Reporting Requirements 5.6 5.6 Reporting Requirements 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.
5.6.1 Not Used 5.6.2 Annual Radiological Environmental Operating Report
- NOTE -
A single submittal may be made for a multiple unit station. The submittal should combine sections common to all units at the station.
The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 15 of each year. The report shall include summaries, interpretations, and analyses of trends of the results of the Radiological Environmental Monitoring Program for the reporting period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual (ODCM), and in 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.
A full listing of the information to be contained in the Annual Radiological Environmental Operating Report is provided in the ODCM.
INDIAN POINT 2 5.6 - 1 Amendment No. 242
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.3 Radioactive Effluent Release Report
-NOTE -
A single submittal may be made for a multiple unit station. The submittal shall combine sections common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
The Radioactive Effluent Release Report covering the operation of the unit in the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and Process Control Program and in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix I,Section IV.B.1.
5.6.4 Not Used 5.6.5 CORE OPERATING LIMITS REPORT (COLR)
- a.
Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
- 1.
Technical Specification 2.1, Safety Limits (SL);
- 2.
Technical Specification 3.1.1, SHUTDOWN MARGIN (SDM);
- 3.
Technical Specification 3.1.3, Moderator Temperature Coefficient (MTC);
- 4.
Technical Specification 3.1.5, Shutdown Bank Insertion Limits;
- 5.
Technical Specification 3.1.6, Control Bank Insertion Limits;
- 6.
Technical Specification 3.2.1, Heat Flux Hot Channel Factor (FQ(Z));
- 7.
Technical Specification 3.2.2, Nuclear En'thalpy Rise Hot Channel Factor; INDIAN POINT 2 5.6-2 Amendment No. 242
Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.
5.6.1 5.6.2 Not Used Annual Radiological Environmental Operating Report
NOTE-------------------------------
A single submittal may be made for a multiple unit station. The submittal should combine sections common to all units at the station.
The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 15 of each year. The report shall include summaries, interpretations, and analyses of trends of the results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined in the Offsite Dose Calculation Manual (ODCM), and in 10 CFR 50, Appendix I, Sections IV.B.2, IV.B.3, and IV.C.
(continued)
INDIAN POINT 3 5.0 - 32 Amendment 227
Reporting Requirements 5.6 5.6 Reporting Requirements 5.6.2 5.6.3 Annual Radiological Environmental Operating Report (continued)
A full listing of the information to be contained in the Annual Radiological Environmental Operating Report is provided in the ODCM.
Radioactive Effluent Release Report
NOTE------------------------------
A single submittal may be made for a multiple unit station. The submittal shall combine sections common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
The Radioactive Effluent Release Report covering the operation of the unit in the previous year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a.
The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODCM and Process Control Program and in conformance with 10 CFR Part 50.36a and 10 CFR 50, Appendix I,Section IV.B.1.
Not Used CORE OPERATING LIMITS REPORT (COLR) 5.6.4 5.6.5
- a. Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
(continued)
INDIAN POINT 3 5.0 - 33 Amendment 227