ML051080454
| ML051080454 | |
| Person / Time | |
|---|---|
| Site: | Peach Bottom |
| Issue date: | 05/05/2005 |
| From: | George Wunder NRC/NRR/DLPM/LPD1 |
| To: | Crane C Exelon Generation Co, Exelon Nuclear |
| Wunder G, NRR/DLPM, 415-1494 | |
| References | |
| TAC MC2219, TAC MC2220 | |
| Download: ML051080454 (4) | |
Text
May 5, 2005 Mr. Christopher M. Crane President and Chief Nuclear Officer Exelon Nuclear Exelon Generation Company, LLC Kennett Square, PA 19348
SUBJECT:
PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3 -
CLARIFICATION OF SAFETY EVALUATION RE: ACTIVATION OF OSCILLATION POWER RANGE MONITOR TRIP (TAC NOS. MC2219 AND MC2220)
Dear Mr. Crane:
On March 21, 2005, we issued Amendments Nos. 251 and 254 to the renewed operating licenses of the Peach Bottom Atomic Power Station, Units 2 and 3, respectively. These amendments changed the Technical Specifications to allow for activation of the oscillation power range monitor (OPRM) trip function. In section 4.1 of the safety evaluation supporting these amendments we describe the OPRM logic. We understand that our description could be read in such a way as to imply that there is an OPRM inoperable trip function separate from the average power range monitor (APRM) inoperable trip function. We understand that this is not the case; however, a failure in the OPRM can result in either an APRM trip signal or an alarm, depending on the nature of the failure.
I discussed this issue with Mr. Glenn Stewart of your staff in a call on April 18, 2005. If you have any questions I can be reached at (301) 415-1494.
Sincerely,
/RA/
George F. Wunder, Project Manager, Section 2 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket Nos. 50-277 and 50-278 cc: See next page
ML051080454 OFFICE PM/PD1-2 LA/PD1-2 SC/PD1-2 NAME GWunder MOBrien DRoberts DATE 5/3/05 5/2/05 5/5/05
Peach Bottom Atomic Power Station, Unit Nos. 2 and 3 cc:
Site Vice President Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Plant Manager Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Regulatory Assurance Manager Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Resident Inspector U.S. Nuclear Regulatory Commission Peach Bottom Atomic Power Station P.O. Box 399 Delta, PA 17314 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Roland Fletcher Department of Environment Radiological Health Program 2400 Broening Highway Baltimore, MD 21224 Correspondence Control Desk Exelon Generation Company, LLC P. O. Box 160 Kennett Square, PA 19348 Rich Janati, Chief Division of Nuclear Safety Bureau of Radiation Protection Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Board of Supervisors Peach Bottom Township 545 Broad Street Ext.
Delta, PA 17314-9203 Mr. Richard McLean Power Plant and Environmental Review Division Department of Natural Resources B-3, Tawes State Office Building Annapolis, MD 21401 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 Manager-Financial Control & Co-Owner Affairs Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, NJ 08038-0236 Manager Licensing-Peach Bottom Atomic Power Station Exelon Generation Company, LLC 200 Exelon Way, KSA -3E Kennett Square, PA 19348
Peach Bottom Atomic Power Station, Unit Nos. 2 and 3 cc:
Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President-Operations Mid-Atlantic Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Senior Vice President, Nuclear Services Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director-Licensing and Regulatory Affairs Exelon Generation Company, LLC 200 Exelon Way, KSA 3-E Kennett Square, PA 19348