of Material System Monitoring Program VIII.H.1-b 3.4.1-05 A
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 4 of 48 4/15/05 Table 3.4.2-7 Steam and Power Conversion System - Turbine Generator System - Summary of Aging Management Evaluation Component Type Intended Function Material Environment Aging Effect Requiring Management Aging Management Programs NUREG -
1801 Volume 2 Line Item Table 1 Item Notes Rev 1 NUREG -
1801 Volume 2 Line Item Rev 1 NUREG -
1801 Volume 1 Table Row (Table # -
Row #)
Rev 1 NUREG
- 1801 Notes Raw Water (Int)
Loss of Material One-Time Inspection Program VII.C1.2-a 3.3.1-17 E
Steam (Int)
Loss of Material One-Time Inspection Program VIII.B1.2-b 3.3.1-17 E
Treated Water (Int)
Loss of Material One-Time Inspection Program VII.C2.2-a 3.3.1-17 E
Application for Renewed Operating License - Palisades Nuclear Plant Precedent Tables for Section 3.4, Steam and Power Conversion System 5 of 48 4/15/05 Note 4001: This material and environment combination is shown in GALL as not having the specified AERM. For the purpose of precedent review, Palisades considered Notes A, B, C, or D to apply to those instances where we are managing items which GALL does not indicate need to be managed.
Note 4006: SOIL may be the environment for components buried in soil (below grade), and also the environment for components submerged in groundwater and damp soil. The aging effect of potential exposure to raw water is also evaluated.