ADMINISTRATIVE CONTROLS
- j.
Technical Specification (TS) Bases Control Program This program provides a means for processing changes to the Bases of TSs.
- a.
Changes to the Bases of the TS shall be made under appropriate administrative controls and reviews.
- b.
Licensees may make changes to Bases without prior NRC approval provided the changes do not require either of the following:
- 1.
A change in the TS incorporated In the license or
- 2.
A change to the updated FSAR or Bases that requires NRC approval pursuant to 10 CFR 50.59.
- c.
The Bases Control Program shall contain provisions to ensure that the Bases are maintained consistent with the FSAR.
- d.
Proposed changes that meet the criteria of Specification 6.8.4.j.b above shall be reviewed and approved by the NRC prior to Implementation. Changes to the Bases implemented without prior NRC approval shall be provided to the NRC on a frequency consistent with 10 CFR 50.71(e).
6.9 REPORTING REQUIREMENTS ROUTINE REPORTS 6.9.1 In addition to the applicable reporting requirements of Title 10, Code of Federal Regulations, the following reports shall be submitted in accordance with 10 CFR 50.4.
STARTUP REPORT 6.9.1.1 DELETED 6.9.1.2 DELETED 6.9.1.3 DELETED ANNUAL REPORTSI-6.9.1.4 Annual reports covering the activities of the unit as described below for the previous calendar year shall be submitted prior to March 1 of each year. The initial report shall be submitted prior to March 1 of the year following initial criticality.
6.9.1.5 DELETED 1/
A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station.
SEQUOYAH - UNIT 1 6-11 Amendment No. 12, 32, 58, 72, 74, 148, 174, 233, 280,300
ADMINISTRATIVE CONTROLS ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT-/
6.9.1.6 The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted prior to May I of each year. The report shall Include summaries, interpretations, and analysis of trends of the results of the Radiological Environmental Monitoring Program for the reporting period. The material provided shall be consistent with the objectives outlined in (1) the ODCM and (2) Sections IV.B.2, IV.B.3, and IV.C of Appendix I to 10 CFR Part 50.
6.9.1.7 (Relocated to the ODCM.)
ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT-1/
6.9.1.8 The Annual Radioactive Effluent Release Report covering the operation of the unit during the previous calendar year shall be submitted prior to May I of each year. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be (1) consistent with the objectives outlined in the ODCM and PCP and (2) In conformance with 10 CFR 50.36a and Section IV.B.1 of Appendix I to 10 CFR Part 50.
6.9.1.9 (Relocated to the ODCM or PCP.)
1/
A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station; however, for units with separate radwaste systems, the submittal shall specify the releases of radioactive material from each unit.
SEQUOYAH - UNIT 1 6-12 Amendment No. 42, 58, 74, 117, 148, 169, 281,300
e ADMINISTRATIVE CONTROLS MONTHLY REACTOR OPERATING REPORT 6.9.1.10 DELETED CORE OPERATING LIMITS REPORT 6.9.1.14 Core operating limits shall be established and documented in the CORE OPERATING LIMITS REPORT before each reload cycle or any remaining part of a reload cycle for the following:
- 1. f1(Al) limits for Overtemperature Delta T Trip Setpoints and f2(AI) limits for Overpower Delta T Trip Setpoints for Specification 2.2.1.
- 2.
Moderator Temperature Coefficient BOL and EOL limits and 300 ppm surveillance limit for Specification 314.1.1.3,
- 3.
Shutdown Bank Insertion Limit for Specification 314.1.3.5,
- 4.
Control Bank Insertion Limits for Specification 3/4.1.3.6,
- 5.
AXIAL FLUX DIFFERENCE Limits for Specification 3/4.2.1,
- 6.
Heat Flux Hot Channel Factor and K(z) for Specification 3/4.2.2, and
- 7.
Nuclear Enthalpy Rise Hot Channel Factor for Specification 3/4.2.3.
6.9.1.14.a The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by NRC in:
- 1.
BAW-10180P-A, Rev. 1, NEMO - NODAL EXPANSION METHOD OPTIMIZED", March 1993. (FCF Proprietary)
(Methodology for Specification 3.1.1.3-Moderator Temperature Coefficient)
- 2.
BAW-1 01 69P-A, "RSG PLANT SAFETY ANALYSIS - B&W SAFETY ANALYSIS METHODOLOGY FOR RECIRCULATING STEAM GENERATOR PLANTS", October 1989.
(FCF Proprietary)
(Methodology for Specification 3.1.1.3-Moderator Temperature Coefficient)
- 3.
