ML051030056

From kanterella
Jump to navigation Jump to search
Email Update: D.C. Cook Containment Missile Shield Issue
ML051030056
Person / Time
Site: Cook  
Issue date: 12/03/2003
From: Landsman R
Division of Nuclear Materials Safety III
To: Reynolds S
NRC/RGN-III
References
FOIA/PA-2005-0075
Download: ML051030056 (1)


Text

-iG Duncan - Re: Getting back to you: Update: D.C. Cook Containment Missile Shield Issue Sagely From:

Ross Landsman To:

Steven Reynolds Date:

12/3/03 1:57PM

Subject:

Re: Getting back to you: Update: D.C. Cook Containment Missile Shield Issue Thanks for the info, but the referenced documents still do not state what the interaction coefficients are vs the 1.5 requirements, that was the original issue on my DPV/DPO that Travers told the staff to fix, its still not fixed, I guess the staff doesn't have to listen to the EDO, the DC COOK containments still do not meet code and are unacceptable, they have not been operable since I submitted the DPV in June of 2000. The staff just keeps blowing me off, allowing them to operate, hoping I'll go away.

>>> Steven Reynolds 12/02/03 12:26PM >>>

CC:

Jim Dyer; John Craig; Samuel Collins; William Travers