ML051100301

From kanterella
Jump to navigation Jump to search

4/18/05 Diablo Canyon Pp, Units 1 and 2 - Closeout Letter for GL 2004-01, Requirements for Steam Generator Tube Inspection
ML051100301
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 04/18/2005
From: Shukla G
NRC/NRR/DLPM/LPD4
To: Rueger G
Pacific Gas & Electric Co
SHUKLA G , NRR/DLPM/PD4, 415-8420
References
GL-04-001, TAC MC4817, TAC MC4818
Download: ML051100301 (3)


Text

April 18, 2005 Mr. Gregory M. Rueger Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P. O. Box 3 Avila Beach, CA 93424

SUBJECT:

DIABLO CANYON POWER PLANT, UNIT NOS. 1 AND 2 - CLOSEOUT LETTER FOR GL 2004-01, "REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS" (TAC NOS. MC4817 AND MC4818)

Dear Mr. Rueger:

On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, "Requirements for Steam Generator Tube Inspections." The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees' steam generator (SG) tube inspection programs comply with the existing tube inspection requirements in the plant Technical Specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50.

By letter dated October 27, 2004, Pacific Gas and Electric Company provided a response to GL 2004-01 for Diablo Canyon Power Plant, Units 1 and 2. The staffs review of your response to the GL 2004-01 did not identify any concerns with the inspection practices employed at Diablo Canyon Power Plant, Units 1 and 2. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

If you have any questions regarding this matter, please contact me at (301) 415-8439.

Sincerely,

/RA/

Girija S. Shukla, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323 cc: See next page

April 18, 2005 Mr. Gregory M. Rueger Senior Vice President, Generation and Chief Nuclear Officer Pacific Gas and Electric Company Diablo Canyon Power Plant P. O. Box 3 Avila Beach, CA 93424

SUBJECT:

DIABLO CANYON POWER PLANT, UNIT NOS. 1 AND 2 - CLOSEOUT LETTER FOR GL 2004-01, "REQUIREMENTS FOR STEAM GENERATOR TUBE INSPECTIONS" (TAC NOS. MC4817 AND MC4818)

Dear Mr. Rueger:

On August 30, 2004, the Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2004-01, "Requirements for Steam Generator Tube Inspections." The purpose of GL 2004-01 was to obtain information that would enable the NRC staff to determine whether licensees' steam generator (SG) tube inspection programs comply with the existing tube inspection requirements in the plant Technical Specifications in conjunction with Appendix B to Title 10 of the Code of Federal Regulations Part 50.

By letter dated October 27, 2004, Pacific Gas and Electric Company provided a response to GL 2004-01 for Diablo Canyon Power Plant, Units 1 and 2. The staffs review of your response to the GL 2004-01 did not identify any concerns with the inspection practices employed at Diablo Canyon Power Plant, Units 1 and 2. The staff, therefore, concludes that your SG tube inspection practices are in compliance with the existing tube inspection requirements.

If you have any questions regarding this matter, please contact me at (301) 415-8439.

Sincerely,

/RA/

Girija S. Shukla, Project Manager, Section 2 Project Directorate IV Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-275 and 50-323 DISTRIBUTION:

PUBLIC PDIV-2 Reading RidsNrrDlpmPdiv (HBerkow)

RidsOgcRp RidsNrrPMGShukla RidsNrrLALFeizollahi RidsNrrDlpmPdiv2 (RGramm)

RidsAcrsAcnwMailCenter cc: See next page RidsRegion4MailCenter (BJones)

PKlein JTerrell MYoder LLund ACCESSION NO.: ML051100301 NRR-106 OFFICE PDIV-2/PM PDIV-2/LA PDIV-2/SC NAME GShukla LFeizollahi RGramm DATE 4/18/05 4/14/05 4/18/05 DOCUMENT NAME: E:\\Filenet\\ML051100301.wpd OFFICIAL RECORD COPY

March 2005 Diablo Canyon Power Plant, Units 1 and 2 cc:

NRC Resident Inspector Diablo Canyon Power Plant c/o U.S. Nuclear Regulatory Commission P.O. Box 369 Avila Beach, CA 93424 Sierra Club San Lucia Chapter c/o Henriette Groot 1000 Montecito Road Cayucos, CA 93430 Ms. Nancy Culver San Luis Obispo Mothers for Peace P.O. Box 164 Pismo Beach, CA 93448 Chairman San Luis Obispo County Board of Supervisors Room 370 County Government Center San Luis Obispo, CA 93408 Mr. Truman Burns Mr. Robert Kinosian California Public Utilities Commission 505 Van Ness, Room 4102 San Francisco, CA 94102 Diablo Canyon Independent Safety Committee ATTN: Robert R. Wellington, Esq.

Legal Counsel 857 Cass Street, Suite D Monterey, CA 93940 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower & Pavillion 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 Richard F. Locke, Esq.

Pacific Gas & Electric Company P.O. Box 7442 San Francisco, CA 94120 Mr. David H. Oatley, Vice President and General Manager Diablo Canyon Power Plant P.O. Box 56 Avila Beach, CA 93424 City Editor The Tribune 3825 South Higuera Street P.O. Box 112 San Luis Obispo, CA 93406-0112 Mr. Ed Bailey, Chief Radiologic Health Branch State Department of Health Services P.O. Box 997414 (MS 7610)

Sacramento, CA 95899-7414 Mr. James D. Boyd, Commissioner California Energy Commission 1516 Ninth Street (MS 31)

Sacramento, CA 95814 Mr. James R. Becker, Vice President Diablo Canyon Operations and Station Director Diablo Canyon Power Plant P.O. Box 3 Avila Beach, CA 93424 Jennifer Tang Field Representative United States Senator Barbara Boxer 1700 Montgomery Street, Suite 240 San Francisco, CA 94111