BAW-10163P-A, Core Operating Limit Methodology for Westinghouse-Designed PWRs, June 1989. (FCF Proprietary)
(Methodology for Specification 2.2.1, - Limiting Safety System Settings f1(Al), f2(al) limits], 3.1.3.5 - Shutdown Bank Insertion Limits, 3.1.3.6 - Control Bank Insertion Limits, 3/4.2.1 - Axial Flux Difference, 3/4.2.2 - Heat Flux Hot Channel Factor, 3/4.2.3 -
Nuclear Enthalpy Rise Hot Channel Factor)
- 4.
BAW-10168P-A, Rev.2, RSG LOCA - B&W Loss of Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (FCF Proprietary)
(Methodology for Specification 3/4.2.2 - Heat Flux Hot Channel Factor)
- 5.
BAW-10168P-A, Rev 3, RSG LOCA - B&W Loss of Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (FCF Proprietary)
(Methodology for Specification 3/4.2.2 - Heat Flux Hot Channel Factor)
SEQUOYAH - UNIT 1 6-13 Amendment No. 52,58, 72, 74,117,152, 155,156,171, 216, 223,281,300
ADMINISTRATIVE CONTROLS ANNUAL REPORTS /
6.9.1.4 Annual reports covering the activities of the unit as described below for the previous calendar year shall be submitted prior to March 1 of each year. The initial report shall be submitted prior to March 1 of the year following Initial criticality.
6.9.1.5 DELETED 1/A single submittal may be made for a multiple unit station. The submittal should combine those sections that are common to all units at the station.
I SEQUOYAH - UNIT 2 6-11 Amendment No. 34, 50, 66, 107,134, 165, 271, 272,289
r ADMINISTRATIVE CONTROLS MONTHLY REACTOR OPERATING REPORT 6.9.1.10 DELETED CORE OPERATING LIMITS REPORT 6.9.1.14 Core operating limits shall be established and documented in the CORE OPERATING LIMITS REPORT before each reload cycle or any remaining part of a reload cycle for the following:
- 1.
f1(Al) limits for Overtemperature Delta T Trip Setpoints and f2(AI) limits for Overpower Delta T Trip Setpoints for Specification 2.2.1.
- 2.
Moderator Temperature Coefficient BOL and EOL limits and 300 ppm surveillance limit for Specification 3/4.1.1.3,
- 3.
Shutdown Bank Insertion Limit for Specification 3/4.1.3.5,
- 4.
Control Bank Insertion Limits for Specification 3/4.1.3.6,
- 5.
AXIAL FLUX DIFFERENCE Limits for Specification 3/4.2.1,
- 6.
Heat Flux Hot Channel Factor and K(z) for Specification 314.2.2, and
- 7.
Nuclear Enthalpy Rise Hot Channel Factor for Specification 3/4.2.3.
6.9.1.14.a The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by NRC in:
- 1.
BAW-10180P-A, Rev. 1, "NEMO - NODAL EXPANSION METHOD OPTIMIZED", March 1993. (FCF Proprietary)
(Methodology for Specification 3.1.1.3-Moderator Temperature Coefficient)
- 2.
BAW-1 01 69P-A, "RSG PLANT SAFETY ANALYSIS - B&W SAFETY ANALYSIS METHODOLOGY FOR RECIRCULATING STEAM GENERATOR PLANTS", October 1989.
(FCF Proprietary)
(Methodology for Specification 3.1.1.3-Moderator Temperature Coefficient)
- 3.
BAW-10163P-A, Core Operating Limit Methodology for Westinghouse-Designed PWRs, June 1989. (FCF Proprietary)
(Methodology for Specification 2.2.1, - Limiting Safety System Settings [fi(Al), f2(AI) limits], 3.1.3.5 - Shutdown Bank Insertion Limits, 3.1.3.6 - Control Bank Insertion Limits, 3/4.2.1 - Axial Flux Difference, 3/4.2.2 - Heat Flux Hot Channel Factor, 3/4.2.3
- Nuclear Enthalpy Rise Hot Channel Factor)
- 4.
BAW-10168P-A, Rev. 2, RSG LOCA - B&W Loss of Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (FCF Proprietary)
(Methodology for Specification 3/4.2.2 - Heat Flux Hot Channel Factor)
- 5.
BAW-1 01 68P-A, Rev 3, RSG LOCA - B&W Loss of Coolant Accident Evaluation Model for Recirculating Steam Generator Plants, (FCF Proprietary)
(Methodology for Specification 3/4.2.2 - Heat Flux Hot Channel Factor)
SEQUOYAH - UNIT 2 6-13 Amendment No. 44, 50, 64, 66,107, 134, 142,146,161, 206,214,223, 272, 289