Text
T.S. 6.9.1.6 April 15, 2005 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Limerick Generating Station, Units 1 and 2 Facility Operating License Nos. NPF-39 and NPF-85 NRC Docket Nos. 50-352 and 50-353
Subject:
Monthly Operating Report for March 2005 Attached is the monthly operating report for Limerick Units 1 and 2 for the month of March 2005 forwarded pursuant to Technical Specification 6.9.1.6 and the guidance of NRC Generic Letter 97-02. The attached monthly operating report data has also been entered into the INPO Consolidated Database for the month of March 2005 for Units 1 and 2.
If you have any questions or require additional information, please do not hesitate to contact us.
Sincerely, Original signed by Bryan C. Hanson Plant Manager-LGS Exelon Generation Company, LLC Attachments cc:
S. Collins, Administrator, Region I, USNRC S. Hansell, LGS USNRC Senior Resident Inspector
Unit:
Limerick 1 Docket No:
50-352 Date:
4/15//05 Completed by: Greg Lee Telephone:
(610) 718-3707 A.
OPERATING DATA REPORT REPORTING PERIOD-March 2005 Design Electrical Rating (MWe-Net) 1191.00 Maximum Dependable Capacity (MWe-Net) 1134.00 Month Year to Date Cumulative Hours Reactor Critical (Hours) 744.00 2,109.13 149,064.77 Hours Generator On-Line (Hours) 744.00 2,082.42 147,009.00 Unit Reserve Shutdown Hours (Hours) 0.00 0.00 0.00 Net Electrical Energy (MWh) 873,377.00 2,420,626.00 153,785,971.00 B.
UNIT SHUTDOWN No.
Date (yymmdd)
Type Generator Off-line Duration (hrs)
Reason Method Corrective Actions/Comments None during the month of March 2005
SUMMARY
Unit 1 began the month of March 2005 at 100% of rated thermal power (RTP).
There were no power changes during the month of March 2005.
Unit 1 ended the month of March 2005 at 100% RTP.
Type Reason Method F-Forced A-Equipment Failure (Explain) 1-Manual S-Scheduled B-Maintenance or Test 2-Manual Trip/Scram C-Refueling 3-Automatic Trip/Scram D-Regulatory Restriction 4-Continuation E-Operator Training/License Examination 5-Other (Explain)
F-Administrative G-Operational Error (Explain)
H-Other (Explain)
C.
SAFETY/RELIEF VALVE OPERATION Date Valves Actuated No. & Type of Actuation Plant Condition Description of Event None During March 2005
Unit:
Limerick 2 Docket No:
50-353 Date:
4/15/05 Completed by: Greg Lee Telephone:
(610) 718-3707 A. OPERATING DATA REPORT REPORTING PERIOD-March 2005 Design Electrical Rating (MWe-Net) 1191.00 Maximum Dependable Capacity (MWe-Net) 1134.00 Month Year to Date Cumulative Hours Reactor Critical (Hours) 256.25 1,662.32 124,865.55 Hours Generator On-Line (Hours) 176.10 1,582.10 123,003.84 Unit Reserve Shutdown Hours (Hours) 0.00 0.00 0.00 Net Electrical Energy (MWh) 137,948.00 1,692,849.00 132,666,216.00 B. UNIT SHUTDOWN No.
Date (yymmdd)
Type Generator Off-line Duration (hrs)
Reason Method Corrective Actions/Comments 1
050301 S
420.42 C
4 2R08 refueling outage continuing 2
050320 S
147.48 B
1 2F33 turbine bearing repair
SUMMARY
Unit 2 began the month of March 2005 at 0% of rated thermal power (RTP).
On March 17th at 07:24 hours, reactor criticality was achieved.
On March 18th at 05:27 hours, the main generator was synchronized to the grid at 23.1% RTP. At 09:37 hours, the main generator was tripped at 20.4% RTP for voltage and overspeed testing. At 12:26 hours, the main generator was resynchronized to the grid at 23.9% RTP.
On March 20th at 09:50 hours, reactor power was reduced from 60.7% to 19.3% RTP due to high temperature and vibration on the #3 turbine bearing. At 11:30 hours, the main turbine was manually tripped at 19.6% RTP.
On March 21st at 03:16 hours, the reactor was manually scrammed at 21.3% RTP for repairs to the turbine bearing and SRV maintenance.
On March 25th at 03:37 hours, reactor criticality was achieved.
On March 26th at 14:59 hours, the main generator was synchronized to the grid at 19.1% RTP.
On March 28th at 08:20 hours, the reactor was restored to 100% RTP. At 22:02 hours, reactor power was reduced from 97.7% to 60.1% RTP for rod pattern adjustment.
On March 29th at 19:37 hours, reactor power was restored to 99.8% RTP.
Unit 2 ended the month of March 2005 at 100% RTP.
Type Reason Method F-Forced A-Equipment Failure (Explain) 1-Manual S-Scheduled B-Maintenance or Test 2-Manual Trip/Scram C-Refueling 3-Automatic Trip/Scram D-Regulatory Restriction 4-Continuation E-Operator Training/License Examination 5-Other (Explain)
F-Administrative G-Operational Error (Explain)
H-Other (Explain)
C. SAFETY/RELIEF VALVE OPERATION Date Valves Actuated No. & Type of Actuation Plant Condition Description of Event None during March 2